This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on...This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly.展开更多
This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage cir...This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage circuit breakers was analyzed so that measures to improve instantaneous protection reliability can be determined. Furthermore, the theory of the instantaneous characteristics calibration device for low voltage circuit breakers and the method of eliminating the non-periodic component of test current are given in detail. Finally, the test results are presented.展开更多
Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit ...Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit based on current-comparing method is designed to protect the electronics away from SEL’s damage in radiation environment. The response time of protection circuit has been analyzed. The signal simulation results indicated that the operating time of the SEL protection circuit is dependent on the action time of current comparator and system application recovery time. The function of the monitoring circuit protection device away from SEL’s damage has validated through experiment at last.展开更多
Based on 2-D device simulations and mixed-mode transient simulations, DC and transient discharge characteristics of a usual diode string utilizing a standard CMOS process, and a diode string utilizing a triple-well CM...Based on 2-D device simulations and mixed-mode transient simulations, DC and transient discharge characteristics of a usual diode string utilizing a standard CMOS process, and a diode string utilizing a triple-well CMOS process, which can serve as an essential VDD-VSS clamp device for CMOS input ESD protection were compared. Transient discharge characteristics including peak voltages developed across gates oxides of transistors in input buffers, lattice heating inside ESD protection devices, and ratios of discharge current components at its peak inside the diode-string clamp were compared. DC standby current levels added per each input pad structure, which are the critical parameters determining usefulness of the devices, were also compared. We showed that the diode-string devices in comparison can serve successfully as a VDD-VSS clamp device for ESD protection by virtue of the dominant pnpn thyristor-related conduction mechanisms. Optimization of design parameters including anode-cathode contact spacing in each diode in the string, device width of the diode string, and number of diodes in the diode string was performed to present transient discharge and DC characteristics of some recommendable design examples, which can serve as a guideline in designing diode-string clamp devices.展开更多
The electrostatic discharge(ESD)protection circuit widely exists in the input and output ports of CMOS digital circuits,and fast rising time electromagnetic pulse(FREMP)coupled into the device not only interacts with ...The electrostatic discharge(ESD)protection circuit widely exists in the input and output ports of CMOS digital circuits,and fast rising time electromagnetic pulse(FREMP)coupled into the device not only interacts with the CMOS circuit,but also acts on the protection circuit.This paper establishes a model of on-chip CMOS electrostatic discharge protection circuit and selects square pulse as the FREMP signals.Based on multiple physical parameter models,it depicts the distribution of the lattice temperature,current density,and electric field intensity inside the device.At the same time,this paper explores the changes of the internal devices in the circuit under the injection of fast rising time electromagnetic pulse and describes the relationship between the damage amplitude threshold and the pulse width.The results show that the ESD protection circuit has potential damage risk,and the injection of FREMP leads to irreversible heat loss inside the circuit.In addition,pulse signals with different attributes will change the damage threshold of the circuit.These results provide an important reference for further evaluation of the influence of electromagnetic environment on the chip,which is helpful to carry out the reliability enhancement research of ESD protection circuit.展开更多
In order to obtain reasonable schemes of arrester in converter stations, the arrester scheme of "Xiluodu-Guangdong HVDC ± 500 kV double circuit transmission" project against lighting induced overvoltage...In order to obtain reasonable schemes of arrester in converter stations, the arrester scheme of "Xiluodu-Guangdong HVDC ± 500 kV double circuit transmission" project against lighting induced overvoltage, which was designed according to the main principle of lightning protection in converter station, is discussed. A calculation of the lighting induced overvoltage in Zhaotong converter station un- der various operation modes is performed with ATP-EMTP software, then the surge arrester configuration of the converter station is decided, and the arrester protection schemes of smoothing reactor and neutral line are studied. It is concluded that additional protection is necessary because of the relatively large gap between protected disconnecting switch and arrester of metallic return transfer bus. Plus, the smoothing reactor (SR) arrester near the valve hall could be removed to improve the scheme’s economic performance.展开更多
This paper analyzes a DFIG (doubly fed induction generator) WT (wind turbine) fault current after a symmetrical network voltage dip. The goal is to identify the factors determining how fast the first zero crossing...This paper analyzes a DFIG (doubly fed induction generator) WT (wind turbine) fault current after a symmetrical network voltage dip. The goal is to identify the factors determining how fast the first zero crossings of the fault current occur. This is an important subject because the ftmdamental property of the CB (circuit breaker) is that it breaks the current when the current is very near zero. The study was conducted using a hardware-in-the-loop test environment constructed using two real time simulators (dSPACE and RTDS) and a commercial protection relay. It is found that the reactive current injection during a voltage dip demanded by the grid codes enhances the operation of the WT protection because the zero crossings of the currents through CB are attained earlier. In addition, the size of the crowbar resistance has a significant influence on the zero crossings.展开更多
