President Xi Jinping’s message at China’s annual“two sessions”underpins the role of scientific and technological innovation and education in promoting national development.IN this year’s“two sessions,”the annua...President Xi Jinping’s message at China’s annual“two sessions”underpins the role of scientific and technological innovation and education in promoting national development.IN this year’s“two sessions,”the annual meetings of China’s top legislature and the top political advisory body.展开更多
Facial expression datasets commonly exhibit imbalances between various categories or between difficult and simple samples.This imbalance introduces bias into feature extraction within facial expression recognition(FER...Facial expression datasets commonly exhibit imbalances between various categories or between difficult and simple samples.This imbalance introduces bias into feature extraction within facial expression recognition(FER)models,which hinders the algorithm’s comprehension of emotional states and reduces the overall recognition accuracy.A novel FER model is introduced to address these issues.It integrates rebalancing mechanisms to regulate attention consistency and focus,offering enhanced efficacy.Our approach proposes the following improvements:(i)rebalancing weights are used to enhance the consistency between the heatmaps of an original face sample and its horizontally flipped counterpart;(ii)coefficient factors are incorporated into the standard cross entropy loss function,and rebalancing weights are incorporated to fine-tune the loss adjustment.Experimental results indicate that the FER model outperforms the current leading algorithm,MEK,achieving 0.69%and 2.01%increases in overall and average recognition accuracies,respectively,on the RAF-DB dataset.The model exhibits accuracy improvements of 0.49%and 1.01%in the AffectNet dataset and 0.83%and 1.23%in the FERPlus dataset,respectively.These outcomes validate the superiority and stability of the proposed FER model.展开更多
Drawing upon self-determination theory,this study examines the effects of vicarious abusive supervision on third-party’s self-efficacy and task performance within organizational contexts.Data were collected via surve...Drawing upon self-determination theory,this study examines the effects of vicarious abusive supervision on third-party’s self-efficacy and task performance within organizational contexts.Data were collected via surveys from 337 employees across diverse organizations.The results indicate that vicarious abusive supervision significantly undermines both self-efficacy and task performance among employees who are indirectly exposed to such behavior but not directly targeted.Furthermore,self-efficacy serves as a mediator between vicarious abusive supervision and task performance;however,this mediating effect is attenuated for employees with a high promotion focus.These findings provide valuable theoretical and practical insights,particularly in the domain of organizational behavior,by emphasizing the critical role of promotion focus in mitigating the negative effects of vicarious abusive supervision.This research contributes to the organizational behavior literature by shifting the focus from the traditional supervisor-subordinate dynamic to a third-party perspective,thereby enriching our understanding of how vicarious abusive supervision impacts employees within organizational settings.The study underscores the importance of self-efficacy and promotion focus as key factors in unethical leadership contexts.展开更多
Efficient elastic wave focusing is crucial in materials and physical engineering.Elastic coding metasurfaces,which are innovative planar artificial structures,show great potential for use in the field of wave focusing...Efficient elastic wave focusing is crucial in materials and physical engineering.Elastic coding metasurfaces,which are innovative planar artificial structures,show great potential for use in the field of wave focusing.However,elastic coding lenses(ECLs)still suffer from low focusing performance,thickness comparable to wavelength,and frequency sensitivity.Here,we consider both the structural and material properties of the coding unit,thus realizing further compression of the thickness of the ECL.We chose the simplest ECL,which consists of only two encoding units.The coding unit 0 is a straight structure constructed using a carbon fiber reinforced composite material,and the coding unit 1 is a zigzag structure constructed using an aluminum material,and the thickness of the ECL constructed using them is only 1/8 of the wavelength.Based on the theoretical design,the arrangement of coding units is further optimized using genetic algorithms,which significantly improves the focusing performance of the lens at different focus and frequencies.This study provides a more effective way to control vibration and noise in advanced structures.展开更多
Transcranial focused ultrasound(tFUS)is an emerging modality with strong potential for non-invasively treating brain disorders.However,the inhomogeneity and complex structure of the skull induce substantial phase aber...Transcranial focused ultrasound(tFUS)is an emerging modality with strong potential for non-invasively treating brain disorders.However,the inhomogeneity and complex structure of the skull induce substantial phase aberrations and pressure attenuation;these can distort and shift the acoustic focus,thus hindering the efficiency of tFUS therapy.To achieve effective treatments,phased array transducers combined with aberration correction algorithms are commonly implemented.The present report aims to provide a comprehensive review of the current methods used for tFUS phase aberration correction.We first searched the PubMed and Web of Science databases for studies on phase aberration correction algorithms,identifying 54 articles for review.Relevant information,including the principles of algorithms and refocusing performances,were then extracted from the selected articles.The phase correction algorithms involved two main steps:acoustic field estimation and transmitted pulse adjustment.Our review identified key benchmarks for evaluating the effectiveness of these algorithms,each of which was used in at least three studies.These benchmarks included pressure and intensity,positioning error,focal region size,peak sidelobe ratio,and computational efficiency.Algorithm performances varied under different benchmarks,thus highlighting the importance of application-specific algorithm selection for achieving optimal tFUS therapy outcomes.The present review provides a thorough overview and comparison of various phase correction algorithms,and may offer valuable guidance to tFUS researchers when selecting appropriate phase correction algorithms for specific applications.展开更多
