This paper presents a method for estimating the parameters of DC-link capacitors in three-level NPC voltage source inverters(3L-NPC-VSI)used in grid-tied systems.The technique uses the signals generated by the intermo...This paper presents a method for estimating the parameters of DC-link capacitors in three-level NPC voltage source inverters(3L-NPC-VSI)used in grid-tied systems.The technique uses the signals generated by the intermodulation caused by the PWM strategy and converter topology interaction to estimate the capacitor parameters of the converter DC-link.It utilizes an observer-based structure consisting of a recursive noninteger sliding discrete Fourier transform(rnSDFT)and an RLS filter improved with a forgetting factor(oSDFT-RLS)to accurately estimate the capacitance and equivalent series resistance(ESR).Importantly,this method does not require additional sensors beyond those already installed in off-the-shelf 3L-NPC-VSI systems,ensuring its noninvasiveness.Furthermore,the oSDFTRLS estimates capacitor parameters in the time-frequency domain,enabling the tracking of capacitor degradation and predicting potential faults.Experimental results from the laboratory setup demonstrate the effectiveness of the proposed condition monitoring method.展开更多
The application of traditional synchronous measurement methods is limited by frequent fluctuations of electrical signals and complex frequency components in distribution networks.Therefore,it is critical to find solut...The application of traditional synchronous measurement methods is limited by frequent fluctuations of electrical signals and complex frequency components in distribution networks.Therefore,it is critical to find solutions to the issues of multifrequency parameter estimation and synchronous measurement estimation accuracy in the complex environment of distribution networks.By utilizing the multifrequency sensing capabilities of discrete Fourier transform signals and Taylor series for dynamic signal processing,a multifrequency signal estimation approach based on HT-IpDFT-STWLS(HIpST)for distribution networks is provided.First,by introducing the Hilbert transform(HT),the influence of noise on the estimation algorithm is reduced.Second,signal frequency components are obtained on the basis of the calculated signal envelope spectrum,and the interpolated discrete Fourier transform(IpDFT)frequency coarse estimation results are used as the initial values of symmetric Taylor weighted least squares(STWLS)to achieve high-precision parameter estimation under the dynamic changes of the signal,and the method increases the number of discrete Fourier.Third,the accuracy of this proposed method is verified by simulation analysis.Data show that this proposed method can accurately achieve the parameter estimation of multifrequency signals in distribution networks.This approach provides a solution for the application of phasor measurement units in distribution networks.展开更多
This paper presents a new method for the detection and parameter estimation of multicomponent LFM signals based on the fractional Fourier transform. For the optimization in the fractional Fourier domain, an algorithm ...This paper presents a new method for the detection and parameter estimation of multicomponent LFM signals based on the fractional Fourier transform. For the optimization in the fractional Fourier domain, an algorithm based on Quasi-Newton method is proposed which consists of two steps of searching, leading to a reduction in computation without loss of accuracy. And for multicomponent signals, we further propose a signal separation technique in the fractional Fourier domain which can effectively suppress the interferences on the detection of the weak components brought by the stronger components. The statistical analysis of the estimate errors is also performed which perfects the method theoretically, and finally, simulation results are provided to show the validity of our method.展开更多
A concise fractional Fourier transform (CFRFT) is proposed to detect the linear frequency-modulated (LFM) signal with low signal to noise ratio (SNR). The frequency axis in time-frequency plane of the CFRFT is r...A concise fractional Fourier transform (CFRFT) is proposed to detect the linear frequency-modulated (LFM) signal with low signal to noise ratio (SNR). The frequency axis in time-frequency plane of the CFRFT is rotated to get the spectrum of the signal in different an- gles using chirp multiplication and Fourier transform (FT). For LFM signal which distributes as a straight line in time-frequency plane, the CFRFT can gather the energy in the corresponding angle as a peak and improve the detection SNR, thus the LFM signal of low SNR can be de- tected. Meanwhile, the location of the peak value relates to the parameters of the LFM signal. Numerical simulations and experimental results show that, the proposed method can be used to efficiently detect the LFM signal masked by noise and to estimate the signal's parameters accurately. Compared with the conventional fractional Fourier transform (FRFT), the CFRFT reduces the transform complexity and improves the real-time detection performance of LFM signal.展开更多
针对甚小频偏线性调频(very minimum frequency shift-linear frequency modulation,VMFS-LFM)信号对应的分数阶傅里叶(fractional fourier transform,FrFT)域估计参数的绝对值接近1而导致估计性能降低的问题,在借鉴基于FrFT的LFM信号...针对甚小频偏线性调频(very minimum frequency shift-linear frequency modulation,VMFS-LFM)信号对应的分数阶傅里叶(fractional fourier transform,FrFT)域估计参数的绝对值接近1而导致估计性能降低的问题,在借鉴基于FrFT的LFM信号参数估计方法的基础上,采用m倍抽取(m time decimation,mTD)作为预处理方法,提出基于mTD-FrFT的VMFS-LFM信号参数估计方法.理论分析和实验结果表明:mTD预处理过程可增大VMFS-LFM信号和近参数多分量LFM信号的调频斜率在FrFT域的分辨率,使基于mTD-FrFT的参数估计方法可对VMFS-LFM信号和相近参数多分量LFM信号进行有效参数估计.展开更多
基金funded by the Brazilian National Council for Scientific and Technological Development—CNPq(CNPq grant number 405997/2022-1)supported by the EMBRAPII VIRTUS Competence Center in Intelligent Hardware for Industry—VIRTUS-CC(MCTI grant number 055/2023).
