期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Design and Optimization of Terracotta Tube-Based Direct Evaporative Cooling Exchanger: An Analytical Approach to Heat and Mass Transfer
1
作者 Windnigda Zoungrana Makinta Boukar +2 位作者 Ousmane Coulibaly Guy Christian Tubreoumya Antoine Bere 《Open Journal of Applied Sciences》 2025年第1期352-373,共22页
This study develops an analytical model to evaluate the cooling performance of a porous terracotta tubular direct evaporative heat and mass exchanger. By combining energy and mass balance equations with heat and mass ... This study develops an analytical model to evaluate the cooling performance of a porous terracotta tubular direct evaporative heat and mass exchanger. By combining energy and mass balance equations with heat and mass transfer coefficients and air psychrometric correlations, the model provides insights into the impact of design and operational parameters on the exchanger cooling performance. Validated against an established numerical model, it accurately simulates cooling behavior with a Root Mean Square Deviation of 0.43 - 1.18˚C under varying inlet air conditions. The results show that tube geometry, including equivalent diameter, flatness ratio, and length significantly influences cooling outcomes. Smaller diameters enhance wet-bulb effectiveness but reduce cooling capacity, while increased flatness and length improve both. For example, extending the flatness ratio of a 15 mm diameter, 0.6 m long tube from 1 (circular) to 4 raises the exchange surface area from 0.028 to 0.037 m2, increasing wet-bulb effectiveness from 60% to 71%. Recommended diameters range from 5 mm for tubes under 0.5 m to 1 cm for tubes 0.5 to 1 m in length. Optimal air velocities depend on tube length: 1 m/s for tubes under 0.8 m, 1.5 m/s for lengths of 0.8 to 1.2 m, and up to 2 m/s for longer tubes. This model offers a practical alternative to complex numerical and CFD methods, with potential applications in cooling tower optimization for thermal and nuclear power plants and geothermal heat exchangers. 展开更多
关键词 Analytical Modeling Porous Terracotta Tube direct Evaporative cooling Heat and Mass Exchanger Performance Optimization
在线阅读 下载PDF
Direct Laser Cooling Al^+ Ion Optical Clocks 被引量:1
2
作者 张洁 邓科 +1 位作者 罗俊 陆泽晃 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第5期31-35,共5页
The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic... The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of AI+ ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al^+ traps are utilized. The first trap is used to trap a large number of Al^+ ions to improve the stability of the clock laser, while the second trap is used to trap a single Al^+ ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167nm laser. The expected clock laser stability can reach 9.0 × 10^-17/√τ. For the second trap, in addition to 167nm laser Doppler cooling, a second stage pulsed 234nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about 1 × 10^-18. The proposed Al^+ ion optical clock has the potential to become the most accurate and stable optical clock. 展开更多
关键词 direct Laser cooling Al Ion Optical Clocks
原文传递
Waste heat water pumping model with direct contact cooling
3
作者 Kittiwoot Sutthivirode Naris Pratinthong +2 位作者 Pichai Namprakai Natthaphon Roonprasang Taveewat Suparos 《Journal of Central South University》 SCIE EI CAS 2014年第10期3896-3910,共15页
The performance of a patented water pumping model with steam-air power was presented, which operates automatically by direct contact cooling method. The main objective was to study feasibility of a pumping model for u... The performance of a patented water pumping model with steam-air power was presented, which operates automatically by direct contact cooling method. The main objective was to study feasibility of a pumping model for underground water. In this model, a heater installed within the heat tank represented sources of waste heat as energy input for finding appropriate conditions of the 10 L pump model. The system operation had five stages: heating, pumping, vapor flow, cooling, and water suction. The overall water heads of 3, 4.5, 6 and 7.5 m were tested. At the same time, it was found that the pump with 50% air volume is sufficient for pumping water to a desired level. In the experiment, the temperatures in the heating and pumping stages were 100-103 ℃and 80-90 ℃, respectively. The pressure in the pumping stage was 12-18 kPa, and the pressure in the suction stage was about-80 kPa, sufficient for the best performance. It could pump 170 L of water at a 2 m suction head, 120 L at a 3.5 m suction head, 100 L at a 5 m suction head, and 65 L at a 6.5 m suction head in 2 h. A mathematical model for larger pumps was also presented, which operates nearly the same as the present system. Economic analysis of the 10 L pump was also included. 展开更多
关键词 direct contact cooling driving tank steam-air power liquid piston waste heat
在线阅读 下载PDF
New Measurement Method for Direct Cooled Power Electronic with Transmission Fluids
4
作者 Andreas Griesinger Christian Windel +1 位作者 Yungwan Kwak Arthur Petuchow 《Journal of Electronics Cooling and Thermal Control》 2021年第1期1-13,共13页
Power Electronic (PE) will play an essential role in future drive concepts. Nowadays, mainly water/glycol-based cooling media are used to cool PE. Due to their high electrical conductivity (EC), water/glycol-based coo... Power Electronic (PE) will play an essential role in future drive concepts. Nowadays, mainly water/glycol-based cooling media are used to cool PE. Due to their high electrical conductivity (EC), water/glycol-based coolants cannot be used for direct cooling of the electrical components. Direct cooling concepts with dedicated transmission fluids show potential usage of fluid in direct contact with electrified parts. This results in special requirements for the fluids and materials. The aimed action as a coolant requires a defined measurement and characterization of fluid properties and heat transfer in order to assess the cooling ability of a fluid. The purpose of the work was to develop a new measurement setup based on the thermal transient method with which the thermal requirements of cooling fluids for a direct cooling concept can be assessed. With this method, relevant transmission fluids have been tested and the thermal performance compared to indirect cooling effect of water/glycol is discussed. The result of the work is that the measurement method is very well suited for the application-related evaluation of the fluids. Direct oil cooling with transmission fluids could increase heat transfer coefficient by a factor of 3 to 8, compared to the indirect cooing with water/glycol as cooling media. 展开更多
