期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Volumetric assessment of hepatic grafts using a light detection and ranging system for 3D scanning:Preliminary data
1
作者 Georgios Katsanos Konstantina-Eleni Karakasi +4 位作者 Ion-Anastasios Karolos Athanasios Kofinas Nikolaos Antoniadis Vassilios Tsioukas Georgios Tsoulfas 《World Journal of Hepatology》 2022年第7期1504-1511,共8页
BACKGROUND Liver transplantation has evolved into a safe life-saving operation and remains the golden standard in the treatment of end stage liver disease.The main limiting factor in the application of liver transplan... BACKGROUND Liver transplantation has evolved into a safe life-saving operation and remains the golden standard in the treatment of end stage liver disease.The main limiting factor in the application of liver transplantation is graft shortage.Many strategies have been developed in order to alleviate graft shortage,such as living donor partial liver transplantation and split liver transplantation for adult and pediatric patients.In these strategies,liver volume assessment is of paramount importance,as size mismatch can have severe consequences in the success of liver transplantation.AIM To evaluate the safety,feasibility,and accuracy of light detection and ranging(LIDAR)3D photography in the prediction of whole liver graft volume and mass.METHODS Seven liver grafts procured for orthotopic liver transplantation from brain deceased donors were prospectively measured with an LIDAR handheld camera and their mass was calculated and compared to their actual weight.RESULTS The mean error of all measurements was 17.03 g(range 3.56-59.33 g).Statistical analysis of the data yielded a Pearson correlation coefficient index of 0.9968,indicating a strong correlation between the values and a Student’s t-test P value of 0.26.Mean accuracy of the measurements was calculated at 97.88%.CONCLUSION Our preliminary data indicate that LIDAR scanning of liver grafts is a safe,cost-effective,and feasible method of ex vivo determination of whole liver volume and mass.More data are needed to determine the precision and accuracy of this method. 展开更多
关键词 Light detection and ranging Graft volume 3dscan Ex vivo volumetry Liver grafts
暂未订购
用好监测与测量接收机ESMB的三种扫描模式
2
作者 朱斌 《中国无线电》 2009年第1期62-66,共5页
德国罗德与施瓦茨(以下简称R&S)公司的监测与测量接收机ESMB目前在我国无线电监测领域具有一定的运用,通过对其三种扫描模式的分析,说明这三种扫描模式(FSCAN、MSCAN、DSCAN)在使用中应注意的问题,从而提高监测效率和监测结果的准... 德国罗德与施瓦茨(以下简称R&S)公司的监测与测量接收机ESMB目前在我国无线电监测领域具有一定的运用,通过对其三种扫描模式的分析,说明这三种扫描模式(FSCAN、MSCAN、DSCAN)在使用中应注意的问题,从而提高监测效率和监测结果的准确性。 展开更多
关键词 罗德与施瓦茨 ESMB FSCAN MSCAN dscan
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部