期刊文献+
共找到7,902篇文章
< 1 2 250 >
每页显示 20 50 100
Seismic performance of RC square columns strengthened with self-compacting concrete-filled steel tubes
1
作者 Zhang Zhaoqiang Cao Yang +2 位作者 Sa Yanru Mu Huiyu Li Xiaowei 《Earthquake Engineering and Engineering Vibration》 2025年第3期763-779,共17页
The behavior of reinforced concrete(RC)square columns strengthened with self-compacting concrete(SCC)-filled steel tubes under cyclic loading was experimentally investigated.Tests were carried out on eleven reinforced... The behavior of reinforced concrete(RC)square columns strengthened with self-compacting concrete(SCC)-filled steel tubes under cyclic loading was experimentally investigated.Tests were carried out on eleven reinforced columns and one unreinforced column.The parameters studied for the strengthened columns included axial compression ratio,reinforcement rate,defect rate,strength of SCC,and the section form of a reinforced steel tube.The results show that the steel tube SCC reinforcement method can effectively strengthen RC columns,exert the restraint effect of steel tube,and delay the development of internal concrete cracks.The method can also significantly improve the bearing capacity of RC columns.Regarding ductility,the improvement of the reinforced column is obvious,the deformation resistance of the specimen is enhanced,and the degradation of stiffness and strength is relatively slow,indicating that it has good seismic performance. 展开更多
关键词 steel tube strengthening self-compacting concrete RC column seismic performance
在线阅读 下载PDF
Calibration and Reliability Analysis of Eccentric Compressive Concrete Column with High Strength Rebars
2
作者 Baojun Qin Hong Jiang +1 位作者 Wei Zhang Xiang Liu 《Structural Durability & Health Monitoring》 2025年第5期1203-1220,共18页
The utilization of high-strength steel bars(HSSB)within concrete structures demonstrates significant advantages in material conservation and mechanical performance enhancement.Nevertheless,existing design codes exhibi... The utilization of high-strength steel bars(HSSB)within concrete structures demonstrates significant advantages in material conservation and mechanical performance enhancement.Nevertheless,existing design codes exhibit limitations in addressing the distinct statistical characteristics of HSSB,particularly regarding strength design parameters.For instance,GB50010-2010 fails to specify design strength values for reinforcement exceeding 600 MPa,creating technical barriers for advancing HSSB implementation.This study systematically investigates the reliability of eccentric compression concrete columns reinforced with 600 MPa-grade HSSB through high-order moment method analysis.Material partial factors were calibrated against target reliability indices prescribed by GB50068-2018,incorporating critical variables including live-to-dead load ratios,design methodologies,and service conditions.The findings show that the value of k significantly affects the calibration of material partial factors,impacting the reliability of bearing capacity.Considering various k values and target reliability indices,it is recommended that the material partialfactorbe setat1.15,implyingthatthedesignstrengthfor600MPahigh-strengthsteelbars shouldbe considered as 522 MPa.For safety levels I and II,load adjustment factors of 1.1 and 0.9,respectively,may be applied. 展开更多
关键词 Reliability high-strength steel rebar concrete column material partial factor high-order moment method failure probability
在线阅读 下载PDF
A novel control method of automatically formed roadway by roof cutting and confined concrete column in extremely close-distance coal seam
3
作者 XUE Hao-jie WANG Qi +4 位作者 ZHANG Chong HE Man-chao ZHANG Bo-wen ZHANG Shu WANG Ye-tai 《Journal of Central South University》 2025年第10期3911-3926,共16页
Under the influence of the upper coal pillars and dynamic pressure of coal mining,the roadway of the lower coal seam is prone to large deformation failure.In this paper,a novel control method and key technologies of a... Under the influence of the upper coal pillars and dynamic pressure of coal mining,the roadway of the lower coal seam is prone to large deformation failure.In this paper,a novel control method and key technologies of automatically formed roadway(AFR)by roof cutting and confined concrete column in extremely close-distance coal seam are proposed.Furthermore,a numerical model is established to analyze the structure characteristics of overlying roof strata.Based on numerical results,the roof structure model of“voussoir beam of upper layer+short cantilever beam of lower layer”of this method is proposed.What’s more,the calculation equation of the roof bending moment and evaluation indexes is established,and the influence of different factors on roof stability control of AFR is studied.Finally,a field test is conducted to verify the effectiveness of this novel method.Field results were as follows:1)The maximum and average support stress of working face obviously decreased;2)The confined concrete column can provide high-strength support in dynamic influence zone;3)The maximum deformation of AFR safety requirement can be met.This study can provide effective guidance for the application of this method in extremely close-distance coal seam. 展开更多
