期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
THE PREPARATION OF ISOPOLYMOLYBDIC ACID-POLYANILINE FILM MODIFIED ELECTRODE AND ITS CATALYTIC EFFECTS ON CHLORATE IONS
1
作者 Shao Jun DONG Bao Xing WANG Fa Yi SONG Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Academia Sinica, Changchun Jilin 130022 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第5期411-414,共4页
The preparation method of H_4MoO_(26)-polyaniline film modified electrode and its voltammetric behaviour are described. The modified electrode has high electrocatalytic activity on chlorate ions.
关键词 rate THE PREPARATION OF ISOPOLYMOLYBDIC ACID-POLYANILINE film modified electrode AND ITS CATALYTIC EFFECTS ON CHLORATE IONS ACID ITS
在线阅读 下载PDF
Fabrication of the DNA/poly(3-methylthiophene) composite film modified electrode and its application for the study on the voltammetric behavior and determination of 8-hydroxy-2'-deoxyguanosine 被引量:2
2
作者 WANG YanHuai LI Jing +4 位作者 LIU Yan MA RongNa JIA WenLi CUI Hui WANG HuaiSheng 《Science China Chemistry》 SCIE EI CAS 2009年第11期2006-2012,共7页
A composite film of DNA/poly(3-methylthiophene)(P3MT)modified glassy carbon electrode(GCE)has been fabricated by electro-deposition method.P3MT film was first electropolymerized at the GCE and the DNA layer was then i... A composite film of DNA/poly(3-methylthiophene)(P3MT)modified glassy carbon electrode(GCE)has been fabricated by electro-deposition method.P3MT film was first electropolymerized at the GCE and the DNA layer was then immobilized on the P3MT layer by electrochemical method.The voltammetric behavior of 8-hydroxy-2'-deoxyguanosine(8-OH-dG)at the composite film modified electrode was studied.The effects of scan rates,pH and the interference of uric acid(UA)on the voltammetric behavior and detection of 8-OH-dG were also discussed.The experimental results suggest that the electrochemical behavior of 8-OH-dG at the composite film modified electrode was greatly improved due to the combination of the advantages of P3MT and DNA.In 0.1 M pH 7.0 phosphate buffer solution(PBS),the anodic peak currents of 8-OH-dG were linear with the 8-OH-dG concentration in two intervals,viz.0.28―4.2μM and 4.2―19.6μM.The detection limit of 56 nM 8-OH-dG could be estimated(S/N=3).This proposed composite film modified electrode shows excellent reproducibility and stability.It may have the potential application for the detection of 8-OH-dG in human urine. 展开更多
关键词 poly(3-methylthiophene) DNA 8-hydroxy-2'-deoxyguanosine composite film modified electrode
原文传递
Abnormal IR Spectra of CO Adsorbed on the Surface of Glass Carbon Electrode Modified with Polypyrrole Film with Platinum Microparticles
3
作者 Hui YANG Tian Bong LU +3 位作者 Kuau Hong XUE Guo Qiang LU Shen Pei CHEN Shi Gang SUN(ChangChun Institute of Applied Chemistry, Chinese Academy of Scierees, Changchun 130022)(Department of Chemistry, Nanjing Normal Universty, Nanjing 210097)(Department of Chemi 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第4期343-344,共2页
Abnormal IR spectra of CO adsorbed at the surface of glass carbon electrode modified with polypyrrole film with Pt microparticles are reported.
关键词 Abnormal IR Spectra of CO Adsorbed on the Surface of Glass Carbon electrode modified with Polypyrrole film with Platinum Microparticles CO IR
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部