期刊文献+
共找到859篇文章
< 1 2 43 >
每页显示 20 50 100
The ECT System for RAON'S Cavities
1
作者 Mijoung Joung Yoochul Jung Hyungjin Kim 《Journal of Mechanics Engineering and Automation》 2015年第1期53-57,共5页
The ECT (eddy current test) system is in use for Nb surface quality control in many laboratories. This system can inspect Nb surthce quickly using high resolution probe. The ECT system for RAON's cavity was made wi... The ECT (eddy current test) system is in use for Nb surface quality control in many laboratories. This system can inspect Nb surthce quickly using high resolution probe. The ECT system for RAON's cavity was made with these features: it has a 3-axis acting probe movenlent system, it can inspect a big size of Nb sheet, which is 1,200 mm × 365 mm and it contains the analysis program that can show the result as a 2D and 3D images as well as the relative figure of the surface level. The standard sample was made with various sizes of defects using the same Nb sheet that was used to make RISP (Rare Isotope Science Project) cavity. The ECT system conditioning was carried out to optimize the ECT operation on the frequency of which the range is from 300 KHZ to 2 MHz. The result of 900 KHZ showed the strongest signal. The conditioning experiment on other parameter will be carried out in the near future. 展开更多
关键词 SRF (superconducting radio frequency) cavity eddy current NON-DESTRUCTIVE NIOBIUM ect system
在线阅读 下载PDF
A high-resolution small animal SPECT system developed at Tsinghua 被引量:3
2
作者 DAI Tiantian MATianyu +4 位作者 LIU Hui CUI Junjian WEI Qingyang LIU Yaqiang WANG Shi 《Nuclear Science and Techniques》 SCIE CAS CSCD 2011年第6期344-348,共5页
An SPECT system dedicated to small animal imaging shall be of a millimeter spatial resolution or even better.This study was aimed at achieving 0.5-mm spatial resolution for a small animal SPECT system at low cost.It w... An SPECT system dedicated to small animal imaging shall be of a millimeter spatial resolution or even better.This study was aimed at achieving 0.5-mm spatial resolution for a small animal SPECT system at low cost.It was developed from a single-head clinical SPECT scanner,with a seven-pinhole collimator and a four-degree-offreedom motion control stage.Several key techniques were developed,including high-resolution image reconstruction algorithm,high accuracy geometrical calibration method,and optimized system matrix derivation