期刊文献+
共找到355篇文章
< 1 2 18 >
每页显示 20 50 100
On the Case of Equalities in Comparison Results for Elliptic Equations Related to Gauss Measure
1
作者 Yu Juan TIAN Feng Quan LI 《Journal of Mathematical Research and Exposition》 CSCD 2010年第5期761-774,共14页
In this paper, we deal with a Dirichlet problem for linear elliptic equations related to Gauss measure. For this problem, we study the converse of some inequalities proved by other authors, in the sense that we study ... In this paper, we deal with a Dirichlet problem for linear elliptic equations related to Gauss measure. For this problem, we study the converse of some inequalities proved by other authors, in the sense that we study the case of equalities and show that equalities are achieved only in the "symmetrized" situations. In addition, under other assumptions, we give a different form of comparison results and discuss the corresponding case of equalities. 展开更多
关键词 comparison results equalities REARRANGEMENTS Gauss measure elliptic equation.
在线阅读 下载PDF
Comparison of result between the ELISAS/CO values and western blotassay
2
《中国输血杂志》 CAS CSCD 2001年第S1期346-,共1页
关键词 CO comparison of result between the ELISAS/CO values and western blotassay
暂未订购
Comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping, transcranial Doppler sonography and computer tomography examinations
3
作者 Dongruo He Xiaoying Xu +1 位作者 Yinghui Zhang Guochao Han 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期379-381,共3页
BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderat... BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to severe hypoxic-ischemic encephalopathy (HIE). OBJECTIVE: To observe the abnormal results of HIE at different degrees detected with BEAM and TCD in infant patients, and compare the detection results at the same time point between BEAM, TCD and computer tomography (CT) examinations. DESIGN : Contrast observation SETTING: Departments of Neuro-electrophysiology and Pediatrics, Second Affiliated Hospital of Qiqihar Medical College. PARTICIPANTS: Totally 416 infant patients with HIE who received treatment in the Department of Newborn Infants, Second Affiliated Hospital of Qiqihar Medical College during January 2001 and December 2005. The infant patients, 278 male and 138 female, were at embryonic 37 to 42 weeks and weighing 2.0 to 4.1 kg, and they were diagnosed with CT and met the diagnostic criteria of HIE of newborn