To enhance power flow regulation in scenarios involving large-scale renewable energy transmission via high-voltage direct current(HVDC)links and multi-infeed DC systems in load-center regions,this paper proposes a hyb...To enhance power flow regulation in scenarios involving large-scale renewable energy transmission via high-voltage direct current(HVDC)links and multi-infeed DC systems in load-center regions,this paper proposes a hybrid modular multilevel converter–capacitor-commutated line-commutated converter(MMC-CLCC)HVDC transmission system and its corresponding control strategy.First,the system topology is constructed,and a submodule configuration method for the MMC—combining full-bridge submodules(FBSMs)and half-bridge submodules(HBSMs)—is proposed to enable direct power flow reversal.Second,a hierarchical control strategy is introduced,includingMMCvoltage control,CLCC current control,and a coordinationmechanism,along with the derivation of the hybrid system’s power flow reversal characteristics.Third,leveraging the CLCC’s fast current regulation and theMMC’s negative voltage control capability,a coordinated power flow reversal control strategy is developed.Finally,an 800 kV MMC-CLCC hybrid HVDC system is modeled in PSCAD/EMTDC to validate the power flow reversal performance under a high proportion of full-bridge submodule configuration.Results demonstrate that the proposed control strategy enables rapid(1-s transition)and smooth switching of bidirectional power flow without modifying the structure of primary equipment:the transient fluctuation ofDC voltage from the rated value(UdcN)to themaximumreverse voltage(-kUdcN)is less than 5%;the DC current strictly follows the preset characteristic curve with a deviation of≤3%;the active power reverses continuously,and the system maintains stable operation throughout the reversal process.展开更多
In modern ZnO varistors,traditional aging mechanisms based on increased power consumption are no longer relevant due to reduced power consumption during DC aging.Prolonged exposure to both AC and DC voltages results i...In modern ZnO varistors,traditional aging mechanisms based on increased power consumption are no longer relevant due to reduced power consumption during DC aging.Prolonged exposure to both AC and DC voltages results in increased leakage current,decreased breakdown voltage,and lower nonlinearity,ultimately compromising their protective performance.To investigate the evolution in electrical properties during DC aging,this work developed a finite element model based on Voronoi networks and conducted accelerated aging tests on commercial varistors.Throughout the aging process,current-voltage characteristics and Schottky barrier parameters were measured and analyzed.The results indicate that when subjected to constant voltage,current flows through regions with larger grain sizes,forming discharge channels.As aging progresses,the current focus increases on these channels,leading to a decline in the varistor’s overall performance.Furthermore,analysis of the Schottky barrier parameters shows that the changes in electrical performance during aging are non-monotonic.These findings offer theoretical support for understanding the aging mechanisms and condition assessment of modern stable ZnO varistors.展开更多
[Objectives]To assess the effects of endophytic bacteria on the growth,antioxidant responses,and the production of key secondary metabolites in Emilia prenanthoidea DC.[Methods]Three endophytic strains(H1,H2,L1)were i...[Objectives]To assess the effects of endophytic bacteria on the growth,antioxidant responses,and the production of key secondary metabolites in Emilia prenanthoidea DC.[Methods]Three endophytic strains(H1,H2,L1)were inoculated onto tissue-cultured seedlings and cultivated for 20 d under greenhouse conditions.Growth traits,reactive oxygen species(ROS)indicators,antioxidant enzyme activities,and the content of chlorogenic acid and quercetin were analyzed using one-way ANOVA followed by Tukey s test.[Results]Bacterial inoculation significantly enhanced plant performance.Treatment H2 increased plant height by 27%,chlorophyll content by 73%,and fresh weight by 31%.Levels of ROS(O^(-)_(2),H_(2)O_(2))and MDA decreased markedly,whereas the activities of POD and CAT increased.Additionally,the content of chlorogenic acid and quercetin increased by up to 67%and 64%,respectively,with both H2 and L1 treatments showing the most pronounced effects.[Conclusions]Endophytic bacteria markedly improve growth,redox balance,and phenolic accumulation in E.prenanthoidea.Strain H2 represents a promising bioinoculant for improving the medicinal quality of this species.展开更多
Motivation.As artificial intelligence(AI)workloads escalate exponentially,ultra-thin,high-efficiency voltage regulator modules(VRMs)with exceptional power density become essential for backside-mounted configurations[1...Motivation.As artificial intelligence(AI)workloads escalate exponentially,ultra-thin,high-efficiency voltage regulator modules(VRMs)with exceptional power density become essential for backside-mounted configurations[1].Thus,highdensity multiphase DC−DC converters are pivotal for implementing vertical power delivery(VPD)architectures in XPU platforms.Strategically positioning these converters beneath processors and maximizing spatial utilization enables core rail currents exceeding 2 kA while significantly reducing the power distribution network(PDN)losses compared to conventional solutions.The VPD configuration elevates system-level energy efficiency with>100 W power saving per processor,yielding megawatt-scale savings in a datacenter that uses~100000 processors.The synergy of 48 V power conversion architectures and advanced packaging techniques enables the industry’s commitment to balancing computational demands with CO_(2)emission reduction and environmental sustainability.展开更多