关键词 extremely close-distance coal seam automatically formed roadway(AFR) confined concrete column numerical simulation roof structure model field test
在线阅读 下载PDF
Finite Element Analysis of the Influence of End Grouting Defects in Grouted Sleeve on the Structural Performance of Precast Reinforced Concrete Columns
4
作者 Shuoting Xiao Nikita Igorevich Fomin +1 位作者 Kirill Anatolyevich Khvostunkov Chong Liu 《Computer Modeling in Engineering & Sciences》 2025年第12期2821-2847,共27页
Precast concrete structures have gained popularity due to their advantages.However,the seismic performance of their connection joints remains an area of ongoing research and improvement.Grouted Sleeve Connection(GSC)o... Precast concrete structures have gained popularity due to their advantages.However,the seismic performance of their connection joints remains an area of ongoing research and improvement.Grouted Sleeve Connection(GSC)offers a solution for connecting reinforcements in precast components,but their vulnerability to internal defects,such as construction errors and material variability,can significantly impact performance.This article presents a finite element analysis(FEA)to evaluate the impact of internal grouting defects in GSC on the structural performance of precast reinforced concrete columns.Four finite elementmodels representing GSC with varying degrees of defects were used to investigate the effects on mechanical properties,including bearing capacity,stress-deformation behavior,and stiffness degradation.The study highlights the significant impact of internal grouting defects on the mechanical performance of GSC,with findings indicating a decrease in stiffness,increased plastic deformation,and reduced energy dissipation as the proportion of internal defects rises.The analysis reveals that the internal defects in GSC act as stress concentration points,leading to early crack formation and accelerated damage under cyclic loading.By improving construction quality and reducing the prevalence of grouting defects,the adverse effects on the performance of GSC can be mitigated.Compared to defect-free specimens,those with defects of 30%exhibited a 31.23%reduction in horizontal bearing capacity,highlighting the importance of minimizing defects in practical engineering applications. 展开更多
关键词 Precast concrete structures column grouted sleeve connections(GSC) seismic performance internal defects finite element analysis(FEA) mechanical properties
在线阅读 下载PDF
Experimental study on concrete columns hybrid reinforced by steel and FRP bars under seismic loading 被引量:1
5
作者 孙泽阳 吴刚 +1 位作者 王燕华 吴智深 《Journal of Southeast University(English Edition)》 EI CAS 2016年第4期439-444,共6页
In order to study the dynamic behavior of hybrid reinforced concrete columns, shaking table tests of three concrete columns with equal initial stiffness were conducted.The longitudinal reinforcements include an ordina... In order to study the dynamic behavior of hybrid reinforced concrete columns, shaking table tests of three concrete columns with equal initial stiffness were conducted.The longitudinal reinforcements include an ordinary steel bar,a steel-fiber reinforced polymer(FRP) composite bar(SFCB), and hybrid reinforcement(steel bar and FRP bar, CH). Test results show that the peak ground acceleration(PGA) responses of different columns are similar to each other. For an ordinary reinforced concrete(RC) column, the plastic strain of the steel bar develops rapidly after the PGA of the input ground motion reaches 100 cm / s^2, and the corresponding residual strain develops dramatically. For a SFCB column, even after the peak strain reaches 0. 015, the residual strain is below 5 × 10^- 4. For the hybrid column C-H,the residual strain of the FRP bar is similar to that of the SFCB column. In general, concrete columns with hybrid steel and FRP bar reinforcement can achieve smaller residual deformation, and the SFCB reinforced columns can be constructed in extreme environments, such as offshore bridges, due to good anti-corrosion performance. 展开更多
关键词 concrete column shaking table test hybrid reinforcement peak ground acceleration strain distribution
在线阅读 下载PDF
Seismic strengthening of reinforced concrete columns damaged by rebar corrosion using combined CFRP and steel jacket 被引量:2
6
作者 李金波 贡金鑫 《Journal of Southeast University(English Edition)》 EI CAS 2009年第4期506-512,共7页