infants compiled by Department of Neonatology, Pediatric Academy, Chinese Medical Association. According to diagnostic criteria, 130 patients were mild abnormal, 196 moderate abnormal and 90 severe abnormal. The relatives of all the infant patients were informed of the experiment. METHOOS: BEAM and TCD examinations were performed in the involved 416 infant patients with HIE at different degrees with DYD2000 16-channel BEAM instrument and EME-2000 ultrasonograph before preliminary diagnosis treatment (within 1 month after birth) and 1,3,6,12 and 24 months after birth, and detected results were compared between BEAM, TCD and CT examinations. MAIN OUTCOME MEASURES: Comparison of detection results of HIE at different time points in infant patients between BEAM. TCD and CT examinations. RESULTS: All the 416 infant patients with HIE participated in the result analysis. (1) Comparison of the detected results in infant patients with mild HIE at different time points after birth between BEAM, TCD and CT examinations: BEAM examination showed that the recovery was delayed, and the abnormal rate of BEAM examination was significantly higher than that of CT examination 1 and 3 months after birth [55.4%(72/130)vs. 17.0% (22/130 ),x^2=41.66 ;29.2% ( 38/130 ) vs. 6.2% ( 8/130 ), x^2=23.77, P 〈 0.01 ], exceptional patients had mild abnormality and reached the normal level in about 6 months. TCD examination showed that the disease condition significantly improved and infant patients with HIE basically recovered 1 or 2 months after birth, while CT examination showed that infant patients recovered 3 or 4 months after birth. (2) Comparison of detection results of infant patients with moderate HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination 1,3,6 and 12 months after birth [90.8% (178/196),78.6% (154/196),x^2=4.32,P 〈 0.05;64.3% (126/196),43.9% (86/196) ,x^2=16.44 ;44.9% (88/196) ,22.4% (44/196),x^2=22.11 ;21.4% (42/196), 10.2% (20/196),x^2=9.27, P 〈 0.01]. BEAM examination showed that there was still one patient who did not completely recovered in the 24^th month due to the relatives of infant patients did not combine the treatment,. TCD examination showed that the abnormal rate was 23.1%(30/196)in the 1^st month after birth, and all the patients recovered to the normal in the 3^rd month after birth, while CT examination showed that mild abnormality still existed in the 24^th