In order to support the physical research on the EAST tokamak,a new positive ion source with designed beam energy of 120 keV was proposed to be developed.Accelerator structure is one of the key components of the ion s...In order to support the physical research on the EAST tokamak,a new positive ion source with designed beam energy of 120 keV was proposed to be developed.Accelerator structure is one of the key components of the ion source.Through the finite element analysis method,the electrostatic analyses of insulators and grid plates were carried out,the material and structure parameters of insulators were determined.The maximum electric field around each insulator is about 4 kV/mm,and the maximum electric field between grids is about 14 kV/mm,which can meet the 120 keV withstand voltage holding.The insulation system for the positive ion source accelerator with 120 keV is designed,and the connection and basic parameters of insulators and support flanges are analyzed and determined.展开更多
Graph computing has become pervasive in many applications due to its capacity to represent complex relationships among different objects in the big data era.However,general-purpose architectures are computationally in...Graph computing has become pervasive in many applications due to its capacity to represent complex relationships among different objects in the big data era.However,general-purpose architectures are computationally inefficient for graph algorithms,and dedicated architectures can provide high efficiency,but lack flexibility.To address these challenges,this paper proposes ParaGraph,a reduced instruction set computing-five(RISC-V)-based software-hardware co-designed graph computing accelerator that can process graph algorithms in parallel,and also establishes a performance evaluation model to assess the efficiency of co-acceleration.ParaGraph handles parallel processing of typical graph algorithms on the hardware side,while performing overall functional control on the software side with custom designed instructions.ParaGraph is verified on the XCVU440 field-programmable gate array(FPGA)board with E203,a RISC-V processor.Compared with current mainstream graph computing accelerators,ParaGraph consumes 7.94%less block RAM(BRAM)resources than ThunderGP.Its power consumption is reduced by 86.90%,24.90%,and 76.38%compared with ThunderGP,HitGraph,and GraphS,respectively.The power efficiency of connected components(CC)and degree centrality(DC)algorithms is improved by an average of 6.50 times over ThunderGP,2.51 times over HitGraph,and 3.99 times over GraphS.The software-hardware co-design acceleration performance indicators H/W.Cap for CC and DC are 13.02 and 14.02,respectively.展开更多
Aqueous zincion batteries are highly favored for grid-level energy storage owing to their low cost and high safety,but their practical application is limited by slow ion migration.To address this,a strategy has been d...Aqueous zincion batteries are highly favored for grid-level energy storage owing to their low cost and high safety,but their practical application is limited by slow ion migration.To address this,a strategy has been developed to create a cation-accelerating electric field on the surface of the cathode to achieve ultrafast Zn^(2+)diffusion kinetics.By employing electrodeposition to coat MoS_(2)on the surface of BaV_(6)O_(16)·3H_(2)O nanowires,the directional builtin electric field generated at the heterointerface acts as a cation accelerator,continuously accelerating Zn^(2+)diffusion into the active material.The optimized Zn^(2+)diffusion coefficient in CC@BaV-V_(6)O_(16)·3H_(2)@MoS_(2)(7.5×10^(8)cm^(2)s^(-1)) surpasses that of most reported V-based cathodes.Simultaneously,MoS_(2)serving as a cathodic armor extends the cycling life of the Zn-CC@BaV_(6)O_(16)·3H_(2)@MoS_(2)full batteries to over 10000 cycles.This work provides valuable insights into optimizing ion diffusion kinetics for high-performance energy storage devices.展开更多
A 4 MeV RF linear accelerator for electron beam irradiation applications has been developed at the PBP-CMU Electron Linac Laboratory,Thailand.The system has been reengineered using a decommissioned medical linear acce...A 4 MeV RF linear accelerator for electron beam irradiation applications has been developed at the PBP-CMU Electron Linac Laboratory,Thailand.The system has been reengineered using a decommissioned medical linear accelerator.The main components include a thermionic DC electron gun,an RF linear accelerator,a beam diagnostic chamber,and a beam exit window for electron beam irradiation.Therefore,reengineering must be performed based on the characteristics of the electron beam and its dynamics throughout the system.In this study,the electron beam current density emitted from the cathode was calculated based on the thermionic emission theory,and the result was used to produce the electron beam distribution in the gun using CST Studio Suite^(■)software.The properties of the electron beam and its acceleration in the linear accelerator and downstream diagnostic section were studied using the ASTRA electron beam dynamics simulation code,with the aim of producing an electron beam with an average energy of 4 MeV at the linear accelerator exit.The transverse beam profile and electron deposition dose in the ambient environment were calculated using Geant4 Monte Carlo simulation software to estimate the beam performance for the irradiation experiments.The parameters studied can be used as guidelines for machine operation and future experimental plans.展开更多
An intense laser pulse focused onto a plasma can excite nonlinear plasma waves.Under appropriate conditions,electrons from the background plasma are trapped in the plasma wave and accelerated to ultra-relativistic vel...An intense laser pulse focused onto a plasma can excite nonlinear plasma waves.Under appropriate conditions,electrons from the background plasma are trapped in the plasma wave and accelerated to ultra-relativistic velocities.This scheme is called a laser wakefield accelerator.In this work,we present results from a laser wakefield acceleration experiment using a petawatt-class laser to excite the wakefields as well as nanoparticles to assist the injection of electrons into the accelerating phase of the wakefields.We find that a 10-cm-long,nanoparticle-assisted laser wakefield accelerator can generate 340 pC,10±1.86 GeV electron bunches with a 3.4 GeV rms convolved energy spread and a 0.9 mrad rms divergence.It can also produce bunches with lower energies in the 4–6 GeV range.展开更多
The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides...The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides such as^(60)Fe.In this work,we stepped up the development of an accelerator mass spectrometry(AMS)method for detecting^(60)Fe using the HI-13tandem accelerator at the China Institute of Atomic Energy(CIAE).Since interferences could not be sufficiently removed solely with the existing magnetic systems of the tandem accelerator and the following Q3D magnetic spectrograph,a Wien filter with a maximum voltage of±60 kV and a maximum magnetic field of 0.3 T was installed after the accelerator magnetic systems to lower the detection background for the low abundance nuclide^(60)Fe.A 1μm thick Si_(3)N_(4) foil was installed in front of the Q3D as an energy degrader.For particle detection,a multi-anode gas ionization chamber was mounted at the center of the focal plane of the spectrograph.Finally,an^(60)Fe sample with an abundance of 1.125×10^(-10)was used to test the new AMS system.These results indicate that^(60)Fe can be clearly distinguished from the isobar^(60)Ni.The sensitivity was assessed to be better than 4.3×10^(-14)based on blank sample measurements lasting 5.8 h,and the sensitivity could,in principle,be expected to be approximately 2.5×10^(-15)when the data were accumulated for 100 h,which is feasible for future lunar sample measurements because the main contaminants were sufficiently separated.展开更多