Patterns of spatial development and protection form a basic category of geoscience,and redesigning them is a popular subject of research in regional sustainable development that is important for ecological civilizatio...Patterns of spatial development and protection form a basic category of geoscience,and redesigning them is a popular subject of research in regional sustainable development that is important for ecological civilization construction.The authors here report a case study of Wuhan city using the circuit theory model and minimum cumulative resistance(MCR)model to rebalance its spatial protection and development.The results show the following:(1)Using the density of the gross domestic product(GDP),density of population,rate of urbanization,and access to transportation as evaluation indicators,seven core areas of development in Wuhan were identified,accounting for 59%of the total number of streets,that exhibited a “circular-satellite”spatial structure.(2)According to the importance of ecosystem services,ecological sensitivity,land use type,and slope of the terrain,the resistance surface of spatial development in Wuhan had a stereoscopic spatial form of an“inverted pyramid,”with high surroundings and a low center.The area of low resistance accounted for 6.64%of the total area of Wuhan.(3)Based on coupling analysis using the MCR and spatial morphological characteristics of current,nine axes of spatial development with a total area of 427.27 km2 and eight key strategic points with a total area of 40.02 km2 were identified.Streets that were prioritized for development accounted for 9.63%of Wuhan's total area.(4)By combining the characterization of the development axis with the structure of the three-level core area,we extracted the structure of spatial development of "one heart,two wings,and three belts" in Wuhan.The research framework and empirical results can provide scientific guidance for the urban spatial layout,the development of regional linkages,and ecological environmental protection in China.展开更多
The caudal forelimb area(CFA)of the mouse cortex is essential in many forelimb movements,and diverse types of GABAergic interneuron in the CFA are distinct in the mediation of cortical inhibition in motor information ...The caudal forelimb area(CFA)of the mouse cortex is essential in many forelimb movements,and diverse types of GABAergic interneuron in the CFA are distinct in the mediation of cortical inhibition in motor information processing.However,their long-range inputs remain unclear.In the present study,we combined the monosynaptic rabies virus system with Cre driver mouse lines to generate a whole-brain map of the inputs to three major inhibitory interneuron types in the CFA.We discovered that each type was innervated by the same upstream areas,but there were quantitative differences in the inputs from the cortex,thalamus,and pallidum.Comparing the locations of the interneurons in two subregions of the CFA,we discovered that their long-range inputs were remarkably different in distribution and proportion.This whole-brain mapping indicates the existence of parallel pathway organization in the forelimb subnetwork and provides insight into the inhibitory processes in forelimb movement to reveal the structural architecture underlying the functions of the CFA.展开更多
Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage...Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage caused by lightning stroke. The simplified lumped-parameter circuit model and the circuit method were used to study the protection distance problem of SPDs. The analytical solutions of the load voltage and general equations of the protection distance of SPDs under different load conditions were given. Simulation results of examples proved the validity of the proposed analytical method.展开更多
To increase corrosion resistance of the sample,its electrical impedance must be increased.Due to the fact that electrical impedance depends on elements such as electrical resistance,capacitance,and inductance,by incre...To increase corrosion resistance of the sample,its electrical impedance must be increased.Due to the fact that electrical impedance depends on elements such as electrical resistance,capacitance,and inductance,by increasing the electrical resistance,reducing the capacitance and inductance,electrical impedance and corrosion resistance can be increased.Based on the fact that these elements depend on the type of material and the geometry of the material,multilayer structures with different geometries are proposed.For this purpose,conventional multilayer thin films,multilayer thin film including zigzag structure(zigzag 1)and multilayer thin film including double zigzag structure(zigzag 2)of manganese nitride are considered to protect AISI 304 stainless steel against corrosion in salt solution.These multilayer coatings including zigzag structures are prepared by alternately using the conventional deposition of thin film and glancing angle deposition method.After deposition,the samples are placed in a furnace under nitrogen flux for nitriding.The cross sections of the structures are observed by field emission scanning electron microscopy(FESEM).Atomic force microscope(AFM)is used to make surface analyses of the samples.The results show that the multilayer thin films including zigzag structures have smaller grains than conventional multilayer thin films,and the zigzag 2 structure has the smaller grain than the other two samples,which is attributed to the effect of shadowing and porosity on the oblique angle