month after birth (1.0% ,2/196). (3) Comparison of detection results of infant patients with severe HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination in the 1^st, 3^rd, 6^th and 12^th months after birth[86.7% (78/90),44.4% (40/90),x^2=35.53;62.2% (56/90),31.1% (28/90),x^2=17.51 ;37.8% (34/90),6.7% (6/90), x^2=27.14, P 〈 0.01]. BEAM examination showed that mild abnormality still existed in 4 infant patients in the 24^th month after birth. TCD examination showed that the abnormal rate was 11.1% (10/90) in the 3^rd month after birth, and all the infant patients recovered in the 6^th month after birth. CT examination showed that the abnormal rate was 6.7%(6/90) in the 12^th month after birth, and all of infant patients recovered to the normal in the 24^th month after birth.CONCLUSION : BEAM is the direct index to detect brain function of infant patients with HIE, and positive reaction is still very sensitive in the tracking detection of convalescent period. The positive rate of morphological reaction in CT examination is superior to that in TCD examination, and the positive rate is very high in the acute period of HIE in examination. 展开更多
关键词 HIE comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping transcranial Doppler sonography and computer tomography examinations
暂未订购
The Results and Comparison of "Logical-Tree" Seismic Zoning in the Panxi Area
4
作者 Zhang Yaoguo,Lei Jiancheng,Tang Rongchang,and Qian Hong Seismological Bureau of Sichuan Province,Chengdu 610041,China 《Earthquake Research in China》 1997年第3期66-74,共9页
On the basis of the technological route of seismic hazard analysis,the methods for determining seismicity parameters,such as b value,annual occurrence rate,and the seismic spatial distribution function,are discussed.T... On the basis of the technological route of seismic hazard analysis,the methods for determining seismicity parameters,such as b value,annual occurrence rate,and the seismic spatial distribution function,are discussed.Then,the seismic intensity zoning in Panxi area in Southwest China is carried out by applying the "logical-tree,"which is made up of multi-parameter schemes.It is clearly shown from the results that seismic intensity zoning is influenced by many uncertain factors and it is necessary to seek a certain balance between seismic safety and investment interest and a good way,with the present limited knowledge level,to obtain seismic intensity zoning is through the "logical-tree" method. 展开更多