In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiat...In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiation area is required for the extracted ion beams,which is crucial because it directly affects the experimental precision and therapeutic effect.Specifically,ultra-large-area and high-uniformity scanning are crucial requirements for spacecraft radiation effects assessment and serve as core specification for beamline terminal design.In the 300 MeV proton and heavy ion accelerator complex at the Space Environment Simulation and Research Infrastructure(SESRI),proton and heavy ion beams will be accelerated and ultimately delivered to three irradiation terminals.In order to achieve the required large irradiation area of 320 mm×320 mm,horizontal and vertical scanning magnets are used in the extraction beam line.However,considering the various requirements for beam species and energies,the tracking accuracy of power supplies(PSs),the eddy current effect of scanning magnets,and the fluctuation of ion bunch structure will reduce the irradiation uniformity.To mitigate these effects,a beam uniformity optimization method based on the measured beam distribution was proposed and applied in the accelerator complex at SESRI.In the experiment,the uniformity is successfully optimized from 75%to over 90%after five iterations of adjustment to the PS waveforms.In this paper,the method and experimental results were introduced.展开更多
Prompt radiation emitted during accelerator operation poses a significant health risk,necessitating a thorough search and securing of hazardous areas prior to initiation.Currently,manual sweep methods are employed.How...Prompt radiation emitted during accelerator operation poses a significant health risk,necessitating a thorough search and securing of hazardous areas prior to initiation.Currently,manual sweep methods are employed.However,the limitations of manual sweeps have become increasingly evident with the implementation of large-scale accelerators.By leveraging advancements in machine vision technology,the automatic identification of stranded personnel in controlled areas through camera imagery presents a viable solution for efficient search and security.Given the criticality of personal safety for stranded individuals,search and security processes must be sufficiently reliable.To ensure comprehensive coverage,180°camera groups were strategically positioned on both sides of the accelerator tunnel to eliminate blind spots within the monitoring range.The YOLOV8 network model was modified to enable the detection of small targets,such as hands and feet,as well as larger targets formed by individuals near the cameras.Furthermore,the system incorporates a pedestrian recognition model that detects human body parts,and an information fusion strategy is used to integrate the detected head,hands,and feet with the identified pedestrians as a cohesive unit.This strategy enhanced the capability of the model to identify pedestrians obstructed by equipment,resulting in a notable improvement in the recall rate.Specifically,recall rates of 0.915 and 0.82were obtained for Datasets 1 and 2,respectively.Although there was a slight decrease in accuracy,it aligned with the intended purpose of the search-and-secure software design.Experimental tests conducted within an accelerator tunnel demonstrated the effectiveness of this approach in achieving reliable recognition outcomes.展开更多
We present a first on-chip positron accelerator based on dielectric laser acceleration.This innovative approach significantly reduces the physical dimensions of the positron acceleration apparatus,enhancing its feasib...We present a first on-chip positron accelerator based on dielectric laser acceleration.This innovative approach significantly reduces the physical dimensions of the positron acceleration apparatus,enhancing its feasibility for diverse applications.By utilizing a stacked acceleration structure and far-infrared laser technology,we are able to achieve a seven-stage acceleration structure that surpasses the distance and energy gain of using the previous dielectric laser acceleration methods.Additionally,we are able to compress the positron beam to an ultrafast sub-femtosecond scale during the acceleration process,compared with the traditional methods,the positron beam is compressed to a greater extent.We also demonstrate the robustness of the stacked acceleration structure through the successful acceleration of the positron beam.展开更多
The flexibility in radiotherapy can be improved if patients can be moved between any one of the department’s medical linear accelerators (LINACs) without the need to change anything in the patient’s treatment plan. ...The flexibility in radiotherapy can be improved if patients can be moved between any one of the department’s medical linear accelerators (LINACs) without the need to change anything in the patient’s treatment plan. For this to be possible, the dosimetric characteristics of the various accelerators must be the same, or nearly the same. The purpose of this work is to describe further and compare measurements and parameters after the initial vendor-recommended beam matching of the five LINACs. Deviations related to dose calculations and to beam matched accelerators may compromise treatment accuracy. The safest and most practical way to ensure that all accelerators are within clinical acceptable accuracy is to include TPS calculations in the LINACs matching evaluation. Treatment planning system (TPS) was used to create three photons plans with different field sizes 3 × 3 cm, 10 × 10 cm and 25 × 25 cm at a depth of 4.5 cm in Perspex. Calculated TPS plans were sent to Mosaiq to be delivered by five LINACs. TPS plans were compared with five LINACs measurements data using Gamma analyses of 2% and 2 mm. The results suggest that for four out of the five LINACs, there was generally good agreement, less than a 2% deviation between the planned dose distribution and the measured dose distribution. However, one specific LINAC named “Asterix” exhibited a deviation of 2.121% from the planned dose. The results show that all of the LINACs’ performance were within the acceptable deviation and delivering radiation dose consistently and accurately.展开更多
Massive computational complexity and memory requirement of artificial intelligence models impede their deploy-ability on edge computing devices of the Internet of Things(IoT).While Power-of-Two(PoT)quantization is pro...Massive computational complexity and memory requirement of artificial intelligence models impede their deploy-ability on edge computing devices of the Internet of Things(IoT).While Power-of-Two(PoT)quantization is pro-posed to improve the efficiency for edge inference of Deep Neural Networks(DNNs),existing PoT schemes require a huge amount of bit-wise manipulation and have large memory overhead,and their efficiency is bounded by the bottleneck of computation latency and memory footprint.To tackle this challenge,we present an efficient inference approach on the basis of PoT quantization and model compression.An integer-only scalar PoT quantization(IOS-PoT)is designed jointly with a distribution loss regularizer,wherein the regularizer minimizes quantization errors and training disturbances.Additionally,two-stage model compression is developed to effectively reduce memory requirement,and alleviate bandwidth usage in communications of networked heterogenous learning systems.The product look-up table(P-LUT)inference scheme is leveraged to replace bit-shifting with only indexing and addition operations for achieving low-latency computation and implementing efficient edge accelerators.Finally,comprehensive experiments on Residual Networks(ResNets)and efficient architectures with Canadian Institute for Advanced Research(CIFAR),ImageNet,and Real-world Affective Faces Database(RAF-DB)datasets,indicate that our approach achieves 2×∼10×improvement in the reduction of both weight size and computation cost in comparison to state-of-the-art methods.A P-LUT accelerator prototype is implemented on the Xilinx KV260 Field Programmable Gate Array(FPGA)platform for accelerating convolution operations,with performance results showing that P-LUT reduces memory footprint by 1.45×,achieves more than 3×power efficiency and 2×resource efficiency,compared to the conventional bit-shifting scheme.展开更多