This paper explores the phenomenon of fluid resonance occurring within a narrow gap between a vessel and a vertical wharf, taking ships berthing in front of a gravity wharf as the research background. Using the open-s...This paper explores the phenomenon of fluid resonance occurring within a narrow gap between a vessel and a vertical wharf, taking ships berthing in front of a gravity wharf as the research background. Using the open-source software Open FOAM~?, a two-dimensional viscous-flow numerical wave flume was developed to simulate the fluid resonant motions induced by transient focused wave groups with different spectral peak periods and wave amplitudes. The results indicate that for all the incident focused wave amplitudes considered, the amplitudes of the free surface elevation in the gap, horizontal wave force and moment all exhibit a bimodal variation trend with increasing spectral peak period. The peak values of the above amplitude-period curve appear near the resonant period of the first and second harmonic components of the free surface elevation. However, the variation in the vertical wave force versus the spectral peak period presents different patterns. In addition, the first-to fourth-order harmonic components in the wave surface and forces are further examined via the four-phase combination method. The results show that the first-to secondorder harmonic components play a dominant role in the overall amplitude.展开更多
Adjustable or programmable metamaterials offer versatile functions,while the complex multi-dimensional regulation increases workload,and hinders their applications in practical scenarios.To address these challenges,we...Adjustable or programmable metamaterials offer versatile functions,while the complex multi-dimensional regulation increases workload,and hinders their applications in practical scenarios.To address these challenges,we present a mechanically programmable acoustic metamaterial for real-time focal tuning via one-dimensional phase-gradient modulation in this paper.The device integrates a phase gradient structure with concave cavity channels and an x-shaped telescopic mechanical framework,enabling dynamic adjustment of inter-unit spacing(1 mm-3 mm)through a microcontroller-driven motor.By modulating the spacing between adjacent channels,the phase gradient is precisely controlled,allowing continuous focal shift from 50 mm to 300 mm along the x-axis at 7500 Hz.Broadband focusing is also discussed in the range6800 Hz-8100 Hz,with transmission coefficients exceeding 0.5,ensuring high efficiency and robust performance.Experimental results align closely with simulations,validating the design's effectiveness and adaptability.Unlike conventional programmable metamaterials requiring multi-dimensional parameter optimization,this approach simplifies real-time control through single-axis mechanical adjustment,significantly reducing operational complexity.Due to the advantages of broadband focusing,simple control mode,real-time monitoring,and so on,the device may have extensive applications in the fields of acoustic imaging,nondestructive testing,ultrasound medical treatment,etc.展开更多
AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract s...AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions.展开更多
Techniques for manipulating nanodroplets lie at the core of numerous miniaturized systems in chemical and biological research endeavors.In this study,we introduce a versatile methodology for calculating the acoustic v...Techniques for manipulating nanodroplets lie at the core of numerous miniaturized systems in chemical and biological research endeavors.In this study,we introduce a versatile methodology for calculating the acoustic vortex field,integrating hybrid wave equation principles with ray acoustics.This approach demonstrates remarkable consistency between simulated results and experimental observations.Importantly,both theoretical analysis and experimental validation confirm that particles whose diameters match the wavelength(Mie particles)can be effectively trapped within a focused acoustic vortex field,rotating in circular trajectories centered at the vortex center.This research significantly expands the scope of acoustic vortex manipulation for larger particles and introduces a novel implementation strategy with potential applications in targeted drug delivery for clinical adjuvant therapy.展开更多
