Objective: To evaluate the energetic profile of fetal fluids and to make comparisons of the concentrations of the constituents present with those in the maternal plasma.Methods: A study was conducted in 102 gravid she...Objective: To evaluate the energetic profile of fetal fluids and to make comparisons of the concentrations of the constituents present with those in the maternal plasma.Methods: A study was conducted in 102 gravid sheep uteri. The four stages of gestation as Stage I(0–60 days), Stage II(61–90 days), Stage III(91–120 days) and Stage IV(121–145 days) were identified based on the crown anus length of the embryo/fetus. The amniotic and allantoic fluids collected from the gravid uteri of each group were subjected to biochemical analysis of glucose, cholesterol and triglyceride.Results: The levels of glucose and triglyceride in maternal plasma were lower(P < 0.05)on late pregnancy as well as in amniotic and allantoic fluids. No significant variation(P > 0.05) of plasma cholesterol levels was detected between the sampling periods.Contrariwise, cholesterol concentrations of fetal fluids were higher in Stages III and IV of pregnancy when compared with the Stages I and II.Conclusions: The influence of pregnancy on the biochemical composition of fetal fluids was statistically significant.展开更多
Objective:To study the relationship between leptin concentration and fetal growth.Methods: Levels of leptin in maternal serum, amniotic fluid, arterial and venouscord blood of 65 normal parturients (gestational age 37...Objective:To study the relationship between leptin concentration and fetal growth.Methods: Levels of leptin in maternal serum, amniotic fluid, arterial and venouscord blood of 65 normal parturients (gestational age 37-42weeks) were measured by ra-dioimmunoassay (RIA) method. At the same time, maternal blood lipids were detected.Neonates were divided into three groups: small for gestational age (SGA) group (n=10), appropriate for gestational age (AGA) group (n=45), large for gestational age(LGA) group (n= 10). Statistical analysis was performed by t test, variance analysisand correlation analysis.Results: (1) There was no obvious correlation between leptin concentrations in ma-ternal serum and arterial/ venous cord blood, amniotic fluid, and also no correlationwith birth weight and placental weight (P>0.05). Maternal body mass index signifi-cantly correlated with birth weight and neonatal length and leptin levels in arterial andvenous cord blood (P<0.01). Leptin levels in arterial and venous cord blood positivelycorrelated significantly with placental and neonatal weight and body length (P<0.01)and negatively correlated with high density lipoprotein (P<0. 01). There was no obvi-ous correlation between fetal gender and leptin concentrations in maternal serum, arteri-al and venous cord blood and amniotic fluid; (2) Leptin levels in arterial and venouscord blood , placental weight in LGA group were significantly higher than those in SGAand AGA group (P<0.05). Among three groups, leptin concentrations in maternalblood were significantly higher than those in arterial and venous cord blood (P<0.05).Conclusions: (1)Fetal leptin is synthesized in uterus, born of itself and placenta.Leptin levels in arterial and venous cord blood are related to the intrauterine growthpattern. It might positively regulate birth weight and body fat content. (2)Either mater-nal or fetal leptin was not correlated with fetal gender. There is no gender difference infetal leptin concentrations.展开更多
Background: Amniotic fluid turbidity increases with fetal lung maturation due to vernix and lung surfactant micelles suspended in the amniotic fluid. This study focused on this phenomenon and evaluated the presence or...Background: Amniotic fluid turbidity increases with fetal lung maturation due to vernix and lung surfactant micelles suspended in the amniotic fluid. This study focused on this phenomenon and evaluated the presence or absence of respiratory distress syndrome (RDS)/transient tachypnea of the newborn (TTN) by quantitatively assessing the brightness of the amniotic fluid turbidity using a noninvasive ultrasound histogram measurement function. Methods: We included cases of singleton pregnancies managed at the Niigata University Medical and Dental Hospital between November 2020 and March 2022. Histograms of amniotic fluid turbidity were measured at the center of the amniotic fluid depth, avoiding the fetus, placenta, and umbilical cord, with the gain setting set to 0, and the average value was obtained after three measurements. Histograms of fetal urine in the bladder were measured similarly. The value obtained by subtracting the fetal bladder brightness value from the amniotic brightness value based on histogram measurements was used as the final amniotic fluid brightness value. Results: We included 118 cases (16 of RDS/TTN and 102 of control). The gestational age of delivery weeks was correlated with amniotic fluid brightness (Spearman’s rank correlation coefficient was 0.344;p = 0.00014). Amniotic fluid brightness values were significantly lower in the RDS/TTN group than in the control group (RDS/TTN: 16.2 ± 13.5, control: 26.3 ± 16.3;p = 0.020). The optimal cutoff value of amniotic fluid brightness to predict RDS/TTN was 20.3. For predicting RDS/TTN, the sensitivity, specificity, positive predictive value, and negative predictive value were 91.7%, 69.6%, 26.2%, and 94.1%, respectively. Conclusions: The quantitative value of the amniotic fluid brightness by histogram measurements may provide an easy and objective index for evaluating the presence or absence of RDS/TTN.展开更多
