To address the current issues with the conventional slide gate system utilized in the steel teeming process,a unique electromagnetic induction controlled automated steel teeming(EICAST)technology has been developed.Co...To address the current issues with the conventional slide gate system utilized in the steel teeming process,a unique electromagnetic induction controlled automated steel teeming(EICAST)technology has been developed.Cooling means of spiral coil in this technology is directly related to its service life.Firstly,heat transfer processes of air cooling and spray cooling were compared and analyzed.Secondly,the impacts of water temperature,water flow rate and air flow rate were examined in order to maximize the spray cooling effect.To maintain coil temperature at a low value consistently throughout the entire thermal cycle process of the ladle,a combined cooling mode was finally employed.Numerical simulation was applied to examine the coil temperature variation with different cooling systems and characteristics.Before coil operation,spray cooling is said to be more effective.By controlling the water flow rate and air flow rate,the spray cooling effect is enhanced.However,water temperature has little or no impact when using spray cooling.Air cooling during the secondary refining process and spray cooling prior to coil operation are combined to further lower coil temperature.When the direction of the spray cooling is from bottom to top,the coil temperature is lowered below 165℃.A practical induction coil cooling plan was provided for the EICAST technology’s production process.展开更多
The published article titled“MicroRNA-148a Acts as a Tumor Suppressor in Osteosarcoma via Targeting Rho-Associated Coiled-Coil Kinase”has been retracted from Oncology Research,Vol.25,No.8,2017,pp.1231–1243.DOI:10.3...The published article titled“MicroRNA-148a Acts as a Tumor Suppressor in Osteosarcoma via Targeting Rho-Associated Coiled-Coil Kinase”has been retracted from Oncology Research,Vol.25,No.8,2017,pp.1231–1243.DOI:10.3727/096504017X14850134190255 URL:https://www.techscience.com/or/v25n8/56908 Following the publication,concerns have been raised about a number of figures in this article.An unexpected area of similarity was identified in terms of the cellular data,where the results from differently performed experiments were intended to have been shown,although the areas immediately surrounding this area featured comparatively different distributions of cells.In addition,the western blots in this article were presented with atypical,unusually shaped and possibly anomalous protein bands in many cases.展开更多
Coiled tube heat exchangers are widely preferred in shell structures due to their superior heat transfer performance,driven by favorable flow characteristics.This study investigates the effect of modifying coil and sh...Coiled tube heat exchangers are widely preferred in shell structures due to their superior heat transfer performance,driven by favorable flow characteristics.This study investigates the effect of modifying coil and shell configurations on heat transfer efficiency.Two key enhancements were examined:adding fins to the outer coil surface and integrating longitudinal slots within a hollowed shell.These modifications promote turbulence and extend heat transfer duration,thereby improving performance.However,they also introduce challenges,including increased pressure loss andmanufacturing complexity.Numerical simulationswere conducted usingANSYS Fluent 2024R1 under identical boundary conditions.With a fixed cold-side flow rate of 3 L/min,the input temperatures for the hot and cold fluids were 333.15 and 291.65 K,respectively.The hot-side flow rate varied between 2 and 6 L/min.Simulation outcomes were reported for the objectives of the study that included the improvement in heat exchangers’heat transfer enhancement.As it was indicated in the study outcomes,the average heat transfer rate increased by 15.56%,the overall heat transfer coefficient enhanced by about 29.51%,and the convective heat transfer coefficient improved by about 75.96%compared to the conventional shell-and-coil tube heat exchanger model.However,the modified technique resulted in a significant pressure drop.展开更多
Short suspension system has an indispensable effect on vehicle handling and ride,so,optimization of vehicle suspension system is one of the most effective methods,which could considerably enhance the vehicle stability...Short suspension system has an indispensable effect on vehicle handling and ride,so,optimization of vehicle suspension system is one of the most effective methods,which could considerably enhance the vehicle stability and controllability.Motion control,stability maintenance and ride comfort improvement are fundamental issues in design of suspension system of off-road vehicles.In this work,a dependent suspension system mostly used in off-road vehicles is modeled using Trucksim software.Then,geometric parameters of suspension system are optimized using integrated anti-roll bar and coiling spring in a way that ride comfort,handling and stability of vehicle are improved.The simulation results of suspension system and variations of geometric parameters due to road roughness and different steering angles are presented in Trucksim and effects of optimization of suspension system during various driving maneuvers in both optimized and un-optimized conditions are compared.The simulation results indicate that the type of suspension system and geometric parameters have significant effect on vehicle performance.展开更多