In order to study the effectiveness of combined carbon fiber-reinforced polymer (CFRP) sheets and steel jacket in strengthening the seismic performance of corrosion-damaged reinforced concrete (RC) columns, twelve... In order to study the effectiveness of combined carbon fiber-reinforced polymer (CFRP) sheets and steel jacket in strengthening the seismic performance of corrosion-damaged reinforced concrete (RC) columns, twelve reinforced concrete columns are tested under combined lateral cyclic displacement excursions and constant axial load. The variables studied in this program include effects of corrosion degree of the rebars, level of axial load, the amount of CFRP sheets and steel jacket. The results indicate that the combined CFRP and steel jacket retrofitting technique is effective in improving load-carrying, ductility and energy absorption capacity of the columns. Compared with the corrosion-damaged RC column, the lateral load and the ductility factor of many strengthened columns increase more than 90% and 100%, respectively. The formulae for the calculation of the yielding load, the maximum lateral load and the displacement ductility factor of the strengthened columns under combined constant axial load and cyclically increasing lateral loading are developed. The test results are also compared with the results obtained from the proposed formulae. A good agreement between calculated values and experimental results is observed. 展开更多
关键词 reinforced concrete column seismic performance CORROSION retrofitting steel jacket fiber-reinforced polymer (FRP) DUCTILITY
在线阅读 下载PDF
Strength of circular concrete columns under concentric compression
7
作者 赵玲 李爱群 《Journal of Southeast University(English Edition)》 EI CAS 2003年第1期74-78,共5页
An experimental study, in which six columns were loaded concentrically toinvestigate the behavior of reinforced normal strength and high strength circular columns underconcentric compression, is described. The concret... An experimental study, in which six columns were loaded concentrically toinvestigate the behavior of reinforced normal strength and high strength circular columns underconcentric compression, is described. The concrete strengths of the columns were 30 MPa and 60 MPa.The primary variables considered were the concrete strength and the amount of transversereinforcement. Test results indicate that smaller hoop spacing provides higher column capacity andgreater strength enhancement in a confined concrete core of columns. For the same lateralconfinement, high strength concrete columns develop lower strength enhancement than normal strengthconcrete columns. Both the strength enhancement ratio (f'_(cc) /f'_(co)) and the column capacityratio (P_(test)/P_o) were observed to show linear increase variations with rho_s f_(yt)/f'_c incircular columns. 展开更多
关键词 columnS high strength concrete hoop spacing concentric loading
在线阅读 下载PDF
Cyclic performance and simplified pushover analyses of precast segmental concrete bridge columns with circular section 被引量:14
8
作者 Bu Zhanyu Guo Jian +2 位作者 Zheng Rongyue Song Jianwei George C.Lee 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第2期297-312,共16页
In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed ... In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed configuration and appropriate design procedure to ensure a comparable performance with monolithic construction has impeded this structural system from being widely used in areas of high seismicity. In this study, precast segmental bridge column cyclic loading tests were conducted to investigate the performance of unbonded post-tensioned segmental bridge columns. One monolithic and two precast segmental columns were tested. The preeast segmental column exhibited minor damage and small residual displacement after the maximum 7% cyclic drift; energy dissipation (ED) can be enhanced byadding ED bars. The experimental results were modeled by a simplified pushover method (SPOM), as well as a fiber model (FIBM) finite element method. Forty-five cases of columns with different aspect ratios, axial load ratios and ED bar ratios were analyzed with the SPOM and FIBM, respectively. Using these parametric results, a simplified design method was suggested by regressive analysis. Satisfactory correlation was found between the experimental results and the simplified design method for preeast segmental columns with different design parameters. 展开更多
关键词 precast concrete segmental column simplified pushover fiber model
在线阅读 下载PDF
Dynamic performance of angle-steel concrete columns under low cyclic loading-I:Experimental study 被引量:21
9
作者 郑文忠 计 静 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2008年第1期67-75,共9页
