使用托吡卡胺进行散瞳前后的瞳孔变化对Corvis ST测量指标的影响因素分析
1
作者 曹红宁 覃光海 孙丹 《世界复合医学(中英文)》 2025年第3期1-4,9,共5页
目的 探究使用托吡卡胺进行散瞳前后的瞳孔变化(自然瞳孔、瞳孔散大8 mm)对可视化角膜生物力学分析仪(Corvis ST)测量指标结果的影响因素。方法 选取2024年3—10月于宜昌爱尔眼科医院屈光手术专科就诊的患者32例(64眼)为研究对象,对同... 目的 探究使用托吡卡胺进行散瞳前后的瞳孔变化(自然瞳孔、瞳孔散大8 mm)对可视化角膜生物力学分析仪(Corvis ST)测量指标结果的影响因素。方法 选取2024年3—10月于宜昌爱尔眼科医院屈光手术专科就诊的患者32例(64眼)为研究对象,对同一患者(2只眼)进行2次同一检查操作,第一次为自然瞳孔,第二次为用托吡卡胺进行散瞳后(瞳孔散大8 mm)。比较两次患者的角膜生物力学检查结果,对其影响因素进行分析,包括角膜地形图生物力学指数(tomographic biomechanical index,TBI)、Corvis生物力学指数(Corvis biomechanical index,CBI)、角膜地形图的Belin/Ambrosio综合偏差值(Belin/Ambrosio deviation display-deviation,BAD-D)、硬度参数(stiffness parameter applanation1,SPA1)、综合半径(integratedradius,IR)、最薄点厚度/厚度变化率(ambrósiorelationalthickness,ARTh)、最大形变幅度(deformation amplitude,DA)、眼压(intraocular pressure,IOP)。结果 自然瞳孔下、瞳孔散大8 mm的TBI、CBI、BAD-D、SPA1、IR、ARTh、DA、IOP比较,差异均无统计学意义(P均>0.05)。用托吡卡胺进行散瞳前后的不同瞳孔情况不是TBI(OR=0.814,P=0.870)、CBI(OR=0.294,P=0.328)、BAD-D(OR=1.078,P=0.899)、SPA1(OR=0.980,P=0.224)、IR(OR=0.747,P=0.446)、ARTh(OR=0.999,P=0.770)、DA(OR=2.250,P=0.422)、IOP(OR=1.193,P=0.081)指标的影响因素。结论 患者用托吡卡胺进行散瞳前的自然瞳孔、进行散瞳后(瞳孔散大8 mm)的角膜生物力学检查结果相似。 展开更多
关键词 散瞳 corvis ST 角膜生物力学 托吡卡胺 影响因素
暂未订购
Corvis ST在白内障超乳术后角膜生物力学改变研究中的应用
2
作者 赵美 白淑红 +1 位作者 白岩昆 詹冬梅 《宁夏医学杂志》 2025年第4期366-368,共3页
白内障是好发于中老年人群的眼科常见致盲性眼病[1],白内障超声乳化手术是迄今为止临床上最主要的治疗白内障的方式。更佳的视觉效果、更小的术源性散光及更小的并发症发生率是该手术的关键[2]。近年来有研究表明,角膜生物力学特性与白... 白内障是好发于中老年人群的眼科常见致盲性眼病[1],白内障超声乳化手术是迄今为止临床上最主要的治疗白内障的方式。更佳的视觉效果、更小的术源性散光及更小的并发症发生率是该手术的关键[2]。近年来有研究表明,角膜生物力学特性与白内障超声乳化手术的安全和预后密切相关。 展开更多
关键词 角膜生物力学 白内障超声乳化术 corvis ST
暂未订购
Comparative analysis of intraocular pressure measurements: a study using noncontact tonometer, goldmann applanation tonometer, and Corvis ST in healthy individuals and glaucoma patients
3
作者 Shaolin Du Yulei Chen +3 位作者 Lingyu Ye Chusheng Cai Xifeng Lin Xiulan Zhang 《Eye Science》 2025年第3期238-247,共10页
Objective:Accurate intraocular pressure(IOP)measurement is a cornerstone of glaucoma diagnosis and management.While Goldmann applanation tonometry(GAT)remains the accepted gold standard,technological advancements have... Objective:Accurate intraocular pressure(IOP)measurement is a cornerstone of glaucoma diagnosis and management.While Goldmann applanation tonometry(GAT)remains the accepted gold standard,technological advancements have introduced alternative methods such as noncontact tonometry(NCT)and the dynamic Scheimpflug-based Corvis ST(CST).This study aims to conduct a rigorous comparative analysis of IOP measurements obtained by NCT,GAT,and CST across a wide spectrum of intraocular pressures.The primary objectives were to evaluate the performance of these devices in both healthy and glaucomatous eyes,assess their intra-and interobserver variability,and determine their level of agreement with the established reference.Methods:In this prospective,comparative study,a total of 212 eyes from 212 subjects were enrolled,comprising 137 eyes of patients with glaucoma and 75 eyes of healthy individuals.All participants underwent