Measurement precision of laser displacement sensor is subject to various factors,among which laser jitter and target tilt will directly lead to the position movement and shape variation of the laser spot,resulting in ...Measurement precision of laser displacement sensor is subject to various factors,among which laser jitter and target tilt will directly lead to the position movement and shape variation of the laser spot,resulting in displacement measurement errors,so that researchers have to do a lot of research on the spot centering algorithm to weaken the above effects,which can treat the symptoms but not the root cause.Starting from the source of the problem,this paper proposes a double focus double peak solution,which uses a reflector to change the direction of the optical path,so that the imaging spots of the designed two optical paths focus on the same CMOS,forming a double peak structure.When laser jitter or target tilt occurs,the center of the two laser spots is shifted,but they move in the same direction,while their relative position remains unchanged.Therefore,the displacement can be characterized by the relative position of the two laser spots,so that laser jitter and target tilt are suppressed from the source.However,the two spots imaged on CMOS form a non-Gaussian distributed double peak structure,so the conventional laser spot centering algorithms are no longer applicable.To this end,a double peak adaptive threshold waveform extraction method combined with grayscale gravity method is proposed for spot centering algorithm,which combines the suppression of laser jitter and target tilt from the source and the improvement of spot positioning precision which represents the displacement measurement precision,and is experimentally verified.展开更多
Three-dimensional(3D)nanoprinting via two-photon polymerization offers unparalleled design flexibility and precision,thereby enabling rapid prototyping of advanced micro-optical elements and systems that have found im...Three-dimensional(3D)nanoprinting via two-photon polymerization offers unparalleled design flexibility and precision,thereby enabling rapid prototyping of advanced micro-optical elements and systems that have found important applications in endomicroscopy and biomedical imaging.The potential of this versatile tool for monolithic manufacturing of dynamic micro-opto-electro-mechanical systems(MOEMSs),however,has not yet been sufficiently explored.This work introduces a 3D-nanoprinted lens actuator with a large optical aperture,optimized for remote focusing in miniaturized imaging systems.The device integrates orthoplanar linear motion springs,a self-aligned sintered micro-magnet,and a monolithic lens,actuated by dual microcoils for uniaxial motion.The use of 3D nanoprinting allows complete design freedom for the integrated optical lens,whereas the monolithic fabrication ensures inherent alignment of the lens with the mechanical elements.With a lens diameter of 1.4 mm and a compact footprint of 5.74 mm,it achieves high mechanical robustness at resonant frequencies exceeding 300 Hz while still providing a large displacement range of 200μm(±100μm).A comprehensive analysis of optical and mechanical performance,including the effects of coil temperature and polymer viscoelasticity,demonstrates its advantages over conventional micro-electro-mechanical system actuators,showcasing its potential for next-generation imaging applications.展开更多
It has long been noticed that focus is able to influence the truth-conditions of coun-terfactual conditionals.Namely,stressing different parts of a counterfactual leads to distinct interpretations.However,existing the...It has long been noticed that focus is able to influence the truth-conditions of coun-terfactual conditionals.Namely,stressing different parts of a counterfactual leads to distinct interpretations.However,existing theories,such as those by von Finte1 and Rooth,fail to ad-equately account for this phenomenon.In this paper,I exposit the drawbacks of these theories and then propose a novel account,ie.the Good Question-Answer(GQA)view.The GQA account posits that focus triggers question-answer pairs,and pragmatic pressures conceming the adequacy of such question answer pairs in contexts are able to affect the truth-conditions of counterfactuals.I also argue for the GQA account by appeal to its theoretical virtues.展开更多
Background:Platinum can cause chemotherapy-related cognitive impairment.Low-intensity focused ultrasound(LIFUS)is a promising noninvasive physical stimulation method with a unique advantage in neurological rehabilitat...Background:Platinum can cause chemotherapy-related cognitive impairment.Low-intensity focused ultrasound(LIFUS)is a promising noninvasive physical stimulation method with a unique advantage in neurological rehabilitation.We aimed to investigate whether LIFUS can alleviate cisplatin-induced cognitive impairment in rats and explore the related neuropatho-logical mechanisms.Methods:After confirming the target position for LIFUS treatment in 18 rats,64 rats were randomly divided into four groups:control,model,sham,and LIFUS groups.Before and after LIFUS treatment,detailed biological behavioral assessments and magnetic resonance imaging were performed.Finally,the rats were euthanized,and relevant histopathological and molecular biological experiments were conducted and analyzed.Results:In the Morris water maze,the model group showed fewer platform crossings(1.250.93 vs.5.691.58),a longer escape latency(41.6536.55 s vs.6.382.11 s),and a lower novel object recognition index(29.7711.83 vs.83.695.67)than the control group.LIFUS treatment improved these metrics,with more platform crossings(3.130.34),a higher recognition index(65.588.71),and a shorter escape latency(6.452.27 s).Longitudinal analysis of the LIFUS group further confirmed these improvements.Neuroimaging revealed significant differences in diffusion tensor imaging metrics of specific brain regions pre-and post-LIFUS.Moreover,neuropathology showed higher dendritic spine density,less myelin loss,fewer apoptotic cells,more synapses,and less mitochondrial autophagy after LIFUS treatment.The neuroimaging indicators were correlated with behavioral improvements,highlighting the potential of LIFUS for alleviating cognitive impairment(as demonstrated through imaging and analysis).Our investigation of the molecular biological mechanisms revealed distinct protein expression patterns in the hippocampus and its subregions.In the model group,glial fibrillary acidic protein(GFAP)and ionized calcium-binding adaptor molecule 1(IBA1)expression levels