The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position obser...The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes.展开更多
An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is w...An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.展开更多
Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluat...Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluate its influence on the voltage interaction between VSC-HVDC and line commutated converter based high voltage direct current(LCC-HVDC),this paper proposes a hybrid multi-infeed interaction factor(HMIIF)calculation method considering the voltage regulation control characteristics of VSC-HVDC.Firstly,for a hybrid multi-infeed high voltage direct current system,an additional equivalent operating admittance matrix is constructed to characterize HVDC equipment characteristics under small disturbance.Secondly,based on the characteristic curve between the reactive power and the voltage of a certain VSC-HVDC project,the additional equivalent operating admittance of VSC-HVDC is derived.The additional equivalent operating admittance matrix calculation method is proposed.Thirdly,the equivalent bus impedance matrix is obtained by modifying the alternating current(AC)system admittance matrix with the additional equivalent operating admittance matrix.On this basis,the HMIIF calculation method based on the equivalent bus impedance ratio is proposed.Finally,the effectiveness of the proposed method is verified in a hybrid dual-infeed high voltage direct current system constructed in Power Systems Computer Aided Design(PSCAD),and the influence of voltage regulation control on HMIIF is analyzed.展开更多
Ultra-high-voltage direct current wall bushings are critical components in direct current transmission systems.Temperature variations and abnormal distributions can signal potential equipment failures that threaten sy...Ultra-high-voltage direct current wall bushings are critical components in direct current transmission systems.Temperature variations and abnormal distributions can signal potential equipment failures that threaten system stability.Therefore,monitoring these critical multi-point temperature variations is essential.However,the unique design of the bushings,featuring insulation sheds of periodic shape,distorts infrared temperature measurements by introducing interference points.These interference points,dependent on the measurement's angle and distance,appear irregularly in infrared images,severely impacting the accuracy of multi-point temperature distribution assessments.To address this challenge,an anomaly detection method is proposed that adaptively identifies interference points.The method identifies interference points by comparing pixels and uses a voting mechanism to improve identification accuracy.Compared with traditional methods,this approach presents two main advantages:adaptive identification capability,which enables it to recognise interference points and adapt to changing conditions,and unsupervised learning,which enables it to work effectively without requiring manually labelled data.Experimental tests on 161 bushing infrared images demonstrate the effectiveness of the method,achieving a 100%success rate in identifying localised overheating issues.The method has been integrated into high-voltage direct current transmission anomaly systems and can be used to monitor critical equipment,enhancing system reliability and safety.展开更多
Interface traps generated under hot carrier (HC) stress in LDD nMOST's are monitored by the direct current current voltage (DCIV) measurement technique and charge pumping (CP) technique.The measured and analyzed...Interface traps generated under hot carrier (HC) stress in LDD nMOST's are monitored by the direct current current voltage (DCIV) measurement technique and charge pumping (CP) technique.The measured and analyzed results show that the D peak in DCIV spectrum,which related to the drain region,is affected by a superfluous drain leakage current.The band trap band tunneling current is dominant of this current.展开更多
As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out...As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out a deep technical research and engineering application in this area,and at present,it has been stepped into a fast growing period.This paper gives a general review over China’s VSC based HVDC in terms of engineering technology,application and future development.It comprehensively analyzes the technical difficulties and future development orientation on the aspects of the main configurations of VSC based HVDC system,topological structures of converters,control and protection technologies,flexible DC cables,converter valve tests,etc.It introduces the applicable fields and current status of China’s VSC based HVDC projects,and analyzes the application trends of VSC based HVDC projects both in China and all over the world according to the development characteristics and demands of future power grids.展开更多
Wind power has developed rapidly in recent years,and large-scale wind power facilities connected to power grids will bring many new challenges.Some new operation charac-teristics of power grids with doubly-fed inducti...Wind power has developed rapidly in recent years,and large-scale wind power facilities connected to power grids will bring many new challenges.Some new operation charac-teristics of power grids with doubly-fed induction generator(DFIG)may exhibit,for example voltage phase angle jumps(VPAJ).VPAJ can negatively impact the fault ride through(FRT)performance of DFIG.This paper firstly investigates the physical mechanism and the operation characteristics of DFIG with VPAJ.It is noted that the current control strategies designed for voltage amplitude changes are not suitable for VPAJ.Secondly,the paper develops an FRT optimization control strategy under VPAJ which optimizes the DFIG operation characteristics.Finally,simulations of a 250 MW wind farm are presented which validate the proposed FRT strategy.展开更多