scheme.The system matrix was derived from Monte-Carlo simulation and de-noised by fitting each point spread function to a two dimensional Gaussian function.Experiments of point source and ultra micro hot rod phantom were conducted.With a spatial resolution of 0.5-0.6 mm,this system provides a practical way for low-cost high-resolution animal imaging on a clinic SPECT system. 展开更多
关键词 高分辨率图像重建 ect系统 小动物 SP 清华大学 开发 空间分辨率 高斯函数拟合
在线阅读 下载PDF
曲妥珠单抗联合ECT化疗方案应用乳腺癌患者中对其血清肿瘤标志物的影响及治疗效果 被引量:1
3
作者 代广全 王显臣 刘剑峰 《中国医药指南》 2025年第7期63-66,共4页
目的 探讨乳腺癌患者应用曲妥珠单抗联合ECT化疗方案对血清肿瘤标志物的影响及疗效。方法 选取2020年4月至2024年4月在青岛大学附属威海市立第二医院治疗的60例乳腺癌患者作为研究对象,按随机数字表法分组。对照组30例,给予ECT[表柔比星... 目的 探讨乳腺癌患者应用曲妥珠单抗联合ECT化疗方案对血清肿瘤标志物的影响及疗效。方法 选取2020年4月至2024年4月在青岛大学附属威海市立第二医院治疗的60例乳腺癌患者作为研究对象,按随机数字表法分组。对照组30例,给予ECT[表柔比星(E)+环磷酰胺(C)+紫杉醇(T)]化疗方案治疗;观察组30例,采取曲妥珠单抗联合ECT靶向治疗。观察两组的血清肿瘤标志物指标、血清炎症因子、近期疗效及远期疗效、不良反应的具体变化。结果 观察组糖类抗原125、癌胚抗原、糖类抗原153水平均低于对照组(均P <0.05);观察组炎症因子指标水平均低于对照组(均P <0.05);缓解率及2年生存率更高,复发率低于对照组(P <0.05);两组不良反应发生率差异无统计学意义(P> 0.05)。结论 曲妥珠单抗联合ECT化疗方案可有效减轻肿瘤负荷,增强抗肿瘤免疫反应,抑制炎症反应,延长患者生存周期并提高生存质量,降低复发风险。 展开更多
关键词 乳腺癌 曲妥珠单抗 ect化疗方案 肿瘤标志物 远期疗效
暂未订购
基于PCNN图像融合的ECT多相流测量系统设计 被引量:1
4
作者 李利品 李垄 +2 位作者 盛哲 白耀文 胡跃鑫 《仪表技术与传感器》 CSCD 北大核心 2024年第4期48-52,58,共6页
针对ECT在多相流测量过程中存在的成像质量不高、精度低、稳定性差等问题,提出并实现了基于PCNN图像融合的ECT多相流测量系统。系统采用模块化设计,主要包括阵列电极传感器模块、电容采集电路模块、上位机成像软件模块。文中设计改进的... 针对ECT在多相流测量过程中存在的成像质量不高、精度低、稳定性差等问题,提出并实现了基于PCNN图像融合的ECT多相流测量系统。系统采用模块化设计,主要包括阵列电极传感器模块、电容采集电路模块、上位机成像软件模块。文中设计改进的网络模型,将Tikhonov和Landweber算法的成像结果作为输入进行双通道融合成像,改善了传统算法存在的伪影、模糊的现象。实验结果表明:应用尼龙棒模拟气固两相流对系统进行测试,系统对于微小电容的测量具有良好的稳定性和准确性,通过系统的成像结果可以准确地分辨管道内不同介质的位置,其中对于流型的预测成功率为100%,相含率的测量误差在1%以内。 展开更多
关键词 ect 多相流测量 图像融合 图像重建
在线阅读 下载PDF
miR-223-3p与ECT2表达在食管鳞状细胞癌组织中的相关性及与其预后的关系 被引量:1
5
作者 范俊利 雷彩鹏 +1 位作者 张卫国 赵安顺 《实用癌症杂志》 2024年第6期898-903,924,共7页
目的探讨miR-223-3p与ECT2表达在食管鳞状细胞癌中的相关性及与其预后的关系。方法纳入85例食管鳞状细胞癌的石蜡包埋食管鳞状细胞癌组织、相应的正常食管黏膜组织。实时荧光定量PCR检测miR-223-3p与ECT2 mRNA水平,Pearson相关系数分析m... 目的探讨miR-223-3p与ECT2表达在食管鳞状细胞癌中的相关性及与其预后的关系。方法纳入85例食管鳞状细胞癌的石蜡包埋食管鳞状细胞癌组织、相应的正常食管黏膜组织。实时荧光定量PCR检测miR-223-3p与ECT2 mRNA水平,Pearson相关系数分析miR-223-3p与ECT2 mRNA表达水平的相关性。Kaplan-Meier生存分析和Cox比例风险模型分析miR-223-3p、ECT2表达对食管鳞状细胞癌预后的影响。结果ECT2高表达食管鳞状细胞癌患者46例,ECT2低表达食管鳞状细胞癌患者39例。ECT2 mRNA表达水平食管鳞状细胞癌组织高于正常食管黏膜组织,miR-223-3p表达水平食管鳞状细胞癌组织低于正常食管黏膜组织。ECT2表达水平与肿瘤大小、分化程度、TNM分期、血管侵犯相关。miR-223-3p表达水平与肿瘤大小、分化程度、TNM分期、血管侵犯相关。此外,食管鳞状细胞癌中miR-223-3p与ECT2 mRNA表达存在相关性(ρ=-0.5223,P<0.0001),miR-223-3p与ECT2蛋白表达存在相关性(χ^(2)=21.56,P<0.0001)。Kaplan-Meier生存分析显示:TNM分期、淋巴结转移、神经侵犯、miR-223-3p表达水平、ECT2表达水平对食管鳞状细胞癌患者的总生存期有影响。Cox比例风险模型发现TNM分期、淋巴结转移、神经侵犯、miR-223-3p表达水平、ECT2表达水平对总生存期有影响。结论miR-223-3p与ECT2的表达水平在食管鳞状细胞癌中存在相关性。TNM分期、淋巴结转移、神经侵犯、miR-223-3p表达水平、ECT2表达水平可作为ESCC的独立预后因素。 展开更多