When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is...When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system.展开更多
Ambient temperature of induction coil is an important factor to influence the implementation of the electromagnetic induction-controlled automated steel-teeming(EICAST) technology. Meanwhile, it also affects the forma...Ambient temperature of induction coil is an important factor to influence the implementation of the electromagnetic induction-controlled automated steel-teeming(EICAST) technology. Meanwhile, it also affects the formation of Fe–C alloy blocking layer, which determines the length and installation position of induction coil. An experimental platform was designed to imitate actual working conditions in a ladle with the EICAST system. Ambient temperature of induction coil under high-temperature condition was measured to verify the accuracy of numerical result. After containing molten steel for 120 min and steel teeming for 40 min, the ambient temperature on the upper side of induction coil is 791 °C. In addition, the position of blocking layer in a 110 t ladle was measured by sand-collection and steel-pour methods, and the criterion temperatures of blocking layer in numerical simulation process were corrected. When the refining temperature is1600 °C and the containing time of molten steel is 120 min, the thickness of blocking layer is 130 mm, and the distance between the upper surface of blocking layer and the upper surface of nozzle brick is 154 mm. When the criterion temperatures are 919 °C and 428 °C, the numerical results can be used to confirm the position of blocking layer and the installation position of induction coil.展开更多
Research on adaptive deformable mirror technology for voice coil actuators(VCAs)is an important trend in the development of large ground-based telescopes.A voice coil adaptive deformable mirror contains a large number...Research on adaptive deformable mirror technology for voice coil actuators(VCAs)is an important trend in the development of large ground-based telescopes.A voice coil adaptive deformable mirror contains a large number of actuators,and there are problems with structural coupling and large temperature increases in their internal coils.Additionally,parameters of the traditional proportional integral derivative(PID)control cannot be adjusted in real-time to adapt to system changes.These problems can be addressed by introducing fuzzy control methods.A table lookup method is adopted to replace real-time calculations of the regular fuzzy controller during the control process,and a prototype platform has been established to verify the effectiveness and robustness of this process.Experimental tests compare the control performance of traditional and fuzzy proportional integral derivative(Fuzzy-PID)controllers,showing that,in system step response tests,the fuzzy control system reduces rise time by 20.25%,decreases overshoot by 78.24%,and shortens settling time by 67.59%.In disturbance rejection experiments,fuzzy control achieves a 46.09%reduction in the maximum deviation,indicating stronger robustness.The Fuzzy-PID controller,based on table lookup,outperforms the standard controller significantly,showing excellent potential for enhancing the dynamic performance and disturbance rejection capability of the voice coil motor actuator system.展开更多
Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and...Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and maximum wire width of gradient coils is one of the key solutions to minimize the maximum current density so as to reduce the local heating and generate higher magnetic field gradient strength. However, maximum current density is hard to optimize together with field linearity, stored magnetic energy, and power dissipation by the traditional target field method. In this paper, a new multi-objective method is proposed to optimize the maximum current density, field linearity, stored magnetic energy, and power dissipation in MRI gradient coils. The simulation and experimental results show that the minimum wire spacings are improved by 159% and 62% for the transverse and longitudinal gradient coil respectively. The maximum wire width increases from 0.5 mm to 1.5 mm. Maximum gradient field strengths of 157 mT/m and 405 mT/m for transverse and lon- gitudinal coil are achieved, respectively. The experimental results in BT-MRI instrument demonstrate that the MRI images with in-plane resolution of 50 ~tm can be obtained by using the designed coils.展开更多
