Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations ma...Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations may occur during the transient process due to sudden changes in real power of such WTs.To address this issue,a current feedforward control strategy is proposed for PMSG-based WTs to reduce DC-link voltage fluctuations when the WTs are providing frequency support under grid frequency deviations.Meanwhile,the desired frequency support capability of the PMSG-based WTs can be ensured.Simulation results verify the rationality of the analysis and the effectiveness of the proposed control method.展开更多
Capacitors are widely used in pulsed magnet power supplies to reduce ripple voltage,store energy,and decrease power variation.In this study,DC-link capacitors in pulsed power supplies were investigated.By deriving an ...Capacitors are widely used in pulsed magnet power supplies to reduce ripple voltage,store energy,and decrease power variation.In this study,DC-link capacitors in pulsed power supplies were investigated.By deriving an analytical method for the capacitor current on the H-bridge topology side,the root-mean-square value of the capacitor current was calculated,which helps in selecting the DC-link capacitors.The proposed method solves this problem quickly and with high accuracy.The current reconstruction of the DC-link capacitor is proposed to avoid structural damage in the capacitor’s current measurement,and the capacitor’s hotspot temperature and temperature rise are calculated using the FFT transform.The test results showed that the error between the calculated and measured temperature increases was within 1.5℃.Finally,the lifetime of DC-link capacitors was predicted based on Monte Carlo analysis.The proposed method can evaluate the reliability of DC-link capacitors in a non-isolated switching pulsed power supply for accelerators and is also applicable to film capacitors.展开更多
The transient behavior of DC-link voltage(DCV)significantly affects the low-voltage ride-through for phase-locked loop(PLL)-based grid-connected doubly-fed induction generator(DFIG)systems.This study investigates the ...The transient behavior of DC-link voltage(DCV)significantly affects the low-voltage ride-through for phase-locked loop(PLL)-based grid-connected doubly-fed induction generator(DFIG)systems.This study investigates the DCV transient behavior of a PLL-based DFIG system under asymmetrical grid faults.First,by considering the coupling characteristics of positive and negative sequence(PNS)components,a nonlinear largesignal model of DCV is developed.Furthermore,the transient characteristics of DCV under varying parameters are analyzed using phase trajectory diagrams.In addition,the transient stability(TS)mechanism of DCV during asymmetrical faults is examined through an en-ergy function approach.The analysis indicates that the transient instability of DCV is primarily associated with the control characteristics of PNS PLLs,while the TS level of DCV is mainly determined by the power coordination control between the rotor side converter and grid side converter.Moreover,a coordinated control strategy is proposed to enhance the TS of DCV under asymmet-rical grid faults.Finally,both simulation and experimental results are presented to validate the theoretical analysis and the effectiveness of the proposed strategy.展开更多
This paper proposes an indirect power control of doubly fed induction generator (DFIG) with the rotor connected to the electric grid through a back-to-back pulse width modulation (PWM) converter for variable speed...This paper proposes an indirect power control of doubly fed induction generator (DFIG) with the rotor connected to the electric grid through a back-to-back pulse width modulation (PWM) converter for variable speed wind power generation. Appropriate state space model of the DFIG is deduced. An original control strategy based on a variable structure control theory, also called sliding mode control, is applied to achieve the control of the active and reactive power exchanged between the stator of the DFIG and the grid. A proportional-integral-(P1) controller is used to keep the DC-link voltage constant for a back-to-back PWM converter. Simulations are conducted for validation of the digital controller operation using Matlab/Simulink software.展开更多
基金This work is jointly supported by the National Key R&D Programme of China(No.2017YFB0902000)the National Natural Science Foundation of China(No.U1766206)the Science and Technology Programme of the State Grid Corporation(No.52110418000P).
文摘Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations may occur during the transient process due to sudden changes in real power of such WTs.To address this issue,a current feedforward control strategy is proposed for PMSG-based WTs to reduce DC-link voltage fluctuations when the WTs are providing frequency support under grid frequency deviations.Meanwhile,the desired frequency support capability of the PMSG-based WTs can be ensured.Simulation results verify the rationality of the analysis and the effectiveness of the proposed control method.
基金supported by the National Key Research and Development Program of China(No.2019YFA0405402).
文摘Capacitors are widely used in pulsed magnet power supplies to reduce ripple voltage,store energy,and decrease power variation.In this study,DC-link capacitors in pulsed power supplies were investigated.By deriving an analytical method for the capacitor current on the H-bridge topology side,the root-mean-square value of the capacitor current was calculated,which helps in selecting the DC-link capacitors.The proposed method solves this problem quickly and with high accuracy.The current reconstruction of the DC-link capacitor is proposed to avoid structural damage in the capacitor’s current measurement,and the capacitor’s hotspot temperature and temperature rise are calculated using the FFT transform.The test results showed that the error between the calculated and measured temperature increases was within 1.5℃.Finally,the lifetime of DC-link capacitors was predicted based on Monte Carlo analysis.The proposed method can evaluate the reliability of DC-link capacitors in a non-isolated switching pulsed power supply for accelerators and is also applicable to film capacitors.
基金supported in part by Smart Grid-National Science and Technology Major Project(No.2024ZD0801400)Science and technology projects of State Grid Corporation of China(No.52272224000V).
文摘The transient behavior of DC-link voltage(DCV)significantly affects the low-voltage ride-through for phase-locked loop(PLL)-based grid-connected doubly-fed induction generator(DFIG)systems.This study investigates the DCV transient behavior of a PLL-based DFIG system under asymmetrical grid faults.First,by considering the coupling characteristics of positive and negative sequence(PNS)components,a nonlinear largesignal model of DCV is developed.Furthermore,the transient characteristics of DCV under varying parameters are analyzed using phase trajectory diagrams.In addition,the transient stability(TS)mechanism of DCV during asymmetrical faults is examined through an en-ergy function approach.The analysis indicates that the transient instability of DCV is primarily associated with the control characteristics of PNS PLLs,while the TS level of DCV is mainly determined by the power coordination control between the rotor side converter and grid side converter.Moreover,a coordinated control strategy is proposed to enhance the TS of DCV under asymmet-rical grid faults.Finally,both simulation and experimental results are presented to validate the theoretical analysis and the effectiveness of the proposed strategy.
文摘This paper proposes an indirect power control of doubly fed induction generator (DFIG) with the rotor connected to the electric grid through a back-to-back pulse width modulation (PWM) converter for variable speed wind power generation. Appropriate state space model of the DFIG is deduced. An original control strategy based on a variable structure control theory, also called sliding mode control, is applied to achieve the control of the active and reactive power exchanged between the stator of the DFIG and the grid. A proportional-integral-(P1) controller is used to keep the DC-link voltage constant for a back-to-back PWM converter. Simulations are conducted for validation of the digital controller operation using Matlab/Simulink software.