关键词 Thermal Transient Method Heat Transfer Coefficient direct cooling Trans-mission Fluids
在线阅读 下载PDF
Evaporative Cooling Applied in Thermal Power Plants:A Review of the State-ofthe-Art and Typical Case Studies 被引量:1
5
作者 Tiantian Liu Huimin Pang +7 位作者 Suoying He Bin Zhao Zhiyu Zhang Jucheng Wang Zhilan Liu Xiang Huang Yuetao Shi Ming Gao 《Fluid Dynamics & Materials Processing》 EI 2023年第9期2229-2265,共37页
A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-coo... A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-cooled systems,gas turbine inlet cooling,wet cooling towers,and hybrid cooling towers with a crosswind effect.Some effort is provided to describe the advantages related to direct evaporative cooling when it is applied in thermal power plants and illustrate the research gaps,which have not been filled yet.In particular,typical case studies are intentionally used to compare the cooling performances when direct evaporative cooling is implemented in different types of cooling towers,including the natural draft wet cooling tower(NDWCT)and the pre-cooled natural draft dry cooling tower(NDDCT).It is shown that the NDWCT provides the best cooling performance in terms of power station cooling,followed by the pre-cooled NDDCT,and the NDDCT;moreover,the evaporative pre-cooling is able to enhance the cooling performance of NDDCT.Besides,on a yearly basis,better NDDCT cooling performances can be obtained by means of a spray-based pre-cooling approach with respect to wet media pre-cooling.Therefore,the use of nozzle spray is suggested for improvement in the performance of indirect/direct air-cooling systems with controlled water consumption. 展开更多
关键词 direct evaporative cooling cooling tower cooling performance wet media nozzle spray thermal power plants
在线阅读 下载PDF
Optimization framework for energy-efficient and uniform jet impingement cooling for heterogeneous integration packaging
6
作者 Hyunho Cho Insik Lee +3 位作者 Seungwoo Kim Soosik Bang Jaechoon Kim Youngsuk Nam 《Energy and AI》 2025年第3期833-851,共19页
The imbalance in heat power generated by various types of chips poses an obstacle to the reliability and performance of heterogeneous integration(HI)packaging technology,leading to excessive cooling that reduces the s... The imbalance in heat power generated by various types of chips poses an obstacle to the reliability and performance of heterogeneous integration(HI)packaging technology,leading to excessive cooling that reduces the system’s energy efficiency.We propose a framework to optimize the impinging nozzle arrangement for energyefficient uniform jet cooling of HI packages.This framework utilizes a convolutional neural network(CNN)-based surrogate model that learns nozzle arrangements and heating scenarios to predict the temperature nonuniformity of the package.The potential optimal designs predicted by the CNN are used for re-training through an experimentally validated numerical analysis model.Combined with this active learning approach,the proposed hierarchical exploration algorithm accelerates optimization by gradually scaling the design options.The optimization results showed an increase in cooling uniformity by up to 39.5%,while the cooling COP improved by up to 200%across the investigated flow rate range(3–8 L/min).The optimized designs were experimentally validated with a maximum error of 4.34%in average thermal resistance.Our framework achieved up to 45.7%data savings compared to the random sampling-based approach.Along with a discussion on applying the CNN model to untrained conditions to further enhance optimization efficiency,our work represents a novel approach to broadly address the rapidly evolving diverse heating scenarios of HI,contributing to improved cooling energy efficiency in data centers and enhanced reliability of high-performance processors. 展开更多
关键词 Jet impingement direct liquid cooling Heterogeneous integration Active learning Convolutional neural network Non-uniform heat flux
在线阅读 下载PDF
Can Thermal Nonreciprocity Help Radiative Cooling?
7
作者 Run Hu Zihe Chen Sun-Kyung Kim 《Research》 2025年第3期716-718,共3页
Radiative cooling has witnessed substantial progress while its performance is constrained by the thermal reciprocal Kirchhoff’s law.Violating Kirchhoff’s law to pursue nonreciprocal radiative cooling seems promising... Radiative cooling has witnessed substantial progress while its performance is constrained by the thermal reciprocal Kirchhoff’s law.Violating Kirchhoff’s law to pursue nonreciprocal radiative cooling seems promising;however,the energy conservation requirement and radiant flux integrated over the entire hemisphere make the nonreciprocal benefit insignificant.This commentary discusses the practical limits of nonreciprocal radiative cooling and points toward the future direction of directional radiative cooling. 展开更多
关键词 radiative cooling energy conservation energy conservation requirement thermal nonreciprocity directional radiative cooling Kirchhoff s law radiant flux
原文传递
Applying Neural Network in Evaporative Cooler Performance Prediction
8
作者 强天伟 沈恒根 +1 位作者 黄翔 宣永梅 《Journal of Donghua University(English Edition)》 EI CAS 2007年第3期400-403,共4页
The back-propagation (BP) neural network is created to predict the performance of a direct evaporative cooling (DEC) air conditioner with GLASdek pads. The experiment data about the performance of the DEC air cond... The back-propagation (BP) neural network is created to predict the performance of a direct evaporative cooling (DEC) air conditioner with GLASdek pads. The experiment data about the performance of the DEC air conditioner are obtained. Some experiment data are used to train the network until these data can approximate a function, then, simulate the network with the remanent data. The predicted result shows satisfying effects. 展开更多
关键词 neural network direct evaporative cooling airconditioner (evaporative cooler) TRAIN simulate
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部