were elevated across the hippocampus,whereas neuronal nuclei(NeuN)expression was reduced.Subregional analysis revealed higher GFAP and IBA1 and lower NeuN,especially in the dentate gyrus subregion.Moreover,positive cell areas were larger in the cornu ammonis(CA)1,CA2,CA3,and dentate gyrus regions.In the CA2 and CA3,significant differences among the groups were observed in GFAP-positive cell counts and areas,and there were variations in NeuN expression.Conclusions:Our results suggest that LIFUS can reverse cisplatin-induced cognitive impairments.The neuroimaging findings were consistent with the behavioral and histological results and suggest a neuropathological basis that supports further research into the clinical applications of LIFUS.Furthermore,LIFUS appeared to enhance the plasticity of neuronal synapses in the rat hippocampus and reduce hippocampal inflammation.These findings highlight the clinical potential of LIFUS as an effective,noninvasive therapeutic strategy and monitoring tool for chemotherapy-induced cognitive deficits.展开更多
Focused ultrasound(FUS)therapy generates sufficient heat for medical interventions like tumor ablation by concentrating energy at the focal point.The complex viscoelastic properties of biological tissues pose challeng...Focused ultrasound(FUS)therapy generates sufficient heat for medical interventions like tumor ablation by concentrating energy at the focal point.The complex viscoelastic properties of biological tissues pose challenges in balancing focusing precision and penetration depth,impacting the safety of surrounding tissues and treatment efficacy.This study develops an acoustic-solid-thermal coupling computational model to elucidate the dynamic mechanical response and energy dissipation mechanisms of soft tissue during FUS thermal therapy using a hyper-viscoelastic constitutive model.Results indicate that the high compressibility and low shear resistance of biological tissues result in a unique shear dissipation mechanism.Energy dissipation efficiency per area is indirectly influenced by load frequency via its effect on the dynamic shear modulus and is directly proportional to load amplitude.Focusing precision,represented by the focal zone width,is inversely controlled by frequency via wavelength.A mathematical model for evaluating temperature rise efficiency is proposed,and an optimal frequency for efficient FUS thermal therapy in brain-like soft materials is identified.This research elucidates the link between viscoelastic tissue behavior and FUS treatment outcomes,offering insights for optimizing FUS applications in various medical fields.展开更多
This study utilizes a visualization nozzle and spray experimental platform to experimentally investigate the flow focusing/blurring nozzle.It is found that the working mode of the nozzle transitions from flow focusing...This study utilizes a visualization nozzle and spray experimental platform to experimentally investigate the flow focusing/blurring nozzle.It is found that the working mode of the nozzle transitions from flow focusing to flow transition and eventually to flow blurring as the gas flow rate increases or the tube hole distance decreases.Conversely,an increase in liquid flow rate only facilitates the transition from flow focusing to flow transition.Changes in the gas/liquid flow rate or tube hole distance influence the gas shear effect and the gas inertial impact effect inside the nozzle,which in turn alters the working mode.An increase in gas flow rate results in a shift of the droplet size distribution towards smaller particle sizes in the flow blurring mode,whereas an increase in liquid flow rate produces the opposite effect.Notably,the impact of the gas flow rate on these changes is more pronounced than that of the liquid flow rate.展开更多
Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance to...Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance tomography enables real-time monitoring of changes in cerebral blood perfusion within the ischemic brain,but investigating the feasibility of using this method to assess post-stroke rehabilitation in vivo remains critical.In this study,ischemic stroke was induced in rats through middle cerebral artery occlusion surgery.Transcranial focused ultrasound stimulation was used to treat the rat model of ischemia,and electrical impedance tomography was used to measure impedance during both the acute stage of ischemia and the rehabilitation stage following the stimulation.Electrical impedance tomography results indicated that cerebral impedance increased after the onset of ischemia and decreased following transcranial focused ultrasound stimulation.Furthermore,the stimulation promoted motor function recovery,reduced cerebral infarction volume in the rat model of ischemic stroke,and induced the expression of brain-derived neurotrophic factor in the ischemic brain.Our results also revealed a significant correlation between the impedance of the ischemic brain post-intervention and improvements in behavioral scores and infarct volume.This study shows that daily administration of transcranial focused ultrasound stimulation for 20 minutes to the ischemic hemisphere 24 hours after cerebral ischemia enhanced motor recovery in a rat model of ischemia.Additionally,our findings indicate that electrical impedance tomography can serve as a valuable tool for quantitatively evaluating rehabilitation after ischemic stroke in vivo.These findings suggest the feasibility of using impedance data collected via electrical impedance tomography to clinically assess the effects of rehabilitatory interventions for patients with ischemic stroke.展开更多
文摘President Xi Jinping’s message at China’s annual“two sessions”underpins the role of scientific and technological innovation and education in promoting national development.IN this year’s“two sessions,”the annual meetings of China’s top legislature and the top political advisory body.