关键词 miR-223-3p ect2 食管鳞状细胞癌 相关性 预后
暂未订购
通过卷积神经网络分析ECT成像和临床检验数据评估糖尿病视网膜病变和糖尿病肾病之间的相关性 被引量:5
6
作者 唐娟 李庆华 +12 位作者 邓秀英 鲁婷 唐国强 林志武 刘兴德 吴小利 方其林 李盈 王潇 周燕 李彪 戴传强 李涛 《眼科新进展》 CAS 北大核心 2024年第2期127-132,共6页
目的从影像学和临床检验数据综合评估2型糖尿病患者(T2DM)中糖尿病肾病(DN)和糖尿病视网膜病变(DR)的相关性。方法选取2021年3月至2022年12月就诊于资阳市第一人民医院的T2DM患者600例,所有患者均行眼底照相和荧光素眼底血管造影检查,... 目的从影像学和临床检验数据综合评估2型糖尿病患者(T2DM)中糖尿病肾病(DN)和糖尿病视网膜病变(DR)的相关性。方法选取2021年3月至2022年12月就诊于资阳市第一人民医院的T2DM患者600例,所有患者均行眼底照相和荧光素眼底血管造影检查,收集患者年龄、性别、T2DM持续时间、心血管疾病、脑血管疾病、高血压、吸烟史、饮酒史、体重指数、收缩压和舒张压等临床数据。测量空腹血糖、甘油三酯、总胆固醇、高密度脂蛋白胆固醇、低密度脂蛋白胆固醇、糖化血红蛋白、24 h尿白蛋白、尿白蛋白/肌酐、血肌酐和血尿素氮水平。采用Logistic回归分析与DR相关的危险因素。根据眼底图片进行DR分期,采用卷积神经网络(CNN)算法作为图像分析方法,通过ECT成像技术和临床检验数据评估DR和DN之间的相关性。结果采用CNN算法进行分析,无明显DR、轻度非增生型DR(NPDR)、中度NPDR、重度NPDR和增生型DR(PDR)组患者的DR和DN病变面积率均高于采用传统算法(TCM)的结果。随着DR的加重,患者血肌酐、血尿素氮、24 h尿白蛋白和尿白蛋白/肌酐均逐渐升高,无明显DR、轻度NPDR、中度NPDR、重度NPDR和PDR组患者的DN发生率分别为1.67%、8.83%、16.16%、22.16%和30.83%。Logistic回归分析结果显示,T2DM持续时间、吸烟史、糖化血红蛋白、总胆固醇、甘油三酯、高密度脂蛋白胆固醇、低密度脂蛋白胆固醇、24 h尿白蛋白、血肌酐、血尿素氮、尿白蛋白/肌酐、肾小球滤过率是DR的独立危险因素。肾动态ECT成像分析结果表明,随着DR的加重,肾血流灌注逐渐减少,从而导致肾过滤功能下降。结论在T2DM患者中,CNN算法早期应用于DR和DN图像的分析,将有助于提高DR和DN病变面积诊断准确性,随着DR病变的加重,DN的严重程度逐渐增加。 展开更多
关键词 卷积神经网络 2型糖尿病 糖尿病视网膜病变 糖尿病肾病 ect成像技术
暂未订购
玉米ECT家族成员的全基因组分析及非生物胁迫下的响应表达 被引量:1
7
作者 徐可丽 周美君 +5 位作者 郭怡婷 吉虹菁 黄敏 李曼菲 杜何为 刘睿 《核农学报》 CAS CSCD 北大核心 2024年第6期1035-1047,共13页
ECT结构域蛋白家族作为一种重要的转录后调控因子,在调控m6A修饰中发挥重要功能,在植物正常生长发育和响应逆境胁迫时的基因表达调控中具有重要作用。为了研究ECT结构域蛋白家族在玉米(Zea mays L.)非生物胁迫下的生长发育与胁迫响应中... ECT结构域蛋白家族作为一种重要的转录后调控因子,在调控m6A修饰中发挥重要功能,在植物正常生长发育和响应逆境胁迫时的基因表达调控中具有重要作用。为了研究ECT结构域蛋白家族在玉米(Zea mays L.)非生物胁迫下的生长发育与胁迫响应中的功能,本研究采用生物信息学方法鉴定到玉米ECT家族成员22个,并分析其序列和结构特征、染色体分布、启动子顺式作用元件、GO富集、蛋白质互作网络和系统发育进化关系,通过实时荧光定量PCR(qRT-PCR)分析了玉米ZmECTs在冷胁迫以及不同激素处理下的表达模式。结果表明,玉米ECT家族成员分布在10条染色体上,编码的蛋白质所含氨基酸残基数目为119~748 aa,相对分子量(MW)范围为13412.17~81823.70 Da,等电点(pI)范围为5.43~8.82,大部分蛋白定位在细胞核。在ZmECT家族中共鉴定到10个motif。顺式作用元件分析结果表明,ZmECT家族成员启动子包含多个与胁迫、激素和生长发育相关的响应元件。GO富集分析结果显示,ZmECT家族成员可能参与mRNA的剪接和维持RNA稳定性。蛋白质互作网络预测,ZmECT6是该家族蛋白的核心成员。系统进化树显示,ZmECT家族成员分为4组。qRT-PCR结果显示,经不同激素处理后,ZmECT家族成员表现出复杂的响应模式,部分ZmECT家族成员响应冷胁迫。本研究结果为玉米ECT基因后续的生物学功能解析及分子机制研究提供了参考。 展开更多
关键词 玉米(Zea mays L.) ect家族 生物信息学 非生物胁迫 响应表达
在线阅读 下载PDF
Spectra of seismic force reduction factors of MDOF systems normalized by two characteristic periods 被引量:1
