期刊文献+
共找到2,020篇文章
< 1 2 101 >
每页显示 20 50 100
A Low Common-Mode Voltage Virtual Space Vector Modulation of Three-Level Converters for Doubly-Fed Variable-Speed Pumped Storage Systems
1
作者 Ziqiang Man Lei Zhao +6 位作者 Zheng Tao Shiming Cheng Wei Yan Gaoyue Zhong Yu Lu Wenming Zhang Li Zhang 《Energy Engineering》 2025年第9期3555-3572,共18页
With the rapid integration of renewable energy sources,modern power systems are increasingly challenged by heightened volatility and uncertainty.Doubly-fed variable-speed pumped storage units(DFVS-PSUs)have emerged as... With the rapid integration of renewable energy sources,modern power systems are increasingly challenged by heightened volatility and uncertainty.Doubly-fed variable-speed pumped storage units(DFVS-PSUs)have emerged as promising technologies for mitigating grid oscillations and enhancing system flexibility.However,the excitation converters in DFVS-PSUs are prone to significant issues such as elevated common-mode voltage(CMV)and neutral-point voltage(NPV)fluctuations,which can lead to electromagnetic interference and degrade transient performance.To address these challenges,an optimized virtual space vector pulse width modulation(OVSVPWM)strategy is proposed,aiming to suppress CMV and NPV simultaneously through coordinated multi-objective control.Specifically,a dynamic feedback mechanism is introduced to adjust the balancing factor of basic vectors in the synthesized virtual small vector in real-time,achieving autonomous balancing of the NPV.To address the excessive switching actions introduced by the OVSVPWM strategy,a phase duty ratio-based sequence reconstruction method is adopted,which reduces the total number of switching actions to half of the original.A zero-level buffering scheme is employed to reconstruct the single-phase voltage-level output sequence,achieving peak CMV suppression down to udc/6.Simulation results demonstrate that the proposed strategy significantly improves electromagnetic compatibility and operational stability while maintaining high power quality. 展开更多
关键词 Doubly-fed variable-speed pumped storage units three-level excitation converter common-mode voltage neutral-point voltage virtual space voltage vector
在线阅读 下载PDF
A Hybrid Five-Level Single-Phase Rectifier with Low Common-Mode Voltage 被引量:1
2
作者 TIAN Ruihan WU Xuezhi +2 位作者 XU Wenzheng ZUO Zhiling CHEN Changqing 《ZTE Communications》 2023年第4期78-84,共7页
Rectifiers with high efficiency and high power density are crucial to the stable and efficient power supply of 5G communication base stations,which deserves in-depth investigation.In general,there are two key problems... Rectifiers with high efficiency and high power density are crucial to the stable and efficient power supply of 5G communication base stations,which deserves in-depth investigation.In general,there are two key problems to be addressed:supporting both alternating current(AC)and direct current(DC)input,and minimizing the common-mode voltage as well as leakage current for safety reasons.In this paper,a hybrid five-level single-phase rectifier is proposed.A five-level topology is adopted in the upper arm,and a half-bridge diode topology is adopted in the lower arm.A dual closed-loop control strategy and a flying capacitor voltage regulation method are designed accordingly so that the compatibility of both AC and DC input is realized with low common voltage and small passive devices.Simulation and experimental results demonstrate the effectiveness and performance of the proposed rectifier. 展开更多
关键词 multilevel rectifier 5L-ANPC low common-mode voltage AC-DC hybrid input
在线阅读 下载PDF