Integrating engineering software is meaningful but challenging for a system code of a fusion device. This issue is seldom considered by system codes currently. Therefore, to discuss the issue, the Integrated Design Sy...Integrating engineering software is meaningful but challenging for a system code of a fusion device. This issue is seldom considered by system codes currently. Therefore, to discuss the issue, the Integrated Design System of TF Coil (IDS-TFC) has been worked out, which consists of physical calculation, CAD, and Finite Element Analysis (FEA). Furthermore, an Integrated and Automatically Optimized Method (IAOM) has been created to address the integration and interfaces. The method utilizes a geometry parameter to connect each design submodule and achieve automatic optimization. Double-objectives optimization has been realized, confirming it is feasible to integrate and optimize engineering design and physical calculation. Moreover, IDS- TFC can also serve as a useful reference of integrated design processing for subsequent fusion design.展开更多
For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating ...For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.展开更多
The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic f...The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets.展开更多
The quality of the stator winding coil directly affects the performance of the motor.A dual-camera online machine vision detection method to detect whether the coil leads and winding regions were qualified was designe...The quality of the stator winding coil directly affects the performance of the motor.A dual-camera online machine vision detection method to detect whether the coil leads and winding regions were qualified was designed.A vision detection platform was designed to capture individual winding images,and an image processing algorithm was used for image pre-processing,template matching and positioning of the coil lead area to set up a coordinate system.After eliminating image noise by Blob analysis,the improved Canny algorithm was used to detect the location of the coil lead paint stripped region,and the time was reduced by about half compared to the Canny algorithm.The coil winding region was trained with the ShuffleNet V2-YOLOv5s model for the dataset,and the detect file was converted to the Open Neural Network Exchange(ONNX)model for the detection of winding cross features with an average accuracy of 99.0%.The software interface of the detection system was designed to perform qualified discrimination tests on the workpieces,and the detection data were recorded and statistically analyzed.The results showed that the stator winding coil qualified discrimination accuracy reached 96.2%,and the average detection time of a single workpiece was about 300 ms,while YOLOv5s took less than 30 ms.展开更多
There are many problems associated with coiled tubing drilling operations, such as great circulation pressure loss inside pipe, difficulties in weight on bit(WOB) transferring, and high probability of differential sti...There are many problems associated with coiled tubing drilling operations, such as great circulation pressure loss inside pipe, difficulties in weight on bit(WOB) transferring, and high probability of differential sticking. Aiming at these problems, solids-free brine drilling fluid system was developed on the basis of formulation optimization with brine base fluid experiment, which was evaluated and applied to field drilling. Based on the optimization of flow pattern regulator, salt-resisting filtrate reducer, high performance lubricant and bit cleaner, the basic formula of the solids-free brine drilling fluid system was formed: brine +(0.1%-0.2%) Na OH +(0.2%-0.4%) HT-XC +(2.0%-3.0%) YLJ-1 +(0.5%-2.0%) SDNR +(1.0%-2.5%) FT-1 A +(1.0%-5.0%) SD-505 + compound salt density regulator. Lab evaluation showed that the fluid had satisfactory temperature resistance(up to 150 ℃), excellent cuttings tolerance(up to 25%), and strong inhibition(92.7% cuttings recovery); Moreover, its lubrication performance was similar to that of all oil-based drilling fluid. The wellbore could be fairly cleaned at annular up-flow velocity of more than 0.8 m/s if the ratio of yield point to plastic viscosity was kept above 0.5. This fluid system has been applied in the drilling of three coiled tubing sidetracking wells in the Liaohe Oilfield, during which the system was stable and easy to adjust, resulting in excellent cuttings transportation, high ROP, regular hole size, and no down hole accidents. In summary, the solids-free brine drilling fluid system can meet the technical requirements of coiled tubing drilling.展开更多
