期刊文献+
共找到8,250篇文章
< 1 2 250 >
每页显示 20 50 100
A low-consumption multiple nuclides identification algorithm for portable gamma spectrometer
1
作者 Xi Huang Yong-Gang Yuan +3 位作者 Yu-Xuan Zhu Hua Chen Jin-Hui Qu Zhao-Yi Tan 《Nuclear Science and Techniques》 2025年第7期100-112,共13页
The multiple nuclides identification algorithm with low consumption and strong robustness is crucial for rapid radioactive source searching.This study investigates the design of a low-consumption multiple nuclides ide... The multiple nuclides identification algorithm with low consumption and strong robustness is crucial for rapid radioactive source searching.This study investigates the design of a low-consumption multiple nuclides identification algorithm for portable gamma spectrometers.First,the gamma spectra of 12 target nuclides(including the background case)were measured to create training datasets.The characteristic energies,obtained through energy calibration and full-energy peak addresses,are utilized as input features for a neural network.A large number of single-and multiple-nuclide training datasets are generated using random combinations and small-range drifting.Subsequently,a multi-label classification neural network based on a binary cross-entropy loss function is applied to export the existence probability of certain nuclides.The designed algorithm effectively reduces the computation time and storage space required by the neural network and has been successfully implemented in a portable gamma spectrometer with a running time of t_(r)<2 s.Results show that,in both validation and actual tests,the identification accuracy of the designed algorithm reaches 94.8%,for gamma spectra with a dose rate of d≈0.5μSv∕h and a measurement time t_(m)=60 s.This improves the ability to perform rapid on-site nuclide identification at important sites. 展开更多
关键词 Multiple nuclides identification Low consumption Portable gamma spectrometer Multi-label classification
在线阅读 下载PDF
Characterization of a prototype of the fast scintillator‑based neutron total cross‑section spectrometer on the Back‑n at CSNS
2
作者 Peng Luan Da‑Jun Zhao +11 位作者 Han Yi Wei Jiang Yi‑Wei Yang Pin‑Jing Cheng Jie‑Ming Xue Ji‑Rong Zhao Bao‑Qian Li Jing Liu Xiao‑Dong Wang Bo Zheng Wen Luo Song Feng 《Nuclear Science and Techniques》 2025年第10期159-168,共10页
The neutron total cross-section spectrometer(NTOX)applied on the Back-n beamline at the China Spallation Neutron Source(CSNS)is based on a multicell fission chamber and utilizes ^(235,238)U for neutron detection.To re... The neutron total cross-section spectrometer(NTOX)applied on the Back-n beamline at the China Spallation Neutron Source(CSNS)is based on a multicell fission chamber and utilizes ^(235,238)U for neutron detection.To reduce the experimental uncertainty in the resonance energy region of ^(235,238)U and improve the neutron detection efficiency,a fast scintillator-based neutron total cross-section(FAST)spectrometer was designed.A prototype based on a large-area square ^(6)Li-enriched Cs_(2)LiLaBr_(6)(CLLB)scintillator was constructed and beam-tested.The size of the CLLB scintillator was 50.8 mm×50.8 mm×6 mm,and its side was coupled to an array of 1×8 S14160 MPPC to avoid the irradiation from the high-intensity neutrons and rays.The beam test was performed using a broad-energy pulsed neutron and the time-of-flight(TOF)technique on the Back-n beamline.The results demonstrate that the prototype exhibits