THE DESIGN OF BALANCED AMPLIFIER BASED ON COMMON-MODE FEEDBACK
3
作者 董炜 刘阳 +1 位作者 姜黎 李联 《Journal of Electronics(China)》 1995年第4期298-303,共6页
The balanced operational amplifier including its merits and designing methods is discussed by comparing its performance to a conventional differential output amplifier when used in a single balanced stage. A balanced ... The balanced operational amplifier including its merits and designing methods is discussed by comparing its performance to a conventional differential output amplifier when used in a single balanced stage. A balanced OTA circuit design is also presented. 展开更多
关键词 OPERATIONAL AMPLIFIER Balanced-output STRUCTURE common-mode FEEDBACK
在线阅读 下载PDF
Double-ring high-frequency common-mode switching oscillation current sensor for inverter-fed machine winding insulation monitoring
4
作者 Lingqing Pan Xizhou Du +3 位作者 Xing Lei Ting Ye Dawei Xiang Hao Li 《Global Energy Interconnection》 EI CSCD 2024年第1期106-116,共11页
Insulation failure significantly contributes to the unpredictable shutdown of power equipment.Compared to the partial discharge and high-frequency(HF)injection methods,the HF common-mode(CM)leakage current method offe... Insulation failure significantly contributes to the unpredictable shutdown of power equipment.Compared to the partial discharge and high-frequency(HF)injection methods,the HF common-mode(CM)leakage current method offers a non-intrusive and highly sensitive alternative.However,the detection of HF CM currents is susceptible to interference from differential-mode(DM)currents,which exhibit high-amplitude and multifrequency components during normal operation.To address this challenge,this paper proposes a double-ring current sensor based on the principle of magnetic shielding for inverter-fed machine winding insulation monitoring.The inner ring harnesses the magnetic aggregation effect to isolate the DM current magnetic field,whereas the outer ring serves as the magnetic core of the Rogowski current sensor,enabling HF CM current monitoring.First,the magnetic field distributions of the CM and DM currents were analyzed.Then,a correlation between the sensor parameters and signal-to-noise ratio of the target HF CM current was established.Finally,an experimental study was conducted on a 3-kW PMSM for verification.The results indicate that the proposed double-ring HF CM sensor can effectively mitigate DM current interference.Compared to a single-ring sensor,a reduction of approximately 40%in the DM component was achieved,which significantly enhanced the precision of online insulation monitoring. 展开更多
关键词 Magnetic shielding Double-ring common-mode current Maxwell simulation
在线阅读 下载PDF
Hybrid Common-mode EMI Filter Design for Electric Vehicle Traction Inverters 被引量:3
5
作者 Yongjie Han Zhihong Wu Deliang Wu 《Chinese Journal of Electrical Engineering》 CSCD 2022年第4期52-60,共9页
A feedforward current-sense current-compensation(CSCC)active EMI filter(AEF)for the direct current-side common-mode(CM)electromagnetic interference(EMI)suppression of high-power electric vehicle traction inverters is ... A feedforward current-sense current-compensation(CSCC)active EMI filter(AEF)for the direct current-side common-mode(CM)electromagnetic interference(EMI)suppression of high-power electric vehicle traction inverters is analyzed and designed.A detailed design of the components with formulas is provided based on an analysis of the CSCC AEF,including the CSCC AEF topology and its implementation.The feedforward active filter stage was implemented using a simple current transformer and a small circuit board.Only a small passive filter with a high resonant frequency is required for high-frequency noise attenuation.The filter’s effectiveness was validated using the simulation results and experimental measurements. 展开更多