8
作者 Li Xiao Tong Genshu Zhang Lei 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第1期53-69,共17页
Seismic force reduction factor(SFRF) spectra of shear-type multi-degree-of-freedom(MDOF) structures are investigated. The modified Clough model, capable of considering the strength-degradation/hardening and stiffnessd... Seismic force reduction factor(SFRF) spectra of shear-type multi-degree-of-freedom(MDOF) structures are investigated. The modified Clough model, capable of considering the strength-degradation/hardening and stiffnessdegradation, is adopted. The SFRF mean spectra using 102 earthquake records on a typical site soil type(type C) are constructed with the period abscissa being divided into three period ranges to maintain the peak features at the two sitespecific characteristic periods. Based on a large number of results, it is found that the peak value of SFRF spectra may also exist for MDOF, induced by large high-mode contributions to elastic base shear, besides the mentioned two peak values. The variations of the stiffness ratio λk and the strength ratio λF of the top to bottom story are both considered. It is found that the SFRFs for λF ≤λk are smaller than those for λF > λk. A SFRF modification factor for MDOF systems is proposed with respect to SDOF. It is found that this factor is significantly affected by the story number and ductility. With a specific λF(= λk0.75), SFRF mean spectra are constructed and simple solutions are presented for MDOF systems. For frames satisfying the strong column/weak beam requirement, an approximate treatment in the MDOF shear-beam model is to assign a post-limit stiffness 15%-35% of the initial stiffness to the hysteretic curve. SFRF spectra for MDOF systems with 0.2 and 0.3 times the post-limit stiffness are remarkably larger than those without post-limit stiffness. Thus, the findings that frames with beam hinges have smaller ductility demand are explained through the large post-limit stiffness. 展开更多
关键词 seismic force reduction factor multi-degree of freedom modifi ed Clough model characteristic period highmode eff ect post-limit stiff ness analysis
在线阅读 下载PDF
曲妥珠单抗联合ECT化疗方案对晚期乳腺癌患者疗效、血清CA153、CEA及造血功能影响 被引量:5
9
作者 牛猛 董燕兵 +2 位作者 李孝涛 张俊生 张峰 《分子诊断与治疗杂志》 2024年第3期565-568,577,共5页
