期刊文献+
共找到32篇文章
< 1 2 >
每页显示 20 50 100
Impact of Crosswind on Steady-State and Dynamic Performance of Natural Draft Dry Cooling Tower Group:A Numerical Analysis
1
作者 Xuhui Jiang Xi Zhang +4 位作者 Song Wang Ruiqiong Wang Peng Zou Jingzhou Lu Xiaoxiao Li 《Frontiers in Heat and Mass Transfer》 EI 2024年第1期193-216,共24页
This study investigates the performance of a natural draft dry cooling tower group in crosswind conditions through numerical analysis.A comprehensive three-dimensional model is developed to analyze the steady-state an... This study investigates the performance of a natural draft dry cooling tower group in crosswind conditions through numerical analysis.A comprehensive three-dimensional model is developed to analyze the steady-state and dynamic behavior of the towers.The impact of wind speed and direction on heat rejection capacity and flow patterns is examined.Results indicate that crosswinds negatively affect the overall heat transfer capacity,with higher crosswind speeds leading to decreased heat transfer.Notably,wind direction plays a significant role,particularly at 0°.Moreover,tower response time increases with higher crosswind speeds due to increased turbulence and the formation of vortices.The response times are generally similar for wind directions of 45°and 90°,but differ when facing 0,where the leeward tower exhibits a shorter response time compared to the windward tower.These findings provide valuable insights into the performance of natural draft dry cooling tower groups under crosswind conditions,which can inform the design and operation of similar systems in practical applications. 展开更多
关键词 Natural draft dry cooling tower group CROSSWIND dynamic characteristics
在线阅读 下载PDF
Wind-induced responses of super-large cooling towers 被引量:3
2
作者 柯世堂 葛耀君 +2 位作者 赵林 陈少林 Y.Tamura 《Journal of Central South University》 SCIE EI CAS 2013年第11期3216-3228,共13页
Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formula... Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formulas of fluctuating wind-induced responses and equivalent static wind loads(ESWLSs)were derived based on structural dynamics and random vibration theory.The consistent coupled method(CCM)was presented to compensate the coupled term between background and resonant response.Taking the super-large cooling tower(H=215 m)of nuclear power plant in Jiangxi Province,China,which is the highest and largest in China,as the example,based on modified equivalent beam-net design method,the aero-elastic model for simultaneous pressure and vibration measurement of super-large cooling tower is firstly carried out.Then,combining wind tunnel test and CCM,the effects of self-excited force on the surface pressures and wind-induced responses are discussed,and the wind-induced response characteristics of background component,resonant component,coupled term between background and resonant response,fluctuating responses,and wind vibration coefficients are discussed.It can be concluded that wind-induced response mechanism must be understood to direct the wind resistant design for super-large cooling towers. 展开更多
关键词 super-large cooling towers wind-induced responses wind vibration coefficients aero-elastic model consistent coupled method
在线阅读 下载PDF
NUMERICAL INVESTIGATION OF THE ADVERSE EFFECT OF WIND ON THE HEAT TRANSFER PERFORMANCE OF TWO NATURAL DRAFT COOLING TOWERS IN TANDEM ARRANGEMENT 被引量:2
3
作者 符松 翟志强 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2001年第1期24-34,共11页
This article reports the findings on the adverse effect of the crosswind on the performance of natural draft cooling towers through numerical computation with the k-epsilon eddy-viscosity turbulence model. It is obser... This article reports the findings on the adverse effect of the crosswind on the performance of natural draft cooling towers through numerical computation with the k-epsilon eddy-viscosity turbulence model. It is observed here that the cause of the adverse effect of the crosswind on the cooling towers call be attributed to the around flow effect which destroys the radial inflow into the cooling towers when the wind is absent. Hence, a significant deterioration in the heat transfer from the heat exchangers at lateral sides occurs. 展开更多
关键词 natural draft cooling tower buoyancy flow CROSSWIND k-epsilon model
在线阅读 下载PDF
Collapse Simulation and Response Assessment of a Large Cooling Tower Subjected to Strong Earthquake Ground Motions 被引量:2
4
作者 Tiancan Huang Hao Zhou Hamid Beiraghi 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第5期691-715,共25页