关键词 Active EMI filter hybrid EMI filter common-mode EMI traction inverter
原文传递
Influence of motor cable on common-mode currents in an inverter-fed motor drive system 被引量:2
6
作者 Peng-kang XIE Jia-zheng LU +1 位作者 Guo-zhu CHEN Heng-lin CHEN 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2018年第2期273-284,共12页
Induction motor drive systems fed by cables are widely used in industrial applications. However, high-frequency switching of power devices will cause common-mode(CM) voltages during operation, leading to serious CM ... Induction motor drive systems fed by cables are widely used in industrial applications. However, high-frequency switching of power devices will cause common-mode(CM) voltages during operation, leading to serious CM currents in the motor drive systems. CM currents through the cables and motors in the drive systems can cause electromagnetic interference(EMI) with the surrounding electronic equipment and shorten the life of induction motors. Therefore, it is necessary to analyze the CM currents in motor drive systems. In this paper, high-frequency models of unshielded and shielded power cables are formulated. The frequency-dependent effects and mutual inductances of the cables are taken into account. The power cable parameters are extracted by the finite element method and validated by measurements. High-frequency models of induction motors and inverters are introduced from existing works. The CM currents at the motor and inverter terminals are obtained, and the influence of the cable length and cable type on the CM currents is analyzed. There is a good agreement between the experimental results and the CM currents predicted by the proposed models. 展开更多
关键词 common-mode currents Cable model Motor drive system Parameter extraction
原文传递
Dual-current-injection CSCC Active Common-mode EMI Filters with High Insertion Loss for DC-DC Converters 被引量:2
7
作者 Hong Li Siyi Wang +1 位作者 Chongmo Zhang Bo Zhang 《Chinese Journal of Electrical Engineering》 CSCD 2022年第4期19-29,共11页
With the increase in the switching frequency and power density,DC-DC converters encounter more severe electromagnetic interference(EMI)problems.To suppress the common-mode EMI generated by converters,as well as mainta... With the increase in the switching frequency and power density,DC-DC converters encounter more severe electromagnetic interference(EMI)problems.To suppress the common-mode EMI generated by converters,as well as maintain the high-power-density of converters,the active EMI filter(AEF)has attracted increasing interest owing to its small volume.The EMI suppression effect of the common single-stage single-sense single-injection AEF is confined because of the limited insertion loss,and the volume of the multi-stage AEF will be bulky.To solve this problem,this paper proposes a compact dual-current-injection current-sense current-compensation(DCJ-CSCC)AEF to increase the insertion loss in the entire conducted EMI frequency band,as well as considering the volume of the AEF.The structure and operating principle of the proposed AEF are introduced.Finally,taking a boost converter as an example,the effectiveness and advantages of the proposed DCJ-CSCC AEF were verified through a simulation and experiment,the results show that the proposed AEF has a better EMI suppression effect on the entire conducted EMI frequency band with a similar volume compared with existing single-injection feedforward current-sense current-compensation(FF-CSCC)and feedback current-sense current-compensation(FB-CSCC)AEFs.This paper provides a new selection for EMI suppression in DC-DC converters. 展开更多