IOP measurement using the three devices in a randomized order to minimize bias.Based on the initial GAT readings,eyes were systematically classified into one of four predefined IOP levels:Level A(low,<10 mmHg),Level B(normal range,10-21 mmHg),Level C(moderately elevated,>21 to 40 mmHg),and Level D(severely elevated,>40 mmHg).A mixed-model analysis of variance(ANOVA)was employed to statistically analyze the differences in IOP measurements among the three tonometers at each distinct pressure level.The agreement between each pair of devices(CST vs.GAT,CST vs.NCT,and NCT vs.GAT)was meticulously assessed using Bland-Altman plots,which provide metrics for bias(mean difference)and the 95%limits of agreement(LoA).Results:CST and GAT exhibited better intra-and interobserver variability compared to NCT.Significant differences in IOP measurements were observed among CST,NCT,and GAT at levels A and D(P<0.001,P=0.030).Bland-Altman analysis revealed biases between CST and GAT,CST and NCT,and NCT and GAT at different levels(level A:-0.61,0.94,and-1.55 mmHg;level B:0.16,-0.7,and 0.8;level C:0.5,0.5,and-0.1;level D:0.83,-3.4,and 4.2).Notably,NCT tended to overestimate IOP more at higher levels(level D)and underestimate at lower levels(level A)compared to CST.CST demonstrated better agreement with GAT than NCT did.Conclusions:This study confirms that the Corvis ST(CST)shows superior agreement with the Goldmann applanation tonometer than noncontact tonometry,particularly at low and high IOP ranges.It also exhibits greater measurement consistency.While NCT remains a useful screening tool,its significant over-and underestimation at pressure extremes is a critical limitation.The findings strongly suggest that CST may serve as a more suitable and reliable alternative to NCT for measuring IOP across a broad clinical range.However,the results underscore that these three methods are not directly interchangeable.Clinicians must therefore exercise careful interpretation of IOP values,taking into account the specific tonometer used and the patient's probable pressure level for accurate diagnosis and management of glaucoma. 展开更多
关键词 intraocular pressure TONOMETRY goldmann applanation tonometer corvis ST GLAUCOMA
暂未订购
Corvis眼压测量及其与角膜生物力学特性的相关性 被引量:6
4
作者 陈开建 阚秋霞 +4 位作者 白继 张国伟 许多 刘李娜 郎敏 《中华实验眼科杂志》 CAS CSCD 北大核心 2016年第2期166-169,共4页
背景角膜生物力学特性是角膜屈光手术安全评估的重要指标。Corvis是测量角膜生物力学特性的新型设备。目的观察角膜厚度、Corvis眼压测量值与角膜生物力学特性的相关性。方法采用前瞻性观察研究,纳入2013年8月至2014年2月在第三军医大... 背景角膜生物力学特性是角膜屈光手术安全评估的重要指标。Corvis是测量角膜生物力学特性的新型设备。目的观察角膜厚度、Corvis眼压测量值与角膜生物力学特性的相关性。方法采用前瞻性观察研究,纳入2013年8月至2014年2月在第三军医大学大坪医院野战外科研究所眼科拟行准分子角膜屈光术患者75例150眼,根据患者角膜厚度分为3个组:低角膜厚度组:角膜厚度501~530μm;中角膜厚度组:角膜厚度531~560μm;高角膜厚度组:角膜厚度561~590μm;每组25例50眼。采用单因素方差分析比较3个组间眼压、角膜厚度和角膜变形幅度(DA)的差异性。采用多元线性回归分析各组内DA与角膜厚度、眼压的相关性。结果低角膜厚度组与中角膜厚度组DA显著高于高角膜厚度组,差异具有统计学意义(P〈0.05)。3个组间眼压总体比较差异具有统计学意义(F=9.98,P〈0.05)。DA与眼压呈高度负相关(r=-0.84,P〈0.01),与角膜厚度呈负相关(r=-0.33,P〈0.01)。线性回归方程:DA=1.69—0.04×眼压(F=366.19,P〈0.05;t=-19.14,P〈0.01)。结论角膜屈光手术安全性的评估不能单纯以角膜厚度代替角膜生物力学特性,需参考眼压等因素的影响。 展开更多
