期刊文献+
共找到29,463篇文章
< 1 2 250 >
每页显示 20 50 100
Novel Double-Damped Tuned AC Filters in HVDC Systems 被引量:1
1
作者 Rana Shaheer Mehmood Asif Hussain +1 位作者 Usman Ali Muhammad Tariq Mahmood 《Computers, Materials & Continua》 SCIE EI 2023年第4期1467-1482,共16页
This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of i... This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of improved performance of HVDC systems in terms of betterpower quality, high power factor, and lower total harmonic distortion (THD).The system under analysis consists of an 878 km long HVDC transmissionline connecting converter stations at Matiari and Lahore, two major cities inPakistan. The main focus of this research is to design a novel AC filter usingthe equivalent impedance method of two single-tuned and double-dampedtuned AC filters. Additionally, the impact of the damping resistor on the ACchannel is examined. TheTHDof theHVDCsystem with and without currentAC filters was also compared in this research and a double-damped tuned ACfilter was proposed. The results of the simulation represent that the proposeddouble-damped tuned AC filter is far smaller in size, offers better powerquality, and has a much lower THD compared to the AC filters currently inplace in the converter station. The simulation analysis was carried out utilizingpower systems computer-aided design (PSCAD) software. 展开更多
关键词 Double-damped tuned AC filters HARMONICS high voltage dc systems long distance transmission power quality total harmonic distortion
在线阅读 下载PDF
Study on the Application of UHVDC Hierarchical Connection Mode to Multi-infeed HVDC System 被引量:81
2
作者 LIU Zhenya QIN Xiaohui +1 位作者 ZHAO Liang ZHAO Qingbo 《中国电机工程学报》 EI CSCD 北大核心 2013年第10期I0001-I0026,25,共26页
随着我国特高压交直流技术的广泛应用,多馈入直流集中落入受端负荷中心将是未来我国电网发展所面临的重要问题。为从电网结构上有效解决多馈入直流系统的问题,提出一种特高压直流分层接入交流电网的方式。研究分层接入方式直流多馈入... 随着我国特高压交直流技术的广泛应用,多馈入直流集中落入受端负荷中心将是未来我国电网发展所面临的重要问题。为从电网结构上有效解决多馈入直流系统的问题,提出一种特高压直流分层接入交流电网的方式。研究分层接入方式直流多馈入短路比计算方法的适用性,从理论上对比特高压直流不同接入方式下多馈入直流电网的系统特性,证明特高压直流分层接入方式有助于提高多馈入直流系统的电压支撑能力,引导潮流在1000kV与500kV层级间合理分布。结合国家电网规划,仿真验证了特高压直流分层接入方式的优势。 展开更多
关键词 多馈入直流输电系统 特高压直流输电 连接模式 应用 输电技术 电网发展 负荷中心 电网结构
原文传递
Engineering practices for the integration of large-scale renewable energy VSC-HVDC systems 被引量:8
3
作者 Yan Li Hongzhi Liu +1 位作者 Xiaojie Fan Xinshou Tian 《Global Energy Interconnection》 2020年第2期149-157,共9页
With the continuous development of power electronic devices,intelligent control systems,and other technologies,the voltage level and transmission capacity of voltage source converter (VSC)-high-voltage direct current ... With the continuous development of power electronic devices,intelligent control systems,and other technologies,the voltage level and transmission capacity of voltage source converter (VSC)-high-voltage direct current (HVDC) technology will continue to increase,while the system losses and costs will gradually decrease.Therefore,it can be foreseen that VSC-HVDC transmission technology will be more widely applied in future large-scale renewable energy development projects.Adopting VSC-HVDC transmission technology can be used to overcome issues encountered by large-scale renewable energy transmission and integration projects,such as a weak local power grid,lack of support for synchronous power supply,and insufficient accommodation capacity.However,this solution also faces many technical challenges because of the differences between renewable energy and traditional synchronous power generation systems.Based on actual engineering practices that are used worldwide,this article analyzes the technical challenges encountered by integrating large-scale renewable energy systems that adopt the use of VSC-HVDC technology,while aiming to provide support for future research and engineering projects related to VSC-HVDC-based large-scale renewable energy integration projects. 展开更多
关键词 VSC-HVdc Renewable energy integration dc grid Engineering practice
在线阅读 下载PDF