关键词 Electromagnetic interference active EMI filter common-mode electromagnetic compatibility
原文传递
Design of a wideband common-mode filter using approximate closed-loop pattern of compact C-shaped defected ground structure 被引量:1
8
作者 Yao Yindi Zeng Zhibin 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2017年第3期70-74,共5页
A compact common-mode filter is proposed to suppress common-mode noise for application of high-speed differential signal traces. The filter adopts one big C-shaped defected ground structure (DGS) cell in the left of... A compact common-mode filter is proposed to suppress common-mode noise for application of high-speed differential signal traces. The filter adopts one big C-shaped defected ground structure (DGS) cell in the left of ground plane and two small C-shaped DGS cells with opposite direction in the right of ground plane. Because these DGS cells have different dimensions, the filter has three adjacent equivalent resonant points, which can suppress wideband common-mode noise effectively. The left C-shaped DGS and its adjacent C-shaped DGS cell form an approximate closed structure, which can efficiently reduce the influence of the mutual capacitance. The filter provides a common-mode suppression from 3.6 GHz to 14.4 GHz over 15 dB while it has a small size of 10 minx 10 mm. The fractional bandwidth of the filter is 120%, and the differential signals still keep good signal integrity. The experimental results are in good agreement with the simulated results. 展开更多
关键词 common-mode filter approximate closed-loop structure defected ground structure insertion loss
原文传递
An Accurate Common-Mode Current Prediction Method for Transformerless Photovoltaic Inverters Based on Graph Theory 被引量:1
9
作者 Yangbin Zeng Hong Li +2 位作者 Bo Zhang Zhichang Yang Trillion Q.Zheng 《Chinese Journal of Electrical Engineering》 CSCD 2017年第3期59-67,共9页
The common-mode current is an important indicator with transformerless photovoltaic inverters.However,up to now,there is not an accurate method to predict common-mode current in the inverter design process,resulting f... The common-mode current is an important indicator with transformerless photovoltaic inverters.However,up to now,there is not an accurate method to predict common-mode current in the inverter design process,resulting from inappropriate device selection or exceeded the expected common-mode current.In order to solve this problem,this paper proposes an accurate common-mode current prediction method based on graph theory for transformerless photovoltaic inverters.In this paper,the mathematic model of the common-mode current is derived using graph theory analysis method in the full-bridge topology,and it is used to predict common-mode current.The validity and correctness of the proposed prediction method are validated by simulation and experiment.The oscillation frequency and amplitude can be predicted by the proposed common-mode prediction method,whereas the traditional common-mode analysis method cannot.This paper provides a novel way to predict and analyze common-mode current in the transformerless photovoltaic inverters. 展开更多
关键词 common-mode current transformerless photovoltaic inverters prediction method electromagnetic interference
原文传递
Wideband bandstop defected ground structure filter with enhanced common-mode suppression using split ring
10
作者 Yao Yindi Zeng Zhibin 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2015年第5期80-83,共4页