good neutron/ γ discrimination capability under strong flash irradiation.The prototype was applied to measure the neutron total cross-section of ^(nat)Pb and the result was compared with that obtained using the NTOX.The two results were consistent in the energy region of 0.3 eV to 1 keV,and the prototype showed a higher detection efficiency and did not exhibit fission resonance effect.This type of spectrometer can be used as a complement to the NTOX in the low-energy range and provides a technical reference and framework for developing the FAST spectrometer on the Back-n beamline. 展开更多
关键词 Neutron total cross-section FAST spectrometer Back-n white neutron beamline
在线阅读 下载PDF
Intrinsic detection efficiency and true coincidence summing correction for a low‑background γ spectrometer with a well‑type HPGe detector
3
作者 Ming‑Hao Zhu You‑Bao Wang +14 位作者 Qiang Wang Yu‑Qiang Zhang Jin‑Long Ma Zhi‑Wei Qin Jun Su Fu‑Qiang Cao Zhi‑Cheng Zhang Yu‑Wen Chen Jiang‑Lin Hou Chang‑Xin Guo Sheng‑Quan Yan Yun‑Ju Li Yang‑Ping Shen Bing Guo Wei‑Ping Liu 《Nuclear Science and Techniques》 2025年第10期115-122,共8页
A low-background γ spectrometer named the Gamma spectrometer for Nuclear Activation Studies(GNAS)was developed to detect scarce γ radioactivity,with a special focus on conducting activation experiments in nuclear as... A low-background γ spectrometer named the Gamma spectrometer for Nuclear Activation Studies(GNAS)was developed to detect scarce γ radioactivity,with a special focus on conducting activation experiments in nuclear astrophysics.It consisted of a well-type HPGe detector surrounded by optimized multi-layer shielding,which reduced the laboratory background counting rate by 99.5%and enabled a sensitivity edge as low as 0.044 Bq for the 477.6 KeV γ line of ^(7)Be.The near 4π geometry of the HPGe detector introduces a severe true coincidence summing(TCS)effect along with its high detection efficiency.To determine the intrinsic detection efficiency and correct for the TCS effect,a Monte Carlo simulation method was developed with the Geant4 toolkit.The detector model was optimized by matching the simulated full energy peak(FEP)statistics with those of a ^(137)Cs monoenergetic source and calibrated ^(55,57,58)Co sources produced by low-energy proton beam bombardment of natural iron.The intrinsic detection efficiency curve was obtained,and an algorithm for the correction of the TCS effect was programmed using decay data from the ENSDF library and Nuclear Wallet Cards.The GNAS fulfills the requirements of the ongoing activation measurement of proton-and alpha-induced reactions in nuclear astrophysics on the ground and at the Jinping Underground Nuclear Astrophysics(JUNA)facility. 展开更多
关键词 Low-backgroundγspectrometer GNAS Well-type HPGe detector True coincidence summing Activation measurement at JUNA
在线阅读 下载PDF
Correction:Data analysis framework for silicon strip detector in compact spectrometer for heavy-ion experiments
4
作者 Xiao-Bao Wei Yu-Hao Qin +15 位作者 Sheng Xiao Da-Wei Si Dong Guo Zhi Qin Fen-Hai Guan Xin-Yue Diao Bo-Yuan Zhang Bai-Ting Tian Jun-Huai Xu Tian-Ren Zhuo Yi-Bo Hao Zeng-Xiang Wang Shi-Tao Wang Chun-Wang Ma Yi-Jie Wang Zhi-Gang Xiao 《Nuclear Science and Techniques》 2025年第11期367-367,共1页
In section‘Track decoding’of this article,one of the paragraphs was inadvertently missed out after the text'…shows the flow diagram of the Tr2-1121 track mode.'The missed paragraph is provided below.