An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insul...An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insulated bushing,rated for 500 kV dc and terminated on a thyristor-controlled HVDC converter bridge.The measurement of PD within the HVDC station environment is particularly challenging due to the high levels of electromagnetic noise caused by thyristor switching events and external air-corona from the neighboring high-voltage equipment.An additional challenge is the""mixed"voltage stress on the bushing insulation,which has both ac and dc high-voltage components.There are also fast transients during the firing of thyristors in the HVDC conversion process that cause added stress to the insulation.As a result,the analysis and interpretation of PD data for HVDC equipment is more complex;PD pulses may occur in response to the ac,dc,or switching transient voltage stresses.In this paper,an online PD measurement strategy for noise filtering and isolation of PD sources within the bushing are discussed.The PD measurement data is plotted on a phase-resolved diagram where the line supply power cord voltage was used as a reference. The phase-resolved diagram appears to suggest that the fast transients,caused during switching,trigger some PD events.Measurements were also performed with the aid of a modern PD measurement instrument having noise separation capabilities.The findings from the online PD measurements are verified with physical evidence,found after the bushing was removed from service,suggested internal PD had occurred inside the bushing.展开更多
Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system...Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system stability will be affected by the performance of wind power plants,especially in the event of a fault.In this paper,the improvement of the dynamic stability in power system equipped by wind farm is examined through the supplementary controller design in the high voltage direct current(HVDC)based on voltage source converter(VSC)transmission system.In this regard,impacts of the VSC HVDC system and wind farm on the improvement of system stability are considered.Also,an algorithm based on controllability(observability)concept is proposed to select most appropriate and effective coupling between inputs-outputs(IO)signals of system in different work conditions.The selected coupling is used to apply damping controller signal.Finally,a fractional order PID controller(FO-PID)based on exchange market algorithm(EMA)is designed as damping controller.The analysis of the results shows that the wind farm does not directly contribute to the improvement of the dynamic stability of power system.However,it can increase the controllability of the oscillatory mode and improve the performance of the supplementary controller.展开更多
With rapid increase of distributed solar power generation and direct current(DC)based loads such as data centers,electric vehicles(EVs),and DC household appliances,the development trend of the power system is changed ...With rapid increase of distributed solar power generation and direct current(DC)based loads such as data centers,electric vehicles(EVs),and DC household appliances,the development trend of the power system is changed from conventional alternate current(AC)to DC.Traditional AC power systems can scarcely meet the development demand of new DC trends,especially since both the generation side and load side are comprised of DC-based electronic power components.With this background,low voltage direct current supply and utilization system(LVDCSUS)has attracted more and more attention for its great advantages over an AC grid to overcome challenges in operation,reliability,and energy loss in renewable energy connection,DC load power utilization and a number of other aspects.However,the definition of the LVDCSUS is still not clear even though many demonstration projects have been put into planning and operation.In order to provide a clear description of LVDCSUS,first,the characteristics of LVDCSUS are illustrated in this paper to show the advance of the LVDCSUS.Second,the potential application scenarios of LVDCSUS are presented in this paper.Third,application of LVDCSUS technologies and some demonstration projects in China are introduced.Besides the development of the LVDCSUS,key technologies,including but not limited to planning and design,voltage levels,control strategies,and key equipment of LVDCSUS,are discussed in this paper.Finally,future application areas and the research orientations of LVDCSUS are analyzed.展开更多