关键词 corvis 角膜生物力学 角膜厚度 眼压 角膜屈光手术
暂未订购
近视患者Corvis ST角膜生物力学参数与眼部其他生物测量参数的相关分析 被引量:13
5
作者 王丹 王晓睿 +2 位作者 韦伟 裴澄 米生健 《眼科新进展》 CAS 北大核心 2021年第4期354-358,共5页
目的分析近视患者Corvis ST测得的角膜生物力学参数与眼部其他生物测量参数的相关性。方法收集自2019年3月至12月于西安交通大学第一附属医院眼科就诊,拟行角膜屈光手术的192例近视患者的临床资料,全部选择右眼进行研究;年龄18~51岁,Cor... 目的分析近视患者Corvis ST测得的角膜生物力学参数与眼部其他生物测量参数的相关性。方法收集自2019年3月至12月于西安交通大学第一附属医院眼科就诊,拟行角膜屈光手术的192例近视患者的临床资料,全部选择右眼进行研究;年龄18~51岁,Corvis ST测得的眼压为13~17 mmHg(1 kPa=7.5 mmHg),等效球镜度(SE)为-1.50~-11.62 D。研究纳入Corvis ST测量的角膜变形基础参数包括第一次压平速率(A1V)、第一次压平长度(A1L)、第一次压平时间(A1T)、第二次压平速率(A2V)、第二次压平长度(A2L)、第二次压平时间(A2T)、最大压陷时间(HCT)、最大压陷曲率半径(HCR)、最大压陷时两峰间距离(PD);整合参数包括2 mm处变形幅度的比值(DA 2 ratio)、综合半径(IR)、最薄点厚度/厚度变化率(ARTh)、第一次压平时角膜硬度参数(SP-A1)、Corvis生物力学指数(CBI)和生物力学/断层扫描地形图指数(TBI)。眼部其他生物测量参数包括中央角膜厚度(CCT)、SE、眼轴长度(AL)、平均角膜前表面曲率(Km)、角膜水平直径(CD)。使用Spearman相关分析方法评估Corvis ST角膜生物力学参数与眼部其他生物测量参数的相关性。结果CCT与除HCT之外的其他Corvis ST角膜生物力学参数均相关(均为P<0.05);SE与A2L、A2V、PD、HCR、DA 2 ratio、IR均相关(均为P<0.05);AL与A2T、HCT呈负相关,与A2V、PD呈正相关(均为P<0.05);Km与PD、HCR、A2L均呈负相关(均为P<0.05);CD仅与A1V、ARTh、CBI存在弱的相关性(均为P<0.05);CBI仅与CCT、CD相关(均为P<0.05);TBI仅与CCT相关(P<0.001)。结论近视患者Corvis ST角膜生物力学参数与眼部其他生物测量参数存在相关性,在临床应用这些数据时需要综合考虑。 展开更多
关键词 角膜生物力学 corvis ST 角膜水平直径 角膜厚度
暂未订购
Corvis ST角膜生物力学分析仪在青光眼患者中的可重复性研究 被引量:2
6
作者 钱朝旭 黄永健 《齐齐哈尔医学院学报》 2016年第35期4417-4419,共3页
目的评估角膜生物力学眼压分析仪(CST)测量青光眼患者各参数的可重复性。方法选择来本院就诊的25例(25眼)明确诊断为青光眼的病人,由同一位高年资医师用CST测量其两次眼内压(IOP)及角膜生物力学参数,采用Cronbach's Alpha系数及组... 目的评估角膜生物力学眼压分析仪(CST)测量青光眼患者各参数的可重复性。方法选择来本院就诊的25例(25眼)明确诊断为青光眼的病人,由同一位高年资医师用CST测量其两次眼内压(IOP)及角膜生物力学参数,采用Cronbach's Alpha系数及组内相关系数(ICC)分析其可重复性。结果 IOP1、IOP2及角膜地形图CCT的Cronbach's Alpha系数大于0.9,Time1和DA的Cronbach's Alpha系数大于0.7,Time2和Vel1的Cronbach's Alpha系数大于0.6,IOP1、IOP2及角膜地形图(CCT)的ICC系数大于0.8,DA的ICC系数大于0.6。结论 CST的IOP测量重复性较好,部分角膜动力学参数有较好的重复性,可相互替换。 展开更多
关键词 corvis ST 角膜生物力学 眼压 青光眼
暂未订购
应用CorvisST观察抗炎药物对前葡萄膜炎患者角膜生物力学的影响 被引量:2
7
作者 郑学燕 怀斌 张晨明 《国际医药卫生导报》 2016年第6期837-839,共3页
目的应用角膜生物力学分析仪器CorvisST观察抗炎药物对角膜生物力学的影响。方法收集临床中前部葡萄膜炎患者31例,局部应用地塞米松类抗炎药物前后,应用角膜生物力学分析仪器对角膜进行生物力学的测量,观察CorvisSTN量的角膜动态过... 目的应用角膜生物力学分析仪器CorvisST观察抗炎药物对角膜生物力学的影响。方法收集临床中前部葡萄膜炎患者31例,局部应用地塞米松类抗炎药物前后,应用角膜生物力学分析仪器对角膜进行生物力学的测量,观察CorvisSTN量的角膜动态过程的变化值中IOP、CCT、Def.Ampl、P.Dist、Radius等数据,分析抗炎药物对角膜生物力学的影响。结果应用抗炎药物前后角膜P.Dist、Radius差异具有统计学意义(P〈0.05)。结论前部葡萄膜炎患者局部应用抗炎药物后,角膜生物力学可能发生改变,指导临床应用。 展开更多
关键词 角膜生物力学 corvis ST 抗炎类滴眼液
暂未订购
Corvis ST和Pentacam联合诊断系统测量角膜厚度及眼压的临床观察 被引量:5
8
作者 李跃祖 李俊 +2 位作者 张洁莹 马蓉 梁刚 《临床眼科杂志》 2020年第4期341-346,共6页
目的比较Corvis ST和Pentacam联合诊断系统(CP组合)、A型超声角膜厚度测量仪、非接触式眼压计在测量角膜中央最薄点厚度和眼压的差异性。方法前瞻性研究。选取2019年3~6月在云南省第二人民医院进行角膜屈光手术术前检查的患者作为研究对... 目的比较Corvis ST和Pentacam联合诊断系统(CP组合)、A型超声角膜厚度测量仪、非接触式眼压计在测量角膜中央最薄点厚度和眼压的差异性。方法前瞻性研究。选取2019年3~6月在云南省第二人民医院进行角膜屈光手术术前检查的患者作为研究对象,共纳入研究被检者77例(154只眼)。角膜厚度值分别纳入CP组合中Corvis ST角膜顶点厚度值,Pentacam中角膜最薄点厚度值,A型超声角膜测厚仪测量的中央角膜厚度值。眼压分别纳入Corvis ST中直接测量值(IOP)、修正眼压值(BIOP),非接触式眼压计直接测量值(NCT)、联合Pentacam得出的校正眼压值(校正NCT)。厚度数据间差异采用方差分析,眼压数据采用配对t检验,相关性采用Pearson分析,不同检查方法间一致性采用Bland-Altman分析。结果Corvis ST与Pentacam、A型超声超声角膜厚度测量仪所测角膜厚度值组间比较差异有统计学意义(F=3.314,P=0.037);IOP与NCT间、BIOP与校正NCT间比较差异有统计学意义(t=-19.698,P=0.000;t=-15.893,P=0.000)。BIOP与Corvis ST角膜中央厚度无相关性(r=0.088,P=0.259)。Corvis ST与Pentacam、A型超声测量角膜厚度分别有5.56%(8/144)、6.25%(9/144)位于95%一致性界限范围以外;Corvis ST与NCT测量眼压有3.47%(5/144)位于95%一致性界限以外,其中在95%一致性界限内,差值绝对值最大为5.3 mmHg。结论CP组合中Corvis ST对角膜中央厚度值的测量显著高于Pentacam和A型超声测厚仪,Pentacam提供的角膜厚度信息更有意义;Corvis ST对眼压值的测量高于非接触式眼压计,BIOP更能反映眼压真实情况。 展开更多
