In this paper, poly (acrylamide-co-acrylic acid) (P(AM-co-AA)) hydrogel was pre- pared in an aqueous solution by using glow-discharge electrolysis plasma (GDEP) induced copoly- merization of acrylamide (AM) ...In this paper, poly (acrylamide-co-acrylic acid) (P(AM-co-AA)) hydrogel was pre- pared in an aqueous solution by using glow-discharge electrolysis plasma (GDEP) induced copoly- merization of acrylamide (AM) and acrylic acid (AA), in which N,N'-methylenebisacrylamide (MBA) was used as a crosslinker. A mechanism for the synthesis of P(AM-co-AA) hydrogel was proposed. To optimize the synthesis condition, the following parameters were examined in detail: the discharge voltage, discharge time, the content of the crosslinker, and the mass ratio of AM to AA. The results showed that the optimum pH range for cationic dyes removal was found to be 5.0-10.0. The P(AM-co-AA) hydrogel exhibits a very high adsorption potential and the ex- perimental adsorption capacities for Crystal violet (CV) and Methylene blue (MB) were 2974.3 mg/g and 2303.6 mg/g, respectively. The adsorption process follows a pseudo-second-order kinetic model. In addition, the adsorption mechanism of P(AM-co-AA) hydrogel for cationic dyes was also discussed.展开更多
We perform the theoretical simulation of the concentric-ring patterns between two parallel electrodes covered with thin dielectric layers within the scope of a two-dimensional diffusion-drift model at atmospheric pres...We perform the theoretical simulation of the concentric-ring patterns between two parallel electrodes covered with thin dielectric layers within the scope of a two-dimensional diffusion-drift model at atmospheric pressure. The time evolution of the discharge patterns is studied and the concentric-ring patterns with different radii shift alternately. The spatial-temporal evolution of electron density in a cycle at different time scales is performed.展开更多
In this paper, we study the characteristics of atmospheric-pressure pulsed dielectric barrier discharge (DBD) under the needle-plate electrode configuration using a one-dimensional self-consistent fluid model. The r...In this paper, we study the characteristics of atmospheric-pressure pulsed dielectric barrier discharge (DBD) under the needle-plate electrode configuration using a one-dimensional self-consistent fluid model. The results show that, the DBDs driven by positive pulse, negative pulse and bipolar pulse possess different behaviors. Moreover, the two discharges appearing at the rising and the falling phases of per voltage pulse also have different discharge regimes. For the case of the positive pulse, the breakdown field is much lower than that of the negative pulse, and its propagation characteristic is different from the negative pulse DBD. When the DBD is driven by a bipolar pulse voltage, there exists the interaction between the positive and negative pulses, resulting in the decrease of the breakdown field of the negative pulse DBD and causing the change of the discharge behaviors. In addition, the effects of the discharge parameters on the behaviors of pulsed DBD in the needle-plate electrode configuration are also studied.展开更多
The ambipolar diffusion and argon ion mobility as functions of the reduced electric field and pressure times the tube radius are investigated in a weakly ionized non-uniform glow discharge plasma system. In particular...The ambipolar diffusion and argon ion mobility as functions of the reduced electric field and pressure times the tube radius are investigated in a weakly ionized non-uniform glow discharge plasma system. In particular, the variable cross section at the same discharge tube on the ambipolar diffusion coefficient shows a more noticeable effect than the effects from the ion mobility. As the diffusion length A increases, the ambipolar diffusion Da increases. However, it decreases as the discharge current is increased.展开更多
基金supported by National Natural Science Foundation of China(No.21367023)Natural Science Foundation of Gansu Province,China(No.1208RJZA161)Key Project of Young Teachers’ Scientific Research Promotion of Northwest Normal University of China(Nos.NWNU-LKQN-10-16 and NWNU-LKQN-12-9)
文摘In this paper, poly (acrylamide-co-acrylic acid) (P(AM-co-AA)) hydrogel was pre- pared in an aqueous solution by using glow-discharge electrolysis plasma (GDEP) induced copoly- merization of acrylamide (AM) and acrylic acid (AA), in which N,N'-methylenebisacrylamide (MBA) was used as a crosslinker. A mechanism for the synthesis of P(AM-co-AA) hydrogel was proposed. To optimize the synthesis condition, the following parameters were examined in detail: the discharge voltage, discharge time, the content of the crosslinker, and the mass ratio of AM to AA. The results showed that the optimum pH range for cationic dyes removal was found to be 5.0-10.0. The P(AM-co-AA) hydrogel exhibits a very high adsorption potential and the ex- perimental adsorption capacities for Crystal violet (CV) and Methylene blue (MB) were 2974.3 mg/g and 2303.6 mg/g, respectively. The adsorption process follows a pseudo-second-order kinetic model. In addition, the adsorption mechanism of P(AM-co-AA) hydrogel for cationic dyes was also discussed.
基金Supported by the National Natural Science Foundation of China under Grant Nos 50537020 and 50528707.
文摘We perform the theoretical simulation of the concentric-ring patterns between two parallel electrodes covered with thin dielectric layers within the scope of a two-dimensional diffusion-drift model at atmospheric pressure. The time evolution of the discharge patterns is studied and the concentric-ring patterns with different radii shift alternately. The spatial-temporal evolution of electron density in a cycle at different time scales is performed.
基金supported by National Natural Science Foundation of China(No.11405022)
文摘In this paper, we study the characteristics of atmospheric-pressure pulsed dielectric barrier discharge (DBD) under the needle-plate electrode configuration using a one-dimensional self-consistent fluid model. The results show that, the DBDs driven by positive pulse, negative pulse and bipolar pulse possess different behaviors. Moreover, the two discharges appearing at the rising and the falling phases of per voltage pulse also have different discharge regimes. For the case of the positive pulse, the breakdown field is much lower than that of the negative pulse, and its propagation characteristic is different from the negative pulse DBD. When the DBD is driven by a bipolar pulse voltage, there exists the interaction between the positive and negative pulses, resulting in the decrease of the breakdown field of the negative pulse DBD and causing the change of the discharge behaviors. In addition, the effects of the discharge parameters on the behaviors of pulsed DBD in the needle-plate electrode configuration are also studied.
文摘The ambipolar diffusion and argon ion mobility as functions of the reduced electric field and pressure times the tube radius are investigated in a weakly ionized non-uniform glow discharge plasma system. In particular, the variable cross section at the same discharge tube on the ambipolar diffusion coefficient shows a more noticeable effect than the effects from the ion mobility. As the diffusion length A increases, the ambipolar diffusion Da increases. However, it decreases as the discharge current is increased.