Embolization of collateral veins is often treated with rigid coils(Gianturco and interlocking detachable coils type).However,when dealing with tortuous and dilated collateral veins,there is a high risk for technical f...Embolization of collateral veins is often treated with rigid coils(Gianturco and interlocking detachable coils type).However,when dealing with tortuous and dilated collateral veins,there is a high risk for technical failure and coil migration due to inflexibility of the coils.To safely and successfully solve this problem,Guglielmi detachable coils(GDC) can be used for embolization.Their flexibility allows for easy navigation in tortuous veins,low risk of unintended coil release or coil migration,and safe deployment.A 12-year-old girl with a single ventricle had severe cyanosis and a low exercise tolerance 5 years after Fontan procedure.The symp-toms were caused by a tortuous and dilated collateral from the left phrenic vein into the left pulmonary vein,forming a right-to-left shunt.The collateral,which had a large diameter and high flow,and therefore a high risk of coil migration,was successfully embolized with 8 GDC.There were no complications such as coil migration or cerebral infarction.Transcatheter embolization increased her systemic oxygen saturation from 81%-84% to 94%-95%,and increased her ability to exercise.The embolization procedure using flexible GDC was low risk compared with other rigid coil embolization techniques when performing embolization of tortuous and dilated collateral veins.展开更多
Based on the method of controlling welding stress with trailing, the electromagnetic force in coil-sheet system was simulated with finite element software ANSYS. The effect of parameters of coil on the electromagnetic...Based on the method of controlling welding stress with trailing, the electromagnetic force in coil-sheet system was simulated with finite element software ANSYS. The effect of parameters of coil on the electromagnetic force density fy was analyzed. The results show that the maximum electromagnetic force density fy, max in sheet appears in the position near the inner radius of single-turn coil. The position is independent of section shape of coil. fy, max for flat coil is larger than that for long coil and the coil with wedge shape section, while section areas of all coils are equal to each other. The effect of turn number of multiple-turn coil on fy is dependent on the loop resistance in circuit. The kind of coil with more turns and larger inductance is commended while there is larger loop resistance in circuit. fy increases in a certain magnitude while a magnetic core is located in coil. However, the magnitude of fy is limited by saturating magnetic flux of the core.展开更多
In the non-conventional media like underwater and underground,the Radio Frequency(RF)communication technique does not perform well due to large antenna size requirement and high path loss.In such media,magnetic induct...In the non-conventional media like underwater and underground,the Radio Frequency(RF)communication technique does not perform well due to large antenna size requirement and high path loss.In such media,magnetic induction(MI)communication technique is very promising due to small coil size and constant channel behavior.Unlike the RF technique,the communication range in MI technique is relatively less.To enhance this range,a waveguide technique is already brought in practice.This technique employs single layer coils to enhance the performance of MI waveguide.To further enhance the system functioning,in this paper,we investigated the performance of multi-layer coil(MLC)antenna based MI waveguide communication system in terms of transmission range,path loss,bit error rate(BER)and bandwidth.Besides,the system performance is quantitatively evaluated in three different non-conventional media viz.,dry soil,fresh water and wet soil.As compared with the single layer counterpart,the MLC system shows a significant improvement in transmission range,BER even in loosely coupled scenarios and shows a corresponding reduction in path loss.However,the bandwidth is observed to be low(<1 KHz).In this analysis,the eddy current effects and parasitic capacitance are compared for single and multilayer coils.It is observed that the proposed system performs better in dry soil medium due to less medium conductivity.展开更多
Nowadays,people still rely on traditional heating methods in rural areas of northern China,such as Kang(bed-stoves) and burning caves in cold winter.Field measurements of indoor environment were carried out in several...Nowadays,people still rely on traditional heating methods in rural areas of northern China,such as Kang(bed-stoves) and burning caves in cold winter.Field measurements of indoor environment were carried out in several rural houses with burning-cave-coil-Kang coupling heating system in northern China.The results show that this system is able to realize the graded use of internal energy of burning cave.The temperature of supply pipe water ranged from 30 ℃ to 50 ℃ which met the demands in 74.7% of time.The surface temperature of Kang maintained at above 25 ℃.Compared with traditional burning cave,using burning-cave-coil-Kang coupled with heating system has a higher thermal efficiency of 48.9%,which is 8.32% higher than the traditional one.展开更多
基金supported by the Startup Foundation of Shenyang Agriculture University(No.X2023050)the Fundamental Research Funds for the Central Universities(No.N2209006)the National Natural Science Foundation of China(No.U22A20173).