目的 探讨曲妥珠单抗联合表柔比星(E)+环磷酰胺(C)+紫杉醇(T)化疗方案对晚期乳腺癌患者疗效、血清癌抗原153(CA153)、癌胚抗原(CEA)及造血功能的影响。方法 选择安徽阜南县人民医院2019年10月至2022年10月收治的60例晚期乳腺癌患者,按... 目的 探讨曲妥珠单抗联合表柔比星(E)+环磷酰胺(C)+紫杉醇(T)化疗方案对晚期乳腺癌患者疗效、血清癌抗原153(CA153)、癌胚抗原(CEA)及造血功能的影响。方法 选择安徽阜南县人民医院2019年10月至2022年10月收治的60例晚期乳腺癌患者,按照随机数表法分为ECT组30例(接受表柔比星+环磷酰胺、多西他赛治疗)和联合组30例(ECT组基础上使用曲妥珠单抗),比较两组临床疗效、血清CA153、CEA、造血功能、不良反应。结果 联合组有效率高于ECT组(96.67%vs. 80.00%),差异有统计学意义(χ^(2)=4.043,P<0.05)。两组血清CA153、CEA均较治疗前降低,疗程结束时,联合组上述水平低于ECT组,差异有统计学意义(t=14.795、17.472,P<0.05)。两组血小板计数(PLT)、血红蛋白(Hb)、白细胞计数(WBC)均较治疗前降低,疗程结束时,两组上述指标及不良反应比较差异无统计学意义(t=1.052、1.751、1.676,P>0.05)。结论 相较于单一使用ECT化疗方案,ECT化疗方案联合曲妥珠单抗可以提高晚期乳腺癌患者临床疗效,降低血清CA153、CEA水平,且不会对患者造血功能造成影响。 展开更多
关键词 乳腺癌 晚期 曲妥珠单抗 ect化疗方案 癌抗原153 癌胚抗原
暂未订购
Boosted Electrocatalytic Glucose Oxidation Reaction on Noble-Metal-Free MoO_(3)-Decorated Carbon Nanotubes 被引量:1
10
作者 Yu-Long Men Ning Dou +3 位作者 Yiyi Zhao Yan Huang Lei Zhang Peng Liu 《Transactions of Tianjin University》 EI CAS 2024年第1期63-73,共11页
Electrocatalytic glucose oxidation reaction(GOR)has attracted much attention owing to its crucial role in biofuel cell fabrication.Herein,we load MoO_(3)nanoparticles on carbon nanotubes(CNTs)and use a discharge proce... Electrocatalytic glucose oxidation reaction(GOR)has attracted much attention owing to its crucial role in biofuel cell fabrication.Herein,we load MoO_(3)nanoparticles on carbon nanotubes(CNTs)and use a discharge process to prepare a noblemetal-free MC-60 catalyst containing MoO_(3),Mo_(2)C,and a Mo_(2)C–MoO_(3)interface.In the GOR,MC-60 shows activity as high as 745μA/(mmol/L cm^(2)),considerably higher than those of the Pt/CNT(270μA/(mmol/L cm^(2)))and Au/CNT catalysts(110μA/(mmol/L cm^(2))).In the GOR,the response minimum on MC-60 is as low as 8μmol/L,with a steady-state response time of only 3 s.Moreover,MC-60 has superior stability and anti-interference ability to impurities in the GOR.The better performance of MC-60 in the GOR is attributed to the abundant Mo sites bonding to C and O atoms at the MoO_(3)–Mo_(2)C interface.These Mo sites create active sites for promoting glucose adsorption and oxidation,enhancing MC-60 performance in the GOR.Thus,these results help to fabricate more effi cient noble-metal-free catalysts for the fabrication of glucose-based biofuel cells. 展开更多
关键词 Interface eff ect ELectROCATALYSIS Molybdenum oxide GLUCOSE Oxidation reaction
在线阅读 下载PDF
Sensor monitoring and online measurement correction in electric capacitance tomography system
11
作者 张惠良 荣冈 《化工学报》 EI CAS CSCD 北大核心 2005年第4期664-667,共4页