关键词 The results and comparison of Seismic Zoning in the Panxi Area Logical-Tree
在线阅读 下载PDF
酒精计标准装置计量比对及结果分析
5
作者 戴力 张晓娟 《计量与测试技术》 2026年第2期48-50,共3页
2024年,贵州省计量测试院作为主导实验室,组织国家酒精计标准装置计量比对(项目编号2024-B-03),采用花瓣式传递方式,针对酒精计修正值进行评定。其中,参比实验室共19家(省级计量技术机构10家,市级计量技术机构3家,企业单位6家),覆盖全... 2024年,贵州省计量测试院作为主导实验室,组织国家酒精计标准装置计量比对(项目编号2024-B-03),采用花瓣式传递方式,针对酒精计修正值进行评定。其中,参比实验室共19家(省级计量技术机构10家,市级计量技术机构3家,企业单位6家),覆盖全国范围内14个省、自治区、直辖市等地区的计量技术机构和企业。本文根据其对比对结果进行分析,并提出建议。 展开更多
关键词 酒精计量值比对 结果满意 结果分析
在线阅读 下载PDF
Comparison of Ruin Probabilities in Compound Poisson Risk Model
6
作者 Dol Nath Khanal 《Open Journal of Statistics》 2019年第1期41-47,共7页
Compound Poisson risk model has been simulated. It has started with exponential claim sizes. The simulations have checked for infinite ruin probabilities. An appropriate time window has been chosen to estimate and com... Compound Poisson risk model has been simulated. It has started with exponential claim sizes. The simulations have checked for infinite ruin probabilities. An appropriate time window has been chosen to estimate and compare ruin probabilities. The infinite ruin probabilities of two-compound Poisson risk process have estimated and compared them with standard theoretical results. 展开更多
关键词 COMPOUND POISSON RISK Model RUIN Probabilities comparison Simulations THEORETICAL results
在线阅读 下载PDF
药物安全性评价毒性病理形态学检查能力验证研究
7
作者 李珊珊 张頔 +4 位作者 李双星 霍桂桃 杨艳伟 项新华 屈哲 《中国药事》 2025年第11期1257-1264,共8页
目的:通过评价参与能力验证实验室的诊断能力,提升药物毒性病理学评价质量。方法:根据中国合格评定国家认可委员会相关文件要求,制备能力验证样品并发放,参照每例案例样品的指定值及评分标准,对参加实验室案例样品的组织病理学诊断、诊... 目的:通过评价参与能力验证实验室的诊断能力,提升药物毒性病理学评价质量。方法:根据中国合格评定国家认可委员会相关文件要求,制备能力验证样品并发放,参照每例案例样品的指定值及评分标准,对参加实验室案例样品的组织病理学诊断、诊断要点描述、相关病理机制和其他病变描述4个方面的阐述,给予相应得分,总分100分。结果:本次能力验证共有92个实验室参与并提交了诊断报告。79个实验室结果被评定为“满意”,13个实验室结果为“不满意”。结论:参加药物非临床安全性评价毒性病理形态学检查能力验证的实验室的诊断能力整体良好,不满意的实验室需查明原因并进行整改,以提升其诊断能力。 展开更多
关键词 毒性病理 形态学检查 能力验证 实验室比对 评价结果
暂未订购
参加全国放射性核素γ能谱分析能力比对结果分析
8
作者 施扬海 陈永雍 +3 位作者 时宇花 卢远盛 何德智 王萍 《中国辐射卫生》 2025年第1期55-60,共6页
目的 通过对2018-2023年全国放射性核素γ能谱分析能力比对结果分析,验证γ能谱分析结果的准确性。方法 统计多年参加全国放射性核素γ能谱分析能力比对结果,对土壤中放射性核素比活度的测量及结果进行分析,为土壤中放射性核素分析能力... 目的 通过对2018-2023年全国放射性核素γ能谱分析能力比对结果分析,验证γ能谱分析结果的准确性。方法 统计多年参加全国放射性核素γ能谱分析能力比对结果,对土壤中放射性核素比活度的测量及结果进行分析,为土壤中放射性核素分析能力的提高提供技术支撑。结果 2018-2023年6次参加γ能谱分析能力比对,共分析核素23次,测量结果的相对偏差范围为-12.20%~8.11%,|Z_(检验)|范围为0~0.61,U检验范围为0~0.62,U_(rel)范围为0.07~0.12,比对结果总体合格率100%,优秀率33.3%,其中23次放射性核素分析中实验分满分次数达21次,比率达91.3%,但由于多次疏忽和检测报告编制中的不严谨导致扣分,未能进入评优程序,优秀率偏低。结论 比对结果表明,本实验室放射性核素分析测量结果均合格,实验分多次达到满分,表明土壤中γ能谱核素分析系统可靠稳定。 展开更多
