The sub-forum on standardization of new energy and direct-current diversified applications was held on July 9,which gathered leaders and experts to discuss how to thoroughly implement the national green power direct c...The sub-forum on standardization of new energy and direct-current diversified applications was held on July 9,which gathered leaders and experts to discuss how to thoroughly implement the national green power direct connection policy proposed in the transformation of the energy landscape,pool wisdom to tackle bottlenecks in the industrialization of DC technology,and leverage the role of standardization in coordinating and regulating the diversified applications of DC technology.It was designed to promote the establishment of a collaborative,open,and advanced global standards system for DC technology.展开更多
DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researche...DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researched. The AC-DC interconnected large-scale system model under the monopole operation mode was established. The earth surface potential and DC current distribution in various stations under the different surface thickness was calculated. Some useful conclusions are drawn from the analyzed results.展开更多
This paper focus on the Modeling and Calculation of DC current distribution in AC power grid induced under HVDC Ground-Return-Mode. Applying complex image method and boundary element method, a new field-circuit coupli...This paper focus on the Modeling and Calculation of DC current distribution in AC power grid induced under HVDC Ground-Return-Mode. Applying complex image method and boundary element method, a new field-circuit coupling model was set up. Based on the calculation result with complex image method, this paper derived the modification factor for induced earth potential from practical measurement, which increased the accuracy of calculation. The modification method is helpful for evaluation on the effect of means used for blocking the dc-bias current in transformer neutral and also useful for the forecast of the DC current distribution when the power grid is in different line connection mode. The DC distribution character in Guangdong power grid is shown and suggestion is proposed that the mitigation of dc-bias should start from those substations whose earth-potential is highest.展开更多
在海上风电直流汇集-直流送出系统中,基于单相模块化多电平换流器的面对面型(modular multilevel converter based front-to-front,MMC-FTF)高压大功率DC/DC变换器是连接中压汇聚线与高压直流输电(high voltage direct current,HVDC)线...在海上风电直流汇集-直流送出系统中,基于单相模块化多电平换流器的面对面型(modular multilevel converter based front-to-front,MMC-FTF)高压大功率DC/DC变换器是连接中压汇聚线与高压直流输电(high voltage direct current,HVDC)线路的关键接口设备。然而,针对MMC-FTF变换器的阻抗建模鲜有报道,且含MMC-FTF变换器的HVDC系统的小信号稳定性问题尚不明确。针对此问题,该文首先根据频率耦合效应提出共差模提取矩阵,实现了多谐波线性化方法下单相及三相MMC交直流侧阻抗模型的统一,并建立了MMC-FTF变换器的直流侧阻抗模型。其次,利用阻抗稳定性判据揭示了MMC-FTF变换器与岸上三相MMC换流站互联时存在的振荡风险。接着,根据相角灵敏度指标定量评估了不同控制器参数对系统稳定性的影响,并提出用于提升系统稳定性的调参准则。最后,基于MATLAB/Simulink仿真和硬件在环实验验证了结果的正确性。展开更多
The experiments of large consumers direct power trading is conducting in china nationwide, and it’s important to the reform of electricity market. To compensated efficiencies in security correction of large consumers...The experiments of large consumers direct power trading is conducting in china nationwide, and it’s important to the reform of electricity market. To compensated efficiencies in security correction of large consumers direct power trading, a novel security correction method based on DC power transfer distribution factor was proposed. Using the presented method to comply security correction, all the transactions that satisfy the specific requirements of maximizing social welfare are able to enter security correction process, and when the power of transmission line is out of limit, this method avoid the transaction which causes this problem is abandoned directly by introducing supplement transactions. The simulation has shown that the proposed security correction method of large consumers direct power trading based on DC power transfer distribution factor is effective.展开更多
Detecting, real-time monitoring and early warning of underground water-bearing structures are critically important issues in prevention and mitigation of water inrush hazards in underground engineering. Direct current...Detecting, real-time monitoring and early warning of underground water-bearing structures are critically important issues in prevention and mitigation of water inrush hazards in underground engineering. Direct current (DC) resistivity method is a widely used method for routine detection, advanced detection and real-time monitoring of water-bearing structures, due to its high sensitivity to groundwater. In this study, the DC resistivity method applied to underground engineering is reviewed and discussed, including the observation mode, multiple inversions, and real-time monitoring. It is shown that a priori information constrained inversion is desirable to reduce the non-uniqueness of inversion, with which the accuracy of detection can be significantly improved. The focused resistivity method is prospective for advanced detection;with this method, the flanking interference can be reduced and the detection dis-tance is increased subsequently. The time-lapse resistivity inversion method is suitable for the regions with continuous conductivity changes, and it can be used to monitor water inrush in those regions. Based on above-mentioned features of various methods in terms of benefits and limitations, we propose a three-dimensional (3D) induced polarization method characterized with multi-electrode array, and introduce it into tunnels and mines combining with real-time monitoring with time-lapse inversion and cross-hole resistivity method. At last, the prospective applications of DC resistivity method are discussed as follows: (1) available advanced detection technology and instrument in tunnel excavated by tunnel boring machine (TBM), (2) high-resolution detection method in holes, (3) four-dimensional (4D) monitoring technology for water inrush sources, and (4) estimation of water volume in water-bearing structures.展开更多
Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC g...Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.展开更多
DC series-parallel power flow controller(SP-PFC)is a highly efficient device to solve the problem of uncontrolled line current in the bipolar DC distribution system.However,its potential in fault current limiting is n...DC series-parallel power flow controller(SP-PFC)is a highly efficient device to solve the problem of uncontrolled line current in the bipolar DC distribution system.However,its potential in fault current limiting is not fully explored.In this paper,a self-adaptive action strategy(SAAS)and a parameter optimization method of SP-PFC in bipolar DC distribution systems are proposed.Firstly,the common-and different-mode(CDM)equivalent circuits of the bipolar DC distribution system with SP-PFC in different fault stages are established,which avoids the line coupling inductance.Based on this,the influence of different parameters and line coupling inductance on the fault current limiting capability are investigated.It is found that the SP-PFC has the best fault current limiting capability when the capacitance and inductance of filter are inversely proportional.To realize the adaptability of fault current limiting capability under different fault severities,the SAAS of SP-PFC is proposed.The validity of the CDM equivalent circuits and parameter optimization method,and the effectiveness of the SAAS are verified by simulations and experiments.展开更多
The perturbation method is used to study the localization of electric field distribution and the effective nonlinear response of graded composites under an external alternating-current(AC) and direct-current(DC) e...The perturbation method is used to study the localization of electric field distribution and the effective nonlinear response of graded composites under an external alternating-current(AC) and direct-current(DC) electric field E app = E 0(1 + sin ωt).The dielectric profile of the cylindrical inclusions is modeled by function ε i(r) = C k r k(r ≤ a),where r is the radius of the cylindrical inclusion,and C k,k,a are parameters.In the dilute limit,the local potentials and the effective nonlinear responses at all harmonics are derived.Meanwhile,the general effective nonlinear responses are also derived and compared with the effective nonlinear responses at harmonics under the AC and DC external field.It is found that the effective nonlinear AC and DC responses at harmonics can be calculated by those of the general effective nonlinear of the graded composites under the external DC electric field.Moreover,the obtained local electrical fields show that the electrical field distribution in the cylindrical inclusions is controllable,and the maximum of the electric field inside the cylinder is at its center.展开更多
Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC cur...Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC current limiter and improve the fault current suppression capability, the fault current suppression mechanism of the DC power distribution system is revealed based on the circuit model. Then, based on the mathematical model of the DC breaker, the characteristic parameters of DC breaking are extracted, and then the influence of different characteristic parameters on the breaking characteristics of fault current is studied. Finally, the mathematical model of the collaborative process between DC circuit breaker and DC current limiter is established. The charac-teristic parameters of fault current collaborative suppression are extracted. The coupling effects of different characteristic parameters on the fault current col-laborative suppression are studied. The principle of collaborative configuration of DC circuit breaker and DC current limiter is proposed, and the collaborative suppression ability of DC circuit breaker and DC current limiter to fault current is fully exploited to ensure the safe and reliable operation of the DC power distribution system.展开更多
文摘The sub-forum on standardization of new energy and direct-current diversified applications was held on July 9,which gathered leaders and experts to discuss how to thoroughly implement the national green power direct connection policy proposed in the transformation of the energy landscape,pool wisdom to tackle bottlenecks in the industrialization of DC technology,and leverage the role of standardization in coordinating and regulating the diversified applications of DC technology.It was designed to promote the establishment of a collaborative,open,and advanced global standards system for DC technology.