Large cooling towers in thermal power plants and nuclear power plants are likely to suffer from strong earthquakes during service periods.The resulting destructions of the cooling towers would endanger the power plant... Large cooling towers in thermal power plants and nuclear power plants are likely to suffer from strong earthquakes during service periods.The resulting destructions of the cooling towers would endanger the power plants and threaten the security of the related areas.It is important to use effective means to evaluate the safety status of the cooling towers and guide further precautions as well as retrofitting efforts.This paper is therefore focused on an elaborate numerical investigation to the earthquake-induced collapses of a large cooling tower structure.A complete numerical work for simulation of material failure,component fracture,structural buckling and system collapse is presented by integrating the stochastic damage constitutive model of concrete,refined structural element models,and some other key techniques.Numerical results indicate that the damage behavior and collapse mode of the cooling tower are affected notably by the randomness specification of ground motions.The collapse mechanisms of the cooling tower are studied from the energy absorption and dissipation points of view.An effective energy-based criterion is introduced to identify the collapse of the cooling tower under ground motion excitations.While distinct collapse modes are observed,the collapse criterion can predict well the damage and failure of the cooling tower.The proposed methodology is vital to better understanding the disastrous mechanisms and potential failure paths in optimal design of the cooling towers to ensure safety. 展开更多
关键词 cooling tower CONCRETE damage mechanics collapse criterion RESPONSES
在线阅读 下载PDF
A reversibly used cooling tower with adaptive neuro-fuzzy inference system 被引量:2
5
作者 吴加胜 张国强 +3 位作者 张泉 周晋 郭永辉 沈炜 《Journal of Central South University》 SCIE EI CAS 2012年第3期715-720,共6页
An adaptive neuro-fuzzy inference system(ANFIS) for predicting the performance of a reversibly used cooling tower(RUCT) under cross flow conditions as part of a heat pump system for a heating mode in winter was demons... An adaptive neuro-fuzzy inference system(ANFIS) for predicting the performance of a reversibly used cooling tower(RUCT) under cross flow conditions as part of a heat pump system for a heating mode in winter was demonstrated.Extensive field experimental work was carried out in order to gather enough data for training and prediction.The statistical methods,such as the correlation coefficient,absolute fraction of variance and root mean square error,were given to compare the predicted and actual values for model validation.The simulation results predicted with the ANFIS can be used to simulate the performance of a reversibly used cooling tower quite accurately.Therefore,the ANFIS approach can reliably be used for forecasting the performance of RUCT. 展开更多
关键词 reversibly used cooling tower HEATING adaptive neuro-fuzzy inference system fuzzy modeling approach
在线阅读 下载PDF
Optimization on Inlet Deflectors Structural Parameters of a Natural Draft Counter-flow Wet Cooling Tower 被引量:1
6
作者 HU Danmei ZONG Tao +1 位作者 ZHANG Zhichao ZHANG Jianping 《中国电机工程学报》 EI CSCD 北大核心 2013年第11期I0005-I0005,共1页
The cooling process of cooling water is veryimportant in power generation industry.The performanceof cooling towers has a great effect on security,stabilityand economy of power plants.The energy savingproblems of the ... The cooling process of cooling water is veryimportant in power generation industry.The performanceof cooling towers has a great effect on security,stabilityand economy of power plants.The energy savingproblems of the cooling tower have always beenneglected previously.With the aim of energy saving inthe power plants nowadays,improving the coolingefficiency of the cooling tower has important andpractical significance. 展开更多
关键词 cooling tower heat and mass transfer DEFLECTOR numerical simulation OPTIMIZATION
原文传递
Wind?Induced Interference Effect Between Newly?Built Cooling Tower and Existing Cooling Tower 被引量:1
7
作者 DU Lin KE Shitang +2 位作者 YANG Jie ZHU Rongkuan GE Yaojun 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2020年第1期88-98,共11页
Disturbance effect is one of the important factors for wind damage to large cooling towers.Existing studies on the wind-induced interference of cooling tower groups are aimed at the same size and the lack of wind-indu... Disturbance effect is one of the important factors for wind damage to large cooling towers.Existing studies on the wind-induced interference of cooling tower groups are aimed at the same size and the lack of wind-induced interference effects between cooling towers of different sizes.With the background of the additional cooling tower project at Shandong Luxi Power Plant in China,the rigid body pressure wind tunnel test is carried out to obtain 194 conditions for the three combinations of the existing four-tower combination(small size),the new two-tower combination(large size)and the six-tower combination surface wind pressure distribution.Numerical simulation of the surrounding flow field of the cooling tower group with the most unfavorable interference condition of the six-tower combination is conducted using the computational fluid dynamics(CFD)method.Based on this,the characteristics of the average and pulsating wind pressure distribution of the cooling tower surface under the six-tower combination are mainly studied,and the load interference coefficients of the large-sized cooling tower and the small-sized