This paper describes low cyclic loading testing of nine angle-steel concrete column (ASCC) specimens. In the tests, the influence of the shear-span ratio, axial compression ratio and shear steel plate ratio on the h... This paper describes low cyclic loading testing of nine angle-steel concrete column (ASCC) specimens. In the tests, the influence of the shear-span ratio, axial compression ratio and shear steel plate ratio on the hysteretic behavior, energy dissipation, strength degradation, stiffness degradation, skeleton curve and ductility of the ASCCs is studied. Based on the test results, some conclusions are presented. The P-A and sectional M -φ hysteretic models for the ASCCs are presented in a companion paper (Zheng and Ji, 2008). 展开更多
关键词 cyclic loading test DUCTILITY hysteretic model angle-steel concrete column shear-span ratio steel platestirrup steel jacketing seismic retrofitting
在线阅读 下载PDF
Failure mode classification of reinforced concrete column using Fisher method 被引量:12
10
作者 戚永乐 韩小雷 季静 《Journal of Central South University》 SCIE EI CAS 2013年第10期2863-2869,共7页
In order to apply the performance-based seismic design, an engineer must first find out whether the column is expected to fail in shear before or after flexural yielding. According to column failure characteristics an... In order to apply the performance-based seismic design, an engineer must first find out whether the column is expected to fail in shear before or after flexural yielding. According to column failure characteristics and failure mode of reinforced concrete column, the UW-PEER structure performance database was discussed and analyzed. In order to investigate the relevance of failure mode and factors such as longitudinal reinforcement ratio, transverse reinforcement ratio, hoop spacing to depth ratio, aspect ratio, shearing resistance demand to shear capacity ratio and axial load ratio, Fisher's discriminant analysis(FDA) of the above factors was carried out. A discriminant function was developed to identify column failure mode. Results show that three factors, i.e., Vp /Vn, hoop spacing to depth ratio and aspect ratio have important influence on the failure mode. The failure mode has less to do with longitudinal reinforcement ratio, transverse reinforcement ratio and axial load ratio. Through using these three factors and the model proposed, over 85.6% of the original grouped cases were correctly classified. The value of coefficient of Vp /Vn is the largest, which means that discriminant equation is most sensitive to the shearing resistance demand to shear capacity ratio. 展开更多
关键词 Fisher’s DISCRIMINANT analysis(FDA) concrete column FAILURE mode identification performance-based SEISMIC design
在线阅读 下载PDF
Dynamic performance of angle-steel concrete columns under low cyclic loading-II:parametric study 被引量:16
11
作者 Zheng Wenzhong Ji Jing 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2008年第2期137-146,共10页
Tests of nine angle-steel concrete column (ASCC) specimens under low cyclic loading are described in a companion paper (Zheng and Ji, 2008). In this paper, the skeleton curves from the numerical simulation are pre... Tests of nine angle-steel concrete column (ASCC) specimens under low cyclic loading are described in a companion paper (Zheng and Ji, 2008). In this paper, the skeleton curves from the numerical simulation are presented, and show good agreement with the test results. Furthermore, parametric studies are conducted to explore the influence of factors such as the axial compression ratio, shear steel plate ratio, steel ratio, prismatic concrete compression strength, yield strength of angle steel and shear span ratio, etc., on the monotonic load-displacement curves of the ASCCs. Based on a statistical analysis of the calculated results, hysteretic models for load-displacement and moment-curvature are proposed, which agree well with the test results. Finally, some suggestions concerning the conformation of ASCCs are proposed, which could be useful in engineering practice. 展开更多
关键词 low cyclic loading angle-steel concrete column shear-span ratio steel plate stirrup hysteretic model
在线阅读 下载PDF
Fragility curves of concrete bridges retrofitted by column jacketing 被引量:6
12
作者 MasanobuShinozuka Sang-HoonKim +1 位作者 Shigeru Kushiyama Jin-Hak Yi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2002年第2期195-205,共11页
