AIM: To help clarifying the possibility of connective-tissue diseases in men with penile or testicular prostheses. METHODS: Eight patients underwent inflatable penile prostheses and 15, testicular prostheses consented...AIM: To help clarifying the possibility of connective-tissue diseases in men with penile or testicular prostheses. METHODS: Eight patients underwent inflatable penile prostheses and 15, testicular prostheses consented to the study. Their medical records were reviewed and a follow-up interview and physical and serological examinations were performed. RESULTS: In patients with penile prostheses, there was no abnormal antinuclear antibody (ANA) or IgM elevation. The serum levels of the rheumatoid factor (RF), C4, IgA and IgG were abnormal in one patient, and the levels of erythrocyte sedimentation rate (ESR) and C3, abnormal in two. Four had elevated IgE. In patients with testicular prostheses, there was no abnormal RF, ANA or IgM. The serum levels of ESR and IgA were abnormal in two, and three had abnormal C4, ten abnormal C3, and eleven decreased IgG. All had increased IgE. Men with penile prostheses had higher serum levels of IgG and IgM than those with testicular prostheses (P=0.001, P=0.016, respectively). The rates of abnormal values of IgE and IgG were higher in men with testicular prostheses than in men with penile prostheses (P=0.008, P=0.009, respectively). Physical examination was normal in all patients and nobody had documented symptoms pertinent to connective-tissue diseases. CONCLUSION: Our findings suggest that the risk of connective-tissue diseases is not higher in patients wearing prostheses as the ANA is negative and there is no apparent manifestation suggestive of connective-tissue diseases.展开更多
A piezoelectric immunosensor has been developed for the detection of complement C4. Anti-C4 antibody was immobilized onto the gold electrodes of a 9 MHz AT-cut piezoelectric crystal. The coated crystal with the physic...A piezoelectric immunosensor has been developed for the detection of complement C4. Anti-C4 antibody was immobilized onto the gold electrodes of a 9 MHz AT-cut piezoelectric crystal. The coated crystal with the physical adsorption method to immobilize antibody showed the better results than the polyethyleneimine adhesion, glutaraldehyde cross-linking method with respect to sensitivity and reproducibility. The antibody-bound crystal with the physical adsorption method was successfully used for the detection of human complement C4 in the concentration range of 0.1—10 μg/mL for 40 min incubation time. The immunosensor system had good selectivity, and other materials in human Serum did not interfere the detection remarkably. The crystal could be regenerated nearly 15 times when the bound materials on the crystal surface were eluted by strong acid and strong alkali solutions and subsequently cleaned in a ultrasonic cleaner.展开更多
文摘AIM: To help clarifying the possibility of connective-tissue diseases in men with penile or testicular prostheses. METHODS: Eight patients underwent inflatable penile prostheses and 15, testicular prostheses consented to the study. Their medical records were reviewed and a follow-up interview and physical and serological examinations were performed. RESULTS: In patients with penile prostheses, there was no abnormal antinuclear antibody (ANA) or IgM elevation. The serum levels of the rheumatoid factor (RF), C4, IgA and IgG were abnormal in one patient, and the levels of erythrocyte sedimentation rate (ESR) and C3, abnormal in two. Four had elevated IgE. In patients with testicular prostheses, there was no abnormal RF, ANA or IgM. The serum levels of ESR and IgA were abnormal in two, and three had abnormal C4, ten abnormal C3, and eleven decreased IgG. All had increased IgE. Men with penile prostheses had higher serum levels of IgG and IgM than those with testicular prostheses (P=0.001, P=0.016, respectively). The rates of abnormal values of IgE and IgG were higher in men with testicular prostheses than in men with penile prostheses (P=0.008, P=0.009, respectively). Physical examination was normal in all patients and nobody had documented symptoms pertinent to connective-tissue diseases. CONCLUSION: Our findings suggest that the risk of connective-tissue diseases is not higher in patients wearing prostheses as the ANA is negative and there is no apparent manifestation suggestive of connective-tissue diseases.
基金Project supported by the National Natural Science Foundation of China.
文摘A piezoelectric immunosensor has been developed for the detection of complement C4. Anti-C4 antibody was immobilized onto the gold electrodes of a 9 MHz AT-cut piezoelectric crystal. The coated crystal with the physical adsorption method to immobilize antibody showed the better results than the polyethyleneimine adhesion, glutaraldehyde cross-linking method with respect to sensitivity and reproducibility. The antibody-bound crystal with the physical adsorption method was successfully used for the detection of human complement C4 in the concentration range of 0.1—10 μg/mL for 40 min incubation time. The immunosensor system had good selectivity, and other materials in human Serum did not interfere the detection remarkably. The crystal could be regenerated nearly 15 times when the bound materials on the crystal surface were eluted by strong acid and strong alkali solutions and subsequently cleaned in a ultrasonic cleaner.