Au/Zn O/n-type Si device is obtained using atomic layer deposition(ALD) for Zn O layer, and some main electrical parameters are investigated, such as surface/interface state(Nss), barrier height(Φb), series res...Au/Zn O/n-type Si device is obtained using atomic layer deposition(ALD) for Zn O layer, and some main electrical parameters are investigated, such as surface/interface state(Nss), barrier height(Φb), series resistance(Rs), donor concentration(Nd), and dielectric characterization depending on frequency or voltage. These parameters are acquired by use of impedance spectroscopy measurements at frequencies ranging from 10 k Hz to 1 MHz and the direct current(DC) bias voltages in a range from-2 V to +2 V at room temperature are used. The main electrical parameters and dielectric parameters,such as dielectric constant(ε"), dielectric loss(ε"), loss tangent(tan δ), the real and imaginary parts of electric modulus(M and M), and alternating current(AC) electrical conductivity(σ) are affected by changing voltage and frequency. The characterizations show that some main electrical parameters usually decrease with increasing frequency because charge carriers at surface states have not enough time to fallow an external AC signal at high frequencies, and all dielectric parameters strongly depend on the voltage and frequency especially in the depletion and accumulation regions. Consequently, it can be concluded that interfacial polarization and interface charges can easily follow AC signal at low frequencies.展开更多
In the transport studies of topological insulators, microflakes exfoliated from bulk single crystals are often used because of the convenience in sample preparation and the accessibility to high carrier mobilities. He...In the transport studies of topological insulators, microflakes exfoliated from bulk single crystals are often used because of the convenience in sample preparation and the accessibility to high carrier mobilities. Here, based on finite element analysis, we show that for the non-Hall-bar shaped topological insulator samples, the measured four-point resistances can be substantially modified by the sample geometry, bulk and surface resistivities,and magnetic field. Geometry correction factors must be introduced for accurately converting the four-point resistances to the longitudinal resistivity and Hall resistivity. The magnetic field dependence of inhomogeneous current density distribution can lead to pronounced positive magnetoresistance and nonlinear Hall effect that would not exist in the samples of ideal Hall bar geometry.展开更多
We investigate the electronic transport properties of dipyrimidinyl-diphenyl sandwiched between two armchair graphene nanoribbon electrodes using the nonequilibrium Green function formalism combined with a first-princ...We investigate the electronic transport properties of dipyrimidinyl-diphenyl sandwiched between two armchair graphene nanoribbon electrodes using the nonequilibrium Green function formalism combined with a first-principles method based on density functional theory. Among the three models M1–M3, M1 is not doped with a heteroatom. In the left parts of M2 and M3, nitrogen atoms are doped at two edges of the nanoribbon. In the right parts, nitrogen atoms are doped at one center and at the edges of M2 and M3, respectively. Comparisons of M1, M2 and M3 show obvious rectifying characteristics, and the maximum rectification ratios are up to 42.9 in M2. The results show that the rectifying behavior is strongly dependent on the doping position of electrodes. A higher rectification ratio can be found in the dipyrimidinyl-diphenyl molecular device with asymmetric doping of left and right electrodes, which suggests that this system has a broader application in future logic and memory devices.展开更多
Low-level laser therapy (LLLT) or cold laser has been used in medicine for several decades. However, the method utilizes a direct contact of the light beam with a patient. Further research resulted in development of a...Low-level laser therapy (LLLT) or cold laser has been used in medicine for several decades. However, the method utilizes a direct contact of the light beam with a patient. Further research resulted in development of another method that enables remote transmission of the pharmacological properties of a medicament into a human body with the application of low-level laser radiation as the light source. 18 patients with different viral diseases were treated with the antiviral drugs placed into the field formed by the unexplained properties of low-level laser radiation of the “device for transfer of the pharmacological properties of a drug into the patient’s body”. This resulted in improvement of the patient’s condition, the absence of side effects and adverse reactions when using drugs in the proposed device and shortened therapy period for patients with chronic hepatitis C infection and Covid-19 patients. The long-term follow-up of the patients with chronic hepatitis B infection showed that hepatitis B virus remained at low replication levels under the influence of the therapy, which made it possible to avoid such formidable complications of the disease as cirrhosis of the liver and liver cancer.展开更多
文摘Au/Zn O/n-type Si device is obtained using atomic layer deposition(ALD) for Zn O layer, and some main electrical parameters are investigated, such as surface/interface state(Nss), barrier height(Φb), series resistance(Rs), donor concentration(Nd), and dielectric characterization depending on frequency or voltage. These parameters are acquired by use of impedance spectroscopy measurements at frequencies ranging from 10 k Hz to 1 MHz and the direct current(DC) bias voltages in a range from-2 V to +2 V at room temperature are used. The main electrical parameters and dielectric parameters,such as dielectric constant(ε"), dielectric loss(ε"), loss tangent(tan δ), the real and imaginary parts of electric modulus(M and M), and alternating current(AC) electrical conductivity(σ) are affected by changing voltage and frequency. The characterizations show that some main electrical parameters usually decrease with increasing frequency because charge carriers at surface states have not enough time to fallow an external AC signal at high frequencies, and all dielectric parameters strongly depend on the voltage and frequency especially in the depletion and accumulation regions. Consequently, it can be concluded that interfacial polarization and interface charges can easily follow AC signal at low frequencies.