Studies of commutation failures in hybrid LCC/MMC HVDC systems 被引量:11
4
作者 Gen Li Ting An +4 位作者 Jun Liang Wei Liu Tibin Joseph Jingjing Lu Yuanliang Lan 《Global Energy Interconnection》 2020年第3期193-204,共12页
A hybrid of line commutated converters(LCCs)and modular multi-level converters(MMCs)can provide the advantages of both the technologies.However,the commutation failure still exists if the LCC operates as an inverter i... A hybrid of line commutated converters(LCCs)and modular multi-level converters(MMCs)can provide the advantages of both the technologies.However,the commutation failure still exists if the LCC operates as an inverter in a hybrid LCC/MMC system.In this paper,the system behavior during a commutation failure is investigated.Both halfbridge and full-bridge MMCs are considered.Control strategies are examined through simulations conducted in PSCAD/EMTDC.Additionally,commutation failure protection strategies for multi-terminal hybrid LCC/MMC systems with AC and DC circuit breakers are studied.This paper can contribute to the protection design of future hybrid LCC/MMC systems against commutation failures. 展开更多
关键词 LCC HVdc MMC HVdc Modular multilevel converter Hybrid LCC/MMC Commutation failure multi-terminal dc Fault protection
在线阅读 下载PDF
DC System Modeling and AC/DC System Harmonic Calculation under Asymmetric Faults 被引量:1
5
作者 Haifeng Li Junlei Liu +1 位作者 Fengjiao Wang Gang Wang 《Energy and Power Engineering》 2013年第4期1202-1208,共7页
The accurate DC system model is the key to fault analysis and harmonic calculation of AC/DC system. In this paper, a frequency domain analysis model of DC system is established, and based on it a unified fundamental f... The accurate DC system model is the key to fault analysis and harmonic calculation of AC/DC system. In this paper, a frequency domain analysis model of DC system is established, and based on it a unified fundamental frequency and harmonic iterative calculation method is proposed. The DC system model is derived considering the dynamic switching characteristic of converter and the steady-state response features of dc control system synchronously. And the proposed harmonic calculation method fully considers the AC/DC harmonic interaction and fault interaction under AC asymmetric fault condition. The method is used to the harmonic analysis and calculation of CIGRE HVDC system. Compared with those obtained by simulation using PSCAD/EMTDC software, the results show that the proposed model and method are accurate and effective, and provides the analysis basis of harmonic suppression, filter configuration and protection analysis in AC/DC system. 展开更多
关键词 dc system Model HARMONIC CALCULATION SWITCHING FUNCTION ASYMMETRIC FAULTS
在线阅读 下载PDF
Transient characteristics verification method for DC transformer used in flexible HVDC system 被引量:2
6
作者 Qi Nie Haoliang Hu +3 位作者 Dengyun Li Boyang Liu He Li Qianzhu Xiong 《Global Energy Interconnection》 2019年第2期180-187,共8页
Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider band... Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider bandwidth requirements of the control and protection signal, and to eventually suppress the large transient fault current. In this study, a transient characteristics verification method is proposed for transient characteristics verification of a DC transformer used in a flexible HVDC system based on resampling technology and LabVIEW measurement technology after analyzing the key technology for transient characteristics verification of a DC transformer. A laboratory experiment for the transient characteristics of a full-fiber electronic DC transformer is conducted, and experimental results show that such verification method can be employed for frequency response and step response verification of a DC transformer at 10% of the rated voltage and current, and can eventually improve the screening of a DC transformer. 展开更多