文摘To address the current issues with the conventional slide gate system utilized in the steel teeming process,a unique electromagnetic induction controlled automated steel teeming(EICAST)technology has been developed.Cooling means of spiral coil in this technology is directly related to its service life.Firstly,heat transfer processes of air cooling and spray cooling were compared and analyzed.Secondly,the impacts of water temperature,water flow rate and air flow rate were examined in order to maximize the spray cooling effect.To maintain coil temperature at a low value consistently throughout the entire thermal cycle process of the ladle,a combined cooling mode was finally employed.Numerical simulation was applied to examine the coil temperature variation with different cooling systems and characteristics.Before coil operation,spray cooling is said to be more effective.By controlling the water flow rate and air flow rate,the spray cooling effect is enhanced.However,water temperature has little or no impact when using spray cooling.Air cooling during the secondary refining process and spray cooling prior to coil operation are combined to further lower coil temperature.When the direction of the spray cooling is from bottom to top,the coil temperature is lowered below 165℃.A practical induction coil cooling plan was provided for the EICAST technology’s production process.
文摘The published article titled“MicroRNA-148a Acts as a Tumor Suppressor in Osteosarcoma via Targeting Rho-Associated Coiled-Coil Kinase”has been retracted from Oncology Research,Vol.25,No.8,2017,pp.1231–1243.DOI:10.3727/096504017X14850134190255 URL:https://www.techscience.com/or/v25n8/56908 Following the publication,concerns have been raised about a number of figures in this article.An unexpected area of similarity was identified in terms of the cellular data,where the results from differently performed experiments were intended to have been shown,although the areas immediately surrounding this area featured comparatively different distributions of cells.In addition,the western blots in this article were presented with atypical,unusually shaped and possibly anomalous protein bands in many cases.
文摘Coiled tube heat exchangers are widely preferred in shell structures due to their superior heat transfer performance,driven by favorable flow characteristics.This study investigates the effect of modifying coil and shell configurations on heat transfer efficiency.Two key enhancements were examined:adding fins to the outer coil surface and integrating longitudinal slots within a hollowed shell.These modifications promote turbulence and extend heat transfer duration,thereby improving performance.However,they also introduce challenges,including increased pressure loss andmanufacturing complexity.Numerical simulationswere conducted usingANSYS Fluent 2024R1 under identical boundary conditions.With a fixed cold-side flow rate of 3 L/min,the input temperatures for the hot and cold fluids were 333.15 and 291.65 K,respectively.The hot-side flow rate varied between 2 and 6 L/min.Simulation outcomes were reported for the objectives of the study that included the improvement in heat exchangers’heat transfer enhancement.As it was indicated in the study outcomes,the average heat transfer rate increased by 15.56%,the overall heat transfer coefficient enhanced by about 29.51%,and the convective heat transfer coefficient improved by about 75.96%compared to the conventional shell-and-coil tube heat exchanger model.However,the modified technique resulted in a significant pressure drop.
文摘Short suspension system has an indispensable effect on vehicle handling and ride,so,optimization of vehicle suspension system is one of the most effective methods,which could considerably enhance the vehicle stability and controllability.Motion control,stability maintenance and ride comfort improvement are fundamental issues in design of suspension system of off-road vehicles.In this work,a dependent suspension system mostly used in off-road vehicles is modeled using Trucksim software.Then,geometric parameters of suspension system are optimized using integrated anti-roll bar and coiling spring in a way that ride comfort,handling and stability of vehicle are improved.The simulation results of suspension system and variations of geometric parameters due to road roughness and different steering angles are presented in Trucksim and effects of optimization of suspension system during various driving maneuvers in both optimized and un-optimized conditions are compared.The simulation results indicate that the type of suspension system and geometric parameters have significant effect on vehicle performance.