基金support from the National Natural Science Foundation of China(Grant Number 62477023).
文摘Facial expression datasets commonly exhibit imbalances between various categories or between difficult and simple samples.This imbalance introduces bias into feature extraction within facial expression recognition(FER)models,which hinders the algorithm’s comprehension of emotional states and reduces the overall recognition accuracy.A novel FER model is introduced to address these issues.It integrates rebalancing mechanisms to regulate attention consistency and focus,offering enhanced efficacy.Our approach proposes the following improvements:(i)rebalancing weights are used to enhance the consistency between the heatmaps of an original face sample and its horizontally flipped counterpart;(ii)coefficient factors are incorporated into the standard cross entropy loss function,and rebalancing weights are incorporated to fine-tune the loss adjustment.Experimental results indicate that the FER model outperforms the current leading algorithm,MEK,achieving 0.69%and 2.01%increases in overall and average recognition accuracies,respectively,on the RAF-DB dataset.The model exhibits accuracy improvements of 0.49%and 1.01%in the AffectNet dataset and 0.83%and 1.23%in the FERPlus dataset,respectively.These outcomes validate the superiority and stability of the proposed FER model.
文摘Drawing upon self-determination theory,this study examines the effects of vicarious abusive supervision on third-party’s self-efficacy and task performance within organizational contexts.Data were collected via surveys from 337 employees across diverse organizations.The results indicate that vicarious abusive supervision significantly undermines both self-efficacy and task performance among employees who are indirectly exposed to such behavior but not directly targeted.Furthermore,self-efficacy serves as a mediator between vicarious abusive supervision and task performance;however,this mediating effect is attenuated for employees with a high promotion focus.These findings provide valuable theoretical and practical insights,particularly in the domain of organizational behavior,by emphasizing the critical role of promotion focus in mitigating the negative effects of vicarious abusive supervision.This research contributes to the organizational behavior literature by shifting the focus from the traditional supervisor-subordinate dynamic to a third-party perspective,thereby enriching our understanding of how vicarious abusive supervision impacts employees within organizational settings.The study underscores the importance of self-efficacy and promotion focus as key factors in unethical leadership contexts.
基金Project supported by the National Natural Science Foundation of China(Grant No.12404531)the Natural Science Foundation of the Higher Education Institutions of Jiangsu Province,China(Grant No.23KJB140011)。
文摘Efficient elastic wave focusing is crucial in materials and physical engineering.Elastic coding metasurfaces,which are innovative planar artificial structures,show great potential for use in the field of wave focusing.However,elastic coding lenses(ECLs)still suffer from low focusing performance,thickness comparable to wavelength,and frequency sensitivity.Here,we consider both the structural and material properties of the coding unit,thus realizing further compression of the thickness of the ECL.We chose the simplest ECL,which consists of only two encoding units.The coding unit 0 is a straight structure constructed using a carbon fiber reinforced composite material,and the coding unit 1 is a zigzag structure constructed using an aluminum material,and the thickness of the ECL constructed using them is only 1/8 of the wavelength.Based on the theoretical design,the arrangement of coding units is further optimized using genetic algorithms,which significantly improves the focusing performance of the lens at different focus and frequencies.This study provides a more effective way to control vibration and noise in advanced structures.
基金supported by Start-Up Grant From ShanghaiTech University,2021F0209-000-09Natural Science Foundation of Shanghai Municipality,23ZR1442000。
文摘Transcranial focused ultrasound(tFUS)is an emerging modality with strong potential for non-invasively treating brain disorders.However,the inhomogeneity and complex structure of the skull induce substantial phase aberrations and pressure attenuation;these can distort and shift the acoustic focus,thus hindering the efficiency of tFUS therapy.To achieve effective treatments,phased array transducers combined with aberration correction algorithms are commonly implemented.The present report aims to provide a comprehensive review of the current methods used for tFUS phase aberration correction.We first searched the PubMed and Web of Science databases for studies on phase aberration correction algorithms,identifying 54 articles for review.Relevant information,including the principles of algorithms and refocusing performances,were then extracted from the selected articles.The phase correction algorithms involved two main steps:acoustic field estimation and transmitted pulse adjustment.Our review identified key benchmarks for evaluating the effectiveness of these algorithms,each of which was used in at least three studies.These benchmarks included pressure and intensity,positioning error,focal region size,peak sidelobe ratio,and computational efficiency.Algorithm performances varied under different benchmarks,thus highlighting the importance of application-specific algorithm selection for achieving optimal tFUS therapy outcomes.The present review provides a thorough overview and comparison of various phase correction algorithms,and may offer valuable guidance to tFUS researchers when selecting appropriate phase correction algorithms for specific applications.