The Northridge earthquake inflicted various levels of damage upon a large number of Caltrans' bridges not retrofitted by column jacketing.In this respect,this study represents results of fragility curve developmen... The Northridge earthquake inflicted various levels of damage upon a large number of Caltrans' bridges not retrofitted by column jacketing.In this respect,this study represents results of fragility curve development for two (2) sample bridges typical in southern California,strengthened for seismic retrofit by means of steel jacketing of bridge columns.Monte Carlo simulation is performed to study nonlinear dynamic responses of the bridges before and after column retrofit.Fragility curves in this study are represented by lognormal distribution functions with two parameters and developed as a function of PGA.The sixty (60) ground acceleration time histories for the Los Angeles area developed for the Federal Emergency Management Agency (FEMA) SAC (SEAOC-ATC CUREe) steel project are used for the dynamic analysis of the bridges. The improvement in the fragility with steel jacketing is quantified by comparing fragility curves of the bridge before and after column retrofit.In this first attempt to formulate the problem of fragility enhancement,the quantification is made by comparing the median values of the fragility curves before and after the retrofit.Under the hypothesis that this quantification also applies to empirical fragility curves developed on the basis of Northridge earthquake damage,the enhanced version of the empirical curves is developed for the ensuing analysis to determine the enhancement of transportation network performance due to the retrofit. 展开更多
关键词 fragility curves concrete bridges RETROFIT column jacketing nonlinear dynanlic ANALYSIS DUCTILITY
在线阅读 下载PDF
Damage assessment for seismic response of recycled concrete filled steel tube columns 被引量:5
13
作者 Huang Yijie Xiao Jianzhuang Shen Luming 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第3期607-616,共10页
A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the eff... A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the effect of repeated cyclic loading into account. Available test results were collected and utilized to calibrate the parameters of the proposed model. A seismic test for six RCFST columns was also performed to validate the proposed damage assessment model. The main test parameters were the recycled coarse aggregate (RCA) replacement percentage and the bond-slip property. The test results indicated that the seismic performance of the RCFST member depends on the RCA contents and their damage index increases as the RCA replacement percentage increases. It is also indicated that the damage degree of RCFST changes with the variation of the RCA replacement percentage. Finally, comparisons between the RCA contents, lateral deformation ratio and damage degree were implemented. It is suggested that an improvement procedure should be implemented in order to compensate for the performance difference between the RCFST and normal concrete filled steel tubes (CFST). 展开更多
关键词 recycled aggregate concrete (RAC) recycled concrete filled steel tube (RCFST) column seismicperformance damage assessment model (DAM)
在线阅读 下载PDF
Seismic Performance of High-Strength Short Concrete Column with High-Strength Stirrups Constraints 被引量:4
14
作者 Hongyan Ding Yuan Liu +1 位作者 Chao Han Yaohua Guo 《Transactions of Tianjin University》 EI CAS 2017年第4期360-369,共10页
The seismic performance of four short concrete columns was investigated under low cycle and repeated loads, including the failure characteristics, hysteretic behavior, rigidity degeneracy and steel-bar stress. The inf... The seismic performance of four short concrete columns was investigated under low cycle and repeated loads, including the failure characteristics, hysteretic behavior, rigidity degeneracy and steel-bar stress. The influences of reinforcement strength, stirrup ratio and shear span ratio were also compared. Test results reveal that the restriction effect of stirrups can improve the peak stress, so the bearing capacity of specimen can be improved; for the high-strength short concrete column with high-strength stirrups, it was more reasonable to use ultimate displacement angle to reflect the ductility of the specimen, and the yield strength of high-strength stirrups should be devalued when calculating the stirrup characteristic value; the seismic performance of short column would be improved with the increase of volume–stirrup ratio and shear span ratio; the high-strength stirrups and high-strength longitudinal reinforcements did not yield when the load acting on the specimen reached the peak value, which brought adequate safety stock to these short columns. © 2017, Tianjin University and Springer-Verlag Berlin Heidelberg. 展开更多
关键词 columns (structural) concrete construction concreteS HYSTERESIS Reinforced concrete Reinforcement Seismic waves SEISMOLOGY Shear flow
在线阅读 下载PDF
Earthquake simulation test of circular reinforced concrete bridge column under multidirectional seismic excitation 被引量:5
15
作者 Junichi Sakai Shigeki Unjoh 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2006年第1期103-110,共8页