关键词 dc TRANSFORMER STEP response TRANSIENT CHARACTERISTIC RESAMPLING technology Verification method
在线阅读 下载PDF
Overview of development, design, testing and application of compact gas-insulated DC systems up to ±550 kV 被引量:3
7
作者 Maria Kosse Dejun Li +1 位作者 Karsten Juhre Mark Kuschel 《Global Energy Interconnection》 2019年第6期568-578,共11页
The development of high-voltage direct current gas-insulated switchgear assemblies(DC GIS)of rated voltages up to±550 kV has been completed.DC GIS provide a compact technical solution with a high functional densi... The development of high-voltage direct current gas-insulated switchgear assemblies(DC GIS)of rated voltages up to±550 kV has been completed.DC GIS provide a compact technical solution with a high functional density,optimized for projects with limited space as in offshore HVDC converter platforms,onshore HVDC converter stations and transition stations between different transmission media.Up to now,no standards for testing of gas-insulated DC systems are available,although pre-standardization work is in progress within CIGRE.Some tests can be performed as required in AC GIS standards.Special aspects of DC voltage stress,like the electric field distribution of insulators influenced by the accumulation of electrical charge carriers and the operation-related inhomogeneous temperature distribution,must be considered by additional electric and thermoelectric tests.For DC GIS,the experience of long-term performance is limited today.Although ageing is expected to be of lower importance,tests are recommended.This contribution summarizes the physical and technical background to design and develop compact DC switchgear assemblies using gas-insulated technology.It explains the developed modules of the substation and gives an overview of the performed tests.Furthermore,it provides an insight in the on-going standardization activities and describes applications in converter and transition stations,showing its space-saving characteristics. 展开更多
关键词 Direct current gas-insulated switchgear assemblies dc GIS Direct current gas-insulated transmission lines dc GIL Modular design Underground installation Containerized installation Offshore platform installation Transition station
在线阅读 下载PDF
Influences of ±800 kV Yunnan-Guangdong HVDC System on Security and Stability of China Southern Power Grid
8
作者 Baorong Zhou Xiaoming Jin +2 位作者 Chao Hong Pei Zhang Zhigang Wu 《Energy and Power Engineering》 2013年第4期1230-1234,共5页
The interaction mechanism between AC and DC systems in a hybrid AC-DC transmission grid is discussed with PSS/E software. Analysis shows that receiving-end AC faults may cause much more damage on the HVDC system opera... The interaction mechanism between AC and DC systems in a hybrid AC-DC transmission grid is discussed with PSS/E software. Analysis shows that receiving-end AC faults may cause much more damage on the HVDC system operation than the sending-end AC faults in a multi-infeed HVDC system, and the damage severity depends on the power recovering rate of the HVDC systems. For HVDC systems with slow power recovering rate, the receiving-end AC faults may probably be a critical factor to constrain power transfer limits. Larger capacity of HVDC system means not only higher power transfer-limit of the parallel connected AC-DC transmission grid, but also more expensive stabilizing cost. 展开更多
关键词 HVdc SECURITY Stability AC/dc Power system Interaction
暂未订购
Analysis of Commutation Failure in Multi-Infeed HVDC System under Different Load Models
9
作者 Chengjun Xia Zhongchao Yang +1 位作者 Kun Men Yong Zhao 《Journal of Power and Energy Engineering》 2014年第9期154-161,共8页