关键词 放射性核素 γ能谱分析 能力比对 结果分析
原文传递
阿湖水库除险加固设计方案比选与决策 被引量:1
9
作者 白阳 《红水河》 2025年第2期38-42,48,共6页
笔者对阿湖水库除险加固问题进行深入研究。通过分析水库存在的主要问题,提出三种除险加固设计方案,并从地质条件、调洪成果、工程布置、施工条件、工程量及投资等多个角度对这些方案进行详细比较分析。结果表明:方案一存在坝顶及防浪... 笔者对阿湖水库除险加固问题进行深入研究。通过分析水库存在的主要问题,提出三种除险加固设计方案,并从地质条件、调洪成果、工程布置、施工条件、工程量及投资等多个角度对这些方案进行详细比较分析。结果表明:方案一存在坝顶及防浪墙高程不足等问题;方案二通过增加溢洪道宽度来增强泄流能力,但投资较大;方案三在调洪能力、工程布置和施工条件等方面表现出较好的平衡,不过因石方开挖量较大导致投资成本有所增加,但综合考量各项因素后,优势依然明显。基于上述分析,推荐方案三作为最优方案,以期为后续的水库除险加固提供科学依据。 展开更多
关键词 阿湖水库 除险加固 方案比选 调洪成果 工程布置与施工 工程量与投资
在线阅读 下载PDF
ExC810全自动凝血分析仪检测APTT、PT、TT及FIB性能验证及与ACL-TOP700比对分析 被引量:2
10
作者 邓婷婷 庄丽颖 刘爱胜 《生物医学工程与临床》 2025年第1期110-114,共5页
目的对Ex C810全自动凝血分析仪(简称ExC810)各项性能进行验证,并与ACL-TOP700全自动凝血分析仪(简称ACL-TOP700)进行比对,评价Ex C810各项性能是否满足临床质量要求。方法参照中国凝血仪医药行业标准YY/T0659—2017、WS/T 406—2012及... 目的对Ex C810全自动凝血分析仪(简称ExC810)各项性能进行验证,并与ACL-TOP700全自动凝血分析仪(简称ACL-TOP700)进行比对,评价Ex C810各项性能是否满足临床质量要求。方法参照中国凝血仪医药行业标准YY/T0659—2017、WS/T 406—2012及美国临床和实验室标准协会(CLSI)制定的性能验证相关评价方案和标准,对Ex C810检测活化部分凝血活酶时间(APTT)、凝血酶原时间(PT)、凝血酶时间(TT)、纤维蛋白原(FIB)及D-二聚体(DD)的精密度、准确度、携带污染率(CPR)及线性进行评价,并将ExC810检测结果与用于室间质评的TOP700进行比对。结果ExC810检测正常值样本APTT、PT、TT、FIB及DD的批内变异系数(CV)分别为1.00%、0.90%、0.80%、2.02%及2.55%,异常值样本分别为1.59%、1.17%、1.99%、1.65%及3.07%;ExC810检测APTT、PT、TT、FIB及DD准确度的相对偏倚(Bias)分别为1.38%、1.73%、0.70%、-1.08%和2.83%;ExC810检测APTT、PT、TT、FIB及DD的线性分别为0.9826、0.9901、0.9927、0.9990、0.9929,均大于厂家要求>0.98;ExC810检测APTT、PT、TT、FIB及DD的CPR分别为-0.09%、-1.85%、0.36%、0.00%、2.27%,表明该仪器检测上述指标污染率很低;ExC810检测APTT和PT的结果与ACL-TOP700基本一致,差异无统计学意义(P>0.05);而TT和FIB的结果明显高于ACL-TOP700,DD结果明显低于ACL-TOP700,差异有统计学意义(P<0.05);ExC810检测APTT、PT、TT及FIB的结果与ACL-TOP700具有良好的相关性,相关系数(r)分别为0.9135、0.9770、0.9601、0.8854,而DD结果相关性差(r=0.4602)。结论ExC810分析仪具有良好的重复性、准确度、线性及携带污染率低,且与ACL-TOP700具有良好的相关性,可满足临床质量要求。但两台仪器检测的TT和FIB结果存在明显差异,需进行校正,确保不同仪器结果的一致性。 展开更多
关键词 Ex C810分析仪 ACL-TOP700分析仪 凝血功能 性能验证 结果比对 相关性
原文传递
水泥胶砂强度试件两种成型试验方法的对比分析
11
作者 余莉莉 赵汝英 +1 位作者 雷家辉 龙清源 《广州建筑》 2025年第4期64-69,共6页
胶砂强度作为评定水泥产品质量的核心指标,其检测结果的准确性直接影响建筑工程质量与材料选型。现行国家标准《通用硅酸盐水泥》(GB 175-2023)推荐振实台法(基准法)和振动台法(代用法)两种成型方法,但两种方法在操作流程与振实机理上... 胶砂强度作为评定水泥产品质量的核心指标,其检测结果的准确性直接影响建筑工程质量与材料选型。现行国家标准《通用硅酸盐水泥》(GB 175-2023)推荐振实台法(基准法)和振动台法(代用法)两种成型方法,但两种方法在操作流程与振实机理上的显著差异可能导致检测结果偏差,给试件成型方法选择带来困惑。本研究选取P.Ⅱ52.5、P.Ⅱ52.5R、P.O 42.5和P.Ⅰ42.5四类典型水泥样品,通过控制试验环境(温度(20±2)℃,湿度50%~60%)、统一检测设备与操作人员等变量,系统开展一系列对比试验。采用密度测定、气孔观测、抗压/抗折强度测试等方法,从成型效率、试件密实度、强度发展规律等维度进行量化分析。试验结果表明:振动台法通过高频低幅振动(3000次/分钟,0.76mm)形成的试件密实度较振实台法提升1.0%~2.5%,气孔数量减少约40%,3d和28d抗折强度分别提高7%~13%和5%~10%,3 d和28 d抗压强度分别增长5%~10%和4%~12%。研究证实振动台法通过优化振实能量传递效率(能耗提升10倍至30000 J),显著改善试件均匀性。建议检测实验室优先选用振动台法成型试件,该方法不仅简化了操作流程(步骤减少62.5%),还能提升检测效率30%以上,为水泥质量精准评价提供技术保障。 展开更多
