Temperature and humidity are two important factors that influence both indoor thermal comfort and air quality.Through varying compressor and supply fan speeds of a direct expansion(DX)air conditioning(A/C)unit,the air...Temperature and humidity are two important factors that influence both indoor thermal comfort and air quality.Through varying compressor and supply fan speeds of a direct expansion(DX)air conditioning(A/C)unit,the air temperature and humidity in the conditioned space can be regulated simultaneously.However,most existing controllers are designed to minimize the tracking errors between the system outputs with their corresponding settings as quickly as possible.The energy consumption,which is directly influenced by the compressor and supply fan speeds,is not considered in the relevant controller formulations,and thus the system may not operate with the highest possible energy efficiency.To effectively control temperature and humidity while minimizing the system energy consumption,a model predictive control(MPC)strategy was developed for a DX A/C system,and the development results are presented in this paper.A physically-based dynamic model for the DX A/C system with both sensible and latent heat transfers being considered was established and validated by experiments.To facilitate the design of MPC,the physical model was further linearized.The MPC scheme was then developed by formulating the objective function which sought to minimize the tracking errors of temperature and moisture content while saving energy consumption.Based on the results of command following and disturbance rejection tests,the proposed MPC scheme was capable of controlling temperature and humidity with adequate control accuracy and sensitivity.In comparison to linear-quadratic-Gaussian(LQG)controller,better control accuracy and lower energy consumption could be realized when using the proposed MPC strategy to simultaneously control temperature and humidity.展开更多
The purpose of this research is to reveal the exergy variation of each component in a direct-expansion solar-assisted heat pump(DX-SAHP)system.Exergy analysis of the DX-SAHP system with R134a is conducted.and the perf...The purpose of this research is to reveal the exergy variation of each component in a direct-expansion solar-assisted heat pump(DX-SAHP)system.Exergy analysis of the DX-SAHP system with R134a is conducted.and the performance evaluation is done.The proposed system is mainly composed of a bare plate solar collec-tor/evaporator,a hermetic variable-frequency rotary-type compressor,a micro-channel condenser and an electronic expansion valve.The experimental data include the exergy loss rates.irreversibility rates and exergy loss ratios of all components and the infuences of ambient temperature on these parameters.The analysis results show that the average irreversibility rate of the compressor is 204.8 W at an ambient temperature of 16℃,and 149.9 W atan ambient temperature of 27℃.The highest irreversibility rate occurs in the compression process,followed by the throttling process.the evaporation process and the condensation process.展开更多
The change of impervious surface area(ISA) can effectively reveal the gradual process of urbanization and act as a key index for monitoring urban expansion. Experiencing rapid growth of the built environment in the 20...The change of impervious surface area(ISA) can effectively reveal the gradual process of urbanization and act as a key index for monitoring urban expansion. Experiencing rapid growth of the built environment in the 2000 s, urban expansion of Beijing has not been fully characterized through ISA. In this study, Landsat TM images of Beijing in 2001 and 2009 were obtained, and the eight-year urban expansion process in Beijing was analyzed using the ISA extracted by means of the vegetation-imperious surface-soil(V-I-S) model. From the spatial variation in ISA, the ring structure of urban expansion in Beijing was significant during the study period, with decreasing urban density from the city center to the periphery. In the ring road analysis, the most dramatic changes of ISA were found between the fifth ring and the sixth ring. This area has experienced the most new residential development, and is currently the main source of urban expansion. The typical profile lines revealed the directional characteristics of urban expansion. The east-west profile was the most urbanized axes in Beijing, while ISA change in the east-north profile was more significant than in the other five profiles. Moreover, the transition matrix of ISA levels revealed an increase in urban density in the low density built areas; the Moran′s I index showed a clear expansion of the central urban area, which spread contiguously; and the standard deviational ellipse indicated the northeast was the dominant direction of urban expansion. These findings can provide important spatial control guidelines in the next round of national economic and social development planning, overall urban and rural planning, and land use planning.展开更多
The paper presents a general distributed model of a vertical U-tube direct expansion heat exchanger coupled with the ground. This model is developed for studying the dynamic thermal behavior of a buried heat exchanger...The paper presents a general distributed model of a vertical U-tube direct expansion heat exchanger coupled with the ground. This model is developed for studying the dynamic thermal behavior of a buried heat exchanger which is an integral part of a so-called direct expansion heat pump. The transient conservative equations of mass, momentum and energy considering single and two-phase flow of refrigerant are derived and presented. The diffusive heat exchange with the ground is treated using an analytical approach to treat short-time scale response of vertical boreholes based on an imposed temperature. The thermal interference between the two pipes of the heat exchanger is also considered. The mathematical equations of the model are numerically presented using a control volume formulation and the solution of the system of equations is obtained by successive iterations. The dynamic behavior of the evaporator is simulated and the numerical results are analyzed regarding spatial parameters distribution and thermal interference influence.展开更多
High speed data communication between digital signal processor and the host is required to meet the demand of most real-time systems. PCI bus technology is a solution of this problem. The principle of data communicati...High speed data communication between digital signal processor and the host is required to meet the demand of most real-time systems. PCI bus technology is a solution of this problem. The principle of data communication based on PCI has been explained. Meanwhile, the technology of data transfer between synchronous dynamic RAM(SDRAM) and an mapping space of on-chip memory(L2) by expansion direct memory access(EDMA) has also been realized.展开更多
基金supports for the Science and Technology Project of Zhejiang Province(No.LGG21F030009)the Natural Science Foundation of Zhejiang Province(No.LY20F030010)the Key R&D Projects in Zhejiang Province(No.2020C01164)are gratefully acknowledged.