A compact 10 MeV S-band irradiation electron linear accelerator(linac)was developed to simulate electronic radiation in outer space and perform electron irradiation effect tests on spacecraft materials and devices.Acc...A compact 10 MeV S-band irradiation electron linear accelerator(linac)was developed to simulate electronic radiation in outer space and perform electron irradiation effect tests on spacecraft materials and devices.According to the requirements of space environment simulation,the electron beam energy can be adjusted in the range from 3.5 to 10 MeV,and the average current can be adjusted in the range from 0.1 to 1 mA.The linac should be capable of providing beam irradiation over a large area of 1 m^(2) with a uniformity greater than 90% and a scanning rate of 100 Hz.A novel method was applied to achieve such a high beam scanning rate by combining a kicker and a scanning magnet.Based on this requirement,a design for the10 MeV linac is proposed with an RF power pulse repetition rate of 500 Hz;it includes a thermal cathode electron gun,a bunching-accelerating section,and a scanning transport line.The detailed physical design and dynamic simulation results of the proposed 10 MeV electron linac are presented in this paper.展开更多
Quantized training has been proven to be a prominent method to achieve deep neural network training under limited computational resources.It uses low bit-width arithmetics with a proper scaling factor to achieve negli...Quantized training has been proven to be a prominent method to achieve deep neural network training under limited computational resources.It uses low bit-width arithmetics with a proper scaling factor to achieve negligible accuracy loss.Cambricon-Q is the ASIC design proposed to efficiently support quantized training,and achieves significant performance improvement.However,there are still two caveats in the design.First,Cambricon-Q with different hardware specifications may lead to different numerical errors,resulting in non-reproducible behaviors which may become a major concern in critical applications.Second,Cambricon-Q cannot leverage data sparsity,where considerable cycles could still be squeezed out.To address the caveats,the acceleration core of Cambricon-Q is redesigned to support fine-grained irregular data processing.The new design not only enables acceleration on sparse data,but also enables performing local dynamic quantization by contiguous value ranges(which is hardware independent),instead of contiguous addresses(which is dependent on hardware factors).Experimental results show that the accuracy loss of the method still keeps negligible,and the accelerator achieves 1.61×performance improvement over Cambricon-Q,with about 10%energy increase.展开更多
Molecular Dynamics(MD)simulation for computing Interatomic Potential(IAP)is a very important High-Performance Computing(HPC)application.MD simulation on particles of experimental relevance takes huge computation time,...Molecular Dynamics(MD)simulation for computing Interatomic Potential(IAP)is a very important High-Performance Computing(HPC)application.MD simulation on particles of experimental relevance takes huge computation time,despite using an expensive high-end server.Heterogeneous computing,a combination of the Field Programmable Gate Array(FPGA)and a computer,is proposed as a solution to compute MD simulation efficiently.In such heterogeneous computation,communication between FPGA and Computer is necessary.One such MD simulation,explained in the paper,is the(Artificial Neural Network)ANN-based IAP computation of gold(Au_(147)&Au_(309))nanoparticles.MD simulation calculates the forces between atoms and the total energy of the chemical system.This work proposes the novel design and implementation of an ANN IAP-based MD simulation for Au_(147)&Au_(309) using communication protocols,such as Universal Asynchronous Receiver-Transmitter(UART)and Ethernet,for communication between the FPGA and the host computer.To improve the latency of MD simulation through heterogeneous computing,Universal Asynchronous Receiver-Transmitter(UART)and Ethernet communication protocols were explored to conduct MD simulation of 50,000 cycles.In this study,computation times of 17.54 and 18.70 h were achieved with UART and Ethernet,respectively,compared to the conventional server time of 29 h for Au_(147) nanoparticles.The results pave the way for the development of a Lab-on-a-chip application.展开更多
With the rapid development of deep learning algorithms,the computational complexity and functional diversity are increasing rapidly.However,the gap between high computational density and insufficient memory bandwidth ...With the rapid development of deep learning algorithms,the computational complexity and functional diversity are increasing rapidly.However,the gap between high computational density and insufficient memory bandwidth under the traditional von Neumann architecture is getting worse.Analyzing the algorithmic characteristics of convolutional neural network(CNN),it is found that the access characteristics of convolution(CONV)and fully connected(FC)operations are very different.Based on this feature,a dual-mode reronfigurable distributed memory architecture for CNN accelerator is designed.It can be configured in Bank mode or first input first output(FIFO)mode to accommodate the access needs of different operations.At the same time,a programmable memory control unit is designed,which can effectively control the dual-mode configurable distributed memory architecture by using customized special accessing instructions and reduce the data accessing delay.The proposed architecture is verified and tested by parallel implementation of some CNN algorithms.The experimental results show that the peak bandwidth can reach 13.44 GB·s^(-1)at an operating frequency of 120 MHz.This work can achieve 1.40,1.12,2.80 and 4.70 times the peak bandwidth compared with the existing work.展开更多
Deep neural networks(DNN)are widely used in image recognition,image classification,and other fields.However,as the model size increases,the DNN hardware accelerators face the challenge of higher area overhead and ener...Deep neural networks(DNN)are widely used in image recognition,image classification,and other fields.However,as the model size increases,the DNN hardware accelerators face the challenge of higher area overhead and energy consumption.In recent years,stochastic computing(SC)has been considered a way to realize deep neural networks and reduce hardware consumption.A probabilistic compensation algorithm is proposed to solve the accuracy problem of stochastic calculation,and a fully parallel neural network accelerator based on a deterministic method is designed.The software simulation results show that the accuracy of the probability compensation algorithm on the CIFAR-10 data set is 95.32%,which is 14.98%higher than that of the traditional SC algorithm.The accuracy of the deterministic algorithm on the CIFAR-10 dataset is 95.06%,which is 14.72%higher than that of the traditional SC algorithm.The results of Very Large Scale Integration Circuit(VLSI)hardware tests show that the normalized energy efficiency of the fully parallel neural network accelerator based on the deterministic method is improved by 31%compared with the circuit based on binary computing.展开更多