关键词 tr track mode flow diagram data analysis heavy ion experiments silicon strip detector compact spectrometer track decoding
在线阅读 下载PDF
A novel method for simultaneous measurement of^(222)Rn and^(220)Rn progeny concentrations measured by an alpha spectrometer
5
作者 Zhong-Kai Fan Jia-Le Sun +5 位作者 Hao-Xuan Li Xiang-Ming Cai Hui Yang Shou-Kang Qiu Yan-Liang Tan Jian Shan 《Nuclear Science and Techniques》 2025年第1期127-139,共13页
The accumulation of^(222)Rn and^(220)Rn progeny in poorly ventilated environments poses the risk of natural radiation exposure to the public.A previous study indicated that satisfactory results in determining the^(222... The accumulation of^(222)Rn and^(220)Rn progeny in poorly ventilated environments poses the risk of natural radiation exposure to the public.A previous study indicated that satisfactory results in determining the^(222)Rn and^(220)Rn progeny concentrations by measuring the total alpha counts at five time intervals within 560 min should be expected only in the case of high progeny concentrations in air.To complete the measurement within a relatively short period and adapt it for simultaneous measurements at comparatively lower^(222)Rn and^(220)Rn progeny concentrations,a novel mathematical model was proposed based on the radioactive decay law.This model employs a nonlinear fitting method to distinguish nuclides with overlapping spectra by utilizing the alpha particle counts of non-overlapping spectra within consecutive measurement cycles to obtain the concentrations of^(222)Rn and^(220)Rn progeny in air.Several verification experiments were conducted using an alpha spectrometer.The experimental results demonstrate that the concentrations of^(222)Rn and^(220)Rn progeny calculated by the new method align more closely with the actual circumstances than those calculated by the total count method,and their relative uncertainties are all within±16%.Furthermore,the measurement time was reduced to 90 min,representing an acceleration of 84%.The improved capability of the new method in distinguishing alpha particles with similar energies emitted from ^(218)Po and^(212)Bi,both approximately 6 MeV,contributed to realizing more accurate results.The proposed method has the potential advantage of measuring relatively low concentrations of^(222)Rn and^(220)Rn progeny in air more quickly via air filtration. 展开更多
关键词 ^(222)Rn ^(220)Rn Progeny concentration Nonlinear fitting method Alpha spectrometer
在线阅读 下载PDF
Phase error analysis and optimization for chirp transform spectrometer
6
作者 RU Penglei LIU Mengwei +1 位作者 HU Baifan WANG Wen 《Journal of Systems Engineering and Electronics》 2025年第3期597-608,共12页
In the field of deep space exploration,the rapid development of terahertz spectrometer has put forward higher requirements to the back-end chirp transform spectrometer(CTS)system.In order to simultaneously meet the me... In the field of deep space exploration,the rapid development of terahertz spectrometer has put forward higher requirements to the back-end chirp transform spectrometer(CTS)system.In order to simultaneously meet the measurement requirements of wide bandwidth and high accuracy spectral lines,we built a CTS system with an analysis bandwidth of 1 GHz and a frequency resolution of 100 kHz around the surface acoustic wave(SAW)chirp filter with a bandwidth of 1 GHz.In this paper,the relationship between the CTS nonlinear phase error shift model and the basic measurement parameters is studied,and the effect of CTS phase mismatch on the pulse compression waveform is analyzed by simulation.And the expander error optimization method is proposed for the problem that the large nonlinear error of the expander leads to the unbalanced response of the CTS system and the serious distortion of the compressed pulse waveform under large bandwidth.It is verified through simulation and experiment that the method is effective for reducing the root mean square error(RMSE)of the phase of the expander from 18.75°to 6.65°,reducing the in-band standard deviation of the CTS frequency resolution index from 8.43 kHz to 4.72 kHz,solving the problem of serious distortion of the compressed pulse waveform,and improving the uneven CTS response under large bandwidth. 展开更多
关键词 chirp transform spectrometer(CTS) microwave heterodyne spectroscopy phase error compensation surface acoustic wave(SAW) wide bandwidth
在线阅读 下载PDF
Separation of Ions from Volatile Organic Compounds Using High-Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometer 被引量:2
