期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Comparative evaluation of retentive capacity of three different attachment systems for implant retained overdentures:An in vitro study
1
作者 Radha Chauhan Narendra Padiyar +2 位作者 Pragati Kaurani Ajay Gupta Sachin Chauhan 《World Journal of Methodology》 2025年第3期114-123,共10页
BACKGROUND The primary issue in managing edentulous patients is the severely resorbed mandibular ridge,particularly in older individuals with diminished adaptive capacities.This compromised situation leads to the fabr... BACKGROUND The primary issue in managing edentulous patients is the severely resorbed mandibular ridge,particularly in older individuals with diminished adaptive capacities.This compromised situation leads to the fabrication of inadequate dentures that lack retention and stability,potentially causing psychosocial issues.AIM To determine the difference in retentive capacity between three attachment systems in implant-retained overdentures.METHODS Three edentulous mandibular models were fabricated using heat-cured polymethacrylate resin,with two implant replicas placed in the intra-foraminal region of each model.30 acrylic resin mandibular overdentures were fabricated with provisions for three different overdenture attachment systems:A prefabricated ball/O-ring attachment,a locator attachment system,and an equator attachment system.Each model was subjected to 15000 pulls using a universal testing machine to remove the overdenture from the acrylic model and the force data were recorded.RESULTS The ball/O-ring attachment system demonstrated superior retentive capacity for 15 years,while the locator and equator attachment systems maintained excellent retentive capacity for 5 years.CONCLUSION The ball/O-ring attachment system outperformed better than the other two attachment systems regarding retentive capacity.The locator and equator attachment systems presented sufficient retentive abilities until 15000 cycles.After 7500 cycles,significant differences in retentive force between the systems evolved. 展开更多
关键词 DENTURES Overdenture attachment systems EQUATOR dislodging cycles Retentive capacity
暂未订购
Spontaneous dislodgment of a peritoneal dialysis catheter inserted using the Seldinger technique:A case report
2
作者 Ruo-Yu Wu Yao Tan +3 位作者 Hang Li Yu-Rong Zou Xiu-Ling Chen Jin Chen 《World Journal of Clinical Cases》 SCIE 2024年第21期4789-4793,共5页
BACKGROUND Peritoneal dialysis(PD)is an important renal replacement therapy in patients with end-stage renal disease.PD catheters remain the lifeline for patients undergoing PD.The catheter technique survival rate is ... BACKGROUND Peritoneal dialysis(PD)is an important renal replacement therapy in patients with end-stage renal disease.PD catheters remain the lifeline for patients undergoing PD.The catheter technique survival rate is considered a core PD outcome domain.CASE SUMMARY The PD catheter spontaneously dislodged in a patient undergoing PD during regular fluid exchange without pain.Abdominal computed tomography showed a tunnel infection.A double-cuff straight Tenckhoff catheter had been inserted using the Seldinger technique.Before this incident,the patient had a history of tunnel infections.We speculate that recurrent tunnel infections and catheter insertion using the Seldinger technique may have led to catheter dislodgement.CONCLUSION The present case suggests that clinicians should more rigorously assess the persistence of catheter-related infections concerning the potential complications arising from catheter dislodgement associated with the Seldinger technique. 展开更多
关键词 CATHETER DISLODGMENT Seldinger technique INFECTION Peritoneal dialysis Case report
暂未订购
Recognizing and preventing complications regarding bioresorbable scaffolds during coronary interventions
3
作者 George Latsios Leonidas Koliastasis +1 位作者 Konstantinos Toutouzas Kostas Tsioufis 《World Journal of Cardiology》 2024年第9期508-511,共4页
The evolution of coronary intervention techniques and equipment has led to more sophisticated procedures for the treatment of highly complex lesions.However,as a result,the risk of complications has increased,which ar... The evolution of coronary intervention techniques and equipment has led to more sophisticated procedures for the treatment of highly complex lesions.However,as a result,the risk of complications has increased,which are mostly iatrogenic and often include equipment failure.Stent dislodgement warrants vigilance for the early diagnosis and a stepwise management approach is required to either expand or retrieve the lost stent.In the era of bioresorbable scaffolds that are not radiopaque,increased caution is required.Intravascular imaging may assist in detecting the lost scaffold in cases of no visibility fluoroscopically.Adequate lesion preparation is the key to minimizing the possibility of equipment loss;however,in the case that it occurs,commercially available and improvised devices and techniques may be applied. 展开更多
关键词 Bioresorbable scaffolds Stent dislodgement Complication prevention Coronary complications Equipment failure
暂未订购
前牙桩冠脱落危险因素的logistic回归分析 被引量:7
4
作者 韩东 战德松 +1 位作者 孙强 常春荣 《现代口腔医学杂志》 CAS CSCD 北大核心 2006年第2期145-146,共2页
目的探讨前牙桩冠脱落的危险因素。方法对123位前牙桩冠修复患者(131颗患牙)进行病例—对照研究,并用单因素和多因素非条件logistic回归模型分析,探讨前牙桩冠修复脱落的危险因素。结果最终进入logistic回归模型的因素有深覆牙合、食物... 目的探讨前牙桩冠脱落的危险因素。方法对123位前牙桩冠修复患者(131颗患牙)进行病例—对照研究,并用单因素和多因素非条件logistic回归模型分析,探讨前牙桩冠修复脱落的危险因素。结果最终进入logistic回归模型的因素有深覆牙合、食物嵌塞、咬合习惯、牙列缺损未修复、患牙缺损达龈下,OR值分别为7.386、8.121、7.084、13.258和15.583。结论提示以上因素可能与桩冠修复脱落的发生有关,并且是其危险因素。 展开更多
关键词 桩冠 危险因素 LOGISTIC回归分析
暂未订购
Technical problems produced by the Bravo pH test in nonerosive reflux disease patients 被引量:2
5