Corticotomy is a clinical procedure to accelerate orthodontic tooth movement characterized by the regional acceleratory phenomenon(RAP).Despite its therapeutic effects,the surgical risk and unclear mechanism hamper th...Corticotomy is a clinical procedure to accelerate orthodontic tooth movement characterized by the regional acceleratory phenomenon(RAP).Despite its therapeutic effects,the surgical risk and unclear mechanism hamper the clinical application.Numerous evidences support macrophages as the key immune cells during bone remodeling.Our study discovered that the monocyte-derived macrophages primarily exhibited a pro-inflammatory phenotype that dominated bone remodeling in corticotomy by CX3CR1CreERT2;R26GFP lineage tracing system.Fluorescence staining,flow cytometry analysis,and western blot determined the significantly enhanced expression of binding immunoglobulin protein(BiP)and emphasized the activation of sensor activating transcription factor 6(ATF6)in macrophages.Then,we verified that macrophage specific ATF6 deletion(ATF6f/f;CX3CR1CreERT2 mice)decreased the proportion of pro-inflammatory macrophages and therefore blocked the acceleration effect of corticotomy.In contrast,macrophage ATF6 overexpression exaggerated the acceleration of orthodontic tooth movement.In vitro experiments also proved that higher proportion of pro-inflammatory macrophages was positively correlated with higher expression of ATF6.At the mechanism level,RNA-seq and CUT&Tag analysis demonstrated that ATF6 modulated the macrophage-orchestrated inflammation through interacting with Tnfαpromotor and augmenting its transcription.Additionally,molecular docking simulation and dual-luciferase reporter system indicated the possible binding sites outside of the traditional endoplasmic reticulum-stress response element(ERSE).Taken together,ATF6 may aggravate orthodontic bone remodeling by promoting Tnfαtranscription in macrophages,suggesting that ATF6 may represent a promising therapeutic target for non-invasive accelerated orthodontics.展开更多
The level of ground shaking,as determined by the peak ground acceleration(PGA),can be used to analyze seismic hazard at a certain location and is crucial for constructing earthquake-resistant structures.Predicting the...The level of ground shaking,as determined by the peak ground acceleration(PGA),can be used to analyze seismic hazard at a certain location and is crucial for constructing earthquake-resistant structures.Predicting the PGA immediately after an earthquake occurs allows for the issuing of a warning by an earthquake early warning system.In this study,we propose a deep learning model,ConvMixer,to predict the PGA recorded by weak-motion velocity seismometers in Japan.We use 5-s threecomponent seismograms,from 2 s before until 3 s after the P-wave arrival time of the earthquake.Our dataset comprised more than 50,000 single-station waveforms recorded by 10 seismic stations in the K-NET,Kiki-NET,and Hi-Net networks between 2004 and 2023.The proposed ConvMixer is a patch-based model that extracts global features from input seismic data and predicts the PGA of an earthquake by combining depth and pointwise convolutions.The proposed ConvMixer network had a mean absolute error of 2.143 when applied to the test set and outperformed benchmark deep learning models.In addition,the proposed ConvMixer demonstrated the ability to predict the PGA at the corresponding station site based on 1-second waveforms obtained immediately after the arrival time of the P-wave.展开更多
Background Higher accelerometer-assessed volume and intensity of physical activity(PA)have been associated with a longer life expectancy but can be difficult to translate into recommended doses of PA.We aimed to:(a)im...Background Higher accelerometer-assessed volume and intensity of physical activity(PA)have been associated with a longer life expectancy but can be difficult to translate into recommended doses of PA.We aimed to:(a)improve interpretability by producing UK Biobank age-referenced centiles for PA volume and intensity;(b)inform public-health messaging by examining how adding recommended quantities of moderate and vigorous PA affect PA volume and intensity.Methods 92,480 UK Biobank participants aged 43-80 years with wrist-worn accelerometer data were included.Average acceleration and intensity gradient were derived as proxies for PA volume and intensity.We generated sex-specific centile curves using Generalized Additive Models for Location Scale and Shape(GAMLSS)and modeled the effect of adding moderate(walking)or vigorous(running)activity on the combined change in the volume and intensity centiles(change in PA profile).Results In men,volume was lower as age increased while intensity was lower after age 55;in women,both volume and intensity were lower as age increased.Adding 150 min of moderate PA weekly(5×30 min walking)increased the PA profile by 4 percentage points.Defining moderate PA as brisk walking approximately doubled the increase(9 percentage points)while 75 min of vigorous PA weekly(5×15 min running)trebled the increase(13 percentage points).Conclusion These UK Biobank reference centiles provide a benchmark for interpretation of accelerometer data.Application of our translational methods demonstrate that meeting PA guidelines through shorter duration vigorous activity is more beneficial to the PA profile(volume and intensity)than longer duration moderate activity.展开更多
The harmonic balance method(HBM)has been widely applied to get the periodic solution of nonlinear systems,however,its convergence rate as well as computation efficiency is dramatically degraded when the system is high...The harmonic balance method(HBM)has been widely applied to get the periodic solution of nonlinear systems,however,its convergence rate as well as computation efficiency is dramatically degraded when the system is highly non-smooth,e.g.,discontinuous.In order to accelerate the convergence,an enriched HBM is developed in this paper where the non-smooth Bernoulli bases are additionally introduced to enrich the conventional Fourier bases.The basic idea behind is that the convergence rate of the HB solution,as a truncated Fourier series,can be improved if the smoothness of the solution becomes finer.Along this line,using non-smooth Bernoulli bases can compensate the highly non-smooth part of the solution and then,the smoothness of the residual part for Fourier approximation is improved so as to achieve accelerated convergence.Numerical examples are conducted on systems with non-smooth restoring and/or external forces.The results confirm that the proposed enriched HBM indeed increases the convergence rate and the increase becomes more significant if more non-smooth bases are used.展开更多
基金supported by National Natural Science Foundation of China(No.11975261)。
文摘In order to support the physical research on the EAST tokamak,a new positive ion source with designed beam energy of 120 keV was proposed to be developed.Accelerator structure is one of the key components of the ion source.Through the finite element analysis method,the electrostatic analyses of insulators and grid plates were carried out,the material and structure parameters of insulators were determined.The maximum electric field around each insulator is about 4 kV/mm,and the maximum electric field between grids is about 14 kV/mm,which can meet the 120 keV withstand voltage holding.The insulation system for the positive ion source accelerator with 120 keV is designed,and the connection and basic parameters of insulators and support flanges are analyzed and determined.