An effective method to broaden the rejection bandwidth of dump-shaped defected ground structure(DGS) filter design is proposed in the paper. One traditional dumbbell-shaped DGS is split by using one split ring, and re... An effective method to broaden the rejection bandwidth of dump-shaped defected ground structure(DGS) filter design is proposed in the paper. One traditional dumbbell-shaped DGS is split by using one split ring, and reconstructed into two different compact DGSs. The distance between both of the DGSs is so close that there exists mutual inductance, which can be utilized to broaden the rejection bandwidth effectively. The effect of different parameters of the split ring on the rejection bandwidth and depth of the filter is analyzed. Simulated results demonstrate that, with the same area of 5.5mm by 10 mm, rejection bandwidth of the proposed filter is from 4.4 GHz to 10.5 GHz for the common-mode noise(CM) while that of the traditional dumbbell-shaped DGS is from 5.3 GHz to 7.3 GHz. Compared to other schematics adopting multiple DGS to broaden bandwidth, it can broaden the bandwidth by dividing the existed DGS into multiple parts and reconstructing a new filter. The experimental results show good agreement with simulated results. 展开更多
关键词 defected ground structure common-mode filter diffe
原文传递
Common-mode Electromagnetic Interference Mitigation for Solid-state Transformers
11
作者 Dong Jiang Zhenyu Wang +3 位作者 Wenjie Chen Jianrui Liu Xuan Zhao Wei Sun 《Chinese Journal of Electrical Engineering》 CSCD 2022年第3期22-36,共15页
Solid-state transformers(SSTs)have been widely used in many areas owing to their advantages of high-frequency isolation and high power density.However,high-frequency switching causes severe electromagnetic interferenc... Solid-state transformers(SSTs)have been widely used in many areas owing to their advantages of high-frequency isolation and high power density.However,high-frequency switching causes severe electromagnetic interference(EMI)problems.Particularly,the common-mode(CM)EMI caused by the switching of the dual active bridge(DAB)converter is conducted through the parasitic capacitances in the high-frequency transformer and impacts the system reliability.With the understanding of the CM EMI model in SSTs,CM EMI mitigation methods have been studied.For passive mitigation,the coupled inductor can be integrated with the phase-shift inductor function to reduce CM EMI.For active mitigation,variations in the DAB switching frequency can help reduce the CM EMI peak.An active EMI filter can also be designed to sample and compensate for CM EMI.Using these methods,CM EMI can be reduced in SSTs. 展开更多
关键词 Solid-state transformer(SST) Dual active bridge(DAB) common-mode Electromagnetic interference(EMI)
原文传递
Modeling Common-Mode Current Due to Asymmetric Aging of Machine Winding Insulation
12
作者 Jin Zhao Aaron D.Brovont 《Complex System Modeling and Simulation》 2023年第2期118-128,共11页
Machine stator winding insulation degradation is one of the main results of machine aging.It is non-negligible once this degradation process becomes asymmetric between phases.The traditional way to determine the insul... Machine stator winding insulation degradation is one of the main results of machine aging.It is non-negligible once this degradation process becomes asymmetric between phases.The traditional way to determine the insulation state of health is a partial discharge test.However,this method requires the system offline,which causes production loss and extra administrative burden.This paper presents an idea for better characterizing the insulation machine’s state of health using common-mode(CM)behavior in the machine-drive system.With