Physico-Chemical and Biological Characteristics of Stagnant Surface Water Bodies (Ponds and Lakes) Used for Drinking and Domestic Purposes in Niger Delta, Nigeria
1
作者 Akpofure Rim-Rukeh 《Journal of Environmental Protection》 2013年第9期920-928,共9页
The surface water quality of some stagnant water bodies (ponds and lakes—Obi Lake, Usede pond, Oguta lake, Omuku pond, Ugheghe pond, Karabodone lake, Abua lake, Ikarama lake, Tenmako lake, and Adiegbe lake) in the Ni... The surface water quality of some stagnant water bodies (ponds and lakes—Obi Lake, Usede pond, Oguta lake, Omuku pond, Ugheghe pond, Karabodone lake, Abua lake, Ikarama lake, Tenmako lake, and Adiegbe lake) in the Niger Delta area of Nigeria have been investigated experimentally by analysing the physico-chemical and biological characteristics of the surface water samples. Results show: pH (5.10 - 7.40), temperature (26.4°C - 31.0°C), turbidity (7.83 - 27.7NTU), electrical conductivity (13.5 - 34.8 μS/cm), biochemical oxygen demand (BOD) (1.07 - 19.5 mg/l), chemical oxygen demand (COD) (1.90 - 21.5 mg/l), suspended solids (SS) (9.70 - 37.3 mg/l), dissolved oxygen (DO) (2.7 - 8.7 mg/l), total dissolved solids (TDS) (33.8 - 187.0 mg/l), total phosphorus (0.73 - 2.47 mg/l), ammoniacal nitrogen (AN) (0.018 - 4.70 mg/l) and total fecal coliform count (TFCC) (nil - 2175 cfu/ml). Results on the water quality using Malaysian Water Quality Index (WQI) show that Usede pond and Obi Lake belong to Class II with values that are 75.24 and 76.73 respectively. The WQI of Oguta lake, Omuku pond, Ugheghe pond, Karabodone lake and Abua lake are 67.46, 65.64, 65.87, 50.77, and 67.01 respectively and belongs to class III. The WQI of Ikarama lake, Tenmako lake, and Adiegbe lake are 43.38, 37.60, and 41.40, respectively and belongs to class IV and is described as fair. 展开更多
关键词 Malaysian water Quality Index Sewage DRINKING water PONDS LAKES class II water class iii water class IV water
暂未订购
一种切割装置对COD的去除作用研究
2
作者 王政福 袁劲梅 +1 位作者 朱来松 赵珍 《山东化工》 CAS 2021年第24期244-248,共5页
根据目前城镇污水厂提标改造至“准Ⅳ类水”标准的要求及农村生活污水水量、水质的变化较大的情况,在污水处理设备上加设一种切割装置,提高污染物去除率。经过试验发现,切割装置有助于COD、氨氮的去除,其去除率分别增加约7.32%,5.75%,BO... 根据目前城镇污水厂提标改造至“准Ⅳ类水”标准的要求及农村生活污水水量、水质的变化较大的情况,在污水处理设备上加设一种切割装置,提高污染物去除率。经过试验发现,切割装置有助于COD、氨氮的去除,其去除率分别增加约7.32%,5.75%,BOD容积负荷可提高约20.83%,低温(5~9℃)条件下,出水COD平均值小于20 mg/L,达到III类水标准;出水COD值均低于30 mg/L,达到了IV类水排放标准,有效降低低温对生化系统带来的不利影响。 展开更多
关键词 IV类水 iii类水 BOD容积负荷
在线阅读 下载PDF
复合型人工湿地在污水处理厂尾水深度处理中的应用
3
作者 袁茜 吴庆明 贾涛涛 《皮革制作与环保科技》 2022年第10期129-130,139,共3页
为了使成都市新都区苟家滩引水枢纽上游两座污水处理厂达到《四川省岷江、沱江流域水污染物排放标准》(DB51/2311-2016)的尾水得到进一步深度处理,并使其达到《地表水环境质量标准》(GB 3838-2002)中的Ⅲ类水指标限值,构建了一种复合型... 为了使成都市新都区苟家滩引水枢纽上游两座污水处理厂达到《四川省岷江、沱江流域水污染物排放标准》(DB51/2311-2016)的尾水得到进一步深度处理,并使其达到《地表水环境质量标准》(GB 3838-2002)中的Ⅲ类水指标限值,构建了一种复合型人工湿地污水处理系统。该人工湿地设计处理规模为7×10^(4) m^(3)/d,采用了多级串联的复合型人工湿地。该工程的实施,进一步保障了毗河供水工程水质,是污水处理厂厂外提标的典型案例,具有较好的示范作用。 展开更多
关键词 污水处理厂尾水 复合型人工湿地 Ⅲ类水质标准