7
作者 李华 王晓浩 +2 位作者 唐飞 杨吉 丁力 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2010年第2期125-132,I0001,共9页
A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filte... A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filter for MS. The sample ions were created at ambient pressure by ion source, which was equipped with a 10.6 eV UV discharge lamp (A=116.5 nm). The drift tube of FAIMS is composed of two parallel planar electrodes and the dimension is 10 mm×8 mm×0.5 mm. FAIMS was investigated when driven by the high-filed rectangular asymmetric waveform with the peak-to-peak voltage of 1.36 kV at the frequency of 1 MHz and the duty cycle of 30%. The acetone, the butanone, and their mixture were adopted to characterize the FAIMS-MS. The mass spectra obtained from MS illustrate that there are ion-molecular reactions between the ions and the sample neutral molecular. And the proton transfer behavior in the mixture of the acetone and the butanone is also observed. With the compensation voltage tuned from -30 V to 10 V with a step size of 0.1 V, the ion pre-separation before MS is realized. 展开更多
关键词 High-field asymmetric waveform ion mobility spectrometry Mass spectrometer Ion-filter Ion-molecular reaction Proton transfer
在线阅读 下载PDF
Fourier Spectrometer based on Wide-range and Phase-locked Michelson Interferometer with Femtosecond Laser Excitation
8
作者 王自鑫 谢向生 +1 位作者 邓俊祺 周建英 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2010年第1期1-4,I0001,共5页
A wide-range and phase-locked Michelson interferometer technique is described. This technique combined with femtosecond laser is used to measure the spectrum of the rare-earth ion Nd:YVO4, which presents very high si... A wide-range and phase-locked Michelson interferometer technique is described. This technique combined with femtosecond laser is used to measure the spectrum of the rare-earth ion Nd:YVO4, which presents very high signal to noise ratio of interferometric intensity output and higher spectral resolution than traditional grating spectrophotometer. 展开更多
关键词 Wide-ranged and phase-locked Michelson interferometer Fourier spectrometer Femtosecond laser High signal to noise ratio High resolution
在线阅读 下载PDF
Characterization of Organic Aerosols in Beijing Using an Aerodyne High-Resolution Aerosol Mass Spectrometer 被引量:5
9
作者 ZHANG Junke WANG Yuesi +3 位作者 HUANG Xiaojuan LIU Zirui JI Dongsheng SUN Yang 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2015年第6期877-888,共12页
Fine particle of organic aerosol (OA), mostly arising from pollution, are abundant in Beijing. To achieve a better un- derstanding of the difference in OA in summer and autumn, a high-resolution time-of-flight aeros... Fine particle of organic aerosol (OA), mostly arising from pollution, are abundant in Beijing. To achieve a better un- derstanding of the difference in OA in summer and autumn, a high-resolution time-of-flight aerosol mass spectrometer (HR- ToF-AMS, Aerodyne Research Inc., USA) was deployed in urban Beijing in August and October 2012. The mean OA mass concentration in autumn was 30 4-30 μg m-3, which was higher than in summer (13 4-6.9 μg m-3). The elemental anal- ysis found that OA was more aged in summer (oxygen-to-carbon (O/C) ratios were 0.41 and 0.32 for summer and autumn, respectively). Positive matrix factorization (PMF) analysis identified three and five components in summer and autumn, re- spectively. In summer, an oxygenated OA (OOA), a cooking-emission-related OA (COA), and a hydrocarbon-like OA (HOA) were indentified. Meanwhile, the OOA was separated into LV-OOA (low-volatility OOA) and SV-OOA (semi-volatile OOA); and in autumn, a nitrogen-containing OA (NOA) was also found. The SOA (secondary OA) was always the most important OA component, accounting for 55% of the OA in the two seasons. Back trajectory clustering analysis found that the origin of the air masses was more complex in summer. Southerly air masses in both seasons were associated with the highest OA loading, while northerly air masses were associated with the lowest OA loading. A preliminary study of OA components, especially the POA (primary OA), in different periods found that the HOA and COA all decreased during the National Day holiday period, and HOA decreased at weekends compared with weekdays. 展开更多
关键词 organic aerosol aerosol mass spectrometer positive matrix factorization seasonal difference
在线阅读 下载PDF
A Satellite-borne Miniature Ion Mass Spectrometer for Space Plasma 被引量:3
10