The recalibration of electrical capacitance tomography (ECT) system is one of the key problems in keeping the system running steadily.However, for engineering application in solids/gas transport,online calibration can... The recalibration of electrical capacitance tomography (ECT) system is one of the key problems in keeping the system running steadily.However, for engineering application in solids/gas transport,online calibration can not be implemented and the data from this sensor may be unreliable due to the sensor pipe interior wall abrasion during pneumatic transport,so the solids concentration calculated from the reconstructed image based on these data will be highly inaccurate.The simulations show that, the inter-electrode relative capacitance variation of electrode pair spacing 1 is the most sensitive to the abrasion of sensor pipe interior wall, so this relative capacitance variation when the sensor is filled with air can be used as an indicator demanding offline system recalibration when the wall abrasion goes significant.Furthermore, while the pipe interior wall abrasion is not very serious, online correcting measured inter-electrode capacitance with wall capacitance variation can improve the accuracy of concentration calculation. 展开更多
关键词 传感器 在线测量技术 ect系统 流体 电极 电容层析成像系统
在线阅读 下载PDF
Optical fiber-based power and data delivery system for high voltage electronic current transformer
12
作者 邱红辉 段雄英 邹积岩 《Journal of Shanghai University(English Edition)》 CAS 2008年第3期268-273,共6页
This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The desi... This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request. 展开更多
关键词 high voltage electronic current transformer ect optical power supply delivery system photovoltaic powerconverters supervisory functions
在线阅读 下载PDF
ECT压缩机组控制系统在合成氨装置中的应用 被引量:1
13
作者 许文荣 姚志洋 +1 位作者 张斌宾 高愚含 《石油化工自动化》 CAS 2024年第6期33-37,共5页
氨制冷压缩机和合成气压缩机(ECT)机组的运行稳定性直接影响合成氨装置的运行效果和产品质量。介绍了ECT机组控制系统的特点及功能,通过该控制系统优化拟合喘振线,在开工阶段有效实现了压缩机的防喘振控制;经过比对该控制系统优化后的... 氨制冷压缩机和合成气压缩机(ECT)机组的运行稳定性直接影响合成氨装置的运行效果和产品质量。介绍了ECT机组控制系统的特点及功能,通过该控制系统优化拟合喘振线,在开工阶段有效实现了压缩机的防喘振控制;经过比对该控制系统优化后的氨制冷压缩机和合成气压缩机平稳生产日均值产量和能耗数据,结果表明:该系统减少了不必要的能耗,提升了自动化操作水平,具有稳定性和可靠性。 展开更多
关键词 ect机组控制系统 防喘振控制 速度控制 性能控制 解耦控制 氨制冷压缩机 合成气压缩机
在线阅读 下载PDF
基于1-bit压缩感知非凸算法的平面ECT图像重建
14
作者 唐志浩 张立峰 《计量学报》 CSCD 北大核心 2024年第12期1797-1803,共7页