文摘When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system.
基金financially supported by the National Natural Science Foundation of China (Grant No. U1560207)
文摘Ambient temperature of induction coil is an important factor to influence the implementation of the electromagnetic induction-controlled automated steel-teeming(EICAST) technology. Meanwhile, it also affects the formation of Fe–C alloy blocking layer, which determines the length and installation position of induction coil. An experimental platform was designed to imitate actual working conditions in a ladle with the EICAST system. Ambient temperature of induction coil under high-temperature condition was measured to verify the accuracy of numerical result. After containing molten steel for 120 min and steel teeming for 40 min, the ambient temperature on the upper side of induction coil is 791 °C. In addition, the position of blocking layer in a 110 t ladle was measured by sand-collection and steel-pour methods, and the criterion temperatures of blocking layer in numerical simulation process were corrected. When the refining temperature is1600 °C and the containing time of molten steel is 120 min, the thickness of blocking layer is 130 mm, and the distance between the upper surface of blocking layer and the upper surface of nozzle brick is 154 mm. When the criterion temperatures are 919 °C and 428 °C, the numerical results can be used to confirm the position of blocking layer and the installation position of induction coil.
基金supported by the National Key R&D Program of China (2022YFA1603001,2021YFC2801402)the National Nature Science Foundation of China (12073053)the Science and Technology Plan of Inner Mongolia (2021GG0245).
文摘Research on adaptive deformable mirror technology for voice coil actuators(VCAs)is an important trend in the development of large ground-based telescopes.A voice coil adaptive deformable mirror contains a large number of actuators,and there are problems with structural coupling and large temperature increases in their internal coils.Additionally,parameters of the traditional proportional integral derivative(PID)control cannot be adjusted in real-time to adapt to system changes.These problems can be addressed by introducing fuzzy control methods.A table lookup method is adopted to replace real-time calculations of the regular fuzzy controller during the control process,and a prototype platform has been established to verify the effectiveness and robustness of this process.Experimental tests compare the control performance of traditional and fuzzy proportional integral derivative(Fuzzy-PID)controllers,showing that,in system step response tests,the fuzzy control system reduces rise time by 20.25%,decreases overshoot by 78.24%,and shortens settling time by 67.59%.In disturbance rejection experiments,fuzzy control achieves a 46.09%reduction in the maximum deviation,indicating stronger robustness.The Fuzzy-PID controller,based on table lookup,outperforms the standard controller significantly,showing excellent potential for enhancing the dynamic performance and disturbance rejection capability of the voice coil motor actuator system.
基金Project supported by the Natural Science Foundation of the Ministry of Science and Technology of China (Grant No.2011ZX05008004)the Science Fund of the Committee of Science and Technology of Beijing,China
文摘Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and maximum wire width of gradient coils is one of the key solutions to minimize the maximum current density so as to reduce the local heating and generate higher magnetic field gradient strength. However, maximum current density is hard to optimize together with field linearity, stored magnetic energy, and power dissipation by the traditional target field method. In this paper, a new multi-objective method is proposed to optimize the maximum current density, field linearity, stored magnetic energy, and power dissipation in MRI gradient coils. The simulation and experimental results show that the minimum wire spacings are improved by 159% and 62% for the transverse and longitudinal gradient coil respectively. The maximum wire width increases from 0.5 mm to 1.5 mm. Maximum gradient field strengths of 157 mT/m and 405 mT/m for transverse and lon- gitudinal coil are achieved, respectively. The experimental results in BT-MRI instrument demonstrate that the MRI images with in-plane resolution of 50 ~tm can be obtained by using the designed coils.