关键词 胶砂试件 强度 振实台 振动台 比较结果
在线阅读 下载PDF
液体恒温试验设备实验室间计量比对和结果分析
12
作者 沈健 周逸 +3 位作者 吕茂超 刘银锋 刘秀丽 潘永杲 《计量与测试技术》 2025年第5期50-53,共4页
为了验证液体恒温试验设备计量校准能力,无锡市检验检测认证研究院组织江苏省5个地市级法定计量机构根据JJF 2019-2022《液体恒温试验设备温度性能测试规范》,对温度偏差、均匀度和波动度进行计量比对,并对结果进行分析,从而为各参与单... 为了验证液体恒温试验设备计量校准能力,无锡市检验检测认证研究院组织江苏省5个地市级法定计量机构根据JJF 2019-2022《液体恒温试验设备温度性能测试规范》,对温度偏差、均匀度和波动度进行计量比对,并对结果进行分析,从而为各参与单位申请建立计量标准提供能力验证的依据。 展开更多
关键词 液体恒温试验设备 计量比对 结果分析
在线阅读 下载PDF
纺织品拒油性能测试的实验室间比对及影响因素分析
13
作者 陆燕瑜 张婷 +1 位作者 许芸 祝佳琼 《纺织科学研究》 2025年第5期53-55,共3页
通过对纺织品拒油性能在11家实验室间比对结果的分析研究,旨在查找影响纺织品拒油性能测试的关键因素,为纺织品拒油性能测试、统一测试结果提供参考。本次在11家实验室间对5个典型样品按照GB/T 19977—2014《纺织品拒油性抗碳氢化合物... 通过对纺织品拒油性能在11家实验室间比对结果的分析研究,旨在查找影响纺织品拒油性能测试的关键因素,为纺织品拒油性能测试、统一测试结果提供参考。本次在11家实验室间对5个典型样品按照GB/T 19977—2014《纺织品拒油性抗碳氢化合物试验》进行比对试验。试验结果表明,1#样品有3家实验室的测试结果偏差-1.0级;2#样品有1家实验室的测试结果偏差+1.0级,有2家实验室的测试结果偏差-1.5级,有1家实验室的结果偏差+4.0级;3#样品有1家实验室的测试结果偏差+1.0级,有3家实验室的测试结果偏差-1.5级;4#样品有1家实验室的测试结果偏差-1.5级,有1家实验室的测试结果偏差+3.5级;5#样品有2家实验室的测试结果偏差+1.0级;以上偏差均超过指定值±0.5级的偏差范围。结果表明,实验室间纺织品拒油性能的比对结果存在差异。产生差异的原因主要有两个方面,一是人员目光差异,对试样湿润现象判断以及湿润终点判定不同导致结果不同;二是试剂差异,试剂的表面张力不同导致结果不同。 展开更多
关键词 拒油性能 实验室间比对 结果差异
在线阅读 下载PDF
加筋材料对边坡稳定性的影响研究
14
作者 李怡文 汤伟 +3 位作者 杨雁波 何云松 符小俊 徐杜彬 《建筑技术》 2025年第4期493-499,共7页
依托云南省富源县万里扬场地高填方边坡工程,利用有限元软件midas GTS NX建立相应的三维加筋边坡模型,分别对加筋间距、长度、模量、位置4个加筋土治理方案内部因素对边坡的影响进行研究,将数值模拟结果与实际监测数据进行对比分析,验... 依托云南省富源县万里扬场地高填方边坡工程,利用有限元软件midas GTS NX建立相应的三维加筋边坡模型,分别对加筋间距、长度、模量、位置4个加筋土治理方案内部因素对边坡的影响进行研究,将数值模拟结果与实际监测数据进行对比分析,验证模型的可靠性,并对加筋土技术在边坡支护治理工程的作用机理进行深入探索。 展开更多
关键词 加筋土 高边坡 数值分析 结果对比
在线阅读 下载PDF
三款测氡仪在环境氡浓度监测中的对比分析
15
作者 张套 彭文斌 +3 位作者 常青 林晨 于慧君 黎润华 《绿色科技》 2025年第10期176-180,共5页
了解常用测氡仪的工作原理和结构,比对同一环境下测氡仪的监测结果,为环境氡浓度监测及仪器选择提供参考,并对检定间隔期内仪器维护和使用提供建议。选择常用的AlphaGUARD系列P2000 Pro型测氡仪、RAD7型测氡仪及NRM-P01型测氡仪各1台在... 了解常用测氡仪的工作原理和结构,比对同一环境下测氡仪的监测结果,为环境氡浓度监测及仪器选择提供参考,并对检定间隔期内仪器维护和使用提供建议。选择常用的AlphaGUARD系列P2000 Pro型测氡仪、RAD7型测氡仪及NRM-P01型测氡仪各1台在同一场所进行环境氡浓度测量,结合仪器基本原理和结构,对测量结果进行分析比较,并提出差异产生的原因。结果表明:三台测氡仪前2 h测值的波动较大,舍去前2 h测量数据后3台仪器测值均值无显著性差异。指出氡浓度测量应根据不同环境状况及目的选择合适的仪器,在仪器保存和使用过程中应采取适当措施以保证仪器性能。 展开更多
关键词 测氡仪 氡浓度测量 结果比对
在线阅读 下载PDF
实验室间比对的实施方法研究
16
作者 安禹承 唐启旺 关广东 《电子质量》 2025年第11期66-69,共4页