作者 KONG Linggao ZHANG Aibing +7 位作者 ZHENG Xiangzhi AN Yaya WANG Wenjing TIAN Zhen GUAN Yibing LIU Chao DING Jianjing SUN Yueqiang 《空间科学学报》 CAS CSCD 北大核心 2015年第6期755-762,共8页
The miniature design technology is an important trend in space exploration.Mass spectrometer is used extensively in the space environment detection.The miniature ion mass spectrometer utilizes a 127° cylindrical ... The miniature design technology is an important trend in space exploration.Mass spectrometer is used extensively in the space environment detection.The miniature ion mass spectrometer utilizes a 127° cylindrical electrostatic analyzer accompanied with a Time of Flight(TOF)unit based on ultrathin carbon foil to measure the energy spectra and composition of space plasma.The Time of Flight technique has been used broadly in space plasma measurement.A new type of miniature method for the ion mass spectrometer is introduced.The total mass of the instrument is1.8 kg and the total power consumption is 2.0 W.The calibration results show that the energy measurement range is 8.71~43550eV,the energy resolution is 1.86%and the ion mass from 1 amu(1 amu= 1.67 × 10^(-27)kg) to 58 amu can be resolved by the miniature mass spectrometer.The miniature ion mass spectrometer also has a potential to be increased in the field of view by an electrostatic deflecting system to extend its application in space plasma detection.The miniature ion mass spectrometer has been selected for pre-study of Chinese Strategic Priority Research Program on Space Science. 展开更多
关键词 Satellite-borne MINIATURE MASS spectrometer Space
在线阅读 下载PDF
Correction and verification of HL-2A Tokamak Bonner sphere spectrometer in monoenergetic neutron fields from 100 keV to 5 MeV 被引量:3
11
作者 Bo-Wen Zheng Chun-Yu Jiang +4 位作者 Zi-Hao Liu Yin-Hai Pan Xian-Ying Song Shi-Biao Tang Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第11期72-82,共11页
A real-time Bonner sphere spectrometer(BSS)has been developed for spectral neutron measurements with the HL-2A Tokamak.To correct and verify the accuracy of the neutron spectrum from the BSS,the BSS system was calibra... A real-time Bonner sphere spectrometer(BSS)has been developed for spectral neutron measurements with the HL-2A Tokamak.To correct and verify the accuracy of the neutron spectrum from the BSS,the BSS system was calibrated using monoenergetic neutron beams in the energy range of 100 keV–5 MeV.The response function of the BSS was corrected based on the calibration results,and the corrected BSS system was verified by unfolding monoenergetic neutron spectra.Fusion neutron spectra on the HL-2A have been obtained from the calibrated BSS system for the first time. 展开更多
关键词 Bonner SPHERE spectrometer Calibration Response function NEUTRON spectrometRY
在线阅读 下载PDF
Automatic ^(40)Ar/^(39)Ar Dating Techniques Using Multicollector ARGUS VI Noble Gas Mass Spectrometer with Self-Made Peripheral Apparatus 被引量:12
12
作者 Xiu-Juan Bai Hua-Ning Qiu +1 位作者 Wen-Gui Liu Lian-Fu Mei 《Journal of Earth Science》 SCIE CAS CSCD 2018年第2期408-415,共8页
A new fully automatic ^40Ar/^39Ar laboratory with a Thermo Scientific ARGUS VI mass spectrometer has been established in China University of Geosciences (Wuhan). We designed and developed a mini efficient preparatio... A new fully automatic ^40Ar/^39Ar laboratory with a Thermo Scientific ARGUS VI mass spectrometer has been established in China University of Geosciences (Wuhan). We designed and developed a mini efficient preparation system (80 mL), a CO2 laser for heating samples, a crusher for extracting fluid inclusions within K-poor minerals and an air reservoir (31 L) and pipette (0.1 mL) system. The ARGUS VI mass spectrometer is operated by the Qtegra Noble Gas software, which can control the peripheral accessories, such as pneumatic valves, CO2 laser and crusher through a PeriCon (peripheral controller). The experimental procedures of atmospheric argon ana- lyses, ^40Ar/^39Ar dating by laser stepwise heating and by progressive crushing in vacuo, can be fully automatically performed. The weighted mean of atmospheric ^40Ar/^36Ar ratios is 302.22+0.03 (1σ, MSWD=0.74, n=200), indicating that air reservoir and pipette system and the whole instrument sys- tem are very stable. This laboratory is a successful pioneer example in China to establish a new no- ble gas laboratory with self-made peripheral accessories expect for the mass spectrometer. 展开更多
关键词 ^40Ar/^39Ar dating fully automatic CO2 laser ARGUS VI mass spectrometer Qtegra noble gas software.