cooling tower under the three tower group combinations are compared.The velocity flow field and vorticity changes around the cooling tower group at unfavorable wind angles are analyzed,and the wind-induced interference mechanism between cooling tower groups of different sizes is mainly refined.Research shows that the interference effect between such cooling tower groups of different sizes is much larger than that of cooling tower groups of the same size,which is specifically manifested as the enhancement effect of small-sized cooling towers and the shielding effect of large-sized cooling towers.The interference coefficient of large-sized cooling tower groups increases by 28%,and the interference coefficient of small-sized cooling tower groups decreases by 6.4%.The airflow acceleration caused by the pinch effect between small-sized cooling tower groups has an adverse effect on large-sized cooling towers and can significantly increase the magnitude of local wind load.The shielding effect of large-sized cooling towers can reduce the overall wind load of small-sized cooling towers.The research conclusions can provide the basis of wind load value design for wind resistance design of such large cooling tower addition projects. 展开更多
关键词 cooling tower wind tunnel test wind-induced interference effect mechanism of action numerical simulation
在线阅读 下载PDF
Case Study of Wind-Induced Vibration of a Cooling Tower Under Typhoon Environment
8
作者 XING Yuan ZHAO Lin +1 位作者 CHEN Xu GE Yaojun 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2020年第1期108-119,共12页
As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields ... As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields under the normal wind and typhoon are simulated by active wind tunnel technology,and rigid-pressure-measurement model and aero-elastic-vibration-measurement model of a large cooling tower are built.The stagnation point,peak suction point,separation point and leeward point of the throat position shell are selected to analyze pressure coefficient,probability distribution,peak factor,power spectral density and dynamic amplification factor under normal wind and typhoon.It is clarified that there exists a significant non-Gaussian characteristic under typhoon condition,which also exists in structural response level.Resonance response ratio of the total response is higher during typhoon condition.The maximum value of dynamic amplification coefficient under typhoon field is up to 1.18 times over that under normal wind.The findings of this study are expected to be of interest and practical use to professional and researchers involved in the wind-resistant designs of super-large cooling towers in typhoon prone regions. 展开更多
关键词 cooling towers active wind tunnel non-Gaussian characteristic wind-induced vibration dynamic amplification coefficient
在线阅读 下载PDF
Updating empirical results of wind loads on cooling towers for turbulence intensity effects
9
作者 Cheng Xiaoxiang 《Journal of Southeast University(English Edition)》 EI CAS 2021年第4期413-420,共8页
Variations of wind effects on large cooling towers observed at different turbulence intensities for our previous full-scale measurements might be caused by the inherent uncertainties in our physical experiments.Accord... Variations of wind effects on large cooling towers observed at different turbulence intensities for our previous full-scale measurements might be caused by the inherent uncertainties in our physical experiments.Accordingly,the one-way analysis of variance(ANOVA)technique is employed for analyzing the data measured on the prototype Pengcheng cooling tower.Because ANOVA indicates that the variations of full-scale wind effects are basically the effects of turbulence intensity,the empirical results of wind loads on cooling towers obtained by generalizing physical experimental data without considering the turbulence intensity effects are updated using model test results obtained in multiple flow fields.The empirical fluctuating wind pressure distribution is updated based on the fact that the fluctuating wind pressure coefficient linearly increases with the increase in the turbulence intensity,and the empirical formulae of the spectra and the coherences is updated based on conservative assumptions.Comparisons of the empirical results and full-scale measurement data suggest that the original empirical results are either too conservative or unsafe for use.However,economic efficiency and conservativeness will be balanced if the updated empirical results are employed for the wind engineering design. 展开更多
关键词 cooling tower empirical formula wind tunnel test full-scale measurement turbulence intensity
在线阅读 下载PDF
Experimental Study on the Resistance and Splash Performances of Water Collecting Devices for Mechanical Draft Cooling Towers
10
作者 Guoqing Long Guogang Zhang +3 位作者 Qi Zhang Cuilin Zhao Suoying He Fengzhong Sun 《Fluid Dynamics & Materials Processing》 EI 2023年第7期1789-1801,共13页
