This research extends ongoing efforts to develop methods for reinforcing damaged main gas pipelines to prevent catastrophic failure.This study establishes the use of scaled-down experimental models for assessing the d...This research extends ongoing efforts to develop methods for reinforcing damaged main gas pipelines to prevent catastrophic failure.This study establishes the use of scaled-down experimental models for assessing the dynamic strength of damaged pipeline sections reinforced with wire wrapping or composite sleeves.A generalized dynamic model is introduced for numerical simulation to evaluate the effectiveness of reinforcement techniques.The model incorporates the elastoplastic behavior of pipe and wire materials,the influence of temperature on mechanical properties,the contact interaction between the pipe and the reinforcement components(including pretensioning),and local material failure under transient internal pressure.Based on these parameters,a finite element model was developed using ANSYS 19.2 to enable parametric studies.The accuracy of the proposed model was verified by comparing the simulation results with the experimental findings.Pipeline section samples containing non-penetrating longitudinal crackswere subjected to comparative analyses and transient pressure until critical failure.The unreinforced and steel wire-wrapped sections were investigated.The results confirm the feasibility of applying the computational model to study the dynamic strength of reinforced damaged pipe sections.Furthermore,pipelines with longitudinal cracks reinforced using circular composite overlays with orthotropic mechanical properties were examined,and recommendations are provided for selecting the geometric parameters of such overlays.展开更多
The optimal operation of water distribution networks under local pipe failures, such as water main breaks, was proposed. Based on a hydraulic analysis and a simulation of water distribution networks, a macroscopic mod...The optimal operation of water distribution networks under local pipe failures, such as water main breaks, was proposed. Based on a hydraulic analysis and a simulation of water distribution networks, a macroscopic model for a network under a local pipe failure was established by the statistical regression. After the operation objectives under a local pipe failure were determined, the optimal operation model was developed and solved by the genetic algorithm. The program was developed and examined by a city distribution network. The optimal operation alternative shows that the electricity cost is saved approximately 11%, the income of the water corporation is increased approximately 5%, and the pressure in the water distribution network is distributed evenly to ensure the network safe operation. Therefore, the proposed method for optimal operation under local pipe failure is feasible and cost-effective.展开更多
The latticed dunes in the Tengger Desert are widely distributed,and the sand-blocking fence placed here are highly susceptible to local failure due to complex wind-sand activities,posing a serious threat to the safe o...The latticed dunes in the Tengger Desert are widely distributed,and the sand-blocking fence placed here are highly susceptible to local failure due to complex wind-sand activities,posing a serious threat to the safe operation of the highway.To explore the local failure mechanism of sand-blocking fence in the latticed dune area,the local failure of sand-blocking fence in the latticed dune areas along the Wuhai-Maqin Highway in China was observed.Taking the first main ridge of the latticed dune as the placement location,the structure of the wind-sand flow field of sand-blocking fence placed at top,the bottom and the middle of windward slope was analyzed by Computational Fluid Dynamics(CFD).The results show that when placed at top of the first main ridge,the wind speed near the sand-blocking fence is the highest,up to 15.23 m/s.Therefore,the wind load strength on the sand barrier is correspondingly larger,up to 232.61 N∙m-2.As the strength of material continues to decrease,the nylon net is prone to breakage.The roots of the angle steel posts are susceptible to hollowing by vortex action,which can cause sand-blocking fence to fall over in strong wind conditions.When placed at the bottom of windward slope,wind speed drop near sand-blocking fence is greatest,with the decrease of 12.48-14.32 m/s compared to the original wind speed.This is highly likely to lead to large-scale deposition of sand particles and burial of the sand-blocking fence.When placed in the middle of windward slope,sand-blocking fence is subjected to less wind load strength(168.61N∙m-2)and sand particles are mostly deposited at the bottom of windward slope,with only a small amount of sand accumulating at the root of sand-blocking fence.Based on field observations and numerical modelling results,when the sand-blocking fence is placed in latticed dune area,it should be placed in the middle of the windward slope of the first main ridge as a matter of priority.Besides the sand-blocking fence should be placed at the top of the first main ridge,and sand fixing measures should be added.展开更多
