期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Calculations of Chemical Reaction Dynamics for D+ H_2(j_i,ν_i=0)→DH(j_f, ν_f=0) + H
1
作者 Li Qin SI(Editorial Office of Natural Science, Yantai Normal University, Yantai, 264025) 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第2期153-156,共4页
The constant Centrifugal potential approximation is Corrected so as to apply to the reactions of rotational excited reactants for D + H2 (j,, νi = 0 ) -DH(jf, νf = 0) + H. Our results show that the contributions fro... The constant Centrifugal potential approximation is Corrected so as to apply to the reactions of rotational excited reactants for D + H2 (j,, νi = 0 ) -DH(jf, νf = 0) + H. Our results show that the contributions from ji≠0 and Ωi terms are not negligible. 展开更多
关键词 dH j_f H2 j_i i=0 calculations of Chemical Reaction dynamics for d
在线阅读 下载PDF
Acuros-Based Planning with Density Override for Lung SBRT by a Dynamic Conformal Arc Technique: Comparative Evaluation with AAA-Based Planning in Four-Dimensional Dose
2
作者 Inhwan Yeo Neil Joyce +5 位作者 Deepinder P. Singh Michael T. Milano Yuhchyau Chen Sanjukta Bandyopadhyay Hongmei Yang Douglas Rosenzweig 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2021年第2期94-110,共17页
<div style="text-align:justify;"> <span style="font-family:Verdana;">The purpose of this study was to evaluate a planning strategy based on Acuros with density override in comparison wi... <div style="text-align:justify;"> <span style="font-family:Verdana;">The purpose of this study was to evaluate a planning strategy based on Acuros with density override in comparison with AAA without and with the override. Ten lung-tumor patients were selected with each PTV size around 2 - 4 cm and were imaged using slow scan, followed by four-dimensional (4D) imag</span><span style="font-family:Verdana;">ing limited to the target. On each phase-specific image, gross tumor </span><span style="font-family:Verdana;">volume (GTV) was contoured. Summed over all phases, an integrated GTV (iGTV) was generated and copied to the slow scan. A treatment plan was created using a dynamic-conformal-arc technique with AAA to prescribe 60 Gy to 95% of PTV (iGTV + 0.5 cm). Each AAA-based plan was regenerated by overriding the density of the setup margin of PTV by GTV density (modeling tumor-position uncertainty). It was also regenerated with Acuros and the override. The three plans were validated in 4D dose to PTV, after similarly overriding PTV density (phase-specific), accurately calculating with Acuros, and summing the phase-specific plans through organ/dose registration. The Acuros-based plan with the override, the AAA-based plan, and the AAA-based plan with the override provided 4D PTV doses of 63.9, 67.9, and 62 Gy at D95%, respectively, averaged over all patients. The override with Acuros and AAA produced lesser 4D doses, closer to the associated 3D doses, respectively, than that without the override, with better conformity and inhomogeneity. With the override in common, Acuros provided a greater dose to PTV than that by AAA. The Acuros with the override, which was more accurate than the AAA without the override, is clinically recommended.</span> </div> 展开更多
关键词 Lung SBRT Acuros density Override AAA 4d dose calculation
暂未订购
Rotating instability in the vaneless diffuser of a radial flow pump 被引量:2
3
作者 A.Dazin O.Coutier-Delgosha +3 位作者 P.Dupont S.Coudert G.Caignaert G.Bois 《Journal of Thermal Science》 SCIE EI CAS CSCD 2008年第4期368-374,共7页
The paper refers to the behavior of a vaneless diffuser of a radial flow pump in partial flow operating conditions. Some experimental data have been obtained using 2D/2C PIV and unsteady pressure measurements within t... The paper refers to the behavior of a vaneless diffuser of a radial flow pump in partial flow operating conditions. Some experimental data have been obtained using 2D/2C PIV and unsteady pressure measurements within the diffuser, in various operating conditions. The experimental results at the lower flow rate are compared with two-dimensional numerical calculations. 展开更多
关键词 Vaneless diffuser Radial flow pump INSTABILITY Particle Image Velocimetry Pressure measurements 2d calculations.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部