To investigate the influences of co-flowand counter-flowmodes of reactant flowarrangement on a proton exchange membrane fuel cell(PEMFC)during start-up,unsteady physical and mathematical models fully coupling the flow...To investigate the influences of co-flowand counter-flowmodes of reactant flowarrangement on a proton exchange membrane fuel cell(PEMFC)during start-up,unsteady physical and mathematical models fully coupling the flow,heat,and electrochemical reactions in a PEMFC are established.The continuity equation and momentum equation are solved by handling pressure-velocity coupling using the SIMPLE algorithm.The electrochemical reaction rates in the catalyst layers(CLs)of the cathode and anode are calculated using the Butler-Volmer equation.The multiphase mixture model describes the multiphase transport process of gas mixtures and liquid water in the fuel cell.After validation,the influences of co-flow and counter-flow modes on the PEMFC performance are investigated,including the evolution of the current density,flow field,temperature field,and reactant concentration field during start-up,as well as the steady distribution of the current density,reactant concentration,andmembrane water content when the start-up stabilizes.Co-flow and counter-flow modes influence the current density distribution and temperature distribution.On the one hand,the co-flow mode accelerates the start-up process of the PEMFC and leads to a more evenly distributed current density than the counter-flow mode.On the other hand,the temperature difference between the inlet and outlet sections of the cell is up to 10.1℃ under the co-flow mode,much larger than the 5.0℃ observed in the counter-flow mode.Accordingly,the counter-flowmode results in a more evenly distributed temperature and a lower maximum temperature than the co-flow case.Therefore,in the flow field design of a PEMFC,the reactant flow arrangements can be considered to weigh between better heat management and higher current density distribution of the cell.展开更多
Reaction zone characteristics were studied using hydroxy radical planar laser-induced fluorescence (OH-PLIF) technique for a counter-flow preheated (CH4+N2)/(Air+N2) diluted diffusion flames. The effects of pr...Reaction zone characteristics were studied using hydroxy radical planar laser-induced fluorescence (OH-PLIF) technique for a counter-flow preheated (CH4+N2)/(Air+N2) diluted diffusion flames. The effects of preheat temperature and dilute ratio on the reaction zone characteristics were investigated by demonstrating the OH intensity distribution and reaction zone thickness from OH-PLIF images. Under the experimental conditions of constant cold flow velocity, the results show that the OH intensity and reaction zone thickness decrease with the increase of dilute ratio at constant preheat temperature and increase with preheat temperature at fixed dilute ratio. The OH maximum intensity shifts towards the "lean" side of counter flow at constant preheat temperature, and it shifts towards the fuel side with the increase of dilute ratio of fuel stream and towards the oxidizer side with the increase of dilute ratio of oxidizer stream respectively. The feasibility of OH as a reaction zone marker in this diluted combustion is verified further. The variation of diffusion and chemical reaction rate of reactants due to preheat and dilution contributes to the reaction zone characteristics simultaneously. The effect of strain on the flame reaction zone should be included in the future work.展开更多
The flow of an active thermal protection system exploiting subsonic counter-flow jets for wing leading edges of hypersonic vehicles is numerically studied on the basis of the three dimensional Navier-Stokes equations....The flow of an active thermal protection system exploiting subsonic counter-flow jets for wing leading edges of hypersonic vehicles is numerically studied on the basis of the three dimensional Navier-Stokes equations.The coolant air issuing from around the stagnation point as an array of three jets spreads over both the upper and the lower sides of the cylinder surface and about 40~60%cooling effectiveness is achieved in the range up to 5 degrees angle of attack despite the occurrence of various three-dimensional fluid-dynamic instabilities.The numerical scheme is second order accurate but simple inclusion of high order polynomial approximation in the reconstruction enables the capturing of finer structure of the flow field.展开更多
基金supported by the Projects of Talents Recruitment of Guangdong University of Petrochemical Technology(No.2018rc14)Maoming City Science and Technology Plan Project(Nos.210427094551264 and 220415004552411).
文摘To investigate the influences of co-flowand counter-flowmodes of reactant flowarrangement on a proton exchange membrane fuel cell(PEMFC)during start-up,unsteady physical and mathematical models fully coupling the flow,heat,and electrochemical reactions in a PEMFC are established.The continuity equation and momentum equation are solved by handling pressure-velocity coupling using the SIMPLE algorithm.The electrochemical reaction rates in the catalyst layers(CLs)of the cathode and anode are calculated using the Butler-Volmer equation.The multiphase mixture model describes the multiphase transport process of gas mixtures and liquid water in the fuel cell.After validation,the influences of co-flow and counter-flow modes on the PEMFC performance are investigated,including the evolution of the current density,flow field,temperature field,and reactant concentration field during start-up,as well as the steady distribution of the current density,reactant concentration,andmembrane water content when the start-up stabilizes.Co-flow and counter-flow modes influence the current density distribution and temperature distribution.On the one hand,the co-flow mode accelerates the start-up process of the PEMFC and leads to a more evenly distributed current density than the counter-flow mode.On the other hand,the temperature difference between the inlet and outlet sections of the cell is up to 10.1℃ under the co-flow mode,much larger than the 5.0℃ observed in the counter-flow mode.Accordingly,the counter-flowmode results in a more evenly distributed temperature and a lower maximum temperature than the co-flow case.Therefore,in the flow field design of a PEMFC,the reactant flow arrangements can be considered to weigh between better heat management and higher current density distribution of the cell.
基金supported by the CNRS "ACI-Energie" Program of France and the National Nature Science Foundation of China (No.50606004)
文摘Reaction zone characteristics were studied using hydroxy radical planar laser-induced fluorescence (OH-PLIF) technique for a counter-flow preheated (CH4+N2)/(Air+N2) diluted diffusion flames. The effects of preheat temperature and dilute ratio on the reaction zone characteristics were investigated by demonstrating the OH intensity distribution and reaction zone thickness from OH-PLIF images. Under the experimental conditions of constant cold flow velocity, the results show that the OH intensity and reaction zone thickness decrease with the increase of dilute ratio at constant preheat temperature and increase with preheat temperature at fixed dilute ratio. The OH maximum intensity shifts towards the "lean" side of counter flow at constant preheat temperature, and it shifts towards the fuel side with the increase of dilute ratio of fuel stream and towards the oxidizer side with the increase of dilute ratio of oxidizer stream respectively. The feasibility of OH as a reaction zone marker in this diluted combustion is verified further. The variation of diffusion and chemical reaction rate of reactants due to preheat and dilution contributes to the reaction zone characteristics simultaneously. The effect of strain on the flame reaction zone should be included in the future work.
文摘The flow of an active thermal protection system exploiting subsonic counter-flow jets for wing leading edges of hypersonic vehicles is numerically studied on the basis of the three dimensional Navier-Stokes equations.The coolant air issuing from around the stagnation point as an array of three jets spreads over both the upper and the lower sides of the cylinder surface and about 40~60%cooling effectiveness is achieved in the range up to 5 degrees angle of attack despite the occurrence of various three-dimensional fluid-dynamic instabilities.The numerical scheme is second order accurate but simple inclusion of high order polynomial approximation in the reconstruction enables the capturing of finer structure of the flow field.