关键词 corvis ST角膜生物力学分析仪 Pentacam角膜地形图 A型超声角膜厚度测量仪 非接触式眼压计
暂未订购
基于Pentacam和Corvis ST测量近视患者角膜的弹性模量 被引量:4
9
作者 孟乔宇 王晓君 +2 位作者 李晓娜 贺瑞 孟莹 《太原理工大学学报》 CAS 北大核心 2022年第4期721-727,共7页
通过三维眼前节分析仪地形数据建立近视眼角膜几何模型,模拟了可视化角膜生物力学分析仪的检测过程,并与临床实际检测结果进行了对比,逆向求解出20例近视眼角膜弹性模量,弹性模量均值为0.822 MPa±0.146 MPa.根据求解出的近视角膜... 通过三维眼前节分析仪地形数据建立近视眼角膜几何模型,模拟了可视化角膜生物力学分析仪的检测过程,并与临床实际检测结果进行了对比,逆向求解出20例近视眼角膜弹性模量,弹性模量均值为0.822 MPa±0.146 MPa.根据求解出的近视角膜弹性模量,可为建立近视角膜有限元模型提供一定的参考,以期为后续更准确地模拟角膜屈光手术及预测术后角膜力学性能提供理论基础。 展开更多
关键词 角膜 生物力学 PENTACAM corvis ST 有限元模型
暂未订购
Corvis ST评估近视患者角膜生物力学参数及相关影响因素 被引量:7
10
作者 杨丹丹 尹禾 卢丽芳 《国际眼科杂志》 CAS 北大核心 2023年第10期1754-1759,共6页
目的:利用可视化角膜生物力学分析仪(Corvis ST)评估不同近视患者角膜生物力学参数的差异及其与眼部其他生物测量参数的相关性。方法:选取2021-05/12就诊于武汉艾格眼科医院角膜屈光手术科的近视患者132例,均取右眼数据。根据等效球镜度... 目的:利用可视化角膜生物力学分析仪(Corvis ST)评估不同近视患者角膜生物力学参数的差异及其与眼部其他生物测量参数的相关性。方法:选取2021-05/12就诊于武汉艾格眼科医院角膜屈光手术科的近视患者132例,均取右眼数据。根据等效球镜度数(SE)将受检者分为中低度近视(-0.50~-6.00D),高度近视(>-6.00~<-8.00D),超高度近视(≥-8.00D)。使用Corvis ST测量角膜生物力学形变基础参数包括:包括最大变形幅度(DA)、最大压陷反向曲率半径(HCR)、最大压陷峰距(PD);整合参数包括:第一次压平时角膜硬度参数(SP-A1)、综合半径(IR)、2mm处形变幅度的比值(DA ratio)、角膜厚度变异率(ARTh)、Corvis ST生物力学指数(CBI);测量眼部其他生物参数包括:SE、眼压(IOP)、眼轴长度(AL)、中央角膜厚度(CCT)、水平角膜直径(WTW)、视神经纤维层厚度(RNFL)。分别比较三组近视患者角膜生物力学参数的差异,并进一步分析三组近视患者角膜生物力学参数与眼部其他生物测量参数及年龄的相关性。结果:中低度、高度、超高度近视组的SP-A1分别为106.8±16.2、115.6±21.9、106.9±11.5,高度近视组SP-A1高于中低度、超高近视组(均P<0.05)。所有角膜生物力学与CCT均有显著相关性(P<0.01);除ARTh外,其余角膜生物力学与IOP均有相关性(P<0.05);AL与PD呈显著正相关(r=0.270,P=0.002),与HCR呈较弱的正相关(r=0.177,P=0.043),与IR呈较弱的负相关(r=-0.183,P=0.036);WTW与PD、DA、DA ratio均呈正相关(r=0.363,P<0.001;r=0.252,P=0.003;r=0.200,P=0.02);角膜生物力学参数与年龄、SE、RNFL均无相关性。结论:高度近视患者的角膜硬度高于中低度和超高度近视患者,IOP、CCT均为影响角膜生物力学的重要因素。部分生物力学参数和AL、WTW也有一定的相关性,随着眼轴的增长,角膜形变范围PD越大,HCR变大,IR变小,但后两者显著性不强;角膜直径越大,角膜形变幅度越大。临床中需重视超高度近视患者角膜生物力学参数。 展开更多
关键词 角膜生物力学 近视 眼轴长度 可视化角膜生物力学分析仪(corvis ST)
暂未订购
Comparison among Ocular Response Analyzer,Corvis ST and Goldmann applanation tonometry in healthy children 被引量:4
11
作者 Ramin Salouti Ali agha Alishiri +7 位作者 Reza Gharebaghi Mostafa Naderi Khosrow Jadidi Ahmad Shojaei-Baghini Mohammadreza Talebnejad Zahra Nasiri Seyedmorteza Hosseini Fatemeh Heidary 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第8期1330-1336,共7页