HVDC technology has been widely used in modern power system. On one hand, HVDC has the advantages of economy, high efficiency and strong controllability. While on the other hand, it makes the dynamic characteristics o... HVDC technology has been widely used in modern power system. On one hand, HVDC has the advantages of economy, high efficiency and strong controllability. While on the other hand, it makes the dynamic characteristics of the power system becoming more and more complex. That puts forward a new challenge to system stability and raises new questions for power system simulation. This paper focuses on the interaction between AC and DC systems, especially the problem of commutation failure caused by AC system fault. Based on the data of China Southern Power Grid, this paper calculates the fault regions that may cause commutation failure and calculates the system critical clearance time under different load models, analyzes the impacts of different load models on commutation failure and the stability of AC/DC hybrid system. 展开更多
关键词 AC/dc Hybrid system COMMUTATION Failure VOLTAGE of CONVERTER BUS Load Model Power system Simulation
在线阅读 下载PDF
A Double-Ended Protection Principle for an LCC-VSC-MTDC System with Strong Anti-Interference Ability
10
作者 ChuanjianWu Dahai Zhang Jinghan He 《Energy Engineering》 EI 2023年第2期299-316,共18页
The DC grid technology of multi-power supply and multi-drop-point power reception is an effective solution for large-scale renewable energy integration into the power grid.Line-commutated converter-Voltage source conv... The DC grid technology of multi-power supply and multi-drop-point power reception is an effective solution for large-scale renewable energy integration into the power grid.Line-commutated converter-Voltage source converter(LCC-VSC)power grids are one of the more important developmental directions of the future power grid that have occured in recent years.But the multi-terminal high voltage direct current system has the problems of inconsistent boundary characteristics,inconsistent control,and fault response characteristics,which puts higher requirements on the protection scheme.Thus,a completely new protection principle is proposed in this paper.Firstly,the fault characteristics of distributed capacitance current are analyzed.The reactive power calculated by the distribution parameters of different frequencies is different.Subsequently,the fault characteristics of DC reactive power are analyzed,and a DC reactive power extraction algorithm is proposed.The polarity of the multi-band DC reactive power is used to construct the protection scheme.Finally,the LCC-VSC power grid model verifies the correctness and superiority of the proposed protection scheme.The proposed scheme uses DC reactive power instead of fault current to solve the long delay problem caused by distributed capacitance.Compared with the prior art,the proposed solution is not affected by distributed capacitance and has a stronger anti-interference ability(600Ω+10 dB+1 ms). 展开更多
关键词 Hybrid dc transmission double-ended protection S transform Hilbert transform
在线阅读 下载PDF
A Single-Ended Protection Principle for LCC-VSC-MTDC System with High Resistance Fault Tolerance
11
作者 Dahai Zhang Chuanjian Wu Jinghan He 《Energy Engineering》 EI 2023年第1期1-21,共21页
Line-commutated converter-voltage source converter(LCC-VSC)power transmission technology does not have the problem of communication failure very usually.It therefore can support the long-distance,long-capacity transmi... Line-commutated converter-voltage source converter(LCC-VSC)power transmission technology does not have the problem of communication failure very usually.It therefore can support the long-distance,long-capacity transmission of electric energy.However,factors such as topology,control strategy,and short-circuit capacities make the traditional protection principles not fully applicable to LCC-VSC hybrid transmission systems.To enhance the reliability of hybrid DC systems,a single-ended principle based on transmission coefficients is proposed and produced.First,the equivalent circuit of the LCC-VSC hybrid DC system is analyzed and the expression of the first traveling wave is deduced accordingly.Then,the concept of multi-frequency transmission coefficients is proposed by analyzing the amplitude-frequency,and the characteristics of each element.Finally,the LCC-VSCDC system model is built to verify the reliability and superiority of the principle itself.Theoretical analysis and experimental verification show that the principle has strong interference resistance. 展开更多