The 2014 magnitude 6.5 Ludian earthquake caused a death toll of 617, many landslides and tens of thousands of collapsed buildings. A field investigation to evaluate the damage to buildings was carried out immediately ...The 2014 magnitude 6.5 Ludian earthquake caused a death toll of 617, many landslides and tens of thousands of collapsed buildings. A field investigation to evaluate the damage to buildings was carried out immediately after the occurrence of the earthquake. Severely damaged aseismic buildings, which were basically observed in the downtown of Longtoushan Town, were carefully examined one by one with the aim to improve design codes. This paper summarizes the damage observed to the investigated aseismic buildings in both the structural and local levels. A common failure mode was observed that most of the aseismic buildings, such as RC frame structures and confined masonry structures, were similarly destroyed by severe damage or complete collapse of the first story. The related strong ground motion, which was recorded at the nearby station, had a short duration of less than 20 s but a very large PGA up to 1.0 g. The RC frames based on the new design codes still failed to achieve the design target for "strong column, weak beam". Typical local failure details, which were related to the interaction between RC columns and infill walls and between constructional columns and masonry walls, are summarized with preliminary analyses.展开更多
Soils with strain-softening behavior — manifesting as a reduction of strength with increasing plastic strain — are commonly found in the natural environment. For slopes in these soils,a progressive failure mechanism...Soils with strain-softening behavior — manifesting as a reduction of strength with increasing plastic strain — are commonly found in the natural environment. For slopes in these soils,a progressive failure mechanism can occur due to a reduction of strength with increasing strain. Finite element method based numerical approaches have been widely performed for simulating such failure mechanism,owning to their ability for tracing the formation and development of the localized shear strain. However,the reliability of the currently used approaches are often affected by poor convergence or significant mesh-dependency,and their applicability is limited by the use of complicated soil models. This paper aims to overcome these limitations by developing a finite element approach using a local arc-length controlled iterative algorithm as the solution strategy. In the proposed finite element approach,the soils are simulated with an elastoplastic constitutive model in conjunction with the Mohr-Coulomb yield function. The strain-softening behavior is represented by a piece-wise linearrelationship between the Mohr-Coulomb strength parameters and the deviatoric plastic strain. To assess the reliability of the proposed finite element approach,comparisons of the numerical solutions obtained by different finite element methods and meshes with various qualities are presented. Moreover,a landslide triggered by excavation in a real expressway construction project is analyzed by the presented finite element approach to demonstrate its applicability for practical engineering problems.展开更多
Objective: To investigate the safety and effectiveness of three-dimensional conformal radiation therapy (3-D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: From April 1998 to March 2000, 34 patien...Objective: To investigate the safety and effectiveness of three-dimensional conformal radiation therapy (3-D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: From April 1998 to March 2000, 34 patients who had undergone previous external beam radiation therapy were retreated with 3-D CRT for locally recurrent NPC (33 poorly differentiated squamous cell carcinomas, 1 adenoma). The patients were re-staged according to Huaqing staging system with the following distribution: T1N0M0 in 5 cases, T2N0M0 in 11 cases, T3N0M0 in 12 cases, T4N0M0 in 6 cases. The maximal dimension of the gross tumor volume (GTV) ranged from 1.0 cm to 5.0 cm (median: 2.9 cm). CT simulation and 3-D planning were used to ensure full and conformal coverage of the planning target volume (PTV) by treated volume, while minimizing the absorbed dose of the adjacent normal tissue. 5–7 static conformal coplanar or noncoplanar portals were delivered for each fraction irradiation. The total dose delivered ranged from 65–70 Gy, with 2.5 Gy per fractionation, one fractionation per day, 5 days a week. Median follow-up time from 3-D CRT was 25 months (range: 12–36 months). Results: Over the follow-up period, local recurrence was observed in 3 patients, regional failure in 3, distant metastasis in 3, and six patients died; 88.2% (30/34) of the patient maintained local control, 82.4% (28/34) survived, and 76.5% (26/34) survived with no evidence of tumor. Acute complications were minor and few. The overall incidence of late complication was 20.6% (7/34), and severe complication was 14.7% (5/34), after re-irradiation with 3-D CRT. Conclusion: 3-D CRT is safety and effectiveness for most of the patients with locally recurrent NPC. Our preliminary results indicate a high local control rate and a low complication rate. The long-term curative effect and sequelae await further study.展开更多
基金funded by the Science Committee of the Ministry of Science and Higher Education of the Republic of Kazakhstan(Grant No.AP19680589).