AIM: To explore the relationship between different parameters of Ocular Response Analyzer(ORA) and Corvis ST(CST) in a sample of healthy Iranian school-aged children and the relationship between parameters of the... AIM: To explore the relationship between different parameters of Ocular Response Analyzer(ORA) and Corvis ST(CST) in a sample of healthy Iranian school-aged children and the relationship between parameters of these 2 instruments against intraocular pressure(IOP), measured by the Goldmann applanation tonometer(GAT-IOP), age and gender, and find possible correlation between ORA and CST with GAT.METHODS: This cross-sectional study included 90 healthy children. A general interview and complete eye examination were performed. Following successful GATIOP measurement, ORA and CST were conducted. The CST parameters were A 1/2 length(A1 L, A2 L), A 1/2 velocity(A1 V, A2 V), highest concavity deformation amplitude(HCDA), radius of curvature(Ro C), peak distance(PD), central corneal thickness(CCT) and IOP. The ORA parameters were corneal hysteresis(CH), corneal resistance factor(CRF), Goldmann-correlated IOP(IOP-G) and corneal compensated IOP(IOP-CC). Extracted data was analyzed using the Statistical Package for Social Science software.RESULTS: Totally 39 males with age of 9.08±1.60(6-12)y and 51 females with age of 8.96±1.55(6-13)y were included. Many CST parameters were significantly correlated with CH, CRF, IOP-G and IOP-CC. Some CST parameters had a significant correlation with GAT-IOP, including IOP-CST in both eyes and HCDA, A2 L, PD, and RoC in the left eye, but none with age, except A2 L in the right eye. The CRF measurement showed a significant correlation with GAT-IOP in both eyes and CH in the right eye, yet, none with age. Among all CST and ORA parameters, CCT-CST in both eyes and A1 L in right eye had a significant correlation with gender, although this was a negligible negative correlation. Comparison of mean IOP values by different devices showed a significantly highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Also, IOP-G versus IOP-CST significantly had the lowest IOP overestimation among others. Overall, either low positive correlation or negligible correlation was found between IOP measurements by 3 instruments.CONCLUSION: The study finds the highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Overall, either low positive correlation or negligible correlation is found between IOP measurements by the 3 instruments. 展开更多
关键词 Goldmann applanation tonometer OcularResponse Analyzer corvis ST intraocular pressure CHILDREN
原文传递
圆锥角膜快速跨上皮交联手术前后Corvis ST参数的重复性及差异性 被引量:2
12
作者 杨凯丽 顾宇伟 +3 位作者 范棋 徐丽妍 庞辰久 任胜卫 《国际眼科杂志》 CAS 北大核心 2021年第1期1-8,共8页
目的:评估圆锥角膜快速跨上皮交联手术前以及术后1mo Corvis ST参数的重复性及差异性。方法:研究纳入了30例30眼圆锥角膜患者进行分析。圆锥角膜患者术前和术后1mo分别进行三次Corvis ST重复测量。采用组内相关系数(ICC)、克伦巴赫alph... 目的:评估圆锥角膜快速跨上皮交联手术前以及术后1mo Corvis ST参数的重复性及差异性。方法:研究纳入了30例30眼圆锥角膜患者进行分析。圆锥角膜患者术前和术后1mo分别进行三次Corvis ST重复测量。采用组内相关系数(ICC)、克伦巴赫alpha系数(Cronbach'α)、可重复性系数(RC)和变异系数(CV)评估Corvis ST参数的可重复性。采用配对t检验或Wilcoxon秩和检验评估术前与术后Corvis ST参数的差异。结果:术前39个Corvis ST参数中,26个(66.67%)参数重复性较好,6个(15.38%)参数重复性中等,7个(17.95%)参数的重复性较差。交联术后1mo,34个(87.18%)参数的重复性较好,3个(7.69%)参数重复性中等,2个(5.13%)参数的重复性较差。与术前相比,交联术后1mo圆锥角膜患者的眼压、生物力学校正眼压、第一次压平时间、曲率半径、第一次压平时的形变幅度、最大压陷偏离长度、角膜硬度参数值增加;而陡峭曲率、平坦曲率、平均曲率、第二次压平时间、2 mm最大形变幅度比值和综合半径值降低(均P<0.05)。结论:交联手术前和术后1mo Corvis ST参数均具有较好的可重复性,术后1mo圆锥角膜患者的角膜硬度较术前增加。 展开更多