基金Supported by the National Key R&D Program of China(No.2022ZD0119001)the National Natural Science Foundation of China(No.61834005)+1 种基金the Shaanxi Province Key R&D Plan(No.2022GY-027,2021GY-029)the Key Scientific Research Project of Shaanxi Department of Education(No.22JY060).
文摘Graph computing has become pervasive in many applications due to its capacity to represent complex relationships among different objects in the big data era.However,general-purpose architectures are computationally inefficient for graph algorithms,and dedicated architectures can provide high efficiency,but lack flexibility.To address these challenges,this paper proposes ParaGraph,a reduced instruction set computing-five(RISC-V)-based software-hardware co-designed graph computing accelerator that can process graph algorithms in parallel,and also establishes a performance evaluation model to assess the efficiency of co-acceleration.ParaGraph handles parallel processing of typical graph algorithms on the hardware side,while performing overall functional control on the software side with custom designed instructions.ParaGraph is verified on the XCVU440 field-programmable gate array(FPGA)board with E203,a RISC-V processor.Compared with current mainstream graph computing accelerators,ParaGraph consumes 7.94%less block RAM(BRAM)resources than ThunderGP.Its power consumption is reduced by 86.90%,24.90%,and 76.38%compared with ThunderGP,HitGraph,and GraphS,respectively.The power efficiency of connected components(CC)and degree centrality(DC)algorithms is improved by an average of 6.50 times over ThunderGP,2.51 times over HitGraph,and 3.99 times over GraphS.The software-hardware co-design acceleration performance indicators H/W.Cap for CC and DC are 13.02 and 14.02,respectively.
基金National Natural Science Foundation of China (61761047 and 41876055)Program for Innovative Research Team (in Science and Technology) in University of Yunnan Province。
文摘Aqueous zincion batteries are highly favored for grid-level energy storage owing to their low cost and high safety,but their practical application is limited by slow ion migration.To address this,a strategy has been developed to create a cation-accelerating electric field on the surface of the cathode to achieve ultrafast Zn^(2+)diffusion kinetics.By employing electrodeposition to coat MoS_(2)on the surface of BaV_(6)O_(16)·3H_(2)O nanowires,the directional builtin electric field generated at the heterointerface acts as a cation accelerator,continuously accelerating Zn^(2+)diffusion into the active material.The optimized Zn^(2+)diffusion coefficient in CC@BaV-V_(6)O_(16)·3H_(2)@MoS_(2)(7.5×10^(8)cm^(2)s^(-1)) surpasses that of most reported V-based cathodes.Simultaneously,MoS_(2)serving as a cathodic armor extends the cycling life of the Zn-CC@BaV_(6)O_(16)·3H_(2)@MoS_(2)full batteries to over 10000 cycles.This work provides valuable insights into optimizing ion diffusion kinetics for high-performance energy storage devices.
基金supported by Chiang Mai University for providing infrastructure and the NSRF via the Program Management Unit for Human Resources&Institutional Development,Research and Innovation[grant number B05F650022]for the software CST Studio Suite^(■)2023Financial support for the reengineering and commissioning of the accelerator system was provided by the Thailand Center of Excellence in Physics(ThEP Center),Science and Technology Park Chiang Mai University(CMU STeP)。
文摘A 4 MeV RF linear accelerator for electron beam irradiation applications has been developed at the PBP-CMU Electron Linac Laboratory,Thailand.The system has been reengineered using a decommissioned medical linear accelerator.The main components include a thermionic DC electron gun,an RF linear accelerator,a beam diagnostic chamber,and a beam exit window for electron beam irradiation.Therefore,reengineering must be performed based on the characteristics of the electron beam and its dynamics throughout the system.In this study,the electron beam current density emitted from the cathode was calculated based on the thermionic emission theory,and the result was used to produce the electron beam distribution in the gun using CST Studio Suite^(■)software.The properties of the electron beam and its acceleration in the linear accelerator and downstream diagnostic section were studied using the ASTRA electron beam dynamics simulation code,with the aim of producing an electron beam with an average energy of 4 MeV at the linear accelerator exit.The transverse beam profile and electron deposition dose in the ambient environment were calculated using Geant4 Monte Carlo simulation software to estimate the beam performance for the irradiation experiments.The parameters studied can be used as guidelines for machine operation and future experimental plans.
基金supported by the Air Force Office of Scientific Research Grant No.FA9550-17-1-0264supported by the DOE,Office of Science,Fusion Energy Sciences under Contract No.DE-SC0021125+2 种基金supported by the U.S.Department of Energy Grant No.DESC0011617.D.A.Jarozynski,E.Brunetti,B.Ersfeld,and S.Yoffe would like to acknowledge support from the U.K.EPSRC(Grant Nos.EP/J018171/1 and EP/N028694/1)the European Union’s Horizon 2020 research and innovation program under Grant Agreement No.871124 Laserlab-Europe and EuPRAXIA(Grant No.653782)funded by the N8 research partnership and EPSRC(Grant No.EP/T022167/1).
文摘An intense laser pulse focused onto a plasma can excite nonlinear plasma waves.Under appropriate conditions,electrons from the background plasma are trapped in the plasma wave and accelerated to ultra-relativistic velocities.This scheme is called a laser wakefield accelerator.In this work,we present results from a laser wakefield acceleration experiment using a petawatt-class laser to excite the wakefields as well as nanoparticles to assist the injection of electrons into the accelerating phase of the wakefields.We find that a 10-cm-long,nanoparticle-assisted laser wakefield accelerator can generate 340 pC,10±1.86 GeV electron bunches with a 3.4 GeV rms convolved energy spread and a 0.9 mrad rms divergence.It can also produce bunches with lower energies in the 4–6 GeV range.
基金supported by the National Natural Science Foundation of China(Nos.12125509,12222514,11961141003,and 12005304)National Key Research and Development Project(No.2022YFA1602301)+1 种基金CAST Young Talent Support Planthe CNNC Science Fund for Talented Young Scholars Continuous support for basic scientific research projects。
文摘The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides such as^(60)Fe.In this work,we stepped up the development of an accelerator mass spectrometry(AMS)method for detecting^(60)Fe using the HI-13tandem accelerator at the China Institute of Atomic Energy(CIAE).Since interferences could not be sufficiently removed solely with the existing magnetic systems of the tandem accelerator and the following Q3D magnetic spectrograph,a Wien filter with a maximum voltage of±60 kV and a maximum magnetic field of 0.3 T was installed after the accelerator magnetic systems to lower the detection background for the low abundance nuclide^(60)Fe.A 1μm thick Si_(3)N_(4) foil was installed in front of the Q3D as an energy degrader.For particle detection,a multi-anode gas ionization chamber was mounted at the center of the focal plane of the spectrograph.Finally,an^(60)Fe sample with an abundance of 1.125×10^(-10)was used to test the new AMS system.These results indicate that^(60)Fe can be clearly distinguished from the isobar^(60)Ni.The sensitivity was assessed to be better than 4.3×10^(-14)based on blank sample measurements lasting 5.8 h,and the sensitivity could,in principle,be expected to be approximately 2.5×10^(-15)when the data were accumulated for 100 h,which is feasible for future lunar sample measurements because the main contaminants were sufficiently separated.