In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To ex... In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To explore the feasibility of this approach for mechanical draft cooling towers,a small-scale experimental device has been built to study the resistance and splash performances of three U-type water collecting devices(WCDs)for different water flow rates and wind speeds.The experimental results show that within the considered ranges of wind speed and water flow rate,the pressure drop of the different WCDs can vary significantly.The resistance and local splash performances can also be remarkably different.Some recommendations about the most suitable system are provided.Moreover,a regression analysis of the experimental data is conducted,and the resulting fitting formulas for resistance and splash performance of WCD are reported. 展开更多
关键词 Mechanical draft cooling towers water collecting device resistance performance splash performance fitting formulas
在线阅读 下载PDF
Spray Effect on the Thermal Performances of a Dry Cooling Tower
11
作者 Zhe Geng Feng Feng +5 位作者 Shuzhen Zhang Jie Li Chengwei Liu Yang Li Tiantian Liu Suoying He 《Fluid Dynamics & Materials Processing》 EI 2023年第9期2289-2304,共16页
Pre-cooling the inlet air of a dry cooling tower by means of a spray can improve the tower performance during periods of high temperature.To study the spray effect on the thermal performance of natural draft dry cooli... Pre-cooling the inlet air of a dry cooling tower by means of a spray can improve the tower performance during periods of high temperature.To study the spray effect on the thermal performance of natural draft dry cooling towers(NDDCTs),in this study 3-D numerical simulations of such a process have been conducted using Fluent 16.2(a two-way coupled Eulerian-Lagrangian approach).The considered NDDCT is 120 m high and only half system is simulated due to its structural symmetry.Three different spray strategies have been investigated at a typical crosswind speed of 4 m/s,which is the most frequent wind speed.The results have shown that:(1)The three implemented spray strategies can improve the thermal performance of the studied NDDCT with a vary-ing degree of success.In one case,the heat rejection rate can be increased by 35.2%,and the tower outlet water temperature can be decreased by 2.1℃ when compared with the no spray case;(2)To improve the thermal per-formance of the NDDCT using a small amount of water,the design of the spray pre-cooling system must include more nozzles on the windward and fewer or even no nozzles on the leeward sides of the NDDCT. 展开更多
关键词 Natural draft dry cooling tower spray strategy thermal performance SIMULATION
在线阅读 下载PDF
BUCKLING OF COOLING TOWER SHELLS WITH RING-STIFFENERS
12
作者 卢文达 顾皓中 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1989年第7期583-592,共10页
With the stability analysis of hyperbolic cooling tower shells with ring-stiffeners. our paper proposes the linear pre-buckling consistent theory. The numerical result shows that this linear analysis method is very ef... With the stability analysis of hyperbolic cooling tower shells with ring-stiffeners. our paper proposes the linear pre-buckling consistent theory. The numerical result shows that this linear analysis method is very effective and practical in engineering, for its precision of compulation is up to the level of the nonlinear analysis when it is used for the study of critical loads of the hyperbolic cooling tower which is mainly governed by wind pressure and for the study of the effect of some oilier factors concerned in design on the buckling of shells. Based on that, we have obtained a scries of conclusions whicii will greatly benefits the engineering design when discussing the effect on the critical windloading of the shell which is caused by the following factors such as the position of rings, the number of rings and the dead weight. 展开更多
关键词 BUCKLING OF cooling tower SHELLS WITH RING-STIFFENERS MODE
在线阅读 下载PDF
Thermodynamic Analysis of Double Effect Absorption System along with Boiler and Cooling Tower
13
作者 Saeed Sedigh Hamid Saffari Hamidreza Taleshbahrami 《Journal of Environmental Science and Engineering(A)》 2012年第2期261-270,共10页
Many researchers have studied single and double effect absorption cycles based on first and second lows of thermodynamics But so far the relation of different parameters inside these cycles to the second law of thermo... Many researchers have studied single and double effect absorption cycles based on first and second lows of thermodynamics But so far the relation of different parameters inside these cycles to the second law of thermodynamics in boiler and cooling tower has not been investigated. In this paper, a system comprised of a series flow double effect water-Lithium bromide absorption chiller, a boiler and a cooling tower is studied based on the first and second laws of thermodynamics, and also exergy analysis is investigated. For this purpose, mass and energy conservation laws governing the system are written, and coefficient of performance of the system, exergy destruction (loss) of each component and exergy efficiency have been calculated. 展开更多
关键词 Absorption chiller thermodynamic analysis cooling tower.