基金financially supported by the National Natural Science Foundation of China (Grant No. 52371277)the State Key Laboratory of Hydraulic Engineering Intelligent Construction and Operation (Tianjin University)(Grant No. HESS-2323)+2 种基金the Postgraduate Research&Practice Innovation Program of Jiangsu Province (Grant No. KYCX24_4071)the Guangdong Basic and Applied Basic Research Foundation (Grant No. 2023A1515010890)the Open foundation of Key Laboratory of Port.Waterway&Sedimentation Engineering (Grant No. Yk224001-1)。
文摘This paper explores the phenomenon of fluid resonance occurring within a narrow gap between a vessel and a vertical wharf, taking ships berthing in front of a gravity wharf as the research background. Using the open-source software Open FOAM~?, a two-dimensional viscous-flow numerical wave flume was developed to simulate the fluid resonant motions induced by transient focused wave groups with different spectral peak periods and wave amplitudes. The results indicate that for all the incident focused wave amplitudes considered, the amplitudes of the free surface elevation in the gap, horizontal wave force and moment all exhibit a bimodal variation trend with increasing spectral peak period. The peak values of the above amplitude-period curve appear near the resonant period of the first and second harmonic components of the free surface elevation. However, the variation in the vertical wave force versus the spectral peak period presents different patterns. In addition, the first-to fourth-order harmonic components in the wave surface and forces are further examined via the four-phase combination method. The results show that the first-to secondorder harmonic components play a dominant role in the overall amplitude.
基金supported by the National Natural Science Foundation of China(Grant No.12374416)。
文摘Adjustable or programmable metamaterials offer versatile functions,while the complex multi-dimensional regulation increases workload,and hinders their applications in practical scenarios.To address these challenges,we present a mechanically programmable acoustic metamaterial for real-time focal tuning via one-dimensional phase-gradient modulation in this paper.The device integrates a phase gradient structure with concave cavity channels and an x-shaped telescopic mechanical framework,enabling dynamic adjustment of inter-unit spacing(1 mm-3 mm)through a microcontroller-driven motor.By modulating the spacing between adjacent channels,the phase gradient is precisely controlled,allowing continuous focal shift from 50 mm to 300 mm along the x-axis at 7500 Hz.Broadband focusing is also discussed in the range6800 Hz-8100 Hz,with transmission coefficients exceeding 0.5,ensuring high efficiency and robust performance.Experimental results align closely with simulations,validating the design's effectiveness and adaptability.Unlike conventional programmable metamaterials requiring multi-dimensional parameter optimization,this approach simplifies real-time control through single-axis mechanical adjustment,significantly reducing operational complexity.Due to the advantages of broadband focusing,simple control mode,real-time monitoring,and so on,the device may have extensive applications in the fields of acoustic imaging,nondestructive testing,ultrasound medical treatment,etc.
文摘AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions.
基金Project supported by the National Key R&D Program of China(Grant No.2023YFE0201900)。
文摘Techniques for manipulating nanodroplets lie at the core of numerous miniaturized systems in chemical and biological research endeavors.In this study,we introduce a versatile methodology for calculating the acoustic vortex field,integrating hybrid wave equation principles with ray acoustics.This approach demonstrates remarkable consistency between simulated results and experimental observations.Importantly,both theoretical analysis and experimental validation confirm that particles whose diameters match the wavelength(Mie particles)can be effectively trapped within a focused acoustic vortex field,rotating in circular trajectories centered at the vortex center.This research significantly expands the scope of acoustic vortex manipulation for larger particles and introduces a novel implementation strategy with potential applications in targeted drug delivery for clinical adjuvant therapy.
基金the Biomedical Science and Technology Support Special Project of Shanghai Science and Technology Committee(No.20S31908300)。
文摘Measurement precision of laser displacement sensor is subject to various factors,among which laser jitter and target tilt will directly lead to the position movement and shape variation of the laser spot,resulting in displacement measurement errors,so that researchers have to do a lot of research on the spot centering algorithm to weaken the above effects,which can treat the symptoms but not the root cause.Starting from the source of the problem,this paper proposes a double focus double peak solution,which uses a reflector to change the direction of the optical path,so that the imaging spots of the designed two optical paths focus on the same CMOS,forming a double peak structure.When laser jitter or target tilt occurs,the center of the two laser spots is shifted,but they move in the same direction,while their relative position remains unchanged.Therefore,the displacement can be characterized by the relative position of the two laser spots,so that laser jitter and target tilt are suppressed from the source.However,the two spots imaged on CMOS form a non-Gaussian distributed double peak structure,so the conventional laser spot centering algorithms are no longer applicable.To this end,a double peak adaptive threshold waveform extraction method combined with grayscale gravity method is proposed for spot centering algorithm,which combines the suppression of laser jitter and target tilt from the source and the improvement of spot positioning precision which represents the displacement measurement precision,and is experimentally verified.