文摘This research extends ongoing efforts to develop methods for reinforcing damaged main gas pipelines to prevent catastrophic failure.This study establishes the use of scaled-down experimental models for assessing the dynamic strength of damaged pipeline sections reinforced with wire wrapping or composite sleeves.A generalized dynamic model is introduced for numerical simulation to evaluate the effectiveness of reinforcement techniques.The model incorporates the elastoplastic behavior of pipe and wire materials,the influence of temperature on mechanical properties,the contact interaction between the pipe and the reinforcement components(including pretensioning),and local material failure under transient internal pressure.Based on these parameters,a finite element model was developed using ANSYS 19.2 to enable parametric studies.The accuracy of the proposed model was verified by comparing the simulation results with the experimental findings.Pipeline section samples containing non-penetrating longitudinal crackswere subjected to comparative analyses and transient pressure until critical failure.The unreinforced and steel wire-wrapped sections were investigated.The results confirm the feasibility of applying the computational model to study the dynamic strength of reinforced damaged pipe sections.Furthermore,pipelines with longitudinal cracks reinforced using circular composite overlays with orthotropic mechanical properties were examined,and recommendations are provided for selecting the geometric parameters of such overlays.
基金Project(50278062) supported by the National Natural Science Foundation of ChinaProject(003611611)supported by the Natural Science Foundation of Tianjin, China
文摘The optimal operation of water distribution networks under local pipe failures, such as water main breaks, was proposed. Based on a hydraulic analysis and a simulation of water distribution networks, a macroscopic model for a network under a local pipe failure was established by the statistical regression. After the operation objectives under a local pipe failure were determined, the optimal operation model was developed and solved by the genetic algorithm. The program was developed and examined by a city distribution network. The optimal operation alternative shows that the electricity cost is saved approximately 11%, the income of the water corporation is increased approximately 5%, and the pressure in the water distribution network is distributed evenly to ensure the network safe operation. Therefore, the proposed method for optimal operation under local pipe failure is feasible and cost-effective.
文摘The latticed dunes in the Tengger Desert are widely distributed,and the sand-blocking fence placed here are highly susceptible to local failure due to complex wind-sand activities,posing a serious threat to the safe operation of the highway.To explore the local failure mechanism of sand-blocking fence in the latticed dune area,the local failure of sand-blocking fence in the latticed dune areas along the Wuhai-Maqin Highway in China was observed.Taking the first main ridge of the latticed dune as the placement location,the structure of the wind-sand flow field of sand-blocking fence placed at top,the bottom and the middle of windward slope was analyzed by Computational Fluid Dynamics(CFD).The results show that when placed at top of the first main ridge,the wind speed near the sand-blocking fence is the highest,up to 15.23 m/s.Therefore,the wind load strength on the sand barrier is correspondingly larger,up to 232.61 N∙m-2.As the strength of material continues to decrease,the nylon net is prone to breakage.The roots of the angle steel posts are susceptible to hollowing by vortex action,which can cause sand-blocking fence to fall over in strong wind conditions.When placed at the bottom of windward slope,wind speed drop near sand-blocking fence is greatest,with the decrease of 12.48-14.32 m/s compared to the original wind speed.This is highly likely to lead to large-scale deposition of sand particles and burial of the sand-blocking fence.When placed in the middle of windward slope,sand-blocking fence is subjected to less wind load strength(168.61N∙m-2)and sand particles are mostly deposited at the bottom of windward slope,with only a small amount of sand accumulating at the root of sand-blocking fence.Based on field observations and numerical modelling results,when the sand-blocking fence is placed in latticed dune area,it should be placed in the middle of the windward slope of the first main ridge as a matter of priority.Besides the sand-blocking fence should be placed at the top of the first main ridge,and sand fixing measures should be added.