In contrast to the conventional direct current railway electrification system(DC-RES),the medium voltage direct current(MVDC)-RES is considered promising for long-distance high-speed corridors.In the MVDC-RES,traction...In contrast to the conventional direct current railway electrification system(DC-RES),the medium voltage direct current(MVDC)-RES is considered promising for long-distance high-speed corridors.In the MVDC-RES,traction substations(TSSs)are placed much farther and train loads are much heavier than in the conventional DC-RES.Hence,the MVDC-RES brings a drastic change in catenary voltage,TSS spacing,and train loading,which affects rail potential and stray current.In this connection,this work performs some significant quantitative analysis of rail potential and stray current in the MVDC-RES environment.An MVDC simulation model is proposed and different grounding schemes are analyzed for a single-train and two TSSs scenario as well as for a multi-train multi-TSS scenario.According to the simulation and analysis,the maximum values of rail potential and stray current at MVDC-RES distances and the maximum safe distance between adjacent TSSs are determined.展开更多
Voltage source converter high-voltage direct current (VSC-HVDC) is a new power transmission technology pref- erable in small or medium power transmission. In this paper we discuss a new control system based on space...Voltage source converter high-voltage direct current (VSC-HVDC) is a new power transmission technology pref- erable in small or medium power transmission. In this paper we discuss a new control system based on space vector modulation (SVM) without any voltage line sensors. Using direct power control (DPC) SVM and a new double synchronous reference frame phase-locked loop (DSRF-PLL) approach, the control system is resistant to the majority of line voltage disturbances. Also, the system response has accelerated by using a feed forward power decoupled loop. The operation of this control strategy was verified in a SIMULINK/MATLAB simulation environment. To validate this control system, a 5 kV.A prototype system was constructed. Compared to the original controllers, the current total harmonic distortion (THD), the active and reactive deviations and the DC voltage overshoot were lowered by 2.5%, 6.2% and 8%, respectively. The rectifier power factor in the worst condition was 0.93 and the DC voltage settling time was 0.2 s.展开更多
Congo River has abundant hydropower resources,and large-scale cascade power stations,such as the Grand Inga,can be constructed in downstream locations.However,the fragile economic foundations of the Democratic Republi...Congo River has abundant hydropower resources,and large-scale cascade power stations,such as the Grand Inga,can be constructed in downstream locations.However,the fragile economic foundations of the Democratic Republic of the Congo and neighbor!ng Central African countries,and the small-scale regional power consumption market prohibit the implementation of large-scale hydro power projects.As the high-voltage,I on g-dista nee power transmission tech no logy matures,hydropower from the Grand Inga can be delivered to load centers in other regions of Africa.This study establishes a 6 dime nsional comprehe nsive assessment model using the best-worst method to evaluate large-scale,I on g-distance,cross-border power intercon necti on projects.The model is applied to evaluate all the can didate in ter-regional power delivery schemes of the Inga III hydropower station,and the evaluation results can effectively help investment institutions and policy makers in policy making and potential market targeting.展开更多
Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC g...Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.展开更多
In order to effectively imitate the dynamic operation characteristics of the HVDC (high voltage direct current) power transmission system at a real ±500kV HVDC transmission project, the electromechanical-electr...In order to effectively imitate the dynamic operation characteristics of the HVDC (high voltage direct current) power transmission system at a real ±500kV HVDC transmission project, the electromechanical-electromagnetic transient hybrid simulation was carried out based on advanced digital power system simulator (ADPSS). In the simulation analysis, the built hybrid model's dynamic response outputs under three different fault conditions are considered, and by comparing with the selected fault recording waveforms, the validities of the simulation waveforms are estimated qualitatively. It can be ascertained that the hybrid simulation model has the ability to describe the HVDC system's dynamic change trends well under some special fault conditions.展开更多
More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in o...More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current(AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current(MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current(PSCAD/EMTDC) system software package.Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.展开更多
This paper,the kinetic equation,traction force,and braking force for railway trains are reviewed.In addition,the driving characteristics are interpreted as to how the power of the electric vehicle relates to the weigh...This paper,the kinetic equation,traction force,and braking force for railway trains are reviewed.In addition,the driving characteristics are interpreted as to how the power of the electric vehicle relates to the weight,speed,track curve,and track gradient of the electric vehicle.The driving characteristics of these trains are analyzed through PSCAD/EMTDC(power systems computer aided design/electromagnetic transients including DC)modeling.展开更多