关键词 圆锥角膜 快速跨上皮交联 corvis ST参数 可重复性 早期角膜生物力学改变
在线阅读 下载PDF
Corvis ST新参数应力-应变指数的研究进展
13
作者 叶倩 张红 《国际眼科杂志》 2024年第1期97-100,共4页
可视化角膜生物力学分析仪(Corvis ST)是目前评估在体角膜生物力学最常用的临床设备。新参数应力-应变指数(SSI)是近年来临床研究的热点,其不仅可以直接反映角膜生物材料刚度,而且与某些疾病的进展密切相关。SSI是基于使用有限元(FE)数... 可视化角膜生物力学分析仪(Corvis ST)是目前评估在体角膜生物力学最常用的临床设备。新参数应力-应变指数(SSI)是近年来临床研究的热点,其不仅可以直接反映角膜生物材料刚度,而且与某些疾病的进展密切相关。SSI是基于使用有限元(FE)数值建模模拟眼内压和Corvis ST喷气效果的角膜行为预测生成的。SSI算法不随着本身中央角膜厚度(CCT)、眼内压以及生物力学矫正眼压(BIOP)的变化而变化,但明显与角巩膜中的胶原纤维改变有关。本文将从SSI的原理、年龄与SSI的关系、眼轴与SSI的关系、近视程度与SSI的关系、SSI的应用等方面进行归纳和总结。 展开更多
关键词 可视化角膜生物力学分析仪(corvis ST) 应力-应变指数 年龄 眼轴 近视
暂未订购
基于Corvis ST建立个性化原发性圆锥角膜有限元模型分析 被引量:2
14
作者 孟乔宇 王晓君 孟莹 《兰州工业学院学报》 2023年第2期10-15,共6页
基于角膜地形图建立个性化圆锥角膜几何模型,采用考虑胶原纤维微结构的HGO本构模型,模拟Corvis ST检测过程并结合临床检测结果确定圆锥角膜超弹性本构参数及胶原纤维刚度。结果表明:圆锥角膜胶原纤维刚度(k 1圆锥)与中央厚度(CCT圆锥)... 基于角膜地形图建立个性化圆锥角膜几何模型,采用考虑胶原纤维微结构的HGO本构模型,模拟Corvis ST检测过程并结合临床检测结果确定圆锥角膜超弹性本构参数及胶原纤维刚度。结果表明:圆锥角膜胶原纤维刚度(k 1圆锥)与中央厚度(CCT圆锥)高度相关,两者关系为k 1圆锥=397.042-0.588CCT圆锥。可由圆锥角膜患者中央角膜厚度值估算其纤维刚度,建立与患者实际更相符的圆锥角膜有限元模型,为后期做圆锥角膜相关个性化治疗的仿真模拟研究提供一定的模型参考。 展开更多
关键词 角膜 胶原纤维 corvis ST
在线阅读 下载PDF
Agreement of intraocular pressure measurement with Corvis ST,non-contact tonometer,and Goldmann applanation tonometer in children with ocular hypertension and related factors
15
作者 Hou-Gang Li Yan-Hui Chen +7 位作者 Fang Lin Si-Yu Li Qing-Hua Liu Chun-Ge Yin Xi-Yue Chen Xin-Jie Zhang Yue Qu Yan-Nian Hui 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第10期1601-1607,共7页
AIM:To access the agreement of intraocular pressure(IOP)values obtained from biomechanically corrected tonometer[Corvis ST(CST)],non-contact tonometer(NCT),and Goldmann applanation tonometer(GAT)in children with NCT m... AIM:To access the agreement of intraocular pressure(IOP)values obtained from biomechanically corrected tonometer[Corvis ST(CST)],non-contact tonometer(NCT),and Goldmann applanation tonometer(GAT)in children with NCT measured-IOP(NCT-IOP)values of 22 mm Hg or more,and related factors.METHODS:A total of 51 eyes with NCT-IOP≥22 mm Hg in children aged 7 to 14y were examined and IOP was measured by CST,NCT,and GAT.Based on GAT measured IOP(GAT-IOP),ocular hypertension(OHT)group(≥22 mm Hg,24 eyes)and the non-OHT group(<22 mm Hg,27 eyes)were defined.We compared the agreement of the three measurements,i.e.,CST measured IOP(CST-IOP),GAT-IOP,and NCT-IOP,and further analyzed the correlation between the differences in tonometry readings,central corneal thickness(CCT),axial length(AL),optic disc rim volume,and age.RESULTS:Compared with the OHT group,thicker CCT,larger rim volume,and higher differences between NCTIOP and GAT-IOP,were found in the non-OHT group.The differences between CST-IOP and GAT-IOP were lower than the differences between NCT-IOP and GAT-IOP in both groups.The mean differences in CST-IOP and GAT-IOP were 1.26 mm Hg(95%limit of agreement ranged from 0.1 to 2.41 mm Hg,OHT group)and 1.20 mm Hg(95%limit of agreement ranged from-0.5 to 3.00 mm Hg,non-OHT group),and the mean