为提高平面电容成像系统的成像质量并提高重建速度,提出了一种基于1-bit压缩感知(1-bit CS)非凸算法的平面ECT图像重建方法。首先,利用离散余弦基(DCT)对灰度值进行稀疏表示;其次,引入极大极小凹惩罚(MCP)作为正则化项,并建立1-bit CS ... 为提高平面电容成像系统的成像质量并提高重建速度,提出了一种基于1-bit压缩感知(1-bit CS)非凸算法的平面ECT图像重建方法。首先,利用离散余弦基(DCT)对灰度值进行稀疏表示;其次,引入极大极小凹惩罚(MCP)作为正则化项,并建立1-bit CS MCP正则化模型;然后,通过MCP非凸算法迭代更新对偶解的近端算子,以求取最优对偶解;最后,根据对偶解求出重建灰度值并进行图像重建。仿真与实验结果表明,相比于Tikhonov算法、Landweber算法及传统压缩感知算法,所提方法得到的重建图像平均相对误差和相关系数分别为0.0496和0.9435,平均重建时间约为0.1723 s,均优于其他3种算法,缺陷还原度及重建速度有明显提升。 展开更多
关键词 材料缺陷检测 平面电容成像 ect图像重建 1-bit压缩感知 极大极小凹惩罚 非凸算法
在线阅读 下载PDF
基于Sigmoid函数的ECT灵敏度预处理
15
作者 周广明 王伊凡 《太赫兹科学与电子信息学报》 2024年第12期1383-1387,1420,共6页
电容层析成像(ECT)图像重建算法利用敏感度矩阵作为先验知识,反演管道内介质的分布情况,因此,灵敏度矩阵对图像重建的质量起着至关重要的作用。由于ECT传感器具有软场特性,场域内的灵敏度分布并不均匀,传感器中心区域与边缘区域差异过大... 电容层析成像(ECT)图像重建算法利用敏感度矩阵作为先验知识,反演管道内介质的分布情况,因此,灵敏度矩阵对图像重建的质量起着至关重要的作用。由于ECT传感器具有软场特性,场域内的灵敏度分布并不均匀,传感器中心区域与边缘区域差异过大,影响重建图像质量。本文提出一种基于Sigmoid函数的灵敏度预处理方法,由仿真实验结果可知,该方法能显著提高灵敏度矩阵的均匀性,并大大提高重建图像的质量:图像空间误差(ISE)降低0.3825;图像相对误差(RE)降低0.3865;相关系数(CC)提升0.0608,验证了此方法在ECT图像重建中的可行性。 展开更多
关键词 两相流 图像重建 传感器 灵敏度预处理 电容层析成像(ect)
在线阅读 下载PDF
用于超音速分离流场参数测量的ECT图像重建算法优化
16
作者 王世伟 王超 +1 位作者 郭琪 丁红兵 《仪器仪表学报》 EI CAS CSCD 北大核心 2024年第9期111-119,共9页
针对电容层析成像系统(ECT)用于超音速分离器内气液两相流场参数测量时逆问题病态性导致图像重建质量不高的问题,基于引导图像滤波和正则化理念,提出了一种新的ECT图像重建算法。首先分别利用L_(2)正则化和L_(p)(0<p<1)正则化对... 针对电容层析成像系统(ECT)用于超音速分离器内气液两相流场参数测量时逆问题病态性导致图像重建质量不高的问题,基于引导图像滤波和正则化理念,提出了一种新的ECT图像重建算法。首先分别利用L_(2)正则化和L_(p)(0<p<1)正则化对介质分布重建,在此基础上,将L_(2)正则化和L_(p)正则化的重构图像分别作为引导图像滤波的引导图和输入图,进行滤波输出。仿真和实验条件下,所提算法、L_(2)正则化算法和L_(p)正则化算法的图像重建结果表明,前者可以同时结合后两种算法的平滑性和稀疏性优势,重构的介质分布更加准确,图像伪影更少。与其它两种方法相比,重建图像平均相关系数分别提高了17.01%和7.15%。所提算法在ECT测量超音速分离器气液两相流场参数方面具有良好应用前景。 展开更多
关键词 超音速分离器 图像重建 ect系统 正则化方法 引导图像滤波
原文传递
Treatment Resistant Depression, Ketamine versus ECT
17
作者 Smita Agarkar 《Open Journal of Psychiatry》 2024年第4期380-385,共6页
Recent studies have highlighted the increase in treatment resistant depression. Of particular concern is the rising trend of depression and suicide rates among Young Adults. Ketamine was approved for treatment resista... Recent studies have highlighted the increase in treatment resistant depression. Of particular concern is the rising trend of depression and suicide rates among Young Adults. Ketamine was approved for treatment resistant depression in 2019 by the US Food and Drug Administration. It received an additional indication for treatment of suicidality. While intranasal Ketamine is approved for depression, recent data about intravenous infusion of Ketamine in controlled inpatient settings has been promising. ECT has a long-standing trend for being used for resistant depression and recent comparison trials have revealed positive results when head-to-head comparisons are made with Ketamine. Future studies need to focus on patient selection and wherein treatment algorithm should Ketamine be selected as treatment modality. 展开更多
