Theoretical and Experimental Study on Ground Coupled Heat Pump with Vertical Spiral Coil 被引量:4
1
作者 李新国 周倩 +2 位作者 赵军 朱强 胡璟 《Transactions of Tianjin University》 EI CAS 2003年第2期123-126,共4页
The numeric al simulation study on the temperature distribution of underground field for the ground coupled heat pump (GCHP) with vertical spira l coil was carried out by using finite element. The distribution and rec... The numeric al simulation study on the temperature distribution of underground field for the ground coupled heat pump (GCHP) with vertical spira l coil was carried out by using finite element. The distribution and recovery of undergroun d field temperature under different operation ratio and the optimal operation ratio were simulated.The performance parameters, i.e. inlet and outlet temperature of the ground spiral coil in heating and cooling modes were tested, the heat extracted or emitted by the heat pump to the ground was calculated, and the coefficients of performance (COP) of GCHP at heat ing and cooling modes were analyzed. 展开更多
关键词 ground coupled heat pump (GCHP) vert ic al spiral coil underground temperature distribution optimal operation ratio
在线阅读 下载PDF
严寒地区办公建筑土壤源热泵系统运行策略优化研究 被引量:2
2
作者 刘馨 鲁倩男 +3 位作者 梁传志 冯国会 陈海洋 李画 《建筑科学》 CSCD 北大核心 2021年第8期79-86,共8页
严寒地区仅以供热为主的建筑在长期的连续运行或冷热负荷不平衡的条件下,对土壤源热泵(GCHP)机组的运行特性会产生负面的影响。通过改变和调节不同的运行策略,系统的运行特性会有较为明显的改善。本文以某办公建筑的土壤源热泵系统为研... 严寒地区仅以供热为主的建筑在长期的连续运行或冷热负荷不平衡的条件下,对土壤源热泵(GCHP)机组的运行特性会产生负面的影响。通过改变和调节不同的运行策略,系统的运行特性会有较为明显的改善。本文以某办公建筑的土壤源热泵系统为研究对象,通过对系统连续2 a供暖季的长期监测,采集系统的运行数据,利用采暖度日数对室外温度进行修正,分析实例建筑中土壤源热泵系统的水温特性、能效指标、室内供暖效果等因素,对比土壤源热泵系统在不同运行策略下的运行特性,探究系统不同年份不同运行策略的优劣,使其高效节能;并利用熵权法和遗传算法,计算影响系统运行特性因素的指标权重,从而寻求土壤源热泵系统最优的运行策略。结果表明,通过实测得出采用单台机组以不同负载率运行时,热泵机组COP平均提高1.15,系统EER平均提高0.46,主机耗电量降低8.3%,系统耗电量降低10.8%,节能效果均提升20%左右;遗传算法求解最优运行策略各参数值,3月运行效果最优,地源侧循环水流量为21.99 m^(3)/h,用户侧循环水流量为79m^(3)/h,地源侧进水温度为5.78℃,用户侧出水温度为34.49℃。 展开更多
关键词 土壤源热泵(GCHP)系统 供暖度日数 运行特性 熵权法 遗传算法