Under weak grid conditions,grid impedance is coupled with a control system for voltage source converter based high-voltage direct current(VSC-HVDC)systems,resulting in decreased synchronization stability.Unfortunately...Under weak grid conditions,grid impedance is coupled with a control system for voltage source converter based high-voltage direct current(VSC-HVDC)systems,resulting in decreased synchronization stability.Unfortunately,most studies are based on the assumption that impedance ratio(R/X)is sufficiently small to ignore the effects of grid impedance.In this study,we establish a dynamic coupling model that includes grid impedance and control loops,revealing the influence mechanism of R/X on synchronization stability from a physical perspective.We also quantify the stability range of R/X in the static analysis model and introduce a sensitivity factor to measure its effect on voltage stability.Additionally,we utilize a dynamic analysis model to evaluate power angle convergence,proposing a corresponding stability criterion.We then present a method of synchronous voltage reconstruction aimed at enhancing the grid strength.Theoretical analysis shows that this method can effectively mitigate the effects of coupling between grid impedance and the controller under weak grid conditions,ensuring stable operation even under extremely weak grid conditions.Experiments validate the accuracy and effectiveness of the analysis and method.展开更多
Flexible and all-solid-state zinc-air batteries(ZABs)are highly useful and also in demand due to their theoretical high energy densities and special applications.The limitation in their performance arises due to their...Flexible and all-solid-state zinc-air batteries(ZABs)are highly useful and also in demand due to their theoretical high energy densities and special applications.The limitation in their performance arises due to their catalyst-coated cathode electrodes in terms of catalytic activity and stability as well as cost.In this paper,a novel and environmentally friendly activation strategy is developed to activate the carbon cloth(CC)for the electrodes.The activated CC serves as a catalyst-free air cathode with high conductivity,excellent mechanical strength,and flexibility,in addition to low cost.The strategy is performed by simply electro-oxidizing and electroreducing CC under ultrahigh direct current(DC)voltage in a diluted NH4Cl aqueous electrolyte.It is found that the electro-oxidation not only results in the formation of a graphene-like exfoliated carbon layer on the surface of CC but also induces the incorporation of oxygen-containing groups and doping of nitrogen and chloride atoms.After the electroreduction,theπ-conjugated carbon network of CC is partially restored,leading to the recovery of electroconductivity.Such an electroactivated CC shows excellent oxygen reduction reaction activity.The aqueous flexibility and all-solid-state ZABs are assembled using such an electroactivated CC cathode without any catalyst loading.Both ZABs can achieve good durability and deliver high peak power density and an energy density as high as 690 Wh kg^(−1),demonstrating the excellent potential of this electroactivated CC in practical devices.展开更多
In just 5 milliseconds-0.005 seconds-clean energy gen-erated in Qinghai Province,northwest China,travels over 1,500 km to the central province of Henan.“In the blink of an eye,Qinghai has already sent electricity to ...In just 5 milliseconds-0.005 seconds-clean energy gen-erated in Qinghai Province,northwest China,travels over 1,500 km to the central province of Henan.“In the blink of an eye,Qinghai has already sent electricity to Henan multiple times,”Lu Jinlong,a tech-nician at the Qingnan Converter Station in Gonghe County,Hainan Tibetan Autonomous Prefecture,Qinghai,told reporters during a group interview on July 25.The Qingnan Converter Station is the starting point of the Qinghai-Henan±800-kilovolt(KV)ultra-high-voltage direct current(UHVDC)project.展开更多
基金This work was supported in part by the National Natural Science Foundation of China(NSFC)under Grants 51707079 and 51877093in part by the National Key Research and Development Program of China(Project ID:YS2018YFGH000200)in part by the Fundamental Research Funds for the Central Universities(Project ID:2019kfyXMBZ031).
文摘The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes.
文摘An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.
基金supported by the Technology Project of the State Grid Corporation Headquarters Management(Contract No.5100-202158467A-0-0-00).
文摘Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluate its influence on the voltage interaction between VSC-HVDC and line commutated converter based high voltage direct current(LCC-HVDC),this paper proposes a hybrid multi-infeed interaction factor(HMIIF)calculation method considering the voltage regulation control characteristics of VSC-HVDC.Firstly,for a hybrid multi-infeed high voltage direct current system,an additional equivalent operating admittance matrix is constructed to characterize HVDC equipment characteristics under small disturbance.Secondly,based on the characteristic curve between the reactive power and the voltage of a certain VSC-HVDC project,the additional equivalent operating admittance of VSC-HVDC is derived.The additional equivalent operating admittance matrix calculation method is proposed.Thirdly,the equivalent bus impedance matrix is obtained by modifying the alternating current(AC)system admittance matrix with the additional equivalent operating admittance matrix.On this basis,the HMIIF calculation method based on the equivalent bus impedance ratio is proposed.Finally,the effectiveness of the proposed method is verified in a hybrid dual-infeed high voltage direct current system constructed in Power Systems Computer Aided Design(PSCAD),and the influence of voltage regulation control on HMIIF is analyzed.