基金Supported by National Key R&D Program of China(2019YFA0405400)。
文摘In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiation area is required for the extracted ion beams,which is crucial because it directly affects the experimental precision and therapeutic effect.Specifically,ultra-large-area and high-uniformity scanning are crucial requirements for spacecraft radiation effects assessment and serve as core specification for beamline terminal design.In the 300 MeV proton and heavy ion accelerator complex at the Space Environment Simulation and Research Infrastructure(SESRI),proton and heavy ion beams will be accelerated and ultimately delivered to three irradiation terminals.In order to achieve the required large irradiation area of 320 mm×320 mm,horizontal and vertical scanning magnets are used in the extraction beam line.However,considering the various requirements for beam species and energies,the tracking accuracy of power supplies(PSs),the eddy current effect of scanning magnets,and the fluctuation of ion bunch structure will reduce the irradiation uniformity.To mitigate these effects,a beam uniformity optimization method based on the measured beam distribution was proposed and applied in the accelerator complex at SESRI.In the experiment,the uniformity is successfully optimized from 75%to over 90%after five iterations of adjustment to the PS waveforms.In this paper,the method and experimental results were introduced.
文摘Prompt radiation emitted during accelerator operation poses a significant health risk,necessitating a thorough search and securing of hazardous areas prior to initiation.Currently,manual sweep methods are employed.However,the limitations of manual sweeps have become increasingly evident with the implementation of large-scale accelerators.By leveraging advancements in machine vision technology,the automatic identification of stranded personnel in controlled areas through camera imagery presents a viable solution for efficient search and security.Given the criticality of personal safety for stranded individuals,search and security processes must be sufficiently reliable.To ensure comprehensive coverage,180°camera groups were strategically positioned on both sides of the accelerator tunnel to eliminate blind spots within the monitoring range.The YOLOV8 network model was modified to enable the detection of small targets,such as hands and feet,as well as larger targets formed by individuals near the cameras.Furthermore,the system incorporates a pedestrian recognition model that detects human body parts,and an information fusion strategy is used to integrate the detected head,hands,and feet with the identified pedestrians as a cohesive unit.This strategy enhanced the capability of the model to identify pedestrians obstructed by equipment,resulting in a notable improvement in the recall rate.Specifically,recall rates of 0.915 and 0.82were obtained for Datasets 1 and 2,respectively.Although there was a slight decrease in accuracy,it aligned with the intended purpose of the search-and-secure software design.Experimental tests conducted within an accelerator tunnel demonstrated the effectiveness of this approach in achieving reliable recognition outcomes.
基金supported by the National Natural Science Foundation of China(Grant No.11975214).
文摘We present a first on-chip positron accelerator based on dielectric laser acceleration.This innovative approach significantly reduces the physical dimensions of the positron acceleration apparatus,enhancing its feasibility for diverse applications.By utilizing a stacked acceleration structure and far-infrared laser technology,we are able to achieve a seven-stage acceleration structure that surpasses the distance and energy gain of using the previous dielectric laser acceleration methods.Additionally,we are able to compress the positron beam to an ultrafast sub-femtosecond scale during the acceleration process,compared with the traditional methods,the positron beam is compressed to a greater extent.We also demonstrate the robustness of the stacked acceleration structure through the successful acceleration of the positron beam.
文摘The flexibility in radiotherapy can be improved if patients can be moved between any one of the department’s medical linear accelerators (LINACs) without the need to change anything in the patient’s treatment plan. For this to be possible, the dosimetric characteristics of the various accelerators must be the same, or nearly the same. The purpose of this work is to describe further and compare measurements and parameters after the initial vendor-recommended beam matching of the five LINACs. Deviations related to dose calculations and to beam matched accelerators may compromise treatment accuracy. The safest and most practical way to ensure that all accelerators are within clinical acceptable accuracy is to include TPS calculations in the LINACs matching evaluation. Treatment planning system (TPS) was used to create three photons plans with different field sizes 3 × 3 cm, 10 × 10 cm and 25 × 25 cm at a depth of 4.5 cm in Perspex. Calculated TPS plans were sent to Mosaiq to be delivered by five LINACs. TPS plans were compared with five LINACs measurements data using Gamma analyses of 2% and 2 mm. The results suggest that for four out of the five LINACs, there was generally good agreement, less than a 2% deviation between the planned dose distribution and the measured dose distribution. However, one specific LINAC named “Asterix” exhibited a deviation of 2.121% from the planned dose. The results show that all of the LINACs’ performance were within the acceptable deviation and delivering radiation dose consistently and accurately.
基金This work was supported by Open Fund Project of State Key Laboratory of Intelligent Vehicle Safety Technology by Grant with No.IVSTSKL-202311Key Projects of Science and Technology Research Programme of Chongqing Municipal Education Commission by Grant with No.KJZD-K202301505+1 种基金Cooperation Project between Chongqing Municipal Undergraduate Universities and Institutes Affiliated to the Chinese Academy of Sciences in 2021 by Grant with No.HZ2021015Chongqing Graduate Student Research Innovation Program by Grant with No.CYS240801.