在线阅读 下载PDF
Bacterial Colonization and Occurrence of Legionella in Cooling Towers of Southern General Company for Fertilizer Production in Basrah City
14
作者 Hadeel T. Al-Hadithi Jundi A. Mehdi 《Journal of Life Sciences》 2011年第10期789-793,共5页
Sixty six water samples were collected from inlets, inside and outlets of cooling towers (22 samples each, once a week). Samples were screened for bacterial colonization with special focus on Legionella. Percentage ... Sixty six water samples were collected from inlets, inside and outlets of cooling towers (22 samples each, once a week). Samples were screened for bacterial colonization with special focus on Legionella. Percentage occurrence of predominant bacteria present in water samples collected from inlets included: Klebsiella (95.45%), Enterobacter (90.9%), Pseudomonas (86.36%), Escherichia coli (81.81%), and Legionella (72.72%). While those predominant in water inside cooling towers were: Pseudomonas (100%), Staphylococci (81.81%), Legionella (81.81%) and Bacillus (72.72%). Incidence of Legionella recovered from inside and outlets of cooling towers sites was similar. Four species of Legionella were identified in water samples collected from inlets, inside and outlets of cooling towers, in the following consecutive frequencies L. pneumophila (72.72%, 81.81% and 81.81%), L. jordans (18.18%, 36.36% and 27.27%), L. dumffii (9.09%, 22.72% and 22.72%) and L. oekidegenes (4.54%, 13.63% and 18.18%). The increased percentage occurrence of Legionella in water collected from inlets and inside cooling towers, as well as those of Pseudomonas and Staphylococci suggest that Legionella is also a hardy organism, being potentially survive as free organism despite water disinfection. 展开更多
关键词 Bacterial colonization LEGIONELLA L. pneumophila cooling towers.
在线阅读 下载PDF
NONLINEAR BUCKLING ANALYSIS OF HYPERBOLIC COOLING TOWER SHELL WITH RING-STIFFENERS
15
作者 李龙元 卢文达 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1989年第2期113-118,共6页
This paper is concerned with a numerical solution of hyperbolic cooling tower shell, a class of full nonlinear problems in solid mechanics of considerable interest in engineering applications. In this analysis, the po... This paper is concerned with a numerical solution of hyperbolic cooling tower shell, a class of full nonlinear problems in solid mechanics of considerable interest in engineering applications. In this analysis, the post-buckling analysis of cooling tower shell with discrete fixed support and under the action of wind loads and dead load is studied. The influences of ring-stiffener on instability load are also discussed. In addition, a new solution procedure for nonlinear problems which is the combination of load increment iteration with modified R-C are-length method is suggested. Finally, some conclusions having important significance for practice engineering are given. 展开更多
关键词 NONLINEAR BUCKLING ANALYSIS OF HYPERBOLIC cooling tower SHELL WITH RING-STIFFENERS
在线阅读 下载PDF
A New Water Saving Device of Swirling Flow for Cooling Towers
16
作者 Xu Yongjun 1 , E Xuequan, Kan Changzhen Key Laboratory for Hydrodynamics and Ocean Engineering, Institute of Mechanics, Chinese Academy of Sciences 《Electricity》 2011年第4期52-57,共6页
This paper is concerned with water saving for water-loop cooling tower system in power plants. A newly developed water saving device of swirling flow is presented. The key point is that the new water saving device mak... This paper is concerned with water saving for water-loop cooling tower system in power plants. A newly developed water saving device of swirling flow is presented. The key point is that the new water saving device makes the steam swirl up along the device wall rather than engender laminar flow in a corrugated plate. The corrugated plate device can save approximately 10 percent of the total lost water. In contrast to the scale model of corrugated plate water saving device, experimental analyses have demonstrated that the new water saving device of swirling flow is more efficient, with a capacity of saving more than 20 percent of water. 展开更多
关键词 cooling tower water saving swirling flow power plant
在线阅读 下载PDF
Technical Research on Process Optimization of Cooling Tower in Circulating Water System
17
作者 LIANG Jin 《外文科技期刊数据库(文摘版)工程技术》 2021年第7期269-271,共5页
Since the treatment of circulating water will directly affect the discharge of chemical enterprises, the treatment of circulating water is an important link in the development of chemical enterprises, and the cooling ... Since the treatment of circulating water will directly affect the discharge of chemical enterprises, the treatment of circulating water is an important link in the development of chemical enterprises, and the cooling tower is the decisive factor to determine the temperature of circulating water. Therefore, it is necessary to analyze the problems existing in the cooling tower, and put forward corresponding countermeasures for the problems existing in the operation of circulating water cooling tower, so as to explore a reasonable solution. 展开更多