基金National Natural Science Foundation of China,Grant/Award Numbers:62106033,42367066。
文摘Ultra-high-voltage direct current wall bushings are critical components in direct current transmission systems.Temperature variations and abnormal distributions can signal potential equipment failures that threaten system stability.Therefore,monitoring these critical multi-point temperature variations is essential.However,the unique design of the bushings,featuring insulation sheds of periodic shape,distorts infrared temperature measurements by introducing interference points.These interference points,dependent on the measurement's angle and distance,appear irregularly in infrared images,severely impacting the accuracy of multi-point temperature distribution assessments.To address this challenge,an anomaly detection method is proposed that adaptively identifies interference points.The method identifies interference points by comparing pixels and uses a voting mechanism to improve identification accuracy.Compared with traditional methods,this approach presents two main advantages:adaptive identification capability,which enables it to recognise interference points and adapt to changing conditions,and unsupervised learning,which enables it to work effectively without requiring manually labelled data.Experimental tests on 161 bushing infrared images demonstrate the effectiveness of the method,achieving a 100%success rate in identifying localised overheating issues.The method has been integrated into high-voltage direct current transmission anomaly systems and can be used to monitor critical equipment,enhancing system reliability and safety.
文摘Interface traps generated under hot carrier (HC) stress in LDD nMOST's are monitored by the direct current current voltage (DCIV) measurement technique and charge pumping (CP) technique.The measured and analyzed results show that the D peak in DCIV spectrum,which related to the drain region,is affected by a superfluous drain leakage current.The band trap band tunneling current is dominant of this current.
基金This work was supported by National Natural Science Foundation of China(No.51261130471).
文摘As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out a deep technical research and engineering application in this area,and at present,it has been stepped into a fast growing period.This paper gives a general review over China’s VSC based HVDC in terms of engineering technology,application and future development.It comprehensively analyzes the technical difficulties and future development orientation on the aspects of the main configurations of VSC based HVDC system,topological structures of converters,control and protection technologies,flexible DC cables,converter valve tests,etc.It introduces the applicable fields and current status of China’s VSC based HVDC projects,and analyzes the application trends of VSC based HVDC projects both in China and all over the world according to the development characteristics and demands of future power grids.
基金This work was supported by The National Natural Science Foundation of China(No.51577174).
文摘Wind power has developed rapidly in recent years,and large-scale wind power facilities connected to power grids will bring many new challenges.Some new operation charac-teristics of power grids with doubly-fed induction generator(DFIG)may exhibit,for example voltage phase angle jumps(VPAJ).VPAJ can negatively impact the fault ride through(FRT)performance of DFIG.This paper firstly investigates the physical mechanism and the operation characteristics of DFIG with VPAJ.It is noted that the current control strategies designed for voltage amplitude changes are not suitable for VPAJ.Secondly,the paper develops an FRT optimization control strategy under VPAJ which optimizes the DFIG operation characteristics.Finally,simulations of a 250 MW wind farm are presented which validate the proposed FRT strategy.
基金Manitoba Hydro for funding and supporting this research
文摘An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insulated bushing,rated for 500 kV dc and terminated on a thyristor-controlled HVDC converter bridge.The measurement of PD within the HVDC station environment is particularly challenging due to the high levels of electromagnetic noise caused by thyristor switching events and external air-corona from the neighboring high-voltage equipment.An additional challenge is the""mixed"voltage stress on the bushing insulation,which has both ac and dc high-voltage components.There are also fast transients during the firing of thyristors in the HVDC conversion process that cause added stress to the insulation.As a result,the analysis and interpretation of PD data for HVDC equipment is more complex;PD pulses may occur in response to the ac,dc,or switching transient voltage stresses.In this paper,an online PD measurement strategy for noise filtering and isolation of PD sources within the bushing are discussed.The PD measurement data is plotted on a phase-resolved diagram where the line supply power cord voltage was used as a reference. The phase-resolved diagram appears to suggest that the fast transients,caused during switching,trigger some PD events.Measurements were also performed with the aid of a modern PD measurement instrument having noise separation capabilities.The findings from the online PD measurements are verified with physical evidence,found after the bushing was removed from service,suggested internal PD had occurred inside the bushing.