differences in NCT and GAT were 3.90 mm Hg(95%limit of agreement ranged from-0.19 to 9.70 mm Hg,OHT group)and 6.00 mm Hg(95%limit of agreement ranged from 1.50 to 10.50 mm Hg,non-OHT group).The differences between CST-IOP and GAT-IOP were not related to CCT,age,and AL in both groups;while the differences between NCT-IOP and GAT-IOP were related to CCT in the OHT group(r=0.93,P<0.001)and to CCT and AL in the non-OHT group(r=0.66,P<0.001,r=-0.81,P<0.001).CONCLUSION:The accuracy of NCT in the diagnosis of pediatric OHT is low.The agreement of CST-IOP and GATIOP was significantly higher in children with and without OHT than in those with NCT-IOP and GAT-IOP.Therefore,CST can be used as a good alternative for IOP measurement in children.The impacts of CCT and AL on NCT measurement need to be fully considered when managing childhood IOP. 展开更多
关键词 ocular hypertension CHILDREN non-contact tonometer Goldmann applanation tonometer corvis ST corneal biomechanics central corneal thickness axial length
原文传递
Corvis ST测量青光眼患者眼压及中央角膜厚度的准确性研究 被引量:4
16
作者 钱朝旭 黄永健 《中华眼视光学与视觉科学杂志》 CAS CSCD 2017年第6期345-349,共5页
目的:评估角膜生物力学分析仪(CST)测量青光眼患者眼压(IOP)及中央角膜厚度(CCT)的准确性,研究角膜生物力学参数对IOP的影响。方法:描述性研究。28 例(56 眼)明确诊断为青光眼的患者,由同一位高年资医师分别用CST及Goldman... 目的:评估角膜生物力学分析仪(CST)测量青光眼患者眼压(IOP)及中央角膜厚度(CCT)的准确性,研究角膜生物力学参数对IOP的影响。方法:描述性研究。28 例(56 眼)明确诊断为青光眼的患者,由同一位高年资医师分别用CST及Goldmann压平眼压计(GAT)测量其IOP,采用CST和IOLMaster测量CCT。不同设备测量值比较采用配对t 检验,相关性分析采用非参数Spearman检验,一致性验证采用Bland-Altman检验。结果:CST与GAT测得IOP平均值分别为(19.5±12.0)mmHg(1 mmHg=0.133 kPa)、 (20.9±8.8)mmHg,差异无统计学意义;CST与IOLMaster测得CCT平均值分别为(544±40)μm、 (538±40)μm,差异无统计学意义。CST与GAT测得的IOP具有高度相关性(ρ=0.837,P <0.001),CST与IOLMaster测得的CCT具有高度相关性(ρ=0.958,P <0.001)。GAT与CST测得的IOP差值均值为(1.3±5.4)mmHg,95%的一致性界限为(-9.3,12.0)mmHg,IOLMaster与CST测得的CCT差 值均值为(6±10)μm,95%的一致性界限为(-26,15)μm。结论:CST可获得精确的IOP与CCT,但CST测量的IOP稍低于GAT,在青光眼的诊治中不能完全替代GAT. 展开更多
关键词 corvis ST 角膜生物力学 眼压 中央角膜厚度 青光眼
原文传递
圆锥角膜生物力学在Corvis ST与ORA下的变化特点 被引量:1
17
作者 李勇 魏升升 +5 位作者 李晶 刘建国 叶璐 万雅群 李娟 杜婧 《中国实用眼科杂志》 2015年第8期881-884,共4页
目的应用可视化角膜生物力学分析仪(corneal visualization scheimpflug technology,Corvis ST)和眼反应分析仪(ocular response analyze,ORA)分析圆锥角膜生物力学变化,并与正常角膜作对照,总结圆锥角膜生物力学变化特点。方... 目的应用可视化角膜生物力学分析仪(corneal visualization scheimpflug technology,Corvis ST)和眼反应分析仪(ocular response analyze,ORA)分析圆锥角膜生物力学变化,并与正常角膜作对照,总结圆锥角膜生物力学变化特点。方法临床病例对照研究。选取2009年3月至2014年6月在西安市第四医院眼科就诊的患者,应用角膜生物力学眼压分析仪(Corvis ST)和眼反应分析仪(ORA)分别对34例(42只眼)圆锥角膜和61例(61只眼)正常角膜进行生物力学的测量。应用Corvis ST测定角膜的第一次压平长度(1stA length);第一次压平速率(Vin);第二次压平长度(2ndA length);第二次压平速率(Vout);角膜最大变形幅度(Def.Ampl);顶点距离(P.Dist)和曲率半径(Radius)。用眼反应分析仪ORA测定圆锥角膜及正常角膜CH和CRF。采用独立样本t检验或两独立样本非参数检验对圆锥角膜与正常角膜的ORA和Corvis ST的测量所得多项指标进行对比分析。采用Pearson或Spearman相关分析Corvis ST与ORA测量生物力学参数之间相关性。结果:与正常角膜对比,圆锥角膜生物力学指标Corvis ST测量结果中,第一次压平长度、曲率半径下降,差异有统计学意义(t=-0.51,-6.54;P=0.01,0.00);第二次压平速率绝对值、角膜最大变形幅度升高,差异有统计学意义(Z=-2.25,t=4.27;P=0.03,0.00)。圆锥角膜生物力学指标ORA测量结果中角膜滞后量(CH)、角膜阻力因数(CRF)与正常角膜相比均下降,有统计学意义(t=-5.20,-7.06;P=0.00,0.00)。ORA测量CH与Corvis ST测量第一次压平长度、第二次压平速率、角膜最大变形幅度、曲率半径,差异有统计学意义(r=-0.75,-0.54,-0.39,0.51;P=0.00,0.04,0.03,0.00);ORA测量CRF与Corvis ST测量第一次压平长度、第二次压平速率、角膜最大变形幅度、曲率半径亦差异有统计学意义(r=0.36—0.58,-0.61,0.55;P=0.02,0.03,0.00,0.00)。结论圆锥角膜较正常角膜生物力学改变明显,各项参数均有改变。可视化角膜生物力学分析仪(Corvis ST)和眼反应分析仪(ORA)均能较好反映圆锥角膜生物力学改变特点,多项参数具有明显的相关性。 展开更多