原文传递
Factors Influencing the Electron Yield of Needle-Ring Pulsed Corona Discharge Electron Source for Negative Ion Mobility Spectrometer 被引量:4
13
作者 刘欣 李胜利 李铭书 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第12期1215-1220,共6页
A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron... A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron source. Simulation with Ansoft Maxwell 12 is carried out to analyze the electric field distribution within the IMS, and to offer the basis and foundation for analyzing the measurement results. The measurement results of the quantities of electrons show that when the drift electric field strength and the ring inner diameter rise, both the number of ef- fective electrons and the effective electron rate are increased. When the discharge voltage becomes stronger, the number of effective electrons goes up while the effective electron rate goes down. In light of the simulation results, mechanisms underlying the effects of drift electric field strength, ring inner diameter, and discharge voltage on the effective electron number and effective electron rate are discussed. These will make great sense for designing negative ion mode IMS using the needle-ring pulsed corona discharge as the electron source. 展开更多
关键词 ion mobility spectrometer electron source pulsed corona discharge effectiveelectrons simulation
在线阅读 下载PDF
Development of the real-time double-ring fusion neutron time-of-flight spectrometer system at HL-2M 被引量:3
14
作者 Bo-Wen Zheng Wei Zhang +5 位作者 Tong-Yu Wu Si-Cheng Huang Yi-Po Zhang Xiu-Feng Xu Shi-Biao Tang Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第12期22-30,共9页
A real-time double-ring neutron time-of-flight(TOFII) spectrometer system has been proposed to achieve plasma diagnosis on HL-2M tokamak with a relatively high count rate and sufficient energy resolution.The TOFII sys... A real-time double-ring neutron time-of-flight(TOFII) spectrometer system has been proposed to achieve plasma diagnosis on HL-2M tokamak with a relatively high count rate and sufficient energy resolution.The TOFII system is in its development stage,and this work describes its characteristics in terms of design principle,system structure,electronic system design,preliminary tests,and neutron transport simulation.The preliminary test results illustrate that the TOFII system can demonstrate the realtime dynamic spectrum every 10 ms.The results also show that based on the support vector machine method,the n-γ discrimination algorithm achieves the discrimination accuracy of 99.1%with a figure of merit of 1.30,and the intrinsic timing resolution of the system is within 0.3%.The simulated flight time spectrums from 1 to 5 MeV are obtained through the Monte Carlo tool Geant4,which also provide the reasonable results.The TOFII system will then be calibrated on mono-energetic neutron sources for further verification. 展开更多
关键词 Time-of-light NEUTRON spectrometer GEANT4 HL-2M
在线阅读 下载PDF
Recent developments of miniature ion trap mass spectrometers 被引量:7
15
作者 Qi Guo Lijuan Gao +1 位作者 Yanbing Zhai Wei Xu 《Chinese Chemical Letters》 SCIE CAS CSCD 2018年第11期1578-1584,共7页
With outstanding analytical performance and portability, miniature mass spectrometer is one of the most powerful tools for in-situ analysis. The miniaturization of mass spectrometers has lasted for more than ten years... With outstanding analytical performance and portability, miniature mass spectrometer is one of the most powerful tools for in-situ analysis. The miniaturization of mass spectrometers has lasted for more than ten years, during which a number of miniature mass spectrometers employing different techniques have been developed. Small-in-size, working at relatively high pressure region and capable of performing tandem mass spectrometry, ion trap is the most widely used mass analyzer in miniature mass spectrometer systems. The recent development of miniature ion trap mass spectrometer systems in the last ten years was reviewed in this paper. These instruments adopt different atmospheric pressure interfaces (APIs), which are membrane inlets (MIs), discontinuous atmospheric pressure interface (DAPI) and continuous atmospheric pressure interface (CAPI). This review emphasizes on the mini mass spectrometry (MS) system that can be handheld by one person, but not the field-able ones that are too large to be hand-portable. 展开更多