deposition method.Crystallography structures of the samples are studied by using x-ray diffraction(XRD)pattern and the results show that nitride phase formation in zigzag 2 structure is better than that in zigzag 1 structure and conventional multilayer thin film.To investigate the corrosion resistances of the structures,electrochemical impedance spectroscopy(EIS)and potentiodynamic polarization tests are performed.The results reveal that the multilayer thin films with zigzag structures have better corrosion protection than the conventional multilayer thin films,and the zigzag structure 2 has the smallest corrosion current and the highest corrosion resistance.The electrical impedances of the samples are investigated by simulating equivalent circuits.The high corrosion resistance of zigzag 2 structure as compared with conventional multilayer structure and zigzag 1 structure,is attributed to the high electrical impedance of the structure due to its small capacitance and high electrical resistance.Finally,the surfaces of corroded samples are observed by scanning electron microscope(SEM).展开更多
To reduce the pressure on contacts and circuit breaker and realize the zone selective interlocking (ZSI) function above the instantaneous protection threshold (e.g., >10In), the short circuit current needs to be ea...To reduce the pressure on contacts and circuit breaker and realize the zone selective interlocking (ZSI) function above the instantaneous protection threshold (e.g., >10In), the short circuit current needs to be early detected. The state-of–art of early short circuit detection (ESCD) method is reviewed. Based on the equivalent model of the short circuit, a new method based on the current and its integration is proposed. The prospective current value can be detected in the early stage of the short circuit. According to the evaluation result, the short circuit current can be early forecasted with the proposed method.展开更多
High quality electricity services are the prime objectives in the modern power systems around the world. One of the main players to achieve this is the protection of the system which needs to be fast, reliable and cos...High quality electricity services are the prime objectives in the modern power systems around the world. One of the main players to achieve this is the protection of the system which needs to be fast, reliable and cost effective. The study about the protection of the Low Voltage (LV) CIGRE distribution grid and networks like this has been proposed in this paper. The main objective of this paper is to develop protection against short circuit faults which might appear anywhere in the network. The protection of the power networks that comprises of renewable energy generation units is complicated because of the bidirectional flow of the current and is a challenge for the protection engineers. The selection of the protection devices in this paper is made to protect the network against faults in grid connected and island mode of operation. Ultra-fast fuses are proposed in order to protect the inverters used for Photovoltaic (PV) and battery applications. The disconnection of the PV solar panels when in island mode is made by proposing switch disconnecting devices. ABB is currently using these kinds of disconnection devices for the purpose of protecting solar panels against over voltages in the case of islanding. The over speed protection of the existing Wind Turbine Generator (WTG) in the CIGRE network in case of grid loss is also proposed in this paper.展开更多
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th...In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.展开更多
When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads t...When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved.展开更多
We have finished the research and development of multi-step temperature control system.The output circuits implement the interface between the control system and oven. It receives pulsed signals for increasing or decr...We have finished the research and development of multi-step temperature control system.The output circuits implement the interface between the control system and oven. It receives pulsed signals for increasing or decreasing temperature from MCS-8051.The circuit diagram is shown as follows.展开更多
To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreemen...To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreement has not been reached so far.The SCC characteristics for different wind generators are studied.PSCAD simulation is performed in the same system integrated with different kinds of wind generators,and their results are compared with those reported in IEEE papers.The detection possibility by overcurrent relay(OCR)is discussed based on the simulation results.展开更多
Aggression,an evolutionarily conserved social behavior,is essential for animals to compete for valuable resources like food,territory,and mates,and to protect kin.Although aggression is required for the survival of bo...Aggression,an evolutionarily conserved social behavior,is essential for animals to compete for valuable resources like food,territory,and mates,and to protect kin.Although aggression is required for the survival of both sexes,it is often displayed in a sexually dimorphic manner,with males typically exhibiting higher levels of aggression than females.展开更多
The essential requirements of IGBT drive circuit is expounded.The short-circuit characteristic and over-current protection of the IGBT are described in detail.Finally,the practical drive and protection circuits are de...The essential requirements of IGBT drive circuit is expounded.The short-circuit characteristic and over-current protection of the IGBT are described in detail.Finally,the practical drive and protection circuits are designed.The practical results show that the circuit is good in performance.展开更多
基金Project (No. E2005000039) supported by the Natural Science Foun-dation of Hebei Province, China
文摘This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly.