关键词 Hybrid dc transmission single-ended protection principle multi-frequency transmission coefficient
在线阅读 下载PDF
Construction of MMC-CLCC Hybrid DC Transmission System and Its Power Flow Reversal Control Strategy
12
作者 Yechun Xin Xinyuan Zhao +3 位作者 Dong Ding Shuyu Chen Chuanjie Wang Tuo Wang 《Energy Engineering》 2026年第1期460-474,共15页
To enhance power flow regulation in scenarios involving large-scale renewable energy transmission via high-voltage direct current(HVDC)links and multi-infeed DC systems in load-center regions,this paper proposes a hyb... To enhance power flow regulation in scenarios involving large-scale renewable energy transmission via high-voltage direct current(HVDC)links and multi-infeed DC systems in load-center regions,this paper proposes a hybrid modular multilevel converter–capacitor-commutated line-commutated converter(MMC-CLCC)HVDC transmission system and its corresponding control strategy.First,the system topology is constructed,and a submodule configuration method for the MMC—combining full-bridge submodules(FBSMs)and half-bridge submodules(HBSMs)—is proposed to enable direct power flow reversal.Second,a hierarchical control strategy is introduced,includingMMCvoltage control,CLCC current control,and a coordinationmechanism,along with the derivation of the hybrid system’s power flow reversal characteristics.Third,leveraging the CLCC’s fast current regulation and theMMC’s negative voltage control capability,a coordinated power flow reversal control strategy is developed.Finally,an 800 kV MMC-CLCC hybrid HVDC system is modeled in PSCAD/EMTDC to validate the power flow reversal performance under a high proportion of full-bridge submodule configuration.Results demonstrate that the proposed control strategy enables rapid(1-s transition)and smooth switching of bidirectional power flow without modifying the structure of primary equipment:the transient fluctuation ofDC voltage from the rated value(UdcN)to themaximumreverse voltage(-kUdcN)is less than 5%;the DC current strictly follows the preset characteristic curve with a deviation of≤3%;the active power reverses continuously,and the system maintains stable operation throughout the reversal process. 展开更多
关键词 Hybrid HVdc transmission modular multilevel converter(MMC) controllable line commutated converter(CLCC) online power flow reversal full-bridge and half-bridge submodules new energy through dc transmission system
在线阅读 下载PDF
Integrated Multiport Flexible Voltage Clamp Circuit Breaker with DC Chopper Applied to MMC-HVDC System
13
作者 Guoqing Li Yuheng Song +3 位作者 Jing Bian Yanxu Wang Kefei Yan Menghan Li 《CSEE Journal of Power and Energy Systems》 2026年第1期352-365,共14页
Given the wide application of DC grids,the protection equipment of power grids must be improved during the fault period.This study proposes an integrated multiport flexible voltage clamp circuit breaker with a DC chop... Given the wide application of DC grids,the protection equipment of power grids must be improved during the fault period.This study proposes an integrated multiport flexible voltage clamp circuit breaker with a DC chopper acting on the receiving end converter to solve the DC short circuit fault and surplus power because of AC low-voltage fault;it has a modular design.As a DC circuit breaker,the device utilizes the voltage-clamping principle and thyristor semi-control to remove faults.As the fault current increases,the branch circuit outputs different voltage levels by selecting different gears,thereby controlling the voltage-clamping effect.This device can distinguish between different fault types to prevent secondary