基金supported by the National Magnetic Confinement Fusion Science Program of China(Nos.2014GB110000,2014GB110002)
文摘Integrating engineering software is meaningful but challenging for a system code of a fusion device. This issue is seldom considered by system codes currently. Therefore, to discuss the issue, the Integrated Design System of TF Coil (IDS-TFC) has been worked out, which consists of physical calculation, CAD, and Finite Element Analysis (FEA). Furthermore, an Integrated and Automatically Optimized Method (IAOM) has been created to address the integration and interfaces. The method utilizes a geometry parameter to connect each design submodule and achieve automatic optimization. Double-objectives optimization has been realized, confirming it is feasible to integrate and optimize engineering design and physical calculation. Moreover, IDS- TFC can also serve as a useful reference of integrated design processing for subsequent fusion design.
基金Project supported by the“Strategic Priority Research Program(B)”of the Chinese Academy of Sciences(Grant No.XDB04020200)the Shanghai Municipal Science and Technology Commission Project,China(Grant No.15DZ1940902)
文摘For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.
基金This work is funded by the Magnetic Resonance Union of the Chinese Academy of Sciences(Grant No.2021gzl002)the International Partnership Program of Chinese Academy of Sciences(Grant No.182111KYSB20210014)+1 种基金the National Science Foundation of China(Grant No.52293423,Grant No.52277031)the Research and Development of Key Technologies and Equipment for Major Science and Technology Infrastructure of Development and Reform Commission of Shenzhen Municipality,China(Grant No.ZDKJ20190305002).
文摘The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets.
基金National Natural Science Foundation of China(No.U1831123)。
文摘The quality of the stator winding coil directly affects the performance of the motor.A dual-camera online machine vision detection method to detect whether the coil leads and winding regions were qualified was designed.A vision detection platform was designed to capture individual winding images,and an image processing algorithm was used for image pre-processing,template matching and positioning of the coil lead area to set up a coordinate system.After eliminating image noise by Blob analysis,the improved Canny algorithm was used to detect the location of the coil lead paint stripped region,and the time was reduced by about half compared to the Canny algorithm.The coil winding region was trained with the ShuffleNet V2-YOLOv5s model for the dataset,and the detect file was converted to the Open Neural Network Exchange(ONNX)model for the detection of winding cross features with an average accuracy of 99.0%.The software interface of the detection system was designed to perform qualified discrimination tests on the workpieces,and the detection data were recorded and statistically analyzed.The results showed that the stator winding coil qualified discrimination accuracy reached 96.2%,and the average detection time of a single workpiece was about 300 ms,while YOLOv5s took less than 30 ms.
基金Supported by the China National Science and Technology Major Project(2016ZX05020-004)
文摘There are many problems associated with coiled tubing drilling operations, such as great circulation pressure loss inside pipe, difficulties in weight on bit(WOB) transferring, and high probability of differential sticking. Aiming at these problems, solids-free brine drilling fluid system was developed on the basis of formulation optimization with brine base fluid experiment, which was evaluated and applied to field drilling. Based on the optimization of flow pattern regulator, salt-resisting filtrate reducer, high performance lubricant and bit cleaner, the basic formula of the solids-free brine drilling fluid system was formed: brine +(0.1%-0.2%) Na OH +(0.2%-0.4%) HT-XC +(2.0%-3.0%) YLJ-1 +(0.5%-2.0%) SDNR +(1.0%-2.5%) FT-1 A +(1.0%-5.0%) SD-505 + compound salt density regulator. Lab evaluation showed that the fluid had satisfactory temperature resistance(up to 150 ℃), excellent cuttings tolerance(up to 25%), and strong inhibition(92.7% cuttings recovery); Moreover, its lubrication performance was similar to that of all oil-based drilling fluid. The wellbore could be fairly cleaned at annular up-flow velocity of more than 0.8 m/s if the ratio of yield point to plastic viscosity was kept above 0.5. This fluid system has been applied in the drilling of three coiled tubing sidetracking wells in the Liaohe Oilfield, during which the system was stable and easy to adjust, resulting in excellent cuttings transportation, high ROP, regular hole size, and no down hole accidents. In summary, the solids-free brine drilling fluid system can meet the technical requirements of coiled tubing drilling.