文摘Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system stability will be affected by the performance of wind power plants,especially in the event of a fault.In this paper,the improvement of the dynamic stability in power system equipped by wind farm is examined through the supplementary controller design in the high voltage direct current(HVDC)based on voltage source converter(VSC)transmission system.In this regard,impacts of the VSC HVDC system and wind farm on the improvement of system stability are considered.Also,an algorithm based on controllability(observability)concept is proposed to select most appropriate and effective coupling between inputs-outputs(IO)signals of system in different work conditions.The selected coupling is used to apply damping controller signal.Finally,a fractional order PID controller(FO-PID)based on exchange market algorithm(EMA)is designed as damping controller.The analysis of the results shows that the wind farm does not directly contribute to the improvement of the dynamic stability of power system.However,it can increase the controllability of the oscillatory mode and improve the performance of the supplementary controller.
文摘With rapid increase of distributed solar power generation and direct current(DC)based loads such as data centers,electric vehicles(EVs),and DC household appliances,the development trend of the power system is changed from conventional alternate current(AC)to DC.Traditional AC power systems can scarcely meet the development demand of new DC trends,especially since both the generation side and load side are comprised of DC-based electronic power components.With this background,low voltage direct current supply and utilization system(LVDCSUS)has attracted more and more attention for its great advantages over an AC grid to overcome challenges in operation,reliability,and energy loss in renewable energy connection,DC load power utilization and a number of other aspects.However,the definition of the LVDCSUS is still not clear even though many demonstration projects have been put into planning and operation.In order to provide a clear description of LVDCSUS,first,the characteristics of LVDCSUS are illustrated in this paper to show the advance of the LVDCSUS.Second,the potential application scenarios of LVDCSUS are presented in this paper.Third,application of LVDCSUS technologies and some demonstration projects in China are introduced.Besides the development of the LVDCSUS,key technologies,including but not limited to planning and design,voltage levels,control strategies,and key equipment of LVDCSUS,are discussed in this paper.Finally,future application areas and the research orientations of LVDCSUS are analyzed.
文摘In contrast to the conventional direct current railway electrification system(DC-RES),the medium voltage direct current(MVDC)-RES is considered promising for long-distance high-speed corridors.In the MVDC-RES,traction substations(TSSs)are placed much farther and train loads are much heavier than in the conventional DC-RES.Hence,the MVDC-RES brings a drastic change in catenary voltage,TSS spacing,and train loading,which affects rail potential and stray current.In this connection,this work performs some significant quantitative analysis of rail potential and stray current in the MVDC-RES environment.An MVDC simulation model is proposed and different grounding schemes are analyzed for a single-train and two TSSs scenario as well as for a multi-train multi-TSS scenario.According to the simulation and analysis,the maximum values of rail potential and stray current at MVDC-RES distances and the maximum safe distance between adjacent TSSs are determined.
文摘Voltage source converter high-voltage direct current (VSC-HVDC) is a new power transmission technology pref- erable in small or medium power transmission. In this paper we discuss a new control system based on space vector modulation (SVM) without any voltage line sensors. Using direct power control (DPC) SVM and a new double synchronous reference frame phase-locked loop (DSRF-PLL) approach, the control system is resistant to the majority of line voltage disturbances. Also, the system response has accelerated by using a feed forward power decoupled loop. The operation of this control strategy was verified in a SIMULINK/MATLAB simulation environment. To validate this control system, a 5 kV.A prototype system was constructed. Compared to the original controllers, the current total harmonic distortion (THD), the active and reactive deviations and the DC voltage overshoot were lowered by 2.5%, 6.2% and 8%, respectively. The rectifier power factor in the worst condition was 0.93 and the DC voltage settling time was 0.2 s.
基金National Key Reaearch and Development Program of China(2016YFB0900400).
文摘Congo River has abundant hydropower resources,and large-scale cascade power stations,such as the Grand Inga,can be constructed in downstream locations.However,the fragile economic foundations of the Democratic Republic of the Congo and neighbor!ng Central African countries,and the small-scale regional power consumption market prohibit the implementation of large-scale hydro power projects.As the high-voltage,I on g-dista nee power transmission tech no logy matures,hydropower from the Grand Inga can be delivered to load centers in other regions of Africa.This study establishes a 6 dime nsional comprehe nsive assessment model using the best-worst method to evaluate large-scale,I on g-distance,cross-border power intercon necti on projects.The model is applied to evaluate all the can didate in ter-regional power delivery schemes of the Inga III hydropower station,and the evaluation results can effectively help investment institutions and policy makers in policy making and potential market targeting.
基金This project is funded by the Dongying Science Development Fund Project(DJ2021013).
文摘Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.
