EMC anechoic chamber is used for radiation emission and radiation immunity test,and the wireless performance of products needs to be tested in OTA anechoic chamber.With more and more electronic and electrical equipmen...EMC anechoic chamber is used for radiation emission and radiation immunity test,and the wireless performance of products needs to be tested in OTA anechoic chamber.With more and more electronic and electrical equipment with wireless communication function,the rapid construction of a compatible OTA test system in the existing EMC anechoic chamber can save the cost and space of enterprises and third-party laboratories that already have EMC anechoic chamber.In this paper,the OTA test system is built in the existing EMC anechoic room,the ripple calibration test is carried out according to the OTA standard,the TRP and TIS tests are carried out on two test samples with different wireless communication standards,and the test samples are taken to the OTA anechoic room for a comparison test.The comparison between the ripple calibration data and the OTA test data showed that the EMC anechoic chamber could perform OTA test without affecting the original test ability.The data results provide a basis for the implementation of EMC anechoic chamber compatibility upgrade OTA test,and provide reference for further optimization of the compatible test system,reduction of test differences,and the design of anechoic chamber integrating two test functions.展开更多
Because of their good mechanical properties under irradiation up to 500 ?C, ferritic/martensitic steels are consideredto be the promising structural materials for advanced nuclear reactors. However, severe corrosion o...Because of their good mechanical properties under irradiation up to 500 ?C, ferritic/martensitic steels are consideredto be the promising structural materials for advanced nuclear reactors. However, severe corrosion of structuralmaterials occurs in the presence of LBE in advanced nuclear reactors, especially at high temperature[1]. Therefore,the selection of the structural material exposed to LBE is an extremely complex problem and compatibility testsare required.展开更多
The longitudinal dispersion of the projectile in shooting tests of two-dimensional trajectory corrections fused with fixed canards is extremely large that it sometimes exceeds the correction ability of the correction ...The longitudinal dispersion of the projectile in shooting tests of two-dimensional trajectory corrections fused with fixed canards is extremely large that it sometimes exceeds the correction ability of the correction fuse actuator.The impact point easily deviates from the target,and thus the correction result cannot be readily evaluated.However,the cost of shooting tests is considerably high to conduct many tests for data collection.To address this issue,this study proposes an aiming method for shooting tests based on small sample size.The proposed method uses the Bootstrap method to expand the test data;repeatedly iterates and corrects the position of the simulated theoretical impact points through an improved compatibility test method;and dynamically adjusts the weight of the prior distribution of simulation results based on Kullback-Leibler divergence,which to some extent avoids the real data being"submerged"by the simulation data and achieves the fusion Bayesian estimation of the dispersion center.The experimental results show that when the simulation accuracy is sufficiently high,the proposed method yields a smaller mean-square deviation in estimating the dispersion center and higher shooting accuracy than those of the three comparison methods,which is more conducive to reflecting the effect of the control algorithm and facilitating test personnel to iterate their proposed structures and algorithms.;in addition,this study provides a knowledge base for further comprehensive studies in the future.展开更多
基金Yancheng Science and Technology Bureau(YCBK2023027)。
文摘EMC anechoic chamber is used for radiation emission and radiation immunity test,and the wireless performance of products needs to be tested in OTA anechoic chamber.With more and more electronic and electrical equipment with wireless communication function,the rapid construction of a compatible OTA test system in the existing EMC anechoic chamber can save the cost and space of enterprises and third-party laboratories that already have EMC anechoic chamber.In this paper,the OTA test system is built in the existing EMC anechoic room,the ripple calibration test is carried out according to the OTA standard,the TRP and TIS tests are carried out on two test samples with different wireless communication standards,and the test samples are taken to the OTA anechoic room for a comparison test.The comparison between the ripple calibration data and the OTA test data showed that the EMC anechoic chamber could perform OTA test without affecting the original test ability.The data results provide a basis for the implementation of EMC anechoic chamber compatibility upgrade OTA test,and provide reference for further optimization of the compatible test system,reduction of test differences,and the design of anechoic chamber integrating two test functions.
文摘Because of their good mechanical properties under irradiation up to 500 ?C, ferritic/martensitic steels are consideredto be the promising structural materials for advanced nuclear reactors. However, severe corrosion of structuralmaterials occurs in the presence of LBE in advanced nuclear reactors, especially at high temperature[1]. Therefore,the selection of the structural material exposed to LBE is an extremely complex problem and compatibility testsare required.
基金the National Natural Science Foundation of China(Grant No.61973033)Preliminary Research of Equipment(Grant No.9090102010305)for funding the experiments。
文摘The longitudinal dispersion of the projectile in shooting tests of two-dimensional trajectory corrections fused with fixed canards is extremely large that it sometimes exceeds the correction ability of the correction fuse actuator.The impact point easily deviates from the target,and thus the correction result cannot be readily evaluated.However,the cost of shooting tests is considerably high to conduct many tests for data collection.To address this issue,this study proposes an aiming method for shooting tests based on small sample size.The proposed method uses the Bootstrap method to expand the test data;repeatedly iterates and corrects the position of the simulated theoretical impact points through an improved compatibility test method;and dynamically adjusts the weight of the prior distribution of simulation results based on Kullback-Leibler divergence,which to some extent avoids the real data being"submerged"by the simulation data and achieves the fusion Bayesian estimation of the dispersion center.The experimental results show that when the simulation accuracy is sufficiently high,the proposed method yields a smaller mean-square deviation in estimating the dispersion center and higher shooting accuracy than those of the three comparison methods,which is more conducive to reflecting the effect of the control algorithm and facilitating test personnel to iterate their proposed structures and algorithms.;in addition,this study provides a knowledge base for further comprehensive studies in the future.