关键词 Miniature mass spectrometer lon trap Membrane inlet Discontinuous atmospheric pressure interface Continuous atmospheric pressure interface
原文传递
Methods for obtaining characteristic γ-ray net peak count from interlaced overlap peak in HPGe γ-ray spectrometer system 被引量:3
16
作者 Yue-Li Song Feng-Qun Zhou +2 位作者 Yong Li Xiao-Jun Sun Peng-Fei Ji 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第1期73-78,共6页
For a characteristic c-ray with interlaced overlap peak, and the case where its reliable and credible net count cannot be obtained using the current high-purity germanium(HPGe) multichannel γ-ray spectrum software, t... For a characteristic c-ray with interlaced overlap peak, and the case where its reliable and credible net count cannot be obtained using the current high-purity germanium(HPGe) multichannel γ-ray spectrum software, two new methods are proposed herein to obtain the γ-ray net peak count from the interlaced overlap peak in the HPGe cray spectrometer system, of which one is the symmetric conversion method based on Gaussian distribution and the other is where the energy average value of two close γ-rays is regarded as the γ-ray energy. The experimental results indicate that the two methods mentioned above are reliable and credible. This study is significant for the development of better γ-ray spectrum processing software for measuring complex γ-ray spectra concerning the nuclear reaction cross section, neutron activation analysis, and analysis of transuranium elements, using an HPGe detector. 展开更多
关键词 PEAK COUNT Interlaced OVERLAP PEAK Highpurity germanium (HPGe)γ-ray spectrometer system
在线阅读 下载PDF
A real-time neutron-gamma discriminator based on the support vector machine method for the time-of-flight neutron spectrometer 被引量:3
17
作者 张伟 吴彤宇 +3 位作者 郑博文 李世平 张轶泼 阴泽杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第4期170-175,共6页
A new neutron-gamma discriminator based on the support vector machine(SVM) method is proposed to improve the performance of the time-of-flight neutron spectrometer. The neutron detector is an EJ-299-33 plastic scintil... A new neutron-gamma discriminator based on the support vector machine(SVM) method is proposed to improve the performance of the time-of-flight neutron spectrometer. The neutron detector is an EJ-299-33 plastic scintillator with pulse-shape discrimination(PSD) property. The SVM algorithm is implemented in field programmable gate array(FPGA) to carry out the real-time sifting of neutrons in neutron-gamma mixed radiation fields. This study compares the ability of the pulse gradient analysis method and the SVM method. The results show that this SVM discriminator can provide a better discrimination accuracy of 99.1%. The accuracy and performance of the SVM discriminator based on FPGA have been evaluated in the experiments. It can get a figure of merit of 1.30. 展开更多
关键词 plasma diagnosis support vector machine pulse-shape discrimination TOF spectrometer
在线阅读 下载PDF
Early detection of pine wilt disease in Pinus tabuliformis in North China using a field portable spectrometer and UAV-based hyperspectral imagery 被引量:15
18
作者 Run Yu Lili Ren Youqing Luo 《Forest Ecosystems》 SCIE CSCD 2021年第3期583-601,共19页
Background:Pine wilt disease(PWD)is a major ecological concern in China that has caused severe damage to millions of Chinese pines(Pinus tabulaeformis).To control the spread of PWD,it is necessary to develop an effect... Background:Pine wilt disease(PWD)is a major ecological concern in China that has caused severe damage to millions of Chinese pines(Pinus tabulaeformis).To control the spread of PWD,it is necessary to develop an effective approach to detect its presence in the early stage of infection.One potential solution is the use of Unmanned Airborne Vehicle(UAV)based hyperspectral images(HIs).UAV-based HIs have high spatial and spectral resolution and can gather data rapidly,potentially enabling the effective monitoring of large forests.Despite this,few studies examine the feasibility of HI data use in assessing the stage and severity of PWD infection in Chinese pine.Method:To fill this gap,we used a Random Forest(RF)algorithm to estimate the stage of PWD infection of trees sampled using UAV-based HI data and ground-based data(data directly collected from trees