Given the grave local and international network security landscape,a national strategic level analysis indicates that the modernization and advancement within the Industry 4.0 era are closely correlated with overall c...Given the grave local and international network security landscape,a national strategic level analysis indicates that the modernization and advancement within the Industry 4.0 era are closely correlated with overall competitive strength.Consequently,China proposed a strategy for the integration of industrialization and informatization,optimizing and adjusting its industrial structure to swiftly achieve transformation and upgrading in the Industry 4.0 era,thereby enhancing the sophistication of intelligent industrial control systems.The distributed control system in a nuclear power plant functions as an industrial control system,overseeing the operational status of the physical process.Its ability to ensure safe and reliable operation is directly linked to nuclear safety and the cybersecurity of the facility.The management of network security in distributed control systems(DCS)is crucial for achieving this objective.Due to the varying network settings and parameters of the DCS implemented in each nuclear power plant,the network security status of the system sometimes diverges from expectations.During system operation,it will undoubtedly encounter network security issues.Consequently,nuclear power plants utilize the technical criteria outlined in GB/T 22239 to formulate a network security management program aimed at enhancing the operational security of DCS within these facilities.This study utilizes existing network security regulations and standards as a reference to analyze the network security control standards based on the nuclear power plant’s control system.It delineates the fundamental requirements for network security management,facilitating integration with the entire life cycle of the research,development,and application of the nuclear power plant’s distributed control system,thereby establishing a network security management methodology that satisfies the control requirements of the nuclear power plant.Initially,it presents DCS and network security management,outlines current domestic and international network security legislation and standards,and specifies the standards pertinent to the administration of DCS in nuclear power plants.Secondly,the design of network security management for DCS is executed in conjunction with the specific context of nuclear power plants.This encompasses the deployment of network security apparatus,validation of the network security management strategy,and optimization adjustments.Consequently,recommendations beneficial to the network security management of nuclear power plants are compiled,aimed at establishing a management system and incorporating the concept of full life cycle management,which is predicated on system requirements,system design,and both software and hardware considerations.Conversely,it presents the notion of comprehensive life cycle management and suggests network security management strategies encompassing system requirements,system architecture,detailed hardware and software design and implementation,procurement,internal system integration,system validation and acceptance testing,system installation,operational maintenance,system modifications,and decommissioning.We will consistently enhance the performance and functionality of DCS in nuclear power plants,establish a safe and secure operational environment,and thereby facilitate the implementation of DCS in nuclear facilities while ensuring robust network security in the future.展开更多
In wind and solar renewable-dominant hybrid alternating current/direct current(AC/DC)power systems,the active power of high-voltage direct current(HVDC)system is significantly limited by the security and stability eve...In wind and solar renewable-dominant hybrid alternating current/direct current(AC/DC)power systems,the active power of high-voltage direct current(HVDC)system is significantly limited by the security and stability events caused by cascading failures.To identify critical lines in cascading failures,a rapid risk assessment method is proposed based on the gradient boosting decision tree(GBDT)and frequent pat-tern growth(FP-Growth)algorithms.First,security and stability events triggered by cascading failures are analyzed to explain the impact of cascading failures on the maximum DC power.Then,a cascading failure risk index is defined,focusing on the DC power being limited.To handle the strong nonlinear relationship between the maximum DC power and cascading failures,a GBDT with an update strategy is utilized to rapidly predict the maximum DC power under uncertain operating conditions.Finally,the FP-Growth algorithm is improved to mine frequent patterns in cascading failures.The importance index for each fault in a frequent pattern is defined by evaluating its impact on cascading failures,enabling the identification of critical lines.Simulation results of a modified Ningxia–Shandong hybrid AC/DC system in China demonstrate that the proposed method can rapidly assess the risk of cascading failures and effectively identify critical lines.展开更多
基金supported by Science and Technology Project of the headquarters of the State Grid Corporation of China(No.5500-202324492A-3-2-ZN).