文摘Massive computational complexity and memory requirement of artificial intelligence models impede their deploy-ability on edge computing devices of the Internet of Things(IoT).While Power-of-Two(PoT)quantization is pro-posed to improve the efficiency for edge inference of Deep Neural Networks(DNNs),existing PoT schemes require a huge amount of bit-wise manipulation and have large memory overhead,and their efficiency is bounded by the bottleneck of computation latency and memory footprint.To tackle this challenge,we present an efficient inference approach on the basis of PoT quantization and model compression.An integer-only scalar PoT quantization(IOS-PoT)is designed jointly with a distribution loss regularizer,wherein the regularizer minimizes quantization errors and training disturbances.Additionally,two-stage model compression is developed to effectively reduce memory requirement,and alleviate bandwidth usage in communications of networked heterogenous learning systems.The product look-up table(P-LUT)inference scheme is leveraged to replace bit-shifting with only indexing and addition operations for achieving low-latency computation and implementing efficient edge accelerators.Finally,comprehensive experiments on Residual Networks(ResNets)and efficient architectures with Canadian Institute for Advanced Research(CIFAR),ImageNet,and Real-world Affective Faces Database(RAF-DB)datasets,indicate that our approach achieves 2×∼10×improvement in the reduction of both weight size and computation cost in comparison to state-of-the-art methods.A P-LUT accelerator prototype is implemented on the Xilinx KV260 Field Programmable Gate Array(FPGA)platform for accelerating convolution operations,with performance results showing that P-LUT reduces memory footprint by 1.45×,achieves more than 3×power efficiency and 2×resource efficiency,compared to the conventional bit-shifting scheme.
文摘A compact 10 MeV S-band irradiation electron linear accelerator(linac)was developed to simulate electronic radiation in outer space and perform electron irradiation effect tests on spacecraft materials and devices.According to the requirements of space environment simulation,the electron beam energy can be adjusted in the range from 3.5 to 10 MeV,and the average current can be adjusted in the range from 0.1 to 1 mA.The linac should be capable of providing beam irradiation over a large area of 1 m^(2) with a uniformity greater than 90% and a scanning rate of 100 Hz.A novel method was applied to achieve such a high beam scanning rate by combining a kicker and a scanning magnet.Based on this requirement,a design for the10 MeV linac is proposed with an RF power pulse repetition rate of 500 Hz;it includes a thermal cathode electron gun,a bunching-accelerating section,and a scanning transport line.The detailed physical design and dynamic simulation results of the proposed 10 MeV electron linac are presented in this paper.
基金the National Key Research and Devecopment Program of China(No.2022YFB4501601)the National Natural Science Foundation of China(No.62102398,U20A20227,62222214,62002338,U22A2028,U19B2019)+1 种基金the Chinese Academy of Sciences Project for Young Scientists in Basic Research(YSBR-029)Youth Innovation Promotion Association Chinese Academy of Sciences。
文摘Quantized training has been proven to be a prominent method to achieve deep neural network training under limited computational resources.It uses low bit-width arithmetics with a proper scaling factor to achieve negligible accuracy loss.Cambricon-Q is the ASIC design proposed to efficiently support quantized training,and achieves significant performance improvement.However,there are still two caveats in the design.First,Cambricon-Q with different hardware specifications may lead to different numerical errors,resulting in non-reproducible behaviors which may become a major concern in critical applications.Second,Cambricon-Q cannot leverage data sparsity,where considerable cycles could still be squeezed out.To address the caveats,the acceleration core of Cambricon-Q is redesigned to support fine-grained irregular data processing.The new design not only enables acceleration on sparse data,but also enables performing local dynamic quantization by contiguous value ranges(which is hardware independent),instead of contiguous addresses(which is dependent on hardware factors).Experimental results show that the accuracy loss of the method still keeps negligible,and the accelerator achieves 1.61×performance improvement over Cambricon-Q,with about 10%energy increase.
文摘Molecular Dynamics(MD)simulation for computing Interatomic Potential(IAP)is a very important High-Performance Computing(HPC)application.MD simulation on particles of experimental relevance takes huge computation time,despite using an expensive high-end server.Heterogeneous computing,a combination of the Field Programmable Gate Array(FPGA)and a computer,is proposed as a solution to compute MD simulation efficiently.In such heterogeneous computation,communication between FPGA and Computer is necessary.One such MD simulation,explained in the paper,is the(Artificial Neural Network)ANN-based IAP computation of gold(Au_(147)&Au_(309))nanoparticles.MD simulation calculates the forces between atoms and the total energy of the chemical system.This work proposes the novel design and implementation of an ANN IAP-based MD simulation for Au_(147)&Au_(309) using communication protocols,such as Universal Asynchronous Receiver-Transmitter(UART)and Ethernet,for communication between the FPGA and the host computer.To improve the latency of MD simulation through heterogeneous computing,Universal Asynchronous Receiver-Transmitter(UART)and Ethernet communication protocols were explored to conduct MD simulation of 50,000 cycles.In this study,computation times of 17.54 and 18.70 h were achieved with UART and Ethernet,respectively,compared to the conventional server time of 29 h for Au_(147) nanoparticles.The results pave the way for the development of a Lab-on-a-chip application.
基金Supported by the National Key R&D Program of China(No.2022ZD0119001)the National Natural Science Foundation of China(No.61834005,61802304)+1 种基金the Education Department of Shaanxi Province(No.22JY060)the Shaanxi Provincial Key Research and Devel-opment Plan(No.2024GX-YBXM-100)。
文摘With the rapid development of deep learning algorithms,the computational complexity and functional diversity are increasing rapidly.However,the gap between high computational density and insufficient memory bandwidth under the traditional von Neumann architecture is getting worse.Analyzing the algorithmic characteristics of convolutional neural network(CNN),it is found that the access characteristics of convolution(CONV)and fully connected(FC)operations are very different.Based on this feature,a dual-mode reronfigurable distributed memory architecture for CNN accelerator is designed.It can be configured in Bank mode or first input first output(FIFO)mode to accommodate the access needs of different operations.At the same time,a programmable memory control unit is designed,which can effectively control the dual-mode configurable distributed memory architecture by using customized special accessing instructions and reduce the data accessing delay.The proposed architecture is verified and tested by parallel implementation of some CNN algorithms.The experimental results show that the peak bandwidth can reach 13.44 GB·s^(-1)at an operating frequency of 120 MHz.This work can achieve 1.40,1.12,2.80 and 4.70 times the peak bandwidth compared with the existing work.
文摘Deep neural networks(DNN)are widely used in image recognition,image classification,and other fields.However,as the model size increases,the DNN hardware accelerators face the challenge of higher area overhead and energy consumption.In recent years,stochastic computing(SC)has been considered a way to realize deep neural networks and reduce hardware consumption.A probabilistic compensation algorithm is proposed to solve the accuracy problem of stochastic calculation,and a fully parallel neural network accelerator based on a deterministic method is designed.The software simulation results show that the accuracy of the probability compensation algorithm on the CIFAR-10 data set is 95.32%,which is 14.98%higher than that of the traditional SC algorithm.The accuracy of the deterministic algorithm on the CIFAR-10 dataset is 95.06%,which is 14.72%higher than that of the traditional SC algorithm.The results of Very Large Scale Integration Circuit(VLSI)hardware tests show that the normalized energy efficiency of the fully parallel neural network accelerator based on the deterministic method is improved by 31%compared with the circuit based on binary computing.