文摘Three-dimensional(3D)nanoprinting via two-photon polymerization offers unparalleled design flexibility and precision,thereby enabling rapid prototyping of advanced micro-optical elements and systems that have found important applications in endomicroscopy and biomedical imaging.The potential of this versatile tool for monolithic manufacturing of dynamic micro-opto-electro-mechanical systems(MOEMSs),however,has not yet been sufficiently explored.This work introduces a 3D-nanoprinted lens actuator with a large optical aperture,optimized for remote focusing in miniaturized imaging systems.The device integrates orthoplanar linear motion springs,a self-aligned sintered micro-magnet,and a monolithic lens,actuated by dual microcoils for uniaxial motion.The use of 3D nanoprinting allows complete design freedom for the integrated optical lens,whereas the monolithic fabrication ensures inherent alignment of the lens with the mechanical elements.With a lens diameter of 1.4 mm and a compact footprint of 5.74 mm,it achieves high mechanical robustness at resonant frequencies exceeding 300 Hz while still providing a large displacement range of 200μm(±100μm).A comprehensive analysis of optical and mechanical performance,including the effects of coil temperature and polymer viscoelasticity,demonstrates its advantages over conventional micro-electro-mechanical system actuators,showcasing its potential for next-generation imaging applications.
基金supported by the Major Program of National Social Science Foundation of China(No.23&ZD240)。
文摘It has long been noticed that focus is able to influence the truth-conditions of coun-terfactual conditionals.Namely,stressing different parts of a counterfactual leads to distinct interpretations.However,existing theories,such as those by von Finte1 and Rooth,fail to ad-equately account for this phenomenon.In this paper,I exposit the drawbacks of these theories and then propose a novel account,ie.the Good Question-Answer(GQA)view.The GQA account posits that focus triggers question-answer pairs,and pragmatic pressures conceming the adequacy of such question answer pairs in contexts are able to affect the truth-conditions of counterfactuals.I also argue for the GQA account by appeal to its theoretical virtues.
基金supported by the National Natural Science Foundation of China(82171908 and 82102015)the General Project of the Nanjing Medical Science and Technology Development Program(YKK21075)the Guangdong Basic and Applied Basic Research Foundation(No.2023A1515140030).
文摘Background:Platinum can cause chemotherapy-related cognitive impairment.Low-intensity focused ultrasound(LIFUS)is a promising noninvasive physical stimulation method with a unique advantage in neurological rehabilitation.We aimed to investigate whether LIFUS can alleviate cisplatin-induced cognitive impairment in rats and explore the related neuropatho-logical mechanisms.Methods:After confirming the target position for LIFUS treatment in 18 rats,64 rats were randomly divided into four groups:control,model,sham,and LIFUS groups.Before and after LIFUS treatment,detailed biological behavioral assessments and magnetic resonance imaging were performed.Finally,the rats were euthanized,and relevant histopathological and molecular biological experiments were conducted and analyzed.Results:In the Morris water maze,the model group showed fewer platform crossings(1.250.93 vs.5.691.58),a longer escape latency(41.6536.55 s vs.6.382.11 s),and a lower novel object recognition index(29.7711.83 vs.83.695.67)than the control group.LIFUS treatment improved these metrics,with more platform crossings(3.130.34),a higher recognition index(65.588.71),and a shorter escape latency(6.452.27 s).Longitudinal analysis of the LIFUS group further confirmed these improvements.Neuroimaging revealed significant differences in diffusion tensor imaging metrics of specific brain regions pre-and post-LIFUS.Moreover,neuropathology showed higher dendritic spine density,less myelin loss,fewer apoptotic cells,more synapses,and less mitochondrial autophagy after LIFUS treatment.The neuroimaging indicators were correlated with behavioral improvements,highlighting the potential of LIFUS for alleviating cognitive impairment(as demonstrated through imaging and analysis).Our investigation of the molecular biological mechanisms revealed distinct protein expression patterns in the hippocampus and its subregions.In the model group,glial fibrillary acidic protein(GFAP)and ionized calcium-binding adaptor molecule 1(IBA1)expression levels were elevated across the hippocampus,whereas neuronal nuclei(NeuN)expression was reduced.Subregional analysis revealed higher GFAP and IBA1 and lower NeuN,especially in the dentate gyrus subregion.Moreover,positive cell areas were larger in the cornu ammonis(CA)1,CA2,CA3,and dentate gyrus regions.In the CA2 and CA3,significant differences among the groups were observed in GFAP-positive cell counts and areas,and there were variations in NeuN expression.Conclusions:Our results suggest that LIFUS can reverse cisplatin-induced cognitive impairments.The neuroimaging findings were consistent with the behavioral and histological results and suggest a neuropathological basis that supports further research into the clinical applications of LIFUS.Furthermore,LIFUS appeared to enhance the plasticity of neuronal synapses in the rat hippocampus and reduce hippocampal inflammation.These findings highlight the clinical potential of LIFUS as an effective,noninvasive therapeutic strategy and monitoring tool for chemotherapy-induced cognitive deficits.