Objectives: Evaluation of diagnostic performance of rapid testing of cervico-vaginal fluid (CVF) for fetal fibronectin (FFN) and placental α-microglobulin 1 (PAMG-1) as screening of women presented by threatened pret...Objectives: Evaluation of diagnostic performance of rapid testing of cervico-vaginal fluid (CVF) for fetal fibronectin (FFN) and placental α-microglobulin 1 (PAMG-1) as screening of women presented by threatened preterm labor (TPTL) with intact membranes for duration till getting spontaneous labor (SL). Patients & Methods: 37 women presenting with TPTL underwent CVF samplings before digital examination and then underwent transvaginal ultrasonography for estimation of cervical length (CL). All women received fluid and anxiolytic therapy and if uterine contractions persisted, all had received tocolytic therapy with oral nifedipine or intravenous magnesium sulphate according to requirements. Incidence of SL within Results: Incidence of SL was 13.5%, 35.2% and 51.3% within 48-hr, 2 - 7 and 7 - 14 days, respectively. Duration till labor after sampling was positively correlated with CL, while was negatively correlated with positive FFN and PAMG-1 tests. Positive FFN test had high specificity, while positive PAMG-1 test had high sensitivity for labor within 7 days. Regression analysis defined short CL and positive PAMG-1 test as significant predictors for short duration till SL. ROC curve analysis defined short cervix and positive PAMG-1 test as significant predictors for labor within 48-hr and within 2 - 7 days respectively and combined negative PAMG-1 test and CL of 20 - 25 mm were significant predictors for labor within 7 - 14 days. Conclusion: PAMG-1 test had high specificity, if positive, for predicting SL and high NPP, if negative, for excluding labor within 7 days, so it can be used as rapid adjuvant to clinical evaluation to help management decision-making. Moreover, PAMG-1 test is recommended screening test for being easy-to-use bedside test, provides rapid results, can be used after vaginal exam and coitus and does not require a speculum examination or specialized equipment to analyze results.展开更多
A 39-year-old 34-week-pregnant woman was referred to our hospital for preterm labor and fetal dysfunction. Fetal middle cerebral artery systolic maximum blood flow velocity was high, so fetal anemia was suspected. Blo...A 39-year-old 34-week-pregnant woman was referred to our hospital for preterm labor and fetal dysfunction. Fetal middle cerebral artery systolic maximum blood flow velocity was high, so fetal anemia was suspected. Blood type was O-type Rh (+) and fetal hemoglobin was 0.4%;tests for irregular antibody and human parvovirus B19 IgM were negative. A high brightness echoic mass was observed in fetal stomach bubble, and amniotic fluid appeared bright. Labor suppression was disabled, and emergency cesarean section was performed. Amniotic fluid turbidity was observed, and on suctioning the stomach content of the infant, turbid amniotic fluid containing blood was obtained. On placental pathological examination, the cause of bloody amniotic fluid was not identified. The infant’s hemoglobin level was low at 8.7 g/dL, so the infant received red cell concentrate, with improvement of general condition.展开更多
文摘Objective: To evaluate the energetic profile of fetal fluids and to make comparisons of the concentrations of the constituents present with those in the maternal plasma.Methods: A study was conducted in 102 gravid sheep uteri. The four stages of gestation as Stage I(0–60 days), Stage II(61–90 days), Stage III(91–120 days) and Stage IV(121–145 days) were identified based on the crown anus length of the embryo/fetus. The amniotic and allantoic fluids collected from the gravid uteri of each group were subjected to biochemical analysis of glucose, cholesterol and triglyceride.Results: The levels of glucose and triglyceride in maternal plasma were lower(P < 0.05)on late pregnancy as well as in amniotic and allantoic fluids. No significant variation(P > 0.05) of plasma cholesterol levels was detected between the sampling periods.Contrariwise, cholesterol concentrations of fetal fluids were higher in Stages III and IV of pregnancy when compared with the Stages I and II.Conclusions: The influence of pregnancy on the biochemical composition of fetal fluids was statistically significant.
文摘Objective:To study the relationship between leptin concentration and fetal growth.Methods: Levels of leptin in maternal serum, amniotic fluid, arterial and venouscord blood of 65 normal parturients (gestational age 37-42weeks) were measured by ra-dioimmunoassay (RIA) method. At the same time, maternal blood lipids were detected.Neonates were divided into three groups: small for gestational age (SGA) group (n=10), appropriate for gestational age (AGA) group (n=45), large for gestational age(LGA) group (n= 10). Statistical analysis was performed by t test, variance analysisand correlation analysis.Results: (1) There was no obvious correlation between leptin concentrations in ma-ternal serum and arterial/ venous cord blood, amniotic fluid, and also no correlationwith birth weight and placental weight (P>0.05). Maternal body mass index signifi-cantly correlated with birth weight and neonatal length and leptin levels in arterial andvenous cord blood (P<0.01). Leptin levels in arterial and venous cord blood positivelycorrelated significantly with placental and neonatal weight and body length (P<0.01)and negatively correlated with high density lipoprotein (P<0. 01). There was no obvi-ous correlation between fetal gender and leptin concentrations in maternal serum, arteri-al and venous cord blood and amniotic fluid; (2) Leptin levels in arterial and venouscord blood , placental weight in LGA group were significantly higher than those in SGAand AGA group (P<0.05). Among three groups, leptin concentrations in maternalblood were significantly higher than those in arterial and venous cord blood (P<0.05).Conclusions: (1)Fetal leptin is synthesized in uterus, born of itself and placenta.Leptin levels in arterial and venous cord blood are related to the intrauterine growthpattern. It might positively regulate birth weight and body fat content. (2)Either mater-nal or fetal leptin was not correlated with fetal gender. There is no gender difference infetal leptin concentrations.