基金supported by the General Program of Chinese Postdoctoral Science Foundation under Grant No.2012M511595
文摘In order to effectively imitate the dynamic operation characteristics of the HVDC (high voltage direct current) power transmission system at a real ±500kV HVDC transmission project, the electromechanical-electromagnetic transient hybrid simulation was carried out based on advanced digital power system simulator (ADPSS). In the simulation analysis, the built hybrid model's dynamic response outputs under three different fault conditions are considered, and by comparing with the selected fault recording waveforms, the validities of the simulation waveforms are estimated qualitatively. It can be ascertained that the hybrid simulation model has the ability to describe the HVDC system's dynamic change trends well under some special fault conditions.
文摘More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current(AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current(MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current(PSCAD/EMTDC) system software package.Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.
基金supported by the Korea Institute of Energy Technology Evaluation and Planning(KETEP)and the Ministry of Trade,Industry&Energy(MOTIE)of the Republic of Korea(No.20225500000110).
文摘This paper,the kinetic equation,traction force,and braking force for railway trains are reviewed.In addition,the driving characteristics are interpreted as to how the power of the electric vehicle relates to the weight,speed,track curve,and track gradient of the electric vehicle.The driving characteristics of these trains are analyzed through PSCAD/EMTDC(power systems computer aided design/electromagnetic transients including DC)modeling.
基金supported in part by the National Natural Science Foundation of China(No.52077037)in part by the Science and Technology Projects of Jiangsu Province(No.BE2022016).
文摘Under weak grid conditions,grid impedance is coupled with a control system for voltage source converter based high-voltage direct current(VSC-HVDC)systems,resulting in decreased synchronization stability.Unfortunately,most studies are based on the assumption that impedance ratio(R/X)is sufficiently small to ignore the effects of grid impedance.In this study,we establish a dynamic coupling model that includes grid impedance and control loops,revealing the influence mechanism of R/X on synchronization stability from a physical perspective.We also quantify the stability range of R/X in the static analysis model and introduce a sensitivity factor to measure its effect on voltage stability.Additionally,we utilize a dynamic analysis model to evaluate power angle convergence,proposing a corresponding stability criterion.We then present a method of synchronous voltage reconstruction aimed at enhancing the grid strength.Theoretical analysis shows that this method can effectively mitigate the effects of coupling between grid impedance and the controller under weak grid conditions,ensuring stable operation even under extremely weak grid conditions.Experiments validate the accuracy and effectiveness of the analysis and method.
基金National Nature Science Foundation of China,Grant/Award Number:21908124。
文摘Flexible and all-solid-state zinc-air batteries(ZABs)are highly useful and also in demand due to their theoretical high energy densities and special applications.The limitation in their performance arises due to their catalyst-coated cathode electrodes in terms of catalytic activity and stability as well as cost.In this paper,a novel and environmentally friendly activation strategy is developed to activate the carbon cloth(CC)for the electrodes.The activated CC serves as a catalyst-free air cathode with high conductivity,excellent mechanical strength,and flexibility,in addition to low cost.The strategy is performed by simply electro-oxidizing and electroreducing CC under ultrahigh direct current(DC)voltage in a diluted NH4Cl aqueous electrolyte.It is found that the electro-oxidation not only results in the formation of a graphene-like exfoliated carbon layer on the surface of CC but also induces the incorporation of oxygen-containing groups and doping of nitrogen and chloride atoms.After the electroreduction,theπ-conjugated carbon network of CC is partially restored,leading to the recovery of electroconductivity.Such an electroactivated CC shows excellent oxygen reduction reaction activity.The aqueous flexibility and all-solid-state ZABs are assembled using such an electroactivated CC cathode without any catalyst loading.Both ZABs can achieve good durability and deliver high peak power density and an energy density as high as 690 Wh kg^(−1),demonstrating the excellent potential of this electroactivated CC in practical devices.
文摘In just 5 milliseconds-0.005 seconds-clean energy gen-erated in Qinghai Province,northwest China,travels over 1,500 km to the central province of Henan.“In the blink of an eye,Qinghai has already sent electricity to Henan multiple times,”Lu Jinlong,a tech-nician at the Qingnan Converter Station in Gonghe County,Hainan Tibetan Autonomous Prefecture,Qinghai,told reporters during a group interview on July 25.The Qingnan Converter Station is the starting point of the Qinghai-Henan±800-kilovolt(KV)ultra-high-voltage direct current(UHVDC)project.