基金This work was supported by the National Natural Science Foundation of China(Grant Nos.11972205,11921002,11972210,and 12302096)the National Key Research Development Program of China(Grant No.2020-JCJQ-ZD-254).
文摘Focused ultrasound(FUS)therapy generates sufficient heat for medical interventions like tumor ablation by concentrating energy at the focal point.The complex viscoelastic properties of biological tissues pose challenges in balancing focusing precision and penetration depth,impacting the safety of surrounding tissues and treatment efficacy.This study develops an acoustic-solid-thermal coupling computational model to elucidate the dynamic mechanical response and energy dissipation mechanisms of soft tissue during FUS thermal therapy using a hyper-viscoelastic constitutive model.Results indicate that the high compressibility and low shear resistance of biological tissues result in a unique shear dissipation mechanism.Energy dissipation efficiency per area is indirectly influenced by load frequency via its effect on the dynamic shear modulus and is directly proportional to load amplitude.Focusing precision,represented by the focal zone width,is inversely controlled by frequency via wavelength.A mathematical model for evaluating temperature rise efficiency is proposed,and an optimal frequency for efficient FUS thermal therapy in brain-like soft materials is identified.This research elucidates the link between viscoelastic tissue behavior and FUS treatment outcomes,offering insights for optimizing FUS applications in various medical fields.
基金the National Natural Science Foundation of China(52276026).
文摘This study utilizes a visualization nozzle and spray experimental platform to experimentally investigate the flow focusing/blurring nozzle.It is found that the working mode of the nozzle transitions from flow focusing to flow transition and eventually to flow blurring as the gas flow rate increases or the tube hole distance decreases.Conversely,an increase in liquid flow rate only facilitates the transition from flow focusing to flow transition.Changes in the gas/liquid flow rate or tube hole distance influence the gas shear effect and the gas inertial impact effect inside the nozzle,which in turn alters the working mode.An increase in gas flow rate results in a shift of the droplet size distribution towards smaller particle sizes in the flow blurring mode,whereas an increase in liquid flow rate produces the opposite effect.Notably,the impact of the gas flow rate on these changes is more pronounced than that of the liquid flow rate.
基金supported by the Fundamental Research Funds for the Central Universities,Nos.G2021KY05107,G2021KY05101the National Natural Science Foundation of China,Nos.32071316,32211530049+1 种基金the Natural Science Foundation of Shaanxi Province,No.2022-JM482the Education and Teaching Reform Funds for the Central Universities,No.23GZ230102(all to LL and HH).
文摘Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance tomography enables real-time monitoring of changes in cerebral blood perfusion within the ischemic brain,but investigating the feasibility of using this method to assess post-stroke rehabilitation in vivo remains critical.In this study,ischemic stroke was induced in rats through middle cerebral artery occlusion surgery.Transcranial focused ultrasound stimulation was used to treat the rat model of ischemia,and electrical impedance tomography was used to measure impedance during both the acute stage of ischemia and the rehabilitation stage following the stimulation.Electrical impedance tomography results indicated that cerebral impedance increased after the onset of ischemia and decreased following transcranial focused ultrasound stimulation.Furthermore,the stimulation promoted motor function recovery,reduced cerebral infarction volume in the rat model of ischemic stroke,and induced the expression of brain-derived neurotrophic factor in the ischemic brain.Our results also revealed a significant correlation between the impedance of the ischemic brain post-intervention and improvements in behavioral scores and infarct volume.This study shows that daily administration of transcranial focused ultrasound stimulation for 20 minutes to the ischemic hemisphere 24 hours after cerebral ischemia enhanced motor recovery in a rat model of ischemia.Additionally,our findings indicate that electrical impedance tomography can serve as a valuable tool for quantitatively evaluating rehabilitation after ischemic stroke in vivo.These findings suggest the feasibility of using impedance data collected via electrical impedance tomography to clinically assess the effects of rehabilitatory interventions for patients with ischemic stroke.