在质量管理中,为了确保实验室保持高水平的校准和检测能力,可以通过参与能力验证、实验室间比对或测量审核等活动,评估测量数据的可靠性和有效性。对实验室间比对实施方法进行了研究,收集参比者的测量数据及其扩展不确定度和参考值及参... 在质量管理中,为了确保实验室保持高水平的校准和检测能力,可以通过参与能力验证、实验室间比对或测量审核等活动,评估测量数据的可靠性和有效性。对实验室间比对实施方法进行了研究,收集参比者的测量数据及其扩展不确定度和参考值及参考值的扩展不确定度,计算出归一化偏差E_n值,用E_n值可以反映出实验室的检测/校准能力。实验室间比对能够客观反映实验室整体检测/校准水平、确保检测/校准结果的准确性和可靠性,为发现和改进检测体系中存在的问题提供有效依据,对提升客户信任度具有重要价值。 展开更多
关键词 结果有效性 实验室间比对 能力验证 测量审核
在线阅读 下载PDF
验光仪顶焦度量值比对及结果分析
17
作者 黄霞 《仪器仪表标准化与计量》 2025年第1期46-48,共3页
验光仪是广泛应用于各医院眼科、眼镜验配企业及计量技术机构检测工作中常用的计量仪器,其计量性能准确与否是评价眼镜是否合格的依据,并直接关系到广大眼镜消费者的身心健康。为客观、公正、科学地反映上海市各郊区计量技术机构验光仪... 验光仪是广泛应用于各医院眼科、眼镜验配企业及计量技术机构检测工作中常用的计量仪器,其计量性能准确与否是评价眼镜是否合格的依据,并直接关系到广大眼镜消费者的身心健康。为客观、公正、科学地反映上海市各郊区计量技术机构验光仪顶焦度量值传递工作的技术现状,了解各实验室检测方法、人员水平、数据处理能力,加强对计量标准的管理,确保本市郊区范围内验光仪顶焦度量值的准确和一致,保证国家量值传递的准确可靠,本文通过比对的方式检验和评定各参比实验室对验光仪顶焦度量值的检定能力。 展开更多
关键词 计量比对 稳定性 不确定度分析 参考值 结果评价En值
在线阅读 下载PDF
卡尔曼滤波相位解缠及其与其他方法的对比分析 被引量:17
18
作者 刘国林 郝华东 陶秋香 《武汉大学学报(信息科学版)》 EI CSCD 北大核心 2010年第10期1174-1178,共5页
一般相位解缠算法通常在相位解缠前首先需要借助滤波算法进行噪声消除,随后才能相位解缠,以保证解缠的质量和顺利实施。卡尔曼滤波将相位解缠问题转化为状态估计问题,实现相位解缠与噪声消除一并处理,简化了数据处理过程。利用真实干涉... 一般相位解缠算法通常在相位解缠前首先需要借助滤波算法进行噪声消除,随后才能相位解缠,以保证解缠的质量和顺利实施。卡尔曼滤波将相位解缠问题转化为状态估计问题,实现相位解缠与噪声消除一并处理,简化了数据处理过程。利用真实干涉SAR数据进行实验,采用卡尔曼滤波相位解缠算法进行处理,并与其他几种较常用相位解缠算法的结果从目视和定量两方面进行比较和分析。验证了卡尔曼滤波相位解缠方法在滤波和解缠效果方面的有效性和可行性,可以获得较为可靠的解缠结果。 展开更多
关键词 INSAR 相位解缠 卡尔曼滤波 算法比较 结果分析
原文传递
石油地质气相色谱及气相色谱-质谱实验室比对结果评价 被引量:6
19
作者 魏彩云 马行陟 +5 位作者 胡国艺 许怀先 柳少波 魏金红 翁娜 吕玥 《石油实验地质》 CAS CSCD 北大核心 2023年第3期528-536,共9页
为了解全国石油地质行业气相色谱及气相色谱-质谱实验室间的检测能力,提高检测水平,促进行业间交流,由石油地质勘探专业标准化委员会牵头,组织全国石油地质相关实验室开展了比对工作。气相色谱及气相色谱—质谱分析测试比对共有全国23... 为了解全国石油地质行业气相色谱及气相色谱-质谱实验室间的检测能力,提高检测水平,促进行业间交流,由石油地质勘探专业标准化委员会牵头,组织全国石油地质相关实验室开展了比对工作。气相色谱及气相色谱—质谱分析测试比对共有全国23家实验室参与,选取全油、饱和烃和芳烃3类样品,根据相关标准规定了统一的实验方法,利用四分位数稳健统计方法评价了各实验室数据质量。结果表明,各实验室数据稳定、可信,分析结果的重复性和再现性良好。气相色谱全油轻烃比对参数合格率为95%,饱和烃和芳烃参数合格率均为97%;气相色谱—质谱比对饱和烃参数合格率100%,芳烃参数合格率为95%,总体满意率较高。部分实验室相关参数出现问题数据及离群值主要原因与样品储存条件、保存时间、仪器型号、测试方法以及人员操作误差等相关,建议各实验室加强质量管控措施,进一步提升实验室气相色谱及气相色谱—质谱检测能力水平。 展开更多
关键词 色谱—质谱 色谱 全油 饱和烃 芳烃 比对结果
在线阅读 下载PDF
理化实验室室间比对结果与分析 被引量:5
20
作者 周伟斌 高新芬 +1 位作者 顾建忠 王怡 《中国预防医学杂志》 CAS 2009年第7期615-619,共5页
目的通过参加实验室间比对活动,提高实验室的检测技能,总结发现实验室存在的问题。方法对实验室参加能力验证活动中的12个项目的检测结果和浙江省质量合格评定协会等对相关项目的能力验证报告中的相关统计结果进行分析及实验资料的回顾... 目的通过参加实验室间比对活动,提高实验室的检测技能,总结发现实验室存在的问题。方法对实验室参加能力验证活动中的12个项目的检测结果和浙江省质量合格评定协会等对相关项目的能力验证报告中的相关统计结果进行分析及实验资料的回顾检查。结果参加比对的10个项目结果分别为满意和优秀,有2个项目结果有问题。并在标准运用上有使用过期标准方法、标准滴定溶液配制不规范和记录报告有误等情况。结论实验室比对结果总体是比较满意的,但部分项目已经存在结果偏离的趋向,应引起足够的重视,质量管理工作仍然需要加强。 展开更多
关键词 室间比对 结果 评价 稳健统计
原文传递
上一页 1 2 18 下一页 到第
使用帮助 返回顶部