文摘Temperature and humidity are two important factors that influence both indoor thermal comfort and air quality.Through varying compressor and supply fan speeds of a direct expansion(DX)air conditioning(A/C)unit,the air temperature and humidity in the conditioned space can be regulated simultaneously.However,most existing controllers are designed to minimize the tracking errors between the system outputs with their corresponding settings as quickly as possible.The energy consumption,which is directly influenced by the compressor and supply fan speeds,is not considered in the relevant controller formulations,and thus the system may not operate with the highest possible energy efficiency.To effectively control temperature and humidity while minimizing the system energy consumption,a model predictive control(MPC)strategy was developed for a DX A/C system,and the development results are presented in this paper.A physically-based dynamic model for the DX A/C system with both sensible and latent heat transfers being considered was established and validated by experiments.To facilitate the design of MPC,the physical model was further linearized.The MPC scheme was then developed by formulating the objective function which sought to minimize the tracking errors of temperature and moisture content while saving energy consumption.Based on the results of command following and disturbance rejection tests,the proposed MPC scheme was capable of controlling temperature and humidity with adequate control accuracy and sensitivity.In comparison to linear-quadratic-Gaussian(LQG)controller,better control accuracy and lower energy consumption could be realized when using the proposed MPC strategy to simultaneously control temperature and humidity.
基金the National Natural Science Foundation of China(No.51776115)the Shandong Province Graduate Student Supervisor Guidance Ability Promotion Program(No.SDYY17037)the Shandong University of Science and Technology Graduate Student Supervisor Guidance Ability Promotion Program(No.KDYC17009)。
文摘The purpose of this research is to reveal the exergy variation of each component in a direct-expansion solar-assisted heat pump(DX-SAHP)system.Exergy analysis of the DX-SAHP system with R134a is conducted.and the performance evaluation is done.The proposed system is mainly composed of a bare plate solar collec-tor/evaporator,a hermetic variable-frequency rotary-type compressor,a micro-channel condenser and an electronic expansion valve.The experimental data include the exergy loss rates.irreversibility rates and exergy loss ratios of all components and the infuences of ambient temperature on these parameters.The analysis results show that the average irreversibility rate of the compressor is 204.8 W at an ambient temperature of 16℃,and 149.9 W atan ambient temperature of 27℃.The highest irreversibility rate occurs in the compression process,followed by the throttling process.the evaporation process and the condensation process.
基金Under the auspices of Key Project of National Natural Science Foundation of China(No.41130534)
文摘The change of impervious surface area(ISA) can effectively reveal the gradual process of urbanization and act as a key index for monitoring urban expansion. Experiencing rapid growth of the built environment in the 2000 s, urban expansion of Beijing has not been fully characterized through ISA. In this study, Landsat TM images of Beijing in 2001 and 2009 were obtained, and the eight-year urban expansion process in Beijing was analyzed using the ISA extracted by means of the vegetation-imperious surface-soil(V-I-S) model. From the spatial variation in ISA, the ring structure of urban expansion in Beijing was significant during the study period, with decreasing urban density from the city center to the periphery. In the ring road analysis, the most dramatic changes of ISA were found between the fifth ring and the sixth ring. This area has experienced the most new residential development, and is currently the main source of urban expansion. The typical profile lines revealed the directional characteristics of urban expansion. The east-west profile was the most urbanized axes in Beijing, while ISA change in the east-north profile was more significant than in the other five profiles. Moreover, the transition matrix of ISA levels revealed an increase in urban density in the low density built areas; the Moran′s I index showed a clear expansion of the central urban area, which spread contiguously; and the standard deviational ellipse indicated the northeast was the dominant direction of urban expansion. These findings can provide important spatial control guidelines in the next round of national economic and social development planning, overall urban and rural planning, and land use planning.
文摘The paper presents a general distributed model of a vertical U-tube direct expansion heat exchanger coupled with the ground. This model is developed for studying the dynamic thermal behavior of a buried heat exchanger which is an integral part of a so-called direct expansion heat pump. The transient conservative equations of mass, momentum and energy considering single and two-phase flow of refrigerant are derived and presented. The diffusive heat exchange with the ground is treated using an analytical approach to treat short-time scale response of vertical boreholes based on an imposed temperature. The thermal interference between the two pipes of the heat exchanger is also considered. The mathematical equations of the model are numerically presented using a control volume formulation and the solution of the system of equations is obtained by successive iterations. The dynamic behavior of the evaporator is simulated and the numerical results are analyzed regarding spatial parameters distribution and thermal interference influence.
文摘High speed data communication between digital signal processor and the host is required to meet the demand of most real-time systems. PCI bus technology is a solution of this problem. The principle of data communication based on PCI has been explained. Meanwhile, the technology of data transfer between synchronous dynamic RAM(SDRAM) and an mapping space of on-chip memory(L2) by expansion direct memory access(EDMA) has also been realized.