基金Supported by the National Natural Science Foundation of China (Grant No. 11961141011)the Strategic Priority Research Program of Chinese Academy of Sciences (Grant No. XDB28000000)the National Key Research and Development Program of China(Grant No. 2016YFA0300600)。
文摘In the transport studies of topological insulators, microflakes exfoliated from bulk single crystals are often used because of the convenience in sample preparation and the accessibility to high carrier mobilities. Here, based on finite element analysis, we show that for the non-Hall-bar shaped topological insulator samples, the measured four-point resistances can be substantially modified by the sample geometry, bulk and surface resistivities,and magnetic field. Geometry correction factors must be introduced for accurately converting the four-point resistances to the longitudinal resistivity and Hall resistivity. The magnetic field dependence of inhomogeneous current density distribution can lead to pronounced positive magnetoresistance and nonlinear Hall effect that would not exist in the samples of ideal Hall bar geometry.
基金Supported by the National Natural Science Foundation of China under Grant Nos 11504283 and 21503153the Natural Science Foundation of Shaanxi Province under Grant No 2014JM1025the Science and Technology Star Project of Shaanxi Province under Grant No 2016KJXX-45
文摘We investigate the electronic transport properties of dipyrimidinyl-diphenyl sandwiched between two armchair graphene nanoribbon electrodes using the nonequilibrium Green function formalism combined with a first-principles method based on density functional theory. Among the three models M1–M3, M1 is not doped with a heteroatom. In the left parts of M2 and M3, nitrogen atoms are doped at two edges of the nanoribbon. In the right parts, nitrogen atoms are doped at one center and at the edges of M2 and M3, respectively. Comparisons of M1, M2 and M3 show obvious rectifying characteristics, and the maximum rectification ratios are up to 42.9 in M2. The results show that the rectifying behavior is strongly dependent on the doping position of electrodes. A higher rectification ratio can be found in the dipyrimidinyl-diphenyl molecular device with asymmetric doping of left and right electrodes, which suggests that this system has a broader application in future logic and memory devices.
文摘Low-level laser therapy (LLLT) or cold laser has been used in medicine for several decades. However, the method utilizes a direct contact of the light beam with a patient. Further research resulted in development of another method that enables remote transmission of the pharmacological properties of a medicament into a human body with the application of low-level laser radiation as the light source. 18 patients with different viral diseases were treated with the antiviral drugs placed into the field formed by the unexplained properties of low-level laser radiation of the “device for transfer of the pharmacological properties of a drug into the patient’s body”. This resulted in improvement of the patient’s condition, the absence of side effects and adverse reactions when using drugs in the proposed device and shortened therapy period for patients with chronic hepatitis C infection and Covid-19 patients. The long-term follow-up of the patients with chronic hepatitis B infection showed that hepatitis B virus remained at low replication levels under the influence of the therapy, which made it possible to avoid such formidable complications of the disease as cirrhosis of the liver and liver cancer.