期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
1
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault Grounding protection Zero-sequence current ratio coefficient
在线阅读 下载PDF
WAVE CURRENT FORCE COEFFICIENTS ON INCLINED CYLINDER AND A NEW ESTIMATION METHOD 被引量:2
2
作者 Teng Bin and Li Yucheng Research Assistant, Dalian University of Technology, Dalian Professor, Dalian University of Technology, Dalian 《China Ocean Engineering》 SCIE EI 1990年第3期283-296,共14页
Based on the review of present force coefficients estimation methods, a new method in the frequency domain, revised cross-spectrum estimation method, is presented in this paper. Some experiments on the wave-current fo... Based on the review of present force coefficients estimation methods, a new method in the frequency domain, revised cross-spectrum estimation method, is presented in this paper. Some experiments on the wave-current force on inclined cylinders are also described and the wave current force coefficients are estimated by the revised cross-spectrum estimation method. From the results, it is found that the wave and current directions have some regular effect on the coefficients. According to the results, some empirical formulas are obtained for converting the wave-current force coefficients on inclined cylinders into a unified coefficient. Comparisons show that the unified coefficients are in good agreement with other results. 展开更多
关键词 WAVE current FORCE coefficientS ON INCLINED CYLINDER AND A NEW ESTIMATION METHOD Mean
在线阅读 下载PDF
Current dependence coefficient determination for different DC standard resistors measurements based on Ⅴ-Ⅰ method 被引量:1
3
作者 Rasha S M Ali M Helmy A Raouf 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第4期332-335,共4页
Current dependence and stability of the measured resistance value are very important for the accurate measurement of DC standard resistor. In this paper, the volt-ampere (V-I) measurement method has been applied ... Current dependence and stability of the measured resistance value are very important for the accurate measurement of DC standard resistor. In this paper, the volt-ampere (V-I) measurement method has been applied to study the current depend-ence of four different types of standard resistors. Diverse values are obtained through the investigation of their stability at dif-ferent currents. Therefore, the current dependence coefficient (CDC) can be determined for each one of the studied resistors. Research shows CDC depends on the applied current value, the measurement time and the resistor type, as clearly demonstra-ted in this research. 展开更多
关键词 current dependence coefficient standard resistors volt-ampere method resistor stability
在线阅读 下载PDF
An Improvement on Current Sharing Characteristics of Poloidal Field (PF) AC-DC Converters 被引量:1
4
作者 陈鹏 傅鹏 宋执权 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第4期497-501,共5页
In response to the current imbalance phenomenon and its harmfulness, a current sharing circuit model is built up, which reveals the underlying causes for the current imbalance through a quantitative analysis. Then, a ... In response to the current imbalance phenomenon and its harmfulness, a current sharing circuit model is built up, which reveals the underlying causes for the current imbalance through a quantitative analysis. Then, a feasible approach of improvement, namely enlargement of the length of connection busbars, is proposed. After the amendment, it can be seen that the current sharing coefficient is ahnost unity under rated or fault current conditions. 展开更多
关键词 current sharing circuit model the length of connection busbars current imbalanced coefficient
在线阅读 下载PDF
Design of Double-Loop Current Transformer Based on Magnetic Field Incomplete Cancellation
5
作者 Wenbo Li Xiaojun Tang +3 位作者 Youshui Lu Ling Yan Yi Wu Mingzhe Rong 《CSEE Journal of Power and Energy Systems》 2025年第2期772-782,共11页
Electromagnetic current transformer is one of the important pieces of equipment used in AC power system measurement. Due to continuous improvement of current level to be measured in the power system, ordinary single-l... Electromagnetic current transformer is one of the important pieces of equipment used in AC power system measurement. Due to continuous improvement of current level to be measured in the power system, ordinary single-loop magnetic core structure cannot meet industrial needs of wide measuring range with high accuracy, while it even has a magnetic saturation problem when measured current is reaching the limit. Most existing methods expand measuring range and increase antisaturation ability of the magnetic core by either opening an air gap in the magnetic core or increasing number of turns of primary and secondary windings, but it will bring additional problems such as volume and heat dissipation of the transformer. To solve such issues, in this paper, we proposed a magnetic core structure of double-loop current transformer based on incomplete magnetic field cancellation principle. Calculation formula of air gap size and theoretical error are analyzed. We provide a theo-retical analysis of working characteristics, amplitude error and phase error throughout a three-dimensional simulation model of transformer. In addition, we evaluate performance through a series of comparison experiments. Results demonstrate our double-loop current transformer can maintain good linear relationship between primary and secondary current while ensuring measurement accuracy at 0.2 level. With the same volume, it has a wider range of rated current measurements and a certain anti-saturation ability. 展开更多
关键词 current difference coefficient double-loop core incomplete magneticfield cancellation
原文传递
PMU based adaptive zone settings of distance relays for protection of multi-terminal transmission lines 被引量:3
6
作者 Balimidi Mallikarjuna Pudi Shanmukesh +2 位作者 Dwivedi Anmol Maddikara Jaya Bharata Reddy Dusmanta Kumar Mohanta 《Protection and Control of Modern Power Systems》 2018年第1期136-150,共15页
This paper proposes Phasor Measurement Unit(PMU)based adaptive zone settings of distance relays(PAZSD)methodology for protection of multi-terminal transmission lines(MTL).The PAZSD methodology employs current coeffici... This paper proposes Phasor Measurement Unit(PMU)based adaptive zone settings of distance relays(PAZSD)methodology for protection of multi-terminal transmission lines(MTL).The PAZSD methodology employs current coefficients to adjust the zone settings of the relays during infeed situation.These coefficients are calculated in phasor data concentrator(PDC)at system protection center(SPC)using the current phasors obtained from PMUs.The functioning of the distance relays during infeed condition with and without the proposed methodology has been illustrated through a four-bus model implemented in PSCAD/EMTDC environment.Further,the performance of the proposed methodology has been validated in real-time,on a laboratory prototype of Extra High Voltage multi-terminal transmission lines(EHV MTL).The phasors are estimated in PMUs using NI cRIO-9063 chassis embedded with data acquisition sensors in conjunction with LabVIEW software.The simulation and hardware results prove the efficacy of the proposed methodology in enhancing the performance and reliability of conventional distance protection system in real-time EHV MTLs. 展开更多
关键词 Extra high voltage(EHV) Multiterminal transmission line(MTL) Phasor measurement unit(PMU) Phasor data concentrator(PDC) current coefficients
在线阅读 下载PDF
上一页 1 下一页 到第