文摘Embolization of collateral veins is often treated with rigid coils(Gianturco and interlocking detachable coils type).However,when dealing with tortuous and dilated collateral veins,there is a high risk for technical failure and coil migration due to inflexibility of the coils.To safely and successfully solve this problem,Guglielmi detachable coils(GDC) can be used for embolization.Their flexibility allows for easy navigation in tortuous veins,low risk of unintended coil release or coil migration,and safe deployment.A 12-year-old girl with a single ventricle had severe cyanosis and a low exercise tolerance 5 years after Fontan procedure.The symp-toms were caused by a tortuous and dilated collateral from the left phrenic vein into the left pulmonary vein,forming a right-to-left shunt.The collateral,which had a large diameter and high flow,and therefore a high risk of coil migration,was successfully embolized with 8 GDC.There were no complications such as coil migration or cerebral infarction.Transcatheter embolization increased her systemic oxygen saturation from 81%-84% to 94%-95%,and increased her ability to exercise.The embolization procedure using flexible GDC was low risk compared with other rigid coil embolization techniques when performing embolization of tortuous and dilated collateral veins.
基金Project(56605011) supported by the National Natural Science Foundation of China
文摘Based on the method of controlling welding stress with trailing, the electromagnetic force in coil-sheet system was simulated with finite element software ANSYS. The effect of parameters of coil on the electromagnetic force density fy was analyzed. The results show that the maximum electromagnetic force density fy, max in sheet appears in the position near the inner radius of single-turn coil. The position is independent of section shape of coil. fy, max for flat coil is larger than that for long coil and the coil with wedge shape section, while section areas of all coils are equal to each other. The effect of turn number of multiple-turn coil on fy is dependent on the loop resistance in circuit. The kind of coil with more turns and larger inductance is commended while there is larger loop resistance in circuit. fy increases in a certain magnitude while a magnetic core is located in coil. However, the magnitude of fy is limited by saturating magnetic flux of the core.
文摘In the non-conventional media like underwater and underground,the Radio Frequency(RF)communication technique does not perform well due to large antenna size requirement and high path loss.In such media,magnetic induction(MI)communication technique is very promising due to small coil size and constant channel behavior.Unlike the RF technique,the communication range in MI technique is relatively less.To enhance this range,a waveguide technique is already brought in practice.This technique employs single layer coils to enhance the performance of MI waveguide.To further enhance the system functioning,in this paper,we investigated the performance of multi-layer coil(MLC)antenna based MI waveguide communication system in terms of transmission range,path loss,bit error rate(BER)and bandwidth.Besides,the system performance is quantitatively evaluated in three different non-conventional media viz.,dry soil,fresh water and wet soil.As compared with the single layer counterpart,the MLC system shows a significant improvement in transmission range,BER even in loosely coupled scenarios and shows a corresponding reduction in path loss.However,the bandwidth is observed to be low(<1 KHz).In this analysis,the eddy current effects and parasitic capacitance are compared for single and multilayer coils.It is observed that the proposed system performs better in dry soil medium due to less medium conductivity.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51178075)the Fundamental Research Funds for the Central Universities(Grant No.DUT17RW118)
文摘Nowadays,people still rely on traditional heating methods in rural areas of northern China,such as Kang(bed-stoves) and burning caves in cold winter.Field measurements of indoor environment were carried out in several rural houses with burning-cave-coil-Kang coupling heating system in northern China.The results show that this system is able to realize the graded use of internal energy of burning cave.The temperature of supply pipe water ranged from 30 ℃ to 50 ℃ which met the demands in 74.7% of time.The surface temperature of Kang maintained at above 25 ℃.Compared with traditional burning cave,using burning-cave-coil-Kang coupled with heating system has a higher thermal efficiency of 48.9%,which is 8.32% higher than the traditional one.