基金supported by the National Natural Science Foundation of China(82071143,82371000,82270361)Key Research and Development Program of Jiangsu Province(BE2022795)+2 种基金the Postgraduate Research&Practice Innovation Program of Jiangsu Province(KYCX22_1801)the Jiangsu Province Capability Improvement Project through the Science,Technology and Education-Jiangsu Provincial Research Hospital Cultivation Unit(YJXYYJSDW4)Jiangsu Provincial Medical Innovation Center(CXZX202227).
文摘Corticotomy is a clinical procedure to accelerate orthodontic tooth movement characterized by the regional acceleratory phenomenon(RAP).Despite its therapeutic effects,the surgical risk and unclear mechanism hamper the clinical application.Numerous evidences support macrophages as the key immune cells during bone remodeling.Our study discovered that the monocyte-derived macrophages primarily exhibited a pro-inflammatory phenotype that dominated bone remodeling in corticotomy by CX3CR1CreERT2;R26GFP lineage tracing system.Fluorescence staining,flow cytometry analysis,and western blot determined the significantly enhanced expression of binding immunoglobulin protein(BiP)and emphasized the activation of sensor activating transcription factor 6(ATF6)in macrophages.Then,we verified that macrophage specific ATF6 deletion(ATF6f/f;CX3CR1CreERT2 mice)decreased the proportion of pro-inflammatory macrophages and therefore blocked the acceleration effect of corticotomy.In contrast,macrophage ATF6 overexpression exaggerated the acceleration of orthodontic tooth movement.In vitro experiments also proved that higher proportion of pro-inflammatory macrophages was positively correlated with higher expression of ATF6.At the mechanism level,RNA-seq and CUT&Tag analysis demonstrated that ATF6 modulated the macrophage-orchestrated inflammation through interacting with Tnfαpromotor and augmenting its transcription.Additionally,molecular docking simulation and dual-luciferase reporter system indicated the possible binding sites outside of the traditional endoplasmic reticulum-stress response element(ERSE).Taken together,ATF6 may aggravate orthodontic bone remodeling by promoting Tnfαtranscription in macrophages,suggesting that ATF6 may represent a promising therapeutic target for non-invasive accelerated orthodontics.
基金the National Research Institute of Astronomy and Geophysics (NRIAG) for supporting this work
文摘The level of ground shaking,as determined by the peak ground acceleration(PGA),can be used to analyze seismic hazard at a certain location and is crucial for constructing earthquake-resistant structures.Predicting the PGA immediately after an earthquake occurs allows for the issuing of a warning by an earthquake early warning system.In this study,we propose a deep learning model,ConvMixer,to predict the PGA recorded by weak-motion velocity seismometers in Japan.We use 5-s threecomponent seismograms,from 2 s before until 3 s after the P-wave arrival time of the earthquake.Our dataset comprised more than 50,000 single-station waveforms recorded by 10 seismic stations in the K-NET,Kiki-NET,and Hi-Net networks between 2004 and 2023.The proposed ConvMixer is a patch-based model that extracts global features from input seismic data and predicts the PGA of an earthquake by combining depth and pointwise convolutions.The proposed ConvMixer network had a mean absolute error of 2.143 when applied to the test set and outperformed benchmark deep learning models.In addition,the proposed ConvMixer demonstrated the ability to predict the PGA at the corresponding station site based on 1-second waveforms obtained immediately after the arrival time of the P-wave.
基金supported by the National Institute for Health Research (NIHR) Leicester Biomedical Research Centre and NIHR Applied Research Collaboration East Midlands (ARC EM, (IS-BRC-1215-20010))funded by the National Institute for Health and Care Research Bristol Biomedical Research Centre (IS-BRC-1215-20011)supported by a UKRI research grant (EP/X042464/1)。
文摘Background Higher accelerometer-assessed volume and intensity of physical activity(PA)have been associated with a longer life expectancy but can be difficult to translate into recommended doses of PA.We aimed to:(a)improve interpretability by producing UK Biobank age-referenced centiles for PA volume and intensity;(b)inform public-health messaging by examining how adding recommended quantities of moderate and vigorous PA affect PA volume and intensity.Methods 92,480 UK Biobank participants aged 43-80 years with wrist-worn accelerometer data were included.Average acceleration and intensity gradient were derived as proxies for PA volume and intensity.We generated sex-specific centile curves using Generalized Additive Models for Location Scale and Shape(GAMLSS)and modeled the effect of adding moderate(walking)or vigorous(running)activity on the combined change in the volume and intensity centiles(change in PA profile).Results In men,volume was lower as age increased while intensity was lower after age 55;in women,both volume and intensity were lower as age increased.Adding 150 min of moderate PA weekly(5×30 min walking)increased the PA profile by 4 percentage points.Defining moderate PA as brisk walking approximately doubled the increase(9 percentage points)while 75 min of vigorous PA weekly(5×15 min running)trebled the increase(13 percentage points).Conclusion These UK Biobank reference centiles provide a benchmark for interpretation of accelerometer data.Application of our translational methods demonstrate that meeting PA guidelines through shorter duration vigorous activity is more beneficial to the PA profile(volume and intensity)than longer duration moderate activity.
基金supported by the National Natural Science Foundation of China (Grant No. 12372028)the National Key Research and Development Program of China (Grant No. 2020YFC2201101)the Guangdong Basic and Applied Basic Research Foundation (Grant No.2022A1515011809)。
文摘The harmonic balance method(HBM)has been widely applied to get the periodic solution of nonlinear systems,however,its convergence rate as well as computation efficiency is dramatically degraded when the system is highly non-smooth,e.g.,discontinuous.In order to accelerate the convergence,an enriched HBM is developed in this paper where the non-smooth Bernoulli bases are additionally introduced to enrich the conventional Fourier bases.The basic idea behind is that the convergence rate of the HB solution,as a truncated Fourier series,can be improved if the smoothness of the solution becomes finer.Along this line,using non-smooth Bernoulli bases can compensate the highly non-smooth part of the solution and then,the smoothness of the residual part for Fourier approximation is improved so as to achieve accelerated convergence.Numerical examples are conducted on systems with non-smooth restoring and/or external forces.The results confirm that the proposed enriched HBM indeed increases the convergence rate and the increase becomes more significant if more non-smooth bases are used.