期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Measurement of Electron Return Effect and Skin Dose Reduction by a Bolus in an Anthropomorphic Physical Phantom under a Magnetic Resonance Guided Linear Accelerator (MR-LINAC) System 被引量:1
1
作者 Eun Young Han Zhifei Wen +2 位作者 Hannah J. Lee Arnold dela Cruz Paulino Choonsik Lee 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第3期339-346,共8页
Background: Magnetic resonance image-guided radiation therapy (MR-IGRT) promises more precise and effective radiation treatments compared to conventional IGRT by using real-time on-board MR imaging. Under the influenc... Background: Magnetic resonance image-guided radiation therapy (MR-IGRT) promises more precise and effective radiation treatments compared to conventional IGRT by using real-time on-board MR imaging. Under the influence of a magnetic field, however, secondary electrons exiting a surface can be forced in a circular path and re-enter the medium, resulting in dose increase at a beam-exit surface, called the electron return effect (ERE). The purpose of the study is to compare the exit skin dose computed by Monte Carlo dose calculation with measurements using an adult anthropomorphic phantom and to measure the effect of skin dose reduction by adding 1 cm-thick bolus. Method: The plan was compared with measurements using an adult anthropomorphic phantom combined with radiochromic films and thermoluminescent dosimeters. We also measured the skin dose reduction by adding 1 cm-thick bolus on the frontal surface of the phantom. Results: We found that 1 cm-thick bolus reduced the skin dose by up to 20% both in measurements and calculations. The plan was found to overestimate the measured skin dose by about 10% and there was no significant difference in the bolus effect between the breast skin and the skin (without breast attachment) doses. Conclusion: In conclusion, we confirmed the ERE effect on the anthropomorphic phantom under the magnetic field and the exit skin dose reduction by adding a bolus. Skin dose measurements using anthropomorphic phantom may be helpful to evaluate more realistic skin dose and the bolus effect in the magnetic field. 展开更多
关键词 MR-Linac electron return effect Skin Dose
暂未订购
磁场下夹层结构的高能电子屏蔽性能
2
作者 陈托 汤晓斌 +2 位作者 陈飞达 倪敏轩 张云 《强激光与粒子束》 EI CAS CSCD 北大核心 2017年第12期137-142,共6页
针对空间高能电子环境可能造成的航天设备故障、宇航员辐照损伤等情况,基于电子束返回效应,提出了一种磁场下金属/真空夹层式高能电子屏蔽结构。采用Geant4软件,模拟空间高能电子连续能谱,研究磁场下夹层式结构的高能电子屏蔽性能。此外... 针对空间高能电子环境可能造成的航天设备故障、宇航员辐照损伤等情况,基于电子束返回效应,提出了一种磁场下金属/真空夹层式高能电子屏蔽结构。采用Geant4软件,模拟空间高能电子连续能谱,研究磁场下夹层式结构的高能电子屏蔽性能。此外,建立体素模型,计算射线在人体中的累积剂量,从而评估磁感应强度、屏蔽体材料对屏蔽性能的影响。结果表明:与传统被动屏蔽方式相比,夹层式结构具有电子屏蔽性能高、生成透射次级X射线少的特点;随着磁感应强度增加,体模中累积剂量下降,证明夹层结构的电子屏蔽性能不断提升;Ti/Ti材料组合的屏蔽方式具有更优越的高能电子屏蔽性能。该结构具备较好的高能电子屏蔽性能,将来有望对空间高能电子辐射环境进行有效防护。 展开更多
关键词 夹层结构 磁场 电子屏蔽 电子束返回效应 剂量评估
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部