文摘DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researched. The AC-DC interconnected large-scale system model under the monopole operation mode was established. The earth surface potential and DC current distribution in various stations under the different surface thickness was calculated. Some useful conclusions are drawn from the analyzed results.
文摘This paper focus on the Modeling and Calculation of DC current distribution in AC power grid induced under HVDC Ground-Return-Mode. Applying complex image method and boundary element method, a new field-circuit coupling model was set up. Based on the calculation result with complex image method, this paper derived the modification factor for induced earth potential from practical measurement, which increased the accuracy of calculation. The modification method is helpful for evaluation on the effect of means used for blocking the dc-bias current in transformer neutral and also useful for the forecast of the DC current distribution when the power grid is in different line connection mode. The DC distribution character in Guangdong power grid is shown and suggestion is proposed that the mitigation of dc-bias should start from those substations whose earth-potential is highest.
文摘在海上风电直流汇集-直流送出系统中,基于单相模块化多电平换流器的面对面型(modular multilevel converter based front-to-front,MMC-FTF)高压大功率DC/DC变换器是连接中压汇聚线与高压直流输电(high voltage direct current,HVDC)线路的关键接口设备。然而,针对MMC-FTF变换器的阻抗建模鲜有报道,且含MMC-FTF变换器的HVDC系统的小信号稳定性问题尚不明确。针对此问题,该文首先根据频率耦合效应提出共差模提取矩阵,实现了多谐波线性化方法下单相及三相MMC交直流侧阻抗模型的统一,并建立了MMC-FTF变换器的直流侧阻抗模型。其次,利用阻抗稳定性判据揭示了MMC-FTF变换器与岸上三相MMC换流站互联时存在的振荡风险。接着,根据相角灵敏度指标定量评估了不同控制器参数对系统稳定性的影响,并提出用于提升系统稳定性的调参准则。最后,基于MATLAB/Simulink仿真和硬件在环实验验证了结果的正确性。
文摘The experiments of large consumers direct power trading is conducting in china nationwide, and it’s important to the reform of electricity market. To compensated efficiencies in security correction of large consumers direct power trading, a novel security correction method based on DC power transfer distribution factor was proposed. Using the presented method to comply security correction, all the transactions that satisfy the specific requirements of maximizing social welfare are able to enter security correction process, and when the power of transmission line is out of limit, this method avoid the transaction which causes this problem is abandoned directly by introducing supplement transactions. The simulation has shown that the proposed security correction method of large consumers direct power trading based on DC power transfer distribution factor is effective.
基金supported by the National Program on Key Basic Research Project of China (973 Program) (Nos. 2013CB036002 and 2014CB046901)the National Key Technology R&D Program of the Ministry of Science and Technology of China (No. 2013BAK06B01)the National Natural Science Foundation of China (No. 51139004)
文摘Detecting, real-time monitoring and early warning of underground water-bearing structures are critically important issues in prevention and mitigation of water inrush hazards in underground engineering. Direct current (DC) resistivity method is a widely used method for routine detection, advanced detection and real-time monitoring of water-bearing structures, due to its high sensitivity to groundwater. In this study, the DC resistivity method applied to underground engineering is reviewed and discussed, including the observation mode, multiple inversions, and real-time monitoring. It is shown that a priori information constrained inversion is desirable to reduce the non-uniqueness of inversion, with which the accuracy of detection can be significantly improved. The focused resistivity method is prospective for advanced detection;with this method, the flanking interference can be reduced and the detection dis-tance is increased subsequently. The time-lapse resistivity inversion method is suitable for the regions with continuous conductivity changes, and it can be used to monitor water inrush in those regions. Based on above-mentioned features of various methods in terms of benefits and limitations, we propose a three-dimensional (3D) induced polarization method characterized with multi-electrode array, and introduce it into tunnels and mines combining with real-time monitoring with time-lapse inversion and cross-hole resistivity method. At last, the prospective applications of DC resistivity method are discussed as follows: (1) available advanced detection technology and instrument in tunnel excavated by tunnel boring machine (TBM), (2) high-resolution detection method in holes, (3) four-dimensional (4D) monitoring technology for water inrush sources, and (4) estimation of water volume in water-bearing structures.