基金Project (No. 043804411) supported by the Tianjin Natural ScienceFoundation, China
文摘This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage circuit breakers was analyzed so that measures to improve instantaneous protection reliability can be determined. Furthermore, the theory of the instantaneous characteristics calibration device for low voltage circuit breakers and the method of eliminating the non-periodic component of test current are given in detail. Finally, the test results are presented.
文摘Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit based on current-comparing method is designed to protect the electronics away from SEL’s damage in radiation environment. The response time of protection circuit has been analyzed. The signal simulation results indicated that the operating time of the SEL protection circuit is dependent on the action time of current comparator and system application recovery time. The function of the monitoring circuit protection device away from SEL’s damage has validated through experiment at last.
文摘Based on 2-D device simulations and mixed-mode transient simulations, DC and transient discharge characteristics of a usual diode string utilizing a standard CMOS process, and a diode string utilizing a triple-well CMOS process, which can serve as an essential VDD-VSS clamp device for CMOS input ESD protection were compared. Transient discharge characteristics including peak voltages developed across gates oxides of transistors in input buffers, lattice heating inside ESD protection devices, and ratios of discharge current components at its peak inside the diode-string clamp were compared. DC standby current levels added per each input pad structure, which are the critical parameters determining usefulness of the devices, were also compared. We showed that the diode-string devices in comparison can serve successfully as a VDD-VSS clamp device for ESD protection by virtue of the dominant pnpn thyristor-related conduction mechanisms. Optimization of design parameters including anode-cathode contact spacing in each diode in the string, device width of the diode string, and number of diodes in the diode string was performed to present transient discharge and DC characteristics of some recommendable design examples, which can serve as a guideline in designing diode-string clamp devices.
基金National Natural Science Foundation of China(61974116)。
文摘The electrostatic discharge(ESD)protection circuit widely exists in the input and output ports of CMOS digital circuits,and fast rising time electromagnetic pulse(FREMP)coupled into the device not only interacts with the CMOS circuit,but also acts on the protection circuit.This paper establishes a model of on-chip CMOS electrostatic discharge protection circuit and selects square pulse as the FREMP signals.Based on multiple physical parameter models,it depicts the distribution of the lattice temperature,current density,and electric field intensity inside the device.At the same time,this paper explores the changes of the internal devices in the circuit under the injection of fast rising time electromagnetic pulse and describes the relationship between the damage amplitude threshold and the pulse width.The results show that the ESD protection circuit has potential damage risk,and the injection of FREMP leads to irreversible heat loss inside the circuit.In addition,pulse signals with different attributes will change the damage threshold of the circuit.These results provide an important reference for further evaluation of the influence of electromagnetic environment on the chip,which is helpful to carry out the reliability enhancement research of ESD protection circuit.
基金Project supported by Key Project of National Natural Science Foundation of China (50737003).
文摘In order to obtain reasonable schemes of arrester in converter stations, the arrester scheme of "Xiluodu-Guangdong HVDC ± 500 kV double circuit transmission" project against lighting induced overvoltage, which was designed according to the main principle of lightning protection in converter station, is discussed. A calculation of the lighting induced overvoltage in Zhaotong converter station un- der various operation modes is performed with ATP-EMTP software, then the surge arrester configuration of the converter station is decided, and the arrester protection schemes of smoothing reactor and neutral line are studied. It is concluded that additional protection is necessary because of the relatively large gap between protected disconnecting switch and arrester of metallic return transfer bus. Plus, the smoothing reactor (SR) arrester near the valve hall could be removed to improve the scheme’s economic performance.