Structures behave multi-directionally when subjected to earthquake excitation. Thus, it is essential to evaluate the effect of multidirectional loading on the dynamic response and seismic performance of reinforced con... Structures behave multi-directionally when subjected to earthquake excitation. Thus, it is essential to evaluate the effect of multidirectional loading on the dynamic response and seismic performance of reinforced concrete bridge columns in order to develop more advanced and reliable design procedures. To investigate such effects, a 1/4 scaled circular reinforced concrete bridge column specimen was tested under two horizontal and one vertical components of a strong motion that has long duration with several strong pulses. Damage progress of reinforced concrete columns subjected to strong excitation was evaluated from the test. The test results demonstrate that the lateral force response in the principal directions become smaller than computed flexural capacity due to the bilateral flexural loading effects, and that the lateral response is not significantly affected by the fluctuation of the axial force because the horizontal response and axial force barely reached the maximum simultaneously due to difference of the predominant natural periods between the vertical and the horizontal directions. Accuracy of fiber analyses is discussed using the test results. 展开更多
关键词 multidirectional seismic excitation reinforced concrete bridge columns shake table test nonlinear dynamic analyses fiber analysis
在线阅读 下载PDF
Experimental study on the seismic behavior of high strength concrete fi lled double-tube columns 被引量:14
16
作者 Qian Jiaru Li Ningbo +1 位作者 Ji Xiaodong Zhao Zuozhou 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第1期47-57,共11页
To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column sp... To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column specimens were conducted.The test variables included the width-to-thickness ratio(β1) and the area ratio(β2) of the square steel tube,the wall thickness of the circular steel tube,and the axial force(or the axial force ratio) applied to the CFDT columns.The test results indicate that for CFDT columns with a square steel tube with β1 of 50.1 and 24.5,local buckling of the specimen was found at a drift ratio of 1/150 and 1/50,respectively.The lateral force-displacement hysteretic loops of all specimens were plump and stable.Reducing the width-to-thickness ratio of the square steel tube,increasing its area ratio,or increasing the wall thickness of the internal circular steel tube,led to an increased fl exural strength and deformation capacity of the specimens.Increasing the design value of the axial force ratio from 0.8 to 1.0 may increase the fl exural strength of the specimens,while it may also decrease the ultimate deformation capacity of the specimen with β1 of 50.1. 展开更多
关键词 high strength concrete fi lled double-tube(CFDT)column seismic behavior area ratio of the square steel tube width-to-thickness ratio of the square steel tube axial force ratio quasi-static test
在线阅读 下载PDF
Effects of Length and Location of Steel Corrosion on the Behavior and Load Capacity of Reinforced Concrete Columns 被引量:4
17
作者 王小惠 刘西拉 邓宝如 《Journal of Shanghai Jiaotong university(Science)》 EI 2012年第4期391-400,共10页
The effects of length and location of the steel corrosion on the structural behavior and load capacity of reinforced concrete (RC) columns have been investigated. Results of the accelerated corrosion process and eccen... The effects of length and location of the steel corrosion on the structural behavior and load capacity of reinforced concrete (RC) columns have been investigated. Results of the accelerated corrosion process and eccentric load test are presented in detail. Effects of the location of the partial length, the corrosion level within partial length and the asymmetrical deterioration of the concrete section on the mechanical behavior and load capacity of corroded RC columns are discussed. It is found that the mechanical behavior and load carrying capacity of corroded RC columns are simultaneously affected by the above mentioned factors. For the corroded RC columns with large eccentricity, a higher corrosion level in the tensile corroded length and a greater asymmetrical deterioration of the concrete section can result in less ductile behavior and larger load reduction of the column; while for the corroded RC columns with small eccentricity, the less ductile behavior and the larger load reduction of the column may result from the higher corrosion level in the compressive corroded length and the greater asymmetrical deterioration of the concrete 展开更多
关键词 reinforced concrete (RC) column CORROSION partial length mechanical behavior load capacity
原文传递
Experimental study on the seismic response of braced reinforced concrete frame with irregular columns 被引量:6
18
作者 Xiao Jianzhuang Li Jie Chen Jun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第4期487-494,共8页