关键词 Treatment Resistant Depression KETAMINE ect
暂未订购
Review on the pharmacological mechanisms and novel drug delivery system of vitexin
18
作者 Jinghui Yang Mengyuan Zhao +2 位作者 Hongyue Wang Xinnan Li Xiangrong Zhang 《Journal of Polyphenols》 2024年第4期133-140,共8页
Vitexin is a natural phytofl avonoid glycoside extracted from the leaves of vitexin,a plant of the Verbenaceae family,which is an active ingredient in many traditional Chinese medicines and is present in a wide range ... Vitexin is a natural phytofl avonoid glycoside extracted from the leaves of vitexin,a plant of the Verbenaceae family,which is an active ingredient in many traditional Chinese medicines and is present in a wide range of medicinal plants.In this review,pharmacological eff ects including anti-infl ammatory,diabetes mellitus are described.The novel formulation of vitexin of nano delivery and hybrid micelles are elucidated. 展开更多
关键词 VITEXIN pharmacological eff ect BIOAVAILABILITY
在线阅读 下载PDF
基于同伦摄动的三维ECT图像重建研究
19
作者 刘鸽 《变频器世界》 2024年第3期77-81,共5页
ECT技术的研究可分为二维ECT技术和三维ECT技术,目前关于ECT技术的研究大多是二维。二维ECT传感器由于管道外仅布置一层测量极板,其获得的图像为管道截面图,二维ECT技术带来的局限性导致了无法获得管道内分布的三维信息。三维ECT传感器... ECT技术的研究可分为二维ECT技术和三维ECT技术,目前关于ECT技术的研究大多是二维。二维ECT传感器由于管道外仅布置一层测量极板,其获得的图像为管道截面图,二维ECT技术带来的局限性导致了无法获得管道内分布的三维信息。三维ECT传感器相较于二维ECT传感器来说在管道外布置的极板层数增多,以便于获得更多的投影数据。三维ECT技术可以通过三维投影数据反演出管道内部的三维介质分布信息,重建结果也更加的接近真实分布。Landweber算法是最常用的图像重建算法,但该方法一般需要大量的选代次数才能够获得较好的重建图像。本文推导了基于同伦摄动方法的ECT选代重建公式。针对分布不同最佳选代次数也不同的问题,提出了一种自适应选代终止条件。基于仿真数据和实测数据的重建结果,均验证了所提方法的有效性。与Landweber算法相比,所提方法可给出更好的重建效果。 展开更多
关键词 三维ect 同伦摄动 自适应选代终止条件
在线阅读 下载PDF
12极板直接三维ECT图像重建仿真 被引量:8
20
作者 颜华 宁秀坤 +1 位作者 王伊凡 周英钢 《沈阳工业大学学报》 EI CAS 北大核心 2012年第5期542-548,共7页
为克服间接三维ECT系统轴向分辨能力低这一缺陷,进行了直接三维ECT重建技术的研究.将12个极板分三层布置,相邻层极板有45°角的相对旋转.不但测量同层极板对的电容值,还要测量不同层极板对的电容值.三维图像直接在重建过程中产生,... 为克服间接三维ECT系统轴向分辨能力低这一缺陷,进行了直接三维ECT重建技术的研究.将12个极板分三层布置,相邻层极板有45°角的相对旋转.不但测量同层极板对的电容值,还要测量不同层极板对的电容值.三维图像直接在重建过程中产生,与经过二维断层图的间接三维重建图像截然不同.建立了传感器的三维有限元模型,分析了传感器的三维敏感场.采用线性反投影算法以及有限元分析法获得的三维灵敏度矩阵和电容测量仿真数据,实现了直接三维ECT图像重建.重建结果显示了直接三维ECT具有良好的轴向分辨能力. 展开更多
关键词 ect系统 传感器结构 直接三维图像重建 线性反投影 有限元分析 敏感场 轴向分辨力 仿真研究
在线阅读 下载PDF
上一页 1 2 43 下一页 到第
使用帮助 返回顶部