A diagnostic system of soft x-ray diode-array was set up for HT-7 superconducting tokamak. The system consists of two slot-aperture cameras and is capable of measuring the soft x-ray emission from the plasma on HT-7 d...A diagnostic system of soft x-ray diode-array was set up for HT-7 superconducting tokamak. The system consists of two slot-aperture cameras and is capable of measuring the soft x-ray emission from the plasma on HT-7 device with a high resolution in space and a high response in time. Both cameras, located separately in a horizontal port and a vertical port each with thirty-seven detectors of An-Si surface-barrier diode (SBD) can view the same toroidal cross-section of the plasma from different poloidal chords. In this paper, the structure, principle and performance of the diagnostic system are described and some experimental results observed are presented.展开更多
文摘A diagnostic system of soft x-ray diode-array was set up for HT-7 superconducting tokamak. The system consists of two slot-aperture cameras and is capable of measuring the soft x-ray emission from the plasma on HT-7 device with a high resolution in space and a high response in time. Both cameras, located separately in a horizontal port and a vertical port each with thirty-seven detectors of An-Si surface-barrier diode (SBD) can view the same toroidal cross-section of the plasma from different poloidal chords. In this paper, the structure, principle and performance of the diagnostic system are described and some experimental results observed are presented.