文摘To enhance power flow regulation in scenarios involving large-scale renewable energy transmission via high-voltage direct current(HVDC)links and multi-infeed DC systems in load-center regions,this paper proposes a hybrid modular multilevel converter–capacitor-commutated line-commutated converter(MMC-CLCC)HVDC transmission system and its corresponding control strategy.First,the system topology is constructed,and a submodule configuration method for the MMC—combining full-bridge submodules(FBSMs)and half-bridge submodules(HBSMs)—is proposed to enable direct power flow reversal.Second,a hierarchical control strategy is introduced,includingMMCvoltage control,CLCC current control,and a coordinationmechanism,along with the derivation of the hybrid system’s power flow reversal characteristics.Third,leveraging the CLCC’s fast current regulation and theMMC’s negative voltage control capability,a coordinated power flow reversal control strategy is developed.Finally,an 800 kV MMC-CLCC hybrid HVDC system is modeled in PSCAD/EMTDC to validate the power flow reversal performance under a high proportion of full-bridge submodule configuration.Results demonstrate that the proposed control strategy enables rapid(1-s transition)and smooth switching of bidirectional power flow without modifying the structure of primary equipment:the transient fluctuation ofDC voltage from the rated value(UdcN)to themaximumreverse voltage(-kUdcN)is less than 5%;the DC current strictly follows the preset characteristic curve with a deviation of≤3%;the active power reverses continuously,and the system maintains stable operation throughout the reversal process.
文摘In modern ZnO varistors,traditional aging mechanisms based on increased power consumption are no longer relevant due to reduced power consumption during DC aging.Prolonged exposure to both AC and DC voltages results in increased leakage current,decreased breakdown voltage,and lower nonlinearity,ultimately compromising their protective performance.To investigate the evolution in electrical properties during DC aging,this work developed a finite element model based on Voronoi networks and conducted accelerated aging tests on commercial varistors.Throughout the aging process,current-voltage characteristics and Schottky barrier parameters were measured and analyzed.The results indicate that when subjected to constant voltage,current flows through regions with larger grain sizes,forming discharge channels.As aging progresses,the current focus increases on these channels,leading to a decline in the varistor’s overall performance.Furthermore,analysis of the Schottky barrier parameters shows that the changes in electrical performance during aging are non-monotonic.These findings offer theoretical support for understanding the aging mechanisms and condition assessment of modern stable ZnO varistors.
文摘[Objectives]To assess the effects of endophytic bacteria on the growth,antioxidant responses,and the production of key secondary metabolites in Emilia prenanthoidea DC.[Methods]Three endophytic strains(H1,H2,L1)were inoculated onto tissue-cultured seedlings and cultivated for 20 d under greenhouse conditions.Growth traits,reactive oxygen species(ROS)indicators,antioxidant enzyme activities,and the content of chlorogenic acid and quercetin were analyzed using one-way ANOVA followed by Tukey s test.[Results]Bacterial inoculation significantly enhanced plant performance.Treatment H2 increased plant height by 27%,chlorophyll content by 73%,and fresh weight by 31%.Levels of ROS(O^(-)_(2),H_(2)O_(2))and MDA decreased markedly,whereas the activities of POD and CAT increased.Additionally,the content of chlorogenic acid and quercetin increased by up to 67%and 64%,respectively,with both H2 and L1 treatments showing the most pronounced effects.[Conclusions]Endophytic bacteria markedly improve growth,redox balance,and phenolic accumulation in E.prenanthoidea.Strain H2 represents a promising bioinoculant for improving the medicinal quality of this species.