基金This project is funded by the Dongying Science Development Fund Project(DJ2021013).
文摘Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.
基金supported by the National Natural Science Foundation of China(No.52207126)the Natural Science Foundation of Sichuan Province(No.2023NSFSC0296)the Joint Funds of the National Natural Science Foundation of China(No.U22B6006).
文摘DC series-parallel power flow controller(SP-PFC)is a highly efficient device to solve the problem of uncontrolled line current in the bipolar DC distribution system.However,its potential in fault current limiting is not fully explored.In this paper,a self-adaptive action strategy(SAAS)and a parameter optimization method of SP-PFC in bipolar DC distribution systems are proposed.Firstly,the common-and different-mode(CDM)equivalent circuits of the bipolar DC distribution system with SP-PFC in different fault stages are established,which avoids the line coupling inductance.Based on this,the influence of different parameters and line coupling inductance on the fault current limiting capability are investigated.It is found that the SP-PFC has the best fault current limiting capability when the capacitance and inductance of filter are inversely proportional.To realize the adaptability of fault current limiting capability under different fault severities,the SAAS of SP-PFC is proposed.The validity of the CDM equivalent circuits and parameter optimization method,and the effectiveness of the SAAS are verified by simulations and experiments.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.40876094 and JQ10974106)the National High Technology Research and Development Program of China(Grant Nos.2009AA09Z102 and 2008AA09A403)+1 种基金the Excellent Youth Fundation of Shandong Scientific Committee,China(Grant No.JQ201018)the Natural Science Foundation of Shandong Province,China(Grant No.ZR2009AZ002)
文摘The perturbation method is used to study the localization of electric field distribution and the effective nonlinear response of graded composites under an external alternating-current(AC) and direct-current(DC) electric field E app = E 0(1 + sin ωt).The dielectric profile of the cylindrical inclusions is modeled by function ε i(r) = C k r k(r ≤ a),where r is the radius of the cylindrical inclusion,and C k,k,a are parameters.In the dilute limit,the local potentials and the effective nonlinear responses at all harmonics are derived.Meanwhile,the general effective nonlinear responses are also derived and compared with the effective nonlinear responses at harmonics under the AC and DC external field.It is found that the effective nonlinear AC and DC responses at harmonics can be calculated by those of the general effective nonlinear of the graded composites under the external DC electric field.Moreover,the obtained local electrical fields show that the electrical field distribution in the cylindrical inclusions is controllable,and the maximum of the electric field inside the cylinder is at its center.
文摘Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC current limiter and improve the fault current suppression capability, the fault current suppression mechanism of the DC power distribution system is revealed based on the circuit model. Then, based on the mathematical model of the DC breaker, the characteristic parameters of DC breaking are extracted, and then the influence of different characteristic parameters on the breaking characteristics of fault current is studied. Finally, the mathematical model of the collaborative process between DC circuit breaker and DC current limiter is established. The charac-teristic parameters of fault current collaborative suppression are extracted. The coupling effects of different characteristic parameters on the fault current col-laborative suppression are studied. The principle of collaborative configuration of DC circuit breaker and DC current limiter is proposed, and the collaborative suppression ability of DC circuit breaker and DC current limiter to fault current is fully exploited to ensure the safe and reliable operation of the DC power distribution system.