A 15-storey K-braced reinforced concrete model frame with irregular columns, i.e., T-shaped, L-shaped, as well as +-shaped columns, was constructed and tested on the six-degree-of-freedom shaking table at the State Ke... A 15-storey K-braced reinforced concrete model frame with irregular columns, i.e., T-shaped, L-shaped, as well as +-shaped columns, was constructed and tested on the six-degree-of-freedom shaking table at the State Key Laboratory for Disaster Reduction in Civil Engineering in Tongji, China. Two types of earthquake records, El-Centro wave (south-north direction) and Shanghai artificial wave (SHAW) with various peak accelerations and principal-secondary sequences, were input and experimentally studied. Based on the shaking table tests and theoretical analysis, several observations can be made. The failure sequence of the model structure is brace→beam→column→joints, so that the design philosophy for several lines of defense has been achieved. Earthquake waves with different spectrums not only influence the magnitude and distribution of the earthquake force and the storey shear force, but also obviously affect the magnitude of the displacement response. The aftershock seismic response of previously damaged reinforced concrete braced frames with irregular columns possesses the equivalent elastic performance characteristic. Generally speaking, from the aspects of failure features and drift ratio, this type of reinforced concrete structure provides adequate earthquake resistance and can be promoted for use in China. 展开更多
关键词 seismic response reinforced concrete braced frame irregular columns
在线阅读 下载PDF
Compressive Strength Estimation for the Fiber-Reinforced Polymer (FRP)-Confined Concrete Columns with Different Shapes Using Artificial Neural Networks 被引量:3
19
作者 曹玉贵 李小青 胡隽 《Journal of Donghua University(English Edition)》 EI CAS 2015年第3期395-400,共6页
An evaluation of existing strength of concrete columns confined with fiber-reinforced polymer( FRP) was presented with extensive collection of experimental data. According to the evaluation results, artificial neural ... An evaluation of existing strength of concrete columns confined with fiber-reinforced polymer( FRP) was presented with extensive collection of experimental data. According to the evaluation results, artificial neural networks( ANNs) model to predict the ultimate strength of FRP confined column with different shapes was proposed. The models had seven inputs including the column length,the tensile strength of the FRP in the hoop direction,the total thickness of FRP,the diameter of the concrete specimen,the elastic modulus of FRP,the corner radius and the concrete compressive strength. The compressive strength of the confined concrete was the output data. The results reveal that the proposed models have good prediction and generalization capacity with acceptable errors. 展开更多
关键词 compressive strength concrete column artificial neural networks(ANN) fiber-reinforced polymer(FRP)
在线阅读 下载PDF
Seismic behavior of large-scale FRP–recycled aggregate concrete–steel columns with shear connectors 被引量:2
20
作者 Zeng Lan Li Lijuan +1 位作者 Yang Xianqian Liu Feng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2019年第4期823-844,共22页
The application of fi ber-reinforced polymer (FRP) composites for the development of high-performance composite structural systems has received signifi cant recent research attention. A composite of FRP–recycled aggr... The application of fi ber-reinforced polymer (FRP) composites for the development of high-performance composite structural systems has received signifi cant recent research attention. A composite of FRP–recycled aggregate concrete (RAC)–steel column (FRSC), consisting of an outer FRP tube, an inner steel tube and annular RAC fi lled between two tubes, is proposed herein to facilitate green disposal of demolished concrete and to improve the ductility of concrete columns for earthquake resistance. To better understand the seismic behavior of FRSCs, quasi-static tests of large-scale basalt FRSCs with shear connectors were conducted. The infl uence of the recycled coarse aggregate (RCA) replacement percentage, shear connectors and axial loading method on the lateral load and deformation capacity, energy dissipation and cumulative damage were analyzed to evaluate the seismic behavior of FRSCs. The test results show that FRSCs have good seismic behavior, which was evidenced by high lateral loads, excellent ductility and energy dissipation capacity, indicating RAC is applicable in FRSCs. Shear connectors can signifi cantly postpone the steel buckling and increase the lateral loads of FRSCs, but weaken the deformation capacity and energy dissipation performance. 展开更多
关键词 recycled AGGREGATE concrete (RAC) fi ber-reinforced polymer (FRP) FRP–RAC–steel column (FRSC) shear connector seismic behavior
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部