文摘Background: Amniotic fluid turbidity increases with fetal lung maturation due to vernix and lung surfactant micelles suspended in the amniotic fluid. This study focused on this phenomenon and evaluated the presence or absence of respiratory distress syndrome (RDS)/transient tachypnea of the newborn (TTN) by quantitatively assessing the brightness of the amniotic fluid turbidity using a noninvasive ultrasound histogram measurement function. Methods: We included cases of singleton pregnancies managed at the Niigata University Medical and Dental Hospital between November 2020 and March 2022. Histograms of amniotic fluid turbidity were measured at the center of the amniotic fluid depth, avoiding the fetus, placenta, and umbilical cord, with the gain setting set to 0, and the average value was obtained after three measurements. Histograms of fetal urine in the bladder were measured similarly. The value obtained by subtracting the fetal bladder brightness value from the amniotic brightness value based on histogram measurements was used as the final amniotic fluid brightness value. Results: We included 118 cases (16 of RDS/TTN and 102 of control). The gestational age of delivery weeks was correlated with amniotic fluid brightness (Spearman’s rank correlation coefficient was 0.344;p = 0.00014). Amniotic fluid brightness values were significantly lower in the RDS/TTN group than in the control group (RDS/TTN: 16.2 ± 13.5, control: 26.3 ± 16.3;p = 0.020). The optimal cutoff value of amniotic fluid brightness to predict RDS/TTN was 20.3. For predicting RDS/TTN, the sensitivity, specificity, positive predictive value, and negative predictive value were 91.7%, 69.6%, 26.2%, and 94.1%, respectively. Conclusions: The quantitative value of the amniotic fluid brightness by histogram measurements may provide an easy and objective index for evaluating the presence or absence of RDS/TTN.
文摘Objectives: Evaluation of diagnostic performance of rapid testing of cervico-vaginal fluid (CVF) for fetal fibronectin (FFN) and placental α-microglobulin 1 (PAMG-1) as screening of women presented by threatened preterm labor (TPTL) with intact membranes for duration till getting spontaneous labor (SL). Patients & Methods: 37 women presenting with TPTL underwent CVF samplings before digital examination and then underwent transvaginal ultrasonography for estimation of cervical length (CL). All women received fluid and anxiolytic therapy and if uterine contractions persisted, all had received tocolytic therapy with oral nifedipine or intravenous magnesium sulphate according to requirements. Incidence of SL within Results: Incidence of SL was 13.5%, 35.2% and 51.3% within 48-hr, 2 - 7 and 7 - 14 days, respectively. Duration till labor after sampling was positively correlated with CL, while was negatively correlated with positive FFN and PAMG-1 tests. Positive FFN test had high specificity, while positive PAMG-1 test had high sensitivity for labor within 7 days. Regression analysis defined short CL and positive PAMG-1 test as significant predictors for short duration till SL. ROC curve analysis defined short cervix and positive PAMG-1 test as significant predictors for labor within 48-hr and within 2 - 7 days respectively and combined negative PAMG-1 test and CL of 20 - 25 mm were significant predictors for labor within 7 - 14 days. Conclusion: PAMG-1 test had high specificity, if positive, for predicting SL and high NPP, if negative, for excluding labor within 7 days, so it can be used as rapid adjuvant to clinical evaluation to help management decision-making. Moreover, PAMG-1 test is recommended screening test for being easy-to-use bedside test, provides rapid results, can be used after vaginal exam and coitus and does not require a speculum examination or specialized equipment to analyze results.
文摘A 39-year-old 34-week-pregnant woman was referred to our hospital for preterm labor and fetal dysfunction. Fetal middle cerebral artery systolic maximum blood flow velocity was high, so fetal anemia was suspected. Blood type was O-type Rh (+) and fetal hemoglobin was 0.4%;tests for irregular antibody and human parvovirus B19 IgM were negative. A high brightness echoic mass was observed in fetal stomach bubble, and amniotic fluid appeared bright. Labor suppression was disabled, and emergency cesarean section was performed. Amniotic fluid turbidity was observed, and on suctioning the stomach content of the infant, turbid amniotic fluid containing blood was obtained. On placental pathological examination, the cause of bloody amniotic fluid was not identified. The infant’s hemoglobin level was low at 8.7 g/dL, so the infant received red cell concentrate, with improvement of general condition.