文摘This paper analyzes a DFIG (doubly fed induction generator) WT (wind turbine) fault current after a symmetrical network voltage dip. The goal is to identify the factors determining how fast the first zero crossings of the fault current occur. This is an important subject because the ftmdamental property of the CB (circuit breaker) is that it breaks the current when the current is very near zero. The study was conducted using a hardware-in-the-loop test environment constructed using two real time simulators (dSPACE and RTDS) and a commercial protection relay. It is found that the reactive current injection during a voltage dip demanded by the grid codes enhances the operation of the WT protection because the zero crossings of the currents through CB are attained earlier. In addition, the size of the crowbar resistance has a significant influence on the zero crossings.
基金National Natural Science Foundation of China,No.71974070,No.41501593Social Sciences Foundation of Ministry of Education of China,No.19YJCZH068Scientific Research Project of Hubei Provincial Natural Resources Department,No.ZRZY2019KY08。
文摘Patterns of spatial development and protection form a basic category of geoscience,and redesigning them is a popular subject of research in regional sustainable development that is important for ecological civilization construction.The authors here report a case study of Wuhan city using the circuit theory model and minimum cumulative resistance(MCR)model to rebalance its spatial protection and development.The results show the following:(1)Using the density of the gross domestic product(GDP),density of population,rate of urbanization,and access to transportation as evaluation indicators,seven core areas of development in Wuhan were identified,accounting for 59%of the total number of streets,that exhibited a “circular-satellite”spatial structure.(2)According to the importance of ecosystem services,ecological sensitivity,land use type,and slope of the terrain,the resistance surface of spatial development in Wuhan had a stereoscopic spatial form of an“inverted pyramid,”with high surroundings and a low center.The area of low resistance accounted for 6.64%of the total area of Wuhan.(3)Based on coupling analysis using the MCR and spatial morphological characteristics of current,nine axes of spatial development with a total area of 427.27 km2 and eight key strategic points with a total area of 40.02 km2 were identified.Streets that were prioritized for development accounted for 9.63%of Wuhan's total area.(4)By combining the characterization of the development axis with the structure of the three-level core area,we extracted the structure of spatial development of "one heart,two wings,and three belts" in Wuhan.The research framework and empirical results can provide scientific guidance for the urban spatial layout,the development of regional linkages,and ecological environmental protection in China.
基金supported by the National Natural Science Foundation of China(61721092,91749209,and 31871088)the Director Fund of Wuhan National Laboratory for Optoelectronics。
文摘The caudal forelimb area(CFA)of the mouse cortex is essential in many forelimb movements,and diverse types of GABAergic interneuron in the CFA are distinct in the mediation of cortical inhibition in motor information processing.However,their long-range inputs remain unclear.In the present study,we combined the monosynaptic rabies virus system with Cre driver mouse lines to generate a whole-brain map of the inputs to three major inhibitory interneuron types in the CFA.We discovered that each type was innervated by the same upstream areas,but there were quantitative differences in the inputs from the cortex,thalamus,and pallidum.Comparing the locations of the interneurons in two subregions of the CFA,we discovered that their long-range inputs were remarkably different in distribution and proportion.This whole-brain mapping indicates the existence of parallel pathway organization in the forelimb subnetwork and provides insight into the inhibitory processes in forelimb movement to reveal the structural architecture underlying the functions of the CFA.
文摘Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage caused by lightning stroke. The simplified lumped-parameter circuit model and the circuit method were used to study the protection distance problem of SPDs. The analytical solutions of the load voltage and general equations of the protection distance of SPDs under different load conditions were given. Simulation results of examples proved the validity of the proposed analytical method.
基金Project supported by the Funds from the University of Mohaghegh Ardabili and University of Tehran and the Iran National Science Foundation(INSF)the Centre of Excellence for Physics of Structure and Microscopic Properties of Matter,Department of Physics,University of Tehran.
