A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo...A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.展开更多
An efficient and accurate analytical method was developed for the simultaneous determination of 20 synthetic food additives, including three sweeteners,seven food colorants,nine synthetic preservatives and caffeine,by...An efficient and accurate analytical method was developed for the simultaneous determination of 20 synthetic food additives, including three sweeteners,seven food colorants,nine synthetic preservatives and caffeine,by high performance liquid chromatography (HPLC) with photodiode array detector(PDA).This method permits the detection of food additives at very low concentrations(0.005-0.150μg/mL).The applicability was verified by the determination of food additives present in various foodstuffs.展开更多
A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consis...A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consists of isocratic eluation with a mixture of 60% buffer (10 mM sodium dihyrogenphosphate-10 mM sodium dodecyl sulphate) and 40% acetonitrile with final pH 7.0 with flow rate of 1.0 mL/min on a Kromasil~ Akzo Nobel RP-18 (4.6 mm ID ~ 250 mm, 5 ~tm) column at an ambient temperature. Photo diode array detection was performed in program mode at 234 rim. The analyte and diazepam as internal standard (IS) were extracted from plasma using 10% trichloroacetic acid. The assay was linear over the therapeutic concentration range of 20-2,500 ng/mL for metformin HCI with correlation coefficient of r = 0.9999. Limit of quantitation was 20 ng/mL. The results obtained for intraJinter day accuracy and precision complied very well with the generally accepted criteria for bio-analytical assay. The method was applied to bioequivalence (BE) study of metformin HCI in healthy Indonesian volunteers after treatment with 750 mg XR metformin HCI. This BE study shows that the two formulations are equivalent so that they were therapeutically interchangeable for each other.展开更多
The contents of indapamide and related impurities in generic indapamide sustained-release tablets were simultaneously detected by a single-run high performance liquid chromatography equipped with photodiode array dete...The contents of indapamide and related impurities in generic indapamide sustained-release tablets were simultaneously detected by a single-run high performance liquid chromatography equipped with photodiode array detector(HPLC-PDA)method for the quality control in this paper.The results showed the method had a good selectivity and was validated through linearity,limits of detection and quantification,recovery,and precision.The linear ranges of indapamide,2-methyl-1-nitroso-2,3-dihydro-1H-indole(impurity A,ImA),4-chloro-N-(2-methyl-1H-indol-1-yl)-3-sulphamoyl-benzamide(impurity B,ImB)and 4-chloro-3-sulfamoylbenzoic acid(impurity 1,Im1)were 0.028-1.80μg/mL(R=0.99995),0.060-1.20μg/mL(R=0.9996),0.0324-1.20μg/mL(R=0.99985)and 0.060-1.20μg/mL(R=0.9997)with detection limits of 0.0093,0.012,0.012 and 0.006μg/mL,respectively.ImA and Im1 were not detectable in the generic drug.The content of indapamide was 96.7%of the labeled amount with a relative standard deviation(RSD)of 1.30%,and the percentage of ImB relative to the labeled amounts of indapamide was 0.106%with an RSD of 1.82%.The content of other unspecified impurities all met the reference quality standards.The results provided references for the quality control and the quality standard study of generic indapamide sustained-release tablets.展开更多
文摘A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.
基金the financial support by the Food Safety Fund of General Administration of Quality Supervision,Inspection and Quarantine of Chinathe Key Scientific Program of National Institute of Metrology of China(Nos.ASPAQ201010 and AJDYX1116)
文摘An efficient and accurate analytical method was developed for the simultaneous determination of 20 synthetic food additives, including three sweeteners,seven food colorants,nine synthetic preservatives and caffeine,by high performance liquid chromatography (HPLC) with photodiode array detector(PDA).This method permits the detection of food additives at very low concentrations(0.005-0.150μg/mL).The applicability was verified by the determination of food additives present in various foodstuffs.
文摘A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consists of isocratic eluation with a mixture of 60% buffer (10 mM sodium dihyrogenphosphate-10 mM sodium dodecyl sulphate) and 40% acetonitrile with final pH 7.0 with flow rate of 1.0 mL/min on a Kromasil~ Akzo Nobel RP-18 (4.6 mm ID ~ 250 mm, 5 ~tm) column at an ambient temperature. Photo diode array detection was performed in program mode at 234 rim. The analyte and diazepam as internal standard (IS) were extracted from plasma using 10% trichloroacetic acid. The assay was linear over the therapeutic concentration range of 20-2,500 ng/mL for metformin HCI with correlation coefficient of r = 0.9999. Limit of quantitation was 20 ng/mL. The results obtained for intraJinter day accuracy and precision complied very well with the generally accepted criteria for bio-analytical assay. The method was applied to bioequivalence (BE) study of metformin HCI in healthy Indonesian volunteers after treatment with 750 mg XR metformin HCI. This BE study shows that the two formulations are equivalent so that they were therapeutically interchangeable for each other.
基金the Natural Science Foundation of Anhui Province,China(11040606M41)the Natural Science Project in Colleges and Universities of Anhui Province,China(kj2016A683)the Natural Science Project of Huangshan University,China(hxkt20190042,xdhz202007)。
文摘The contents of indapamide and related impurities in generic indapamide sustained-release tablets were simultaneously detected by a single-run high performance liquid chromatography equipped with photodiode array detector(HPLC-PDA)method for the quality control in this paper.The results showed the method had a good selectivity and was validated through linearity,limits of detection and quantification,recovery,and precision.The linear ranges of indapamide,2-methyl-1-nitroso-2,3-dihydro-1H-indole(impurity A,ImA),4-chloro-N-(2-methyl-1H-indol-1-yl)-3-sulphamoyl-benzamide(impurity B,ImB)and 4-chloro-3-sulfamoylbenzoic acid(impurity 1,Im1)were 0.028-1.80μg/mL(R=0.99995),0.060-1.20μg/mL(R=0.9996),0.0324-1.20μg/mL(R=0.99985)and 0.060-1.20μg/mL(R=0.9997)with detection limits of 0.0093,0.012,0.012 and 0.006μg/mL,respectively.ImA and Im1 were not detectable in the generic drug.The content of indapamide was 96.7%of the labeled amount with a relative standard deviation(RSD)of 1.30%,and the percentage of ImB relative to the labeled amounts of indapamide was 0.106%with an RSD of 1.82%.The content of other unspecified impurities all met the reference quality standards.The results provided references for the quality control and the quality standard study of generic indapamide sustained-release tablets.