关键词 energy consumption circulating water cooling tower OPTIMIZATION
原文传递
Influence of Crosswind on Evaporation Mass Transfer and Heat Exchange in High-Level Water-Collecting Natural-Draft Wet Cooling Towers
18
作者 ZHANG Lei ZHOU Jun +1 位作者 YUAN Wei ZUO Simeng 《Journal of Thermal Science》 2025年第3期1060-1072,共13页
High-level water-collecting natural-draft wet cooling towers(HNDWCTs)are commonly employed in super-large thermal and nuclear power units.However,research on the effects of crosswinds is still in the exploratory stage... High-level water-collecting natural-draft wet cooling towers(HNDWCTs)are commonly employed in super-large thermal and nuclear power units.However,research on the effects of crosswinds is still in the exploratory stage.This paper focuses on the fill packing zone and investigates the influence of various crosswind speeds(ranging from 1 m/s to 18 m/s)on convective and evaporation heat transfer processes in the cooling tower.The results indicate that evaporation heat transfer contributes 90%of the total,asserting a predominant role in the thermal performance of the cooling towers.Therefore,this study examines the impact of crosswinds on evaporation mass transfer in HNDWCTs.It has been observed that the"self-reflux"in high humidity region under low wind speeds is the root cause of generating low mass transfer driving force region.As wind speed exceeds 9m/s,the"high-humidity reflux"transitions to"low-humidity reflux",which makes the local mass transfer driving force rise back up,and helps to promote the evaporation mass transfer process.This transition mitigates the negative impact of crosswinds,resulting in the stabilization of the evaporation mass transfer and heat exchange reduction at approximately 60%. 展开更多
关键词 CROSSWIND high-level water collection wet cooling tower evaporation mass transfer thermal performance self-reflux
原文传递
THREE-DIMENSIONAL REGULARITIES OF DISTRIBUTION OF AIR-INLET CHARACTERISTIC VELOCITY IN NATURAL-DRAFT WET COOLING TOWER 被引量:7
19
作者 WANG Kai SUN Feng-zhong ZHAO Yuan-bin GAO Ming SHI Yue-tao 《Journal of Hydrodynamics》 SCIE EI CSCD 2008年第3期323-330,共8页
A model for heat and mass transfer in a natural-draft wet cooling tower was established. Numerical simulation with the κ-ε turbulent model was conducted. Distribution rules of air inlet aerodynamic field were studie... A model for heat and mass transfer in a natural-draft wet cooling tower was established. Numerical simulation with the κ-ε turbulent model was conducted. Distribution rules of air inlet aerodynamic field were studied. Field experiments were done in a cooling tower in power plant, and the test data was compared with the related results. The definition of characteristic air velocity was proposed and its influencing factors, such as the cross-wind velocity and circumferential angle, were quantitatively studied. It can be used to evaluate the performance of cooling tower and to calculate the ventilation quantity and resistance of air inlet. It is also a theoretical basis for cooling tower design and performance optimization. 展开更多
关键词 cooling tower flow field numerical simulation air inlet
原文传递
NUMERICAL SIMULATION OF FLOW FIELDS IN A NATURAL DRAFT WET-COOLING TOWER 被引量:4
20
作者 YANG Xiang-liang SUN Feng-zhong +2 位作者 WANG Kai SHI Yue-tao WANG Nai-hua 《Journal of Hydrodynamics》 SCIE EI CSCD 2007年第6期762-768,共7页
The flow field in the hyperbolic natural draft wet-cooling tower, which has great effects on the economy and security of power plant, was studied through numerical simulation. The mathematical model was established an... The flow field in the hyperbolic natural draft wet-cooling tower, which has great effects on the economy and security of power plant, was studied through numerical simulation. The mathematical model was established and analyzed in order to optimize the cooling-tower and to evaluate its efficiency. Various working conditions were considered and compared with each other, such as the circulating water flux, air temperature and tower resistance. It is concluded that when the cooling-tower runs without wind, there is a vacuum region inside the tower and the pressure rises with the increase of the tower height. Meanwhile, the inner flow field is axisymmetrical. The air velocity achieves its climax at the axis. It is also found that the effect of circulating water temperature is equivalent to that of the water flux. 展开更多
关键词 cooling tower flow field circulation water flux circulation water temperature numerical simulation
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部