基金Funding of IEM under Grant No.2014B04National Natural Science Foundation under Grant Nos.51108433 and 51308511China Postdoctoral Science Foundation under Grant No.2013M531083
文摘The 2014 magnitude 6.5 Ludian earthquake caused a death toll of 617, many landslides and tens of thousands of collapsed buildings. A field investigation to evaluate the damage to buildings was carried out immediately after the occurrence of the earthquake. Severely damaged aseismic buildings, which were basically observed in the downtown of Longtoushan Town, were carefully examined one by one with the aim to improve design codes. This paper summarizes the damage observed to the investigated aseismic buildings in both the structural and local levels. A common failure mode was observed that most of the aseismic buildings, such as RC frame structures and confined masonry structures, were similarly destroyed by severe damage or complete collapse of the first story. The related strong ground motion, which was recorded at the nearby station, had a short duration of less than 20 s but a very large PGA up to 1.0 g. The RC frames based on the new design codes still failed to achieve the design target for "strong column, weak beam". Typical local failure details, which were related to the interaction between RC columns and infill walls and between constructional columns and masonry walls, are summarized with preliminary analyses.
基金funded by the Chinese National Basic Research Program (2010CB731503)
文摘Soils with strain-softening behavior — manifesting as a reduction of strength with increasing plastic strain — are commonly found in the natural environment. For slopes in these soils,a progressive failure mechanism can occur due to a reduction of strength with increasing strain. Finite element method based numerical approaches have been widely performed for simulating such failure mechanism,owning to their ability for tracing the formation and development of the localized shear strain. However,the reliability of the currently used approaches are often affected by poor convergence or significant mesh-dependency,and their applicability is limited by the use of complicated soil models. This paper aims to overcome these limitations by developing a finite element approach using a local arc-length controlled iterative algorithm as the solution strategy. In the proposed finite element approach,the soils are simulated with an elastoplastic constitutive model in conjunction with the Mohr-Coulomb yield function. The strain-softening behavior is represented by a piece-wise linearrelationship between the Mohr-Coulomb strength parameters and the deviatoric plastic strain. To assess the reliability of the proposed finite element approach,comparisons of the numerical solutions obtained by different finite element methods and meshes with various qualities are presented. Moreover,a landslide triggered by excavation in a real expressway construction project is analyzed by the presented finite element approach to demonstrate its applicability for practical engineering problems.
文摘Objective: To investigate the safety and effectiveness of three-dimensional conformal radiation therapy (3-D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: From April 1998 to March 2000, 34 patients who had undergone previous external beam radiation therapy were retreated with 3-D CRT for locally recurrent NPC (33 poorly differentiated squamous cell carcinomas, 1 adenoma). The patients were re-staged according to Huaqing staging system with the following distribution: T1N0M0 in 5 cases, T2N0M0 in 11 cases, T3N0M0 in 12 cases, T4N0M0 in 6 cases. The maximal dimension of the gross tumor volume (GTV) ranged from 1.0 cm to 5.0 cm (median: 2.9 cm). CT simulation and 3-D planning were used to ensure full and conformal coverage of the planning target volume (PTV) by treated volume, while minimizing the absorbed dose of the adjacent normal tissue. 5–7 static conformal coplanar or noncoplanar portals were delivered for each fraction irradiation. The total dose delivered ranged from 65–70 Gy, with 2.5 Gy per fractionation, one fractionation per day, 5 days a week. Median follow-up time from 3-D CRT was 25 months (range: 12–36 months). Results: Over the follow-up period, local recurrence was observed in 3 patients, regional failure in 3, distant metastasis in 3, and six patients died; 88.2% (30/34) of the patient maintained local control, 82.4% (28/34) survived, and 76.5% (26/34) survived with no evidence of tumor. Acute complications were minor and few. The overall incidence of late complication was 20.6% (7/34), and severe complication was 14.7% (5/34), after re-irradiation with 3-D CRT. Conclusion: 3-D CRT is safety and effectiveness for most of the patients with locally recurrent NPC. Our preliminary results indicate a high local control rate and a low complication rate. The long-term curative effect and sequelae await further study.