the help of circuit decomposition methods and modeling tools,the CM quantities due to asymmetric aging show a unique characteristic that distinguishes itself from other differential-mode(DM)quantities in the equivalent circuit.It is shown effective to represent the asymmetric aging effect from the detection of system leakage current.This paper provides an analytical method to quantify this characteristic from mathematical approaches,and a proper approximation has been made on the CM equivalent model(CEM)such that the CM behavior is accurately characterized.The proposed method will serve the purpose of predicting machine abnormal behavior using the simple RLC circuit.Researchers can adapt this method to quantify and characterize the machine insulation state of health(SOH). 展开更多
关键词 common-mode equivalent circuit machine decomposition machine stator winding insulation health model approximation
原文传递
Novel Modulation Strategy to Achieve Neutral-point Voltage Balance, Common-mode Voltage, and Switching Loss Reduction for Neutral-point Clamped Three-level Inverters
13
作者 Donghan Liu Jinping Wang +1 位作者 Shengyu Liu Weidong Jiang 《Chinese Journal of Electrical Engineering》 CSCD 2024年第4期106-118,共13页
Carrier-based pulse width modulation (CBPWM) and virtual space vector pulse width modulation (VSVPWM) are briefly reviewed for neutral-point-clamped three-level inverters (NPC TLI). A new modulation strategy referred ... Carrier-based pulse width modulation (CBPWM) and virtual space vector pulse width modulation (VSVPWM) are briefly reviewed for neutral-point-clamped three-level inverters (NPC TLI). A new modulation strategy referred to as N3S_CBPWM is then proposed to simultaneously consider multiple goals, such as the-neutral-point voltage (NPV) balance, switching loss, and common-mode voltage (CMV) reduction. For N3S_CBPWM in each switching cycle, the three-phase switching actions are zero, one, and two. In addition, the constraint conditions of the modulation waves are provided based on the reduction of the CMV. Subsequently, N3S_CBPWM, CBPWM, and VSVPWM are compared in terms of the NPV balance capability, switching loss, and CMV reduction. Finally, the feasibility and superiority of the proposed N3S_CBPWM are verified experimentally. 展开更多
关键词 Three-level inverter common-mode voltage switching loss neutral point voltage balance
原文传递
Common-mode radiation characteristic analysis of connections between cables and metal cases
14
作者 Haifeng SONG Zhiyu CHEN 《Frontiers of Electrical and Electronic Engineering in China》 CSCD 2008年第3期353-357,共5页
In this paper,the common-mode radiation characteristic of the connection between a cable and a conductor is analyzed by the electric field integral function(EFIF)and the method of moment(MoM).The RWG basis function is... In this paper,the common-mode radiation characteristic of the connection between a cable and a conductor is analyzed by the electric field integral function(EFIF)and the method of moment(MoM).The RWG basis function is adopted as the conductor basis function,the pulse basis function as the wire basis function and the juncture employs Costa basis function.A scheme of singular region separation is proposed to overcome the integration singularity of juncture matrix elements.Some new conclusions of the common-mode radiation characteristics with the metal case are obtained by numeration. 展开更多
关键词 method of moment(MoM) common-mode radiation metal case electromagnetic compatibility(EMC)
原文传递
含隔直电容的移相全桥变换器EMI抑制方案研究
15
作者 贾红云 胡威 沈湛 《电子元件与材料》 北大核心 2026年第1期85-94,104,共11页
