Electrocardiogram(ECG)electrodes are conductive pads applied to the skin to measure cardiac activity.Ag/AgCl electrodes are the commercial product which widely used to obtain ECGs.When monitoring the ECG in a hot spri...Electrocardiogram(ECG)electrodes are conductive pads applied to the skin to measure cardiac activity.Ag/AgCl electrodes are the commercial product which widely used to obtain ECGs.When monitoring the ECG in a hot spring,Ag/AgCl electrodes must be waterproofed;however,this is time-consuming,and the adhesive may tear the skin on removal.For solving the problem,we developed the carbon pencil lead(CPL)electrodes for use in hot springs.Both CPL and Ag/AgCl electrodes were connected to ECG100C’s cables.The Performance was evaluated in three conditions as following:hot spring water with and without bubble,and in cold water.In each environment,the procedure was followed by three different protocols that are recording from the dry condition,hot spring water immersion with and without movement,post hot spring water condition.Under dry and wet conditions,both electrodes can obtain the waveform of the ECG signal in which all PQRST waves were identifiable.Nevertheless,the signal quality of both types of electrodes was different in water immersion with and without movement.The overall morphology obtained by Ag/AgCl electrodes was unstable higher than that of CPL electrodes in immersion without movement condition.The CPL electrodes provided better ECG waveform quality compared to Ag/AgCl electrodes in which the ECG signal had high waveforms distortion in water immersion with movement condition.展开更多
Facing the body's EEG(electroencephalograph, 0.5–100 Hz, 5–100 μV) and ECG's(electrocardiogram,〈 100 Hz, 0.01–5 mV) micro signal detection requirement, this paper develops a pervasive application micro sign...Facing the body's EEG(electroencephalograph, 0.5–100 Hz, 5–100 μV) and ECG's(electrocardiogram,〈 100 Hz, 0.01–5 mV) micro signal detection requirement, this paper develops a pervasive application micro signal detection ASIC chip with the chopping modulation/demodulation method. The chopper-stabilization circuit with the RRL(ripple reduction loop) circuit is to suppress the ripple voltage, which locates at the single-stage amplifier's outputting terminal. The single-stage chopping core's noise has been suppressed too, and it is beneficial for suppressing noises of post-circuit. The chopping core circuit uses the PFB(positive feedback loop) to increase the inputting resistance, and the NFB(negative feedback loop) to stabilize the 40 dB intermediate frequency gain. The cascaded switch-capacitor sample/hold circuit has been used for deleting spike noises caused by non-ideal MOS switches, and the VGA/BPF(voltage gain amplifier/band pass filter) circuit is used to tune the chopper system's gain/bandwidth digitally. Assisted with the designed novel dry-electrode, the real test result of the chopping amplifying circuit gives some critical parameters: 8.1 μW/channel, 0.8 μVrms(@band-widthD100 Hz), 4216–11220 times digitally tuning gain range, etc. The data capture system uses the NI CO's data capturing DAQmx interface,and the captured micro EEG/ECG's waves are real-time displayed with the PC-Labview. The proposed chopper system is a unified EEG/ECG signal's detection instrument and has a critical real application value.展开更多
基金Korea Institute for Advancement of Technology(KIAT)grant funded by the Korea Government(MOTIE)(P0012724,The Competency Development Program for Industry Specialist)and the Soonchunhyang University Research Fund.
文摘Electrocardiogram(ECG)electrodes are conductive pads applied to the skin to measure cardiac activity.Ag/AgCl electrodes are the commercial product which widely used to obtain ECGs.When monitoring the ECG in a hot spring,Ag/AgCl electrodes must be waterproofed;however,this is time-consuming,and the adhesive may tear the skin on removal.For solving the problem,we developed the carbon pencil lead(CPL)electrodes for use in hot springs.Both CPL and Ag/AgCl electrodes were connected to ECG100C’s cables.The Performance was evaluated in three conditions as following:hot spring water with and without bubble,and in cold water.In each environment,the procedure was followed by three different protocols that are recording from the dry condition,hot spring water immersion with and without movement,post hot spring water condition.Under dry and wet conditions,both electrodes can obtain the waveform of the ECG signal in which all PQRST waves were identifiable.Nevertheless,the signal quality of both types of electrodes was different in water immersion with and without movement.The overall morphology obtained by Ag/AgCl electrodes was unstable higher than that of CPL electrodes in immersion without movement condition.The CPL electrodes provided better ECG waveform quality compared to Ag/AgCl electrodes in which the ECG signal had high waveforms distortion in water immersion with movement condition.
基金Project supported by the National Natural Science Foundation of China(Nos.61527815,31500800,61501426,61471342)the National Key Basic Research Plan(No.2014CB744600)+1 种基金the Beijing Science and Technology Plan(No.Z141100000214002)the Chinese Academy of Sciences’Key Project(No.KJZD-EW-L11-2)
文摘Facing the body's EEG(electroencephalograph, 0.5–100 Hz, 5–100 μV) and ECG's(electrocardiogram,〈 100 Hz, 0.01–5 mV) micro signal detection requirement, this paper develops a pervasive application micro signal detection ASIC chip with the chopping modulation/demodulation method. The chopper-stabilization circuit with the RRL(ripple reduction loop) circuit is to suppress the ripple voltage, which locates at the single-stage amplifier's outputting terminal. The single-stage chopping core's noise has been suppressed too, and it is beneficial for suppressing noises of post-circuit. The chopping core circuit uses the PFB(positive feedback loop) to increase the inputting resistance, and the NFB(negative feedback loop) to stabilize the 40 dB intermediate frequency gain. The cascaded switch-capacitor sample/hold circuit has been used for deleting spike noises caused by non-ideal MOS switches, and the VGA/BPF(voltage gain amplifier/band pass filter) circuit is used to tune the chopper system's gain/bandwidth digitally. Assisted with the designed novel dry-electrode, the real test result of the chopping amplifying circuit gives some critical parameters: 8.1 μW/channel, 0.8 μVrms(@band-widthD100 Hz), 4216–11220 times digitally tuning gain range, etc. The data capture system uses the NI CO's data capturing DAQmx interface,and the captured micro EEG/ECG's waves are real-time displayed with the PC-Labview. The proposed chopper system is a unified EEG/ECG signal's detection instrument and has a critical real application value.