shocks in the system.As a DC chopper,the voltage at both ends of the energy dissipation resistor is varied by switching submodules,consuming surplus power to complete AC low-voltage faults and minimizing the impact of low-voltage faults on the system’s transmission capacity.Finally,the effectiveness and applicability of the equipment are verified using wind turbines connected to a flexible DC transmission three-terminal power grid model in PSCAD/EMTDC,and two fault simulation types are analyzed.A comparison of the electrical quantities(fault current,system voltage and branch voltage)of the proposed circuit breaker with other similar equipment shows that due to the efficiency of the proposed equipment,the peak fault current is reduced by at least 35.8%.The required voltage stress of key power electronic equipment is reduced by at least 71.5%.Therefore,the equipment ensures that the per-unit voltage of the DC system does not exceed 1.05 during AC fault crossing. 展开更多
关键词 dc Chopper flexibility voltage clamp multiport dc circuit breaker reclosing scheme thyristor
原文传递
Unified Iterative Algorithm for Power Flow of AC/DC System with Multi-type DC Links
14
作者 Zhiqiang Song Yaohui Huang +3 位作者 Jianzhong Xu Chengyong Zhao Xiufang Jia Huashi Zhao 《CSEE Journal of Power and Energy Systems》 2025年第5期2293-2302,共10页
As an emerging trend in power grid development,the AC/DC hybrid power grid presents the characteristics of multi-type DC links and large-scale AC/DC interconnection.However,existing research on AC/DC power flow calcul... As an emerging trend in power grid development,the AC/DC hybrid power grid presents the characteristics of multi-type DC links and large-scale AC/DC interconnection.However,existing research on AC/DC power flow calculation is mainly based on single-object models,ignoring the complex interactions and interdependencies between the AC system and various types of DC links in the hybrid power grid,such as LCCHVDC,MMC-HVDC,and LCC-MMC hybrid HVDC.Therefore,this paper proposes a power flow calculation algorithm for large-scale AC/DC systems with multi-type DC links.Firstly,a CIM/XML document conversion strategy applicable to the AC/DC system is proposed.Then,a unified modeling method is used to derive the power flow model of the AC/DC system,and a unified iterative algorithm for the large-scale AC/DC system with multi-type DC links is proposed.Finally,the algorithm’s correctness and effectiveness are verified by comparing it with actual measurements from the Southern Power Grid of China,with a voltage deviation of less than 1%.The research shows that the proposed algorithm has good convergence and high computational efficiency,which is applicable to power flow calculations in large-scale DC-embedded hybrid AC/DC grids in the future. 展开更多
关键词 AC/dc system CIM/XML documents multi type dc links power flow calculation unified iterative algorithm
原文传递
Remote Coordination Adjustment of Power Electronic Devices in AC/DC Systems by Power Flow Calculation with Linearization and Sensitivity
15
作者 Junzhou Wang Xingyu Lin +3 位作者 Junjie Tang Yuzhi Wang Guodong Huang Dan Xu 《Journal of Modern Power Systems and Clean Energy》 2025年第6期2168-2179,共12页
High proportion of renewable energies and the installation of power electronic devices(PEDs)pose tough challenges to the operation of power systems.In this paper,the remote coordination adjustment(RCA)of PEDs in stoch... High proportion of renewable energies and the installation of power electronic devices(PEDs)pose tough challenges to the operation of power systems.In this paper,the remote coordination adjustment(RCA)of PEDs in stochastic scenarios is studied.The steady-state model for the AC/DC system with PEDs is first established,and the alternate iteration method based on linearization(AIML)is adopted,especially for efficient deterministic power flow calculation.Then,the RCA is proposed using a modular local sensitivity method combined with AIML,which can adjust the electrical variables by diverse PEDs with high efficiency.Additionally,the probabilistic power flow calculation using the quasi-Monte Carlo method with the adaptive sampling number(ASN-QMC)is introduced to keep the balance between the computational efficiency and accuracy,as well as demonstrating the positive impact of RCA by the PEDs in stochastic scenarios.The effectiveness of the proposed RCA is validated by a series of modified IEEE test systems. 展开更多