关键词 圆锥角膜 生物力学 corvis ST ORA
原文传递
基于Corvis ST医学影像的角膜轮廓提取算法 被引量:3
18
作者 李康生 刘凤连 +2 位作者 吴剑武 刘艳 汪日伟 《光电子.激光》 CAS CSCD 北大核心 2023年第2期208-213,共6页
目前已有的轮廓提取算法在提取可视化角膜生物力学分析仪(corneal visualization scheimpflug technology, Corvis ST)影像的角膜轮廓中,由于角膜边缘的局部图像灰度分布相近这一特点,提取出的角膜轮廓普遍不完整或者提取的角膜轮廓边... 目前已有的轮廓提取算法在提取可视化角膜生物力学分析仪(corneal visualization scheimpflug technology, Corvis ST)影像的角膜轮廓中,由于角膜边缘的局部图像灰度分布相近这一特点,提取出的角膜轮廓普遍不完整或者提取的角膜轮廓边缘出现细小突出。这会使得角膜轮廓的完整性遭到破坏,提取到的角膜轮廓与实际的角膜原始图像严重不符。本文针对Corvis ST采集的角膜图像的轮廓提取问题,基于最大类间方差法(OTSU)算法设计一种高效的图像处理方法。首先,将角膜图像进行除杂、灰度化以及图像降噪等处理,达到减少图像计算量和降低数字图像噪声干扰的目的;其次,基于OTSU算法对图像进行分割,并在此基础上加入数学形态学运算,达到平滑图像边界和填充细小“孔洞”的目的;最后,采用Canny边缘检测算法提取图像中的角膜轮廓,达成提取出高完整性角膜轮廓的目的。在相同的图像数据集上,与最新的纽扣轮廓瑕疵检测系统中设计的轮廓提取算法(B-OTSU algorithm)进行了对比实验。实验结果表明,从轮廓完整性以及准确性的角度,应用本文方法提取的角膜轮廓明显优于最新的纽扣轮廓瑕疵检测系统中的B-OTSU算法提取的角膜轮廓。 展开更多
关键词 图像算法 轮廓提取 corvis ST影像 角膜轮廓
原文传递
应用Corvis ST新参数分析圆锥角膜生物力学特性 被引量:6
19
作者 肖明 张晓宇 王曙亮 《中华眼视光学与视觉科学杂志》 CAS CSCD 2021年第9期641-646,共6页
目的:应用可视化角膜生物力学分析仪(Corvis ST)新参数分析临床期圆锥角膜、亚临床期圆锥角膜及正常角膜的生物力学特性,评价其在圆锥角膜诊断中的价值。方法:病例对照研究。选取2019年1月至2021年1月在襄阳爱尔眼科医院就诊的圆锥角膜... 目的:应用可视化角膜生物力学分析仪(Corvis ST)新参数分析临床期圆锥角膜、亚临床期圆锥角膜及正常角膜的生物力学特性,评价其在圆锥角膜诊断中的价值。方法:病例对照研究。选取2019年1月至2021年1月在襄阳爱尔眼科医院就诊的圆锥角膜患者68例(68眼),其中亚临床期圆锥角膜(SKC)28例(28眼)为SKC组,临床期圆锥角膜(CKC)40例(40眼)为CKC组;选取同一时间段在本院屈光手术中心接受角膜屈光手术的近视患者60例(60眼)作为对照组。使用Corvis ST进行检测,分析变形幅度比(DAR)、综合半径(IR)、水平方向Ambrosio相关厚度(ARTh)、硬度参数(SP-A1)、Corvis生物力学指数(CBI)等参数。采用方差分析、Kruskal-Wallis H检验、Mann-Whitney U检验对数据进行统计分析,绘制受试者工作特征曲线(AUC)。结果:SKC组的IR、CBI高于对照组,差异有统计学意义(U=2.461,P=0.042;U=2.450,P=0.043),2组的DAR、ARTh、SP-A1差异无统计学意义;CKC组的DAR、IR、CBI均高于对照组,差异有统计学意义(U=7.645,P<0.001;U=8.477,P<0.001;U=8.965,P<0.001),但ARTh、SP-A1低于对照组(U=-8.593,P<0.001;U=-7.517,P<0.001)。在SKC组,IR、CBI具有较好诊断效率,其AUC分别为0.669(敏感度为50.0%、特异度为77.5%)、0.656(敏感度为67.9%、特异度为60.0%)。在CKC组,DAR、IR、CBI具有良好诊断效率,其AUC分别为0.956(敏感度为90.0%、特异度为93.3%)、0.968(敏感度为92.5%、特异度为91.7%)、1.000(敏感度为100.0%、特异度为100.0%)。结论:SKC生物力学特性较健康角膜部分参数有改变,其中IR、CBI对SKC具有较好的诊断效率;CKC生物力学特性较健康角膜明显改变,其中DAR、IR、CBI对KC均具有良好的诊断效率。 展开更多
关键词 corvis ST 圆锥角膜 角膜生物力学 新参数
原文传递
Corvis ST检测在体角膜生物力学性能的有限元模拟 被引量:3
20
作者 孟乔宇 王晓君 +2 位作者 陈维毅 李晓娜 贺瑞 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2020年第4期608-613,共6页
角膜的刚度降低是导致圆锥角膜的关键因素,角膜中胶原纤维刚度和纤维分散程度与角膜生物力学性能密切相关。本文通过建立基于角膜微结构即考虑胶原纤维的准分子激光原位角膜磨镶术(LASIK)术前和术后人眼角膜有限元模型,模拟了可视化角... 角膜的刚度降低是导致圆锥角膜的关键因素,角膜中胶原纤维刚度和纤维分散程度与角膜生物力学性能密切相关。本文通过建立基于角膜微结构即考虑胶原纤维的准分子激光原位角膜磨镶术(LASIK)术前和术后人眼角膜有限元模型,模拟了可视化角膜生物力学分析仪的检测过程,并与临床实际检测结果对比,确定屈光手术前后人眼角膜材料的超弹性本构参数及角膜胶原纤维刚度模量。研究发现LASIK术后,角膜胶原纤维刚度模量较术前明显增大,并与中央角膜厚度(CCT)高度相关;术前术后角膜胶原纤维刚度模量与对应中央角膜厚度的预测关系分别为:k1术前=exp(9.14-0.009CCT术前),k1术后=exp(8.82-0.008CCT术后)。根据本文的研究结果,可由患者的中央角膜厚度值估算其术前术后胶原纤维刚度模量,进而建立与患者实际情况更相符的个性化角膜模型,为更准确地预测角膜安全手术切削量提供理论参考。 展开更多
关键词 角膜 生物力学 corvis ST 有限元模型 准分子激光原位角膜磨镶术
原文传递