in the field).We compared relative accuracy of each of these data collection methods.We built our RF model using vegetation indices(VIs),red edge parameters(REPs),moisture indices(MIs),and their combination.Results:We report several key results.For ground data,the model that combined all parameters(OA:80.17%,Kappa:0.73)performed better than VIs(OA:75.21%,Kappa:0.66),REPs(OA:79.34%,Kappa:0.67),and MIs(OA:74.38%,Kappa:0.65)in predicting the PWD stage of individual pine tree infection.REPs had the highest accuracy(OA:80.33%,Kappa:0.58)in distinguishing trees at the early stage of PWD from healthy trees.UAV-based HI data yielded similar results:the model combined VIs,REPs and MIs(OA:74.38%,Kappa:0.66)exhibited the highest accuracy in estimating the PWD stage of sampled trees,and REPs performed best in distinguishing healthy trees from trees at early stage of PWD(OA:71.67%,Kappa:0.40).Conclusion:Overall,our results confirm the validity of using HI data to identify pine trees infected with PWD in its early stage,although its accuracy must be improved before widespread use is practical.We also show UAV-based data PWD classifications are less accurate but comparable to those of ground-based data.We believe that these results can be used to improve preventative measures in the control of PWD. 展开更多
关键词 Pine wilt disease Remote sensing spectrometer Hyperspectral imaging Random forest Classification
在线阅读 下载PDF
The nonlinearity measurement of charge-coupled device array spectrometer using colorful LED 被引量:2
19
作者 赵伟强 刘慧 刘建 《Optoelectronics Letters》 EI 2017年第6期436-438,共3页
A nonlinearity measurement of the charge-coupled device(CCD) array spectrometer using flux addition and comparison method is described. The light with various colors from the colorful light emitting diode(LED) light s... A nonlinearity measurement of the charge-coupled device(CCD) array spectrometer using flux addition and comparison method is described. The light with various colors from the colorful light emitting diode(LED) light source is applied to measure the nonlinearity of the spectrometer at different wavelengths, respectively. An high-end CCD array spectrometer is tested. For colorful LED light sources, the nonlinearity factors of the CCD array spectrometer(absolute value) are as follows: k<0.8% for white light, k <1.1% for red light, k <2.2% for green light and k<4.7% for blue light. By using those quasi-monochromatic light sources, it is shown that the nonlinearity depends on the wavelength. It is important to be wariness about the spectral nonlinearity and related uncertainty evaluation when the narrow-band light source is tested. 展开更多
关键词 spectrometer COLORFUL NONLINEARITY ABSOLUTE COLORS PHOTODETECTOR correction normalized uncertainty integrating
原文传递
Modeling and analysis for the image mapping spectrometer 被引量:1
20
作者 袁艳 丁晓铭 +1 位作者 苏丽娟 王婉悦 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第4期144-155,共12页
The snapshot image mapping spectrometer(IMS) has advantages such as high temporal resolution,high throughput,compact structure and simple reconstructed algorithm.In recent years,it has been utilized in biomedicine,r... The snapshot image mapping spectrometer(IMS) has advantages such as high temporal resolution,high throughput,compact structure and simple reconstructed algorithm.In recent years,it has been utilized in biomedicine,remote sensing,etc.However,the system errors and various factors can cause cross talk,image degradation and spectral distortion in the system.In this research,a theoretical model is presented along with the point response function(PRF) for the IMS,and the influence of the mirror tilt angle error of the image mapper and the prism apex angle error are analyzed based on the model.The results indicate that the tilt angle error causes loss of light throughput and the prism apex angle error causes spectral mixing between adjacent sub-images.The light intensity on the image plane is reduced to 95%when the mirror tilt angle error is increased to ±100 "(≈ 0.028°).The prism apex error should be controlled within the range of 0-36"(0.01°)to ensure the designed number of spectral bands,and avoid spectral mixing between adjacent images. 展开更多
关键词 imaging spectrometers snapshot imaging spectrometer imaging model image mapper
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部