作者 Andrés de Hoyos Edgar Alain Esparza 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第25期3183-3186,共4页
AIM: To evaluate the technical failures of the Bravo pH test in a population with nonerosive gastroesophageal reflux disease. METHODS: Over the course of a year, we prospectively studied a population of 66 nonerosive ... AIM: To evaluate the technical failures of the Bravo pH test in a population with nonerosive gastroesophageal reflux disease. METHODS: Over the course of a year, we prospectively studied a population of 66 nonerosive reflux disease patients who received a Bravo pH test. The number and frequency of all technical failures were documented, quantified and analyzed. RESULTS: A total of 66 patients, with a mean age of 41.7 years, were studied. Technical failures occurred in 15.15% of the sample. The most frequent failures were due to poor data reception (4.5%), early dislodgement (4.5%) and capsule removal (6.1%). CONCLUSION: The Bravo capsule pH test involves a low but non-negligible rate of technical problems, a fact that must always be considered by physicians. 展开更多
关键词 Bravo test Capsule dislodgement Nonerosive reflux disease Poor data reception Technical problems
暂未订购
Unreported complication of Bravo p H capsule dislodged into the pyriform sinus 被引量:1
6
作者 Akash Kumar Elisabeth Kramer Sita Chokhavatia 《World Journal of Gastrointestinal Endoscopy》 CAS 2015年第5期573-574,共2页
We report an unexpected, previously unreported complication of Bravo p H capsule dislodgement. During Bravo p H testing of a 44-year-old man with gastroesophageal reflux disease, we were unable to endoscopically visua... We report an unexpected, previously unreported complication of Bravo p H capsule dislodgement. During Bravo p H testing of a 44-year-old man with gastroesophageal reflux disease, we were unable to endoscopically visualize the capsule attached to the esophageal wall after deployment. After multiple attempts to detect the capsule, it was visualized in the left pyriform sinus. As there was significant risk for pulmonary dislodgement, ENT and pulmonary physicians were immediately consulted to review options for safe removal. Ultimately, ENT successfully retrieved the capsule with a foreign body removal forceps. The Bravo p H test is generally a well-tolerated diagnostic tool used to confirm the presence of abnormal esophageal acid reflux. While few complications have been reported, technical difficulties can occur, including poor data reception, misplacement, and early dislodgement. Rarely, more serious complications can occur, ranging from esophageal wall trauma to capsule aspiration. Gastroenterologists performing this procedure should be aware of the low, but nontrivial, risk of complications. 展开更多
关键词 GASTROESOPHAGEAL REFLUX disease EsophagealpH monitoring BRAVO CAPSULE Dislodgement ESOPHAGOGASTRODUODENOSCOPY
暂未订购
Unique presentation of Twiddler's syndrome
7
作者 Valay Parikh Emad A Barsoum +3 位作者 Rewais Morcus Basem Azab James Lafferty Jeffrey Kohn 《World Journal of Cardiology》 CAS 2013年第6期207-209,共3页
We present a rare case of Twiddler's syndrome diagnosed in an asymptomatic patient on a routine follow up.This case reiterates the need for frequent monitoring of the implanted device.In addition,it was detected 4... We present a rare case of Twiddler's syndrome diagnosed in an asymptomatic patient on a routine follow up.This case reiterates the need for frequent monitoring of the implanted device.In addition,it was detected 4 years after implantation of an automatic implantable cardioverter defibrillator.This late representation is extremely uncommon. 展开更多
关键词 Twiddler’s SYNDROME DEFIBRILLATOR COMPLICATION MALFUNCTION Lead dislodgement
暂未订购
Characterisation of Geomechanical Properties of Bentonite Clay Used for Plug and Abandonment Operations of Coal Seam Gas Wells
8
作者 Heinz-Gerd Holl Alexander Scheuermann 《Journal of Minerals and Materials Characterization and Engineering》 2018年第2期218-234,共17页
Compressed bentonite in the form of pellets or plugs is used for the abandonment of production wells for the oil and gas industry. The design of the abandonment systems is based on the hydro-mechanical behaviour of th... Compressed bentonite in the form of pellets or plugs is used for the abandonment of production wells for the oil and gas industry. The design of the abandonment systems is based on the hydro-mechanical behaviour of the compressed bentonite defined by mechanical parameters that are used from published data rather than quantified for the used material by laboratory investigations. This paper presents an experimental study on characterising the swelling and shear strength behaviour of raw and polymer (polyvinylpyrrolidone, PVP) treated bentonite. Dislodgement tests consist of three hydrated bentonite plugs inserted in steel casings with the failure mechanism characterised. The bentonite used comes from a local mine (in Queensland, Australia) and is comparable to other bentonites usually used for the abandonment of wells or for other problems where mineral sealing is required (e.g. basal clay barriers of landfills). The experiments have shown that polymer treated bentonite shows significantly larger shear strengths than raw bentonite with simultaneously less swelling. More compressed samples also showed higher shear strengths and less swelling. The dislodgement tests have characterised for the first time the cascaded failure mechanism of a series of plugs forming an abandonment system. This investigation is the first step towards the development of an improved design for abandonment systems for wells using bentonite plugs. 展开更多
关键词 BENTONITE Plugs SWELLING Pressure SHEAR Testing Mechanical Dislodgement
暂未订购
上一页 1 下一页 到第