关键词 Power electronic device remote coordination adjustment(RCA) AC/dc system LINEARIZATION sensitivity UNCERTAINTY power flow quasi-Monte Carlo
原文传递
DC Fault Current Calculation Method and Transient Characteristics of True Bipolar MMC-HVDC Systems
16
作者 Botong Li Yichao Liu +3 位作者 Bin Li Wenxin Wang Weijie Wen Xiaolong Chen 《CSEE Journal of Power and Energy Systems》 2025年第4期1704-1716,共13页
In this paper,the calculation method and transient characteristics of asymmetric faults in the DC side of a true bipolar system are studied.First,two typical MMC fault equivalent methods are analyzed,and comparison sh... In this paper,the calculation method and transient characteristics of asymmetric faults in the DC side of a true bipolar system are studied.First,two typical MMC fault equivalent methods are analyzed,and comparison shows that active RLC equivalent branches are more suitable for fault analyses of a true bipolar system.Second,considering the influence of mutual impedance between the poles in DC side,a DC fault current calculation method for a true bipolar systems is proposed.Finally,the characteristics of transient electrical quantities including fault current and DC voltage in the process of DC faults in true bipolar systems are analyzed and summarized to provide references for the design of DC line insulation and relay protection schemes. 展开更多
关键词 dc faults fault current calculation method transient characteristics true bipolar MMC-HVdc systems
原文传递
核安全级DCS系统SVDU设计检查方法研究
17
作者 王飞 李强 +4 位作者 何伟 王顺冰 姚映帆 金雪莲 邓小军 《工业控制计算机》 2026年第2期44-45,47,共3页
SVDU作为核安全级DCS系统的关键部件,其设计质量直接影响着系统的可靠性和安全性,进而影响到核电厂的安全稳定运行。采用了排列图法从以往项目中寻找出了影响SVDU设计质量的关键因素,结合平台特性设计了一套完善的检查方法,特别是对于... SVDU作为核安全级DCS系统的关键部件,其设计质量直接影响着系统的可靠性和安全性,进而影响到核电厂的安全稳定运行。采用了排列图法从以往项目中寻找出了影响SVDU设计质量的关键因素,结合平台特性设计了一套完善的检查方法,特别是对于影响质量的A、B、C类因素进行专项检查,确保影响设计质量的主要因素被有效降低。采用自主研发的软件工具,将数据导出和实现自动检查,极大地提高检查效率和质量。经过工程实践的应用,进一步证实了检查方法的可行性和准确性,为核安全级DCS系统SVDU设计质量提供了有效的支撑和保障。 展开更多
关键词 核安全级dcS 排列图法 设计质量
在线阅读 下载PDF
双有源桥隔离式双向AC/DC变换器及控制方法
18
作者 葛峻辰 刘毅力 郭驰岳 《传感器与微系统》 北大核心 2026年第3期158-164,共7页
采用隔离式双向AC/DC变换器实现了电池与单相电网的连接。所分析的结构是可控制由可再生能源、电池组和单相电网组成的微电网潮流的双有源桥式单相AC/DC变换器。对变换器的分析主要集中在连接结构与控制方法,抑制了母线电压的波动。采... 采用隔离式双向AC/DC变换器实现了电池与单相电网的连接。所分析的结构是可控制由可再生能源、电池组和单相电网组成的微电网潮流的双有源桥式单相AC/DC变换器。对变换器的分析主要集中在连接结构与控制方法,抑制了母线电压的波动。采用了改进二阶广义积分器(SOGI)的单相锁相环(PLL),为了克服传统PLL的环路滤波器难以完全滤除输入信号的谐波并在PLL输出信号中产生相位偏移这一问题,提出了一种并网电压源变换器电流调节的矢量控制策略。最后,通过PLECS软件对电压、电流信号进行仿真。仿真结果表明:基于二阶带通滤波器的PLL能够很好抑制直流分量和高频分量,有效消除因参数设置不合理产生的相位偏移,并且验证了双向AC/DC变换器控制策略的可行性。 展开更多
关键词 双向AC/dc变换器 储能 锁相环 程序设计
在线阅读 下载PDF
含储能的混合式配电变压器中双向DC-DC变换器设计
19
作者 栗世超 梁得亮 +1 位作者 柳轶彬 孔子涵 《变压器》 2026年第2期1-6,共6页
本文作者提出了一种含储能的混合式配电变压器(Hybrid Distribution Transformer,HDT)电路拓扑,并重点研究了双向DC/DC变换器的设计。该拓扑结合储能电池和超级电容,通过双向DC/DC变换器实现HDT与储能装置之间的双向电能流动。本文推导... 本文作者提出了一种含储能的混合式配电变压器(Hybrid Distribution Transformer,HDT)电路拓扑,并重点研究了双向DC/DC变换器的设计。该拓扑结合储能电池和超级电容,通过双向DC/DC变换器实现HDT与储能装置之间的双向电能流动。本文推导了双向DC/DC变换器的小信号模型,详细阐述了电路参数选取方法,并设计了相应的控制器。在Matlab/Simulink中实现了仿真验证,结果表明所设计的系统能够实现功率的双向传递,验证了所提出拓扑和控制策略的有效性和可行性。 展开更多
关键词 混合式配电变压器 双向dc/dc电路 小信号模型 超级电容 储能电池
原文传递
一种隔离式DC/DC变换器输出电压动态调整方案
20
作者 董礼 黄国良 +1 位作者 彭昊 陈长兴 《电子技术应用》 2026年第2期95-99,共5页
针对目前供电系统无法在线动态调节电压的不足,提出了一种实现开关电源输出电压动态调整方案。该方案适配多种有线通信协议,受系统控制,在工作过程中动态调整开关电源输出电压以适配负载供电要求;同时实现对输出电压的同步监测,并回传... 针对目前供电系统无法在线动态调节电压的不足,提出了一种实现开关电源输出电压动态调整方案。该方案适配多种有线通信协议,受系统控制,在工作过程中动态调整开关电源输出电压以适配负载供电要求;同时实现对输出电压的同步监测,并回传至系统上位机,从而实现对输出电压的在线调整和监控功能。 展开更多
关键词 dc/dc变换器 输出电压动态调整 数字通信
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部