文摘To increase corrosion resistance of the sample,its electrical impedance must be increased.Due to the fact that electrical impedance depends on elements such as electrical resistance,capacitance,and inductance,by increasing the electrical resistance,reducing the capacitance and inductance,electrical impedance and corrosion resistance can be increased.Based on the fact that these elements depend on the type of material and the geometry of the material,multilayer structures with different geometries are proposed.For this purpose,conventional multilayer thin films,multilayer thin film including zigzag structure(zigzag 1)and multilayer thin film including double zigzag structure(zigzag 2)of manganese nitride are considered to protect AISI 304 stainless steel against corrosion in salt solution.These multilayer coatings including zigzag structures are prepared by alternately using the conventional deposition of thin film and glancing angle deposition method.After deposition,the samples are placed in a furnace under nitrogen flux for nitriding.The cross sections of the structures are observed by field emission scanning electron microscopy(FESEM).Atomic force microscope(AFM)is used to make surface analyses of the samples.The results show that the multilayer thin films including zigzag structures have smaller grains than conventional multilayer thin films,and the zigzag 2 structure has the smaller grain than the other two samples,which is attributed to the effect of shadowing and porosity on the oblique angle deposition method.Crystallography structures of the samples are studied by using x-ray diffraction(XRD)pattern and the results show that nitride phase formation in zigzag 2 structure is better than that in zigzag 1 structure and conventional multilayer thin film.To investigate the corrosion resistances of the structures,electrochemical impedance spectroscopy(EIS)and potentiodynamic polarization tests are performed.The results reveal that the multilayer thin films with zigzag structures have better corrosion protection than the conventional multilayer thin films,and the zigzag structure 2 has the smallest corrosion current and the highest corrosion resistance.The electrical impedances of the samples are investigated by simulating equivalent circuits.The high corrosion resistance of zigzag 2 structure as compared with conventional multilayer structure and zigzag 1 structure,is attributed to the high electrical impedance of the structure due to its small capacitance and high electrical resistance.Finally,the surfaces of corroded samples are observed by scanning electron microscope(SEM).
文摘To reduce the pressure on contacts and circuit breaker and realize the zone selective interlocking (ZSI) function above the instantaneous protection threshold (e.g., >10In), the short circuit current needs to be early detected. The state-of–art of early short circuit detection (ESCD) method is reviewed. Based on the equivalent model of the short circuit, a new method based on the current and its integration is proposed. The prospective current value can be detected in the early stage of the short circuit. According to the evaluation result, the short circuit current can be early forecasted with the proposed method.
文摘High quality electricity services are the prime objectives in the modern power systems around the world. One of the main players to achieve this is the protection of the system which needs to be fast, reliable and cost effective. The study about the protection of the Low Voltage (LV) CIGRE distribution grid and networks like this has been proposed in this paper. The main objective of this paper is to develop protection against short circuit faults which might appear anywhere in the network. The protection of the power networks that comprises of renewable energy generation units is complicated because of the bidirectional flow of the current and is a challenge for the protection engineers. The selection of the protection devices in this paper is made to protect the network against faults in grid connected and island mode of operation. Ultra-fast fuses are proposed in order to protect the inverters used for Photovoltaic (PV) and battery applications. The disconnection of the PV solar panels when in island mode is made by proposing switch disconnecting devices. ABB is currently using these kinds of disconnection devices for the purpose of protecting solar panels against over voltages in the case of islanding. The over speed protection of the existing Wind Turbine Generator (WTG) in the CIGRE network in case of grid loss is also proposed in this paper.
文摘In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.
基金supported by the Natural Science Foundation of Sichuan Province(No.2022NSFSC0405).
文摘When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved.
文摘We have finished the research and development of multi-step temperature control system.The output circuits implement the interface between the control system and oven. It receives pulsed signals for increasing or decreasing temperature from MCS-8051.The circuit diagram is shown as follows.
基金supported by the Power Generation & Electricity Delivery of the Korea Institute of Energy Technology and Planning(KETEP)grant funded by the Korea Government Ministry of Knowledge Economy(No.2009T100200067)
文摘To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreement has not been reached so far.The SCC characteristics for different wind generators are studied.PSCAD simulation is performed in the same system integrated with different kinds of wind generators,and their results are compared with those reported in IEEE papers.The detection possibility by overcurrent relay(OCR)is discussed based on the simulation results.
基金supported by the New Cornerstone Science Foundation and the Key R&D Program of Zhejiang(2024SSYS0016).
文摘Aggression,an evolutionarily conserved social behavior,is essential for animals to compete for valuable resources like food,territory,and mates,and to protect kin.Although aggression is required for the survival of both sexes,it is often displayed in a sexually dimorphic manner,with males typically exhibiting higher levels of aggression than females.
文摘The essential requirements of IGBT drive circuit is expounded.The short-circuit characteristic and over-current protection of the IGBT are described in detail.Finally,the practical drive and protection circuits are designed.The practical results show that the circuit is good in performance.