文摘Motivation.As artificial intelligence(AI)workloads escalate exponentially,ultra-thin,high-efficiency voltage regulator modules(VRMs)with exceptional power density become essential for backside-mounted configurations[1].Thus,highdensity multiphase DC−DC converters are pivotal for implementing vertical power delivery(VPD)architectures in XPU platforms.Strategically positioning these converters beneath processors and maximizing spatial utilization enables core rail currents exceeding 2 kA while significantly reducing the power distribution network(PDN)losses compared to conventional solutions.The VPD configuration elevates system-level energy efficiency with>100 W power saving per processor,yielding megawatt-scale savings in a datacenter that uses~100000 processors.The synergy of 48 V power conversion architectures and advanced packaging techniques enables the industry’s commitment to balancing computational demands with CO_(2)emission reduction and environmental sustainability.
文摘Given the grave local and international network security landscape,a national strategic level analysis indicates that the modernization and advancement within the Industry 4.0 era are closely correlated with overall competitive strength.Consequently,China proposed a strategy for the integration of industrialization and informatization,optimizing and adjusting its industrial structure to swiftly achieve transformation and upgrading in the Industry 4.0 era,thereby enhancing the sophistication of intelligent industrial control systems.The distributed control system in a nuclear power plant functions as an industrial control system,overseeing the operational status of the physical process.Its ability to ensure safe and reliable operation is directly linked to nuclear safety and the cybersecurity of the facility.The management of network security in distributed control systems(DCS)is crucial for achieving this objective.Due to the varying network settings and parameters of the DCS implemented in each nuclear power plant,the network security status of the system sometimes diverges from expectations.During system operation,it will undoubtedly encounter network security issues.Consequently,nuclear power plants utilize the technical criteria outlined in GB/T 22239 to formulate a network security management program aimed at enhancing the operational security of DCS within these facilities.This study utilizes existing network security regulations and standards as a reference to analyze the network security control standards based on the nuclear power plant’s control system.It delineates the fundamental requirements for network security management,facilitating integration with the entire life cycle of the research,development,and application of the nuclear power plant’s distributed control system,thereby establishing a network security management methodology that satisfies the control requirements of the nuclear power plant.Initially,it presents DCS and network security management,outlines current domestic and international network security legislation and standards,and specifies the standards pertinent to the administration of DCS in nuclear power plants.Secondly,the design of network security management for DCS is executed in conjunction with the specific context of nuclear power plants.This encompasses the deployment of network security apparatus,validation of the network security management strategy,and optimization adjustments.Consequently,recommendations beneficial to the network security management of nuclear power plants are compiled,aimed at establishing a management system and incorporating the concept of full life cycle management,which is predicated on system requirements,system design,and both software and hardware considerations.Conversely,it presents the notion of comprehensive life cycle management and suggests network security management strategies encompassing system requirements,system architecture,detailed hardware and software design and implementation,procurement,internal system integration,system validation and acceptance testing,system installation,operational maintenance,system modifications,and decommissioning.We will consistently enhance the performance and functionality of DCS in nuclear power plants,establish a safe and secure operational environment,and thereby facilitate the implementation of DCS in nuclear facilities while ensuring robust network security in the future.
基金supported by the National Key Research and Development Program of China"Key technologies for system stability and HVDC transmission of large-scale renewable energy generation base without conventional power support(2022YFB2402700)"the project of the State Grid Corporation of China(52272222001J).
文摘In wind and solar renewable-dominant hybrid alternating current/direct current(AC/DC)power systems,the active power of high-voltage direct current(HVDC)system is significantly limited by the security and stability events caused by cascading failures.To identify critical lines in cascading failures,a rapid risk assessment method is proposed based on the gradient boosting decision tree(GBDT)and frequent pat-tern growth(FP-Growth)algorithms.First,security and stability events triggered by cascading failures are analyzed to explain the impact of cascading failures on the maximum DC power.Then,a cascading failure risk index is defined,focusing on the DC power being limited.To handle the strong nonlinear relationship between the maximum DC power and cascading failures,a GBDT with an update strategy is utilized to rapidly predict the maximum DC power under uncertain operating conditions.Finally,the FP-Growth algorithm is improved to mine frequent patterns in cascading failures.The importance index for each fault in a frequent pattern is defined by evaluating its impact on cascading failures,enabling the identification of critical lines.Simulation results of a modified Ningxia–Shandong hybrid AC/DC system in China demonstrate that the proposed method can rapidly assess the risk of cascading failures and effectively identify critical lines.