在移相全桥变换器中,隔直电容虽能抑制变压器偏磁饱和,但其两端的高频电压分量却会加剧传导电磁干扰(EMI)的复杂性,而现有变压器模型难以精确揭示由此产生的共模噪声耦合机制。为解决上述问题,首先基于位移电流守恒原理,构建了一个能够... 在移相全桥变换器中,隔直电容虽能抑制变压器偏磁饱和,但其两端的高频电压分量却会加剧传导电磁干扰(EMI)的复杂性,而现有变压器模型难以精确揭示由此产生的共模噪声耦合机制。为解决上述问题,首先基于位移电流守恒原理,构建了一个能够表征绕组内部位移电流路径与绕组间寄生电容定量关系的变压器两电容等效模型。继而,利用该模型对共模干扰回路进行简化分析,据此提出了三种协同作用的抑制策略:谐振腔对称结构法、平衡电容法、辅助变压器对消法。基于一台1400 W原理样机的实验结果表明,该综合抑制方案在150 kHz~30 MHz频段内,能将共模噪声的谐振尖峰降低约20 dB。实验结果验证了所提变压器两电容模型的正确性,以及基于该模型所设计的EMI综合抑制方案的有效性。 展开更多
关键词 隔直电容 电磁干扰 共模噪声 移相全桥 变压器模型 对消
在线阅读 下载PDF
一种综合性能优化的两电平并联类交错一体化空间矢量调制策略
16
作者 杜燕 梁晶 +2 位作者 蔡志成 杨向真 苏建徽 《电工技术学报》 北大核心 2026年第2期622-634,共13页
交错并联逆变器可抵消输出纹波,改善并网电流总谐波畸变率(THD),但可能导致共模和零序环流增大。针对此问题,该文提出一种双机并联逆变器的类交错一体化空间矢量调制(SISVM)策略,旨在实现系统的共模电压、零序环流、输出电流纹波以及开... 交错并联逆变器可抵消输出纹波,改善并网电流总谐波畸变率(THD),但可能导致共模和零序环流增大。针对此问题,该文提出一种双机并联逆变器的类交错一体化空间矢量调制(SISVM)策略,旨在实现系统的共模电压、零序环流、输出电流纹波以及开关损耗的综合优化。该文建立两电平并联逆变器的等效三电平模型,并以共模、环流、开关次数为约束条件筛选等效三电平矢量,并通过两电平载波移相实现类三电平调制。对比分析SISVM的输出电流纹波和环流特性,说明了与三电平空间矢量调制(TLSVM)相比,该调制策略可进一步减小零序环流和开关损耗。最后,通过DSP+Starsim实验平台验证了该策略在零序环流和开关损耗方面的有效性。 展开更多
关键词 交错并联逆变器 共模电压 零序环流 输出电流纹波 开关损耗 类交错 一体化调制
在线阅读 下载PDF
基于电容电压差值提取的闭环共模电压注入的混合式钳位变换器控制方法
17
作者 潘建宇 郭禹伽 +2 位作者 付孝杰 闫升 肖俊伟 《电工技术学报》 北大核心 2026年第2期635-648,共14页
混合式钳位变换器(HCC)因其具有结构简单、电流谐波低、器件数目少等特点,在中高压变频调速系统中具有良好的应用前景。然而,HCC在低频下存在直流母线电容电压剧烈波动,在高频下存在母线电压利用率不高等问题。该文首先建立基于负载电... 混合式钳位变换器(HCC)因其具有结构简单、电流谐波低、器件数目少等特点,在中高压变频调速系统中具有良好的应用前景。然而,HCC在低频下存在直流母线电容电压剧烈波动,在高频下存在母线电压利用率不高等问题。该文首先建立基于负载电流闭环控制下的HCC数学模型,阐明了母线电容电压波动形成的机制,提出一种基于电容电压差值提取的闭环共模电压注入平衡方法,进而实现低频下工况自适应的电容剧烈波动抑制;其次在高频工况下提出一种三倍频共模电压角度补偿策略,提高直流母线电压利用率并兼顾电容电压平衡能力;最后通过仿真与实验对所提方法进行了验证。结果表明,所提方法比开环共模电压方法在宽频范围内具有更强的电容电压波动抑制效果,且能在0 Hz极端工况下稳定工作;在高频工况注入角度补偿后,直流母线电压利用率提高约14%。 展开更多
关键词 混合式钳位变换器 电容电压平衡 闭环共模电压注入 角度补偿
在线阅读 下载PDF
基于北斗卫星导航系统的KMCORS坐标时间序列分析与三维速度场构建
18
作者 查文倩 陈国平 +2 位作者 李旺 徐东方 魏保峰 《测绘通报》 北大核心 2026年第1期113-121,共9页
随着北斗卫星导航系统(BDS)全球组网的完成,其区域服务性能得到显著提升,为基于BDS的区域连续运行参考站(CORS)大地测量应用提供了重要机遇。本文以昆明市及周边地区31个昆明市卫星定位综合服务系统(KMCORS)基准站2022—2024年的观测数... 随着北斗卫星导航系统(BDS)全球组网的完成,其区域服务性能得到显著提升,为基于BDS的区域连续运行参考站(CORS)大地测量应用提供了重要机遇。本文以昆明市及周边地区31个昆明市卫星定位综合服务系统(KMCORS)基准站2022—2024年的观测数据为基础,采用GAMIT/GLOBK软件进行BDS和GPS双系统的基线解算与坐标平差处理,通过对坐标时间序列分析重构,构建了高精度的三维速度场模型。结果表明:①在北(N)和东(E)方向上,BDS和GPS定位精度相当,但在垂直(U)方向上,BDS略逊于GPS;②根据皮尔逊相关系数值得出,BDS站点间表现出更强的空间相关性特征,主成分分析空间滤波方法能够显著提升BDS和GPS坐标时间序列精度;③共模误差改正后,BDS和GPS速度估值趋于一致,平均速率为14.92 mm/a(N)、32.87 mm/a(E)、8.05 mm/a(U)和15.23 mm/a(N)、32.62 mm/a(E)、4.96 mm/a(U)。研究证明,KMCORS的BDS定位精度与GPS持平,可有效应用于城市坐标框架维护和地壳形变监测等领域。 展开更多
关键词 BDS KMCORS 坐标时间序列 共模误差 三维速度场
原文传递
激光/红外双波段复合光电制导组件共口径光学系统设计
19
作者 唐利孬 聂志强 +1 位作者 任丽 牛霞 《应用光学》 北大核心 2026年第1期10-21,共12页
随着精确制导武器的对抗层次越来越高,具有命中精度高的双模复合制导的优势更加明显。设计了一套激光/红外双波段复合光电制导组件共口径光学系统。共口径光学结构可以压缩系统尺寸,红外成像子系统可以获得目标的高清图像,激光接收光学... 随着精确制导武器的对抗层次越来越高,具有命中精度高的双模复合制导的优势更加明显。设计了一套激光/红外双波段复合光电制导组件共口径光学系统。共口径光学结构可以压缩系统尺寸,红外成像子系统可以获得目标的高清图像,激光接收光学子系统可以对目标反射的激光光斑中心进行高精度定位测量。整个系统入射光通光口径44 mm,红外成像系统F数为1,在空间频率42 lp/mm处,温度20℃以下,0°视场光线的MTF值约为0.46,全视场光线的MTF值约为0.36,RMS半径为4.466μm,全视场畸变约为-0.13%。在工作温度范围-40℃~+70℃内系统MTF变化不大于10%。激光接收光学子系统全接收视场为±4°,线性接收视场为±2°,当激光发射功率大于0.6 mW时,激光接收光学系统的截获距离可大于10 km。光学系统总长度为88 mm,宽度为53 mm,加入机械结构后,系统体积为94 mm×68 mm×50 mm,质量为293克。该系统结构简单、紧凑,装调难度低,适用于光电制导组件小型化发展趋势,具有较高的实用价值。 展开更多
关键词 光学设计 光电制导组件 共口径 红外成像系统 激光接收光学系统 四象限探测器
在线阅读 下载PDF
吸收式共模抑制滤波器设计研究进展
20
作者 赵文生 马祎浩 王翔 《微波学报》 北大核心 2026年第1期18-23,共6页
本文系统综述了吸收式共模抑制滤波器的研究进展。该类滤波器通过将共模噪声能量转化为热能实现有效吸收,在抑制高速数字电路中电磁干扰方面展现出优于传统反射式滤波器的性能。文章重点分析了基于介质损耗材料和贴片电阻的两类主流共... 本文系统综述了吸收式共模抑制滤波器的研究进展。该类滤波器通过将共模噪声能量转化为热能实现有效吸收,在抑制高速数字电路中电磁干扰方面展现出优于传统反射式滤波器的性能。文章重点分析了基于介质损耗材料和贴片电阻的两类主流共模抑制滤波器结构,分别探讨了其工作原理、典型架构以及面临的共性挑战,如性能指标间的矛盾、面积占用较大和带宽受限等问题。针对这些挑战,团队提出了多项创新解决方案:采用“传输空间分离结构”以协同提升介质损耗滤波器的共模吸收与差模传输性能;利用“窄边耦合谐振器”优化多级结构,在改善性能的同时减小布局面积;通过“三明治”匹配组件显著扩展单级结构的吸收带宽并增强设计灵活性。最后,对该类滤波器在先进封装等前沿领域的应用前景进行了展望。 展开更多
关键词 信号完整性 共模噪声抑制 吸收式共模抑制滤波器
原文传递
上一页 1 2 101 下一页 到第
使用帮助 返回顶部