文摘This paper presents a method for estimating the parameters of DC-link capacitors in three-level NPC voltage source inverters(3L-NPC-VSI)used in grid-tied systems.The technique uses the signals generated by the intermodulation caused by the PWM strategy and converter topology interaction to estimate the capacitor parameters of the converter DC-link.It utilizes an observer-based structure consisting of a recursive noninteger sliding discrete Fourier transform(rnSDFT)and an RLS filter improved with a forgetting factor(oSDFT-RLS)to accurately estimate the capacitance and equivalent series resistance(ESR).Importantly,this method does not require additional sensors beyond those already installed in off-the-shelf 3L-NPC-VSI systems,ensuring its noninvasiveness.Furthermore,the oSDFTRLS estimates capacitor parameters in the time-frequency domain,enabling the tracking of capacitor degradation and predicting potential faults.Experimental results from the laboratory setup demonstrate the effectiveness of the proposed condition monitoring method.
基金supported by the State Grid Corporation of China Headquarters Management Science and Technology Project(No.526620200008).
文摘The application of traditional synchronous measurement methods is limited by frequent fluctuations of electrical signals and complex frequency components in distribution networks.Therefore,it is critical to find solutions to the issues of multifrequency parameter estimation and synchronous measurement estimation accuracy in the complex environment of distribution networks.By utilizing the multifrequency sensing capabilities of discrete Fourier transform signals and Taylor series for dynamic signal processing,a multifrequency signal estimation approach based on HT-IpDFT-STWLS(HIpST)for distribution networks is provided.First,by introducing the Hilbert transform(HT),the influence of noise on the estimation algorithm is reduced.Second,signal frequency components are obtained on the basis of the calculated signal envelope spectrum,and the interpolated discrete Fourier transform(IpDFT)frequency coarse estimation results are used as the initial values of symmetric Taylor weighted least squares(STWLS)to achieve high-precision parameter estimation under the dynamic changes of the signal,and the method increases the number of discrete Fourier.Third,the accuracy of this proposed method is verified by simulation analysis.Data show that this proposed method can accurately achieve the parameter estimation of multifrequency signals in distribution networks.This approach provides a solution for the application of phasor measurement units in distribution networks.
文摘This paper presents a new method for the detection and parameter estimation of multicomponent LFM signals based on the fractional Fourier transform. For the optimization in the fractional Fourier domain, an algorithm based on Quasi-Newton method is proposed which consists of two steps of searching, leading to a reduction in computation without loss of accuracy. And for multicomponent signals, we further propose a signal separation technique in the fractional Fourier domain which can effectively suppress the interferences on the detection of the weak components brought by the stronger components. The statistical analysis of the estimate errors is also performed which perfects the method theoretically, and finally, simulation results are provided to show the validity of our method.
基金supported by the National Natural Science Foundation of China(11434012)
文摘A concise fractional Fourier transform (CFRFT) is proposed to detect the linear frequency-modulated (LFM) signal with low signal to noise ratio (SNR). The frequency axis in time-frequency plane of the CFRFT is rotated to get the spectrum of the signal in different an- gles using chirp multiplication and Fourier transform (FT). For LFM signal which distributes as a straight line in time-frequency plane, the CFRFT can gather the energy in the corresponding angle as a peak and improve the detection SNR, thus the LFM signal of low SNR can be de- tected. Meanwhile, the location of the peak value relates to the parameters of the LFM signal. Numerical simulations and experimental results show that, the proposed method can be used to efficiently detect the LFM signal masked by noise and to estimate the signal's parameters accurately. Compared with the conventional fractional Fourier transform (FRFT), the CFRFT reduces the transform complexity and improves the real-time detection performance of LFM signal.
文摘针对甚小频偏线性调频(very minimum frequency shift-linear frequency modulation,VMFS-LFM)信号对应的分数阶傅里叶(fractional fourier transform,FrFT)域估计参数的绝对值接近1而导致估计性能降低的问题,在借鉴基于FrFT的LFM信号参数估计方法的基础上,采用m倍抽取(m time decimation,mTD)作为预处理方法,提出基于mTD-FrFT的VMFS-LFM信号参数估计方法.理论分析和实验结果表明:mTD预处理过程可增大VMFS-LFM信号和近参数多分量LFM信号的调频斜率在FrFT域的分辨率,使基于mTD-FrFT的参数估计方法可对VMFS-LFM信号和相近参数多分量LFM信号进行有效参数估计.