A false alarm fault frequently appeared in antenna-servo system of the CINRAD/SA weather radar of Shanwei in the second half of 2011, so possible reasons for the false alarm fault were listed firstly using method of e...A false alarm fault frequently appeared in antenna-servo system of the CINRAD/SA weather radar of Shanwei in the second half of 2011, so possible reasons for the false alarm fault were listed firstly using method of exhaustion, and then the main reason was determined using exclusive method. That is, the fault was closely related to the signal transmission channel from the antenna mount to servo system in RDA cabinet. After ex- amining questionable nodes in the transmission channels of the alarm signal, we found that the false alarm fault might result from the interference of a burr in the temperature sensing circuit of the elevation motor. In actual operation, a filter capacitor was connected with the corresponding pin in the upper optical board to screen the interference of a burr, thereby successfully eliminating the false alarm fault in antenna-servo system of the CIN- RAD/SA radar of Shanwei.展开更多
Quantized fault detection for sensor/actuator faults of networked control systems (NCSs) with time delays both in the sensor-to-controller channel and controller-to-actuator channel is concerned in this paper. A fau...Quantized fault detection for sensor/actuator faults of networked control systems (NCSs) with time delays both in the sensor-to-controller channel and controller-to-actuator channel is concerned in this paper. A fault model is set up based on the possible cases of sensor/atuator faults. Then, the model predictive control is used to compensate the time delay. When the sensors and actuators are healthy, an H stability criterion of the state predictive observer is obtained in terms of linear matrix inequality. A new threshold computational method that conforms to the actual situation is proposed. Then, the thresholds of the false alarm rate (FAR) and miss detection rate (MDR) are presented by using our proposed method, which are also compared with the ones given in the existin~ literatures. Finally, some numerical simulations are shown to demonstrate the effectiveness of the proposed method.展开更多
Diagnosing intermittent fault is an important approach to reduce built-in test(BIT) false alarms. Aiming at solving the shortcoming of the present diagnostic method of intermittent fault, and according to the merit ...Diagnosing intermittent fault is an important approach to reduce built-in test(BIT) false alarms. Aiming at solving the shortcoming of the present diagnostic method of intermittent fault, and according to the merit of support vector machines ( SVM) which can be trained with a small-sample, an SVM-based diagnostic model of 3 states that include OK state, intermittent state and faulty state is presented. With the features based on the reflection coefficients of an alarm rate ( AR ) model extracted from small vibration samples, these models are trained to diagnose intermittent faults. The experimental results show that this method can diagnose multiple intermittent faults accurately with small training samples and BIT false alarms are reduced.展开更多
文摘A false alarm fault frequently appeared in antenna-servo system of the CINRAD/SA weather radar of Shanwei in the second half of 2011, so possible reasons for the false alarm fault were listed firstly using method of exhaustion, and then the main reason was determined using exclusive method. That is, the fault was closely related to the signal transmission channel from the antenna mount to servo system in RDA cabinet. After ex- amining questionable nodes in the transmission channels of the alarm signal, we found that the false alarm fault might result from the interference of a burr in the temperature sensing circuit of the elevation motor. In actual operation, a filter capacitor was connected with the corresponding pin in the upper optical board to screen the interference of a burr, thereby successfully eliminating the false alarm fault in antenna-servo system of the CIN- RAD/SA radar of Shanwei.
基金supported by National Natural Science Foundation of China(No.61074065)Natural Science Foundation of Hebei Province(No.F2012203184)Specialized Research Fund for the Doctoral Program of Higher Education of China(No.20111333120009)
文摘Quantized fault detection for sensor/actuator faults of networked control systems (NCSs) with time delays both in the sensor-to-controller channel and controller-to-actuator channel is concerned in this paper. A fault model is set up based on the possible cases of sensor/atuator faults. Then, the model predictive control is used to compensate the time delay. When the sensors and actuators are healthy, an H stability criterion of the state predictive observer is obtained in terms of linear matrix inequality. A new threshold computational method that conforms to the actual situation is proposed. Then, the thresholds of the false alarm rate (FAR) and miss detection rate (MDR) are presented by using our proposed method, which are also compared with the ones given in the existin~ literatures. Finally, some numerical simulations are shown to demonstrate the effectiveness of the proposed method.
文摘Diagnosing intermittent fault is an important approach to reduce built-in test(BIT) false alarms. Aiming at solving the shortcoming of the present diagnostic method of intermittent fault, and according to the merit of support vector machines ( SVM) which can be trained with a small-sample, an SVM-based diagnostic model of 3 states that include OK state, intermittent state and faulty state is presented. With the features based on the reflection coefficients of an alarm rate ( AR ) model extracted from small vibration samples, these models are trained to diagnose intermittent faults. The experimental results show that this method can diagnose multiple intermittent faults accurately with small training samples and BIT false alarms are reduced.