BACKGROUND Bacterial contamination during colonoscopy is a significant concern,yet few studies have evaluated bacterial aerosols.This study aimed to determine whether covering the biopsy hole check valve with enzymoly...BACKGROUND Bacterial contamination during colonoscopy is a significant concern,yet few studies have evaluated bacterial aerosols.This study aimed to determine whether covering the biopsy hole check valve with enzymolysis gauze(refers to sterile gauze soaked in a multi-enzyme cleaning solution)reduces bacterial air pollution in endoscopy rooms.AIM To evaluate the efficacy of an enzymolysis gauze cover in reducing bacterial aerosols from the biopsy valve.METHODS This prospective,single-blind trial included 80 patients undergoing elective diagnostic colonoscopy.During the procedure,the biopsy hole check valve was either covered or left uncovered with enzymolysis gauze.Air samples(100 L)were collected at a distance of 30 cm from the biopsy hole check valve and approximately 140 cm above the floor using a percussive air sampling instrument.Gram-positive bacteria were cultured on standard 90 mm colimycin nalidixic agar blood plates.The primary outcome measures were bacterial load and species identification.RESULTS Covering the biopsy hole check valve with enzymolysis gauze reduced bacterial load near the check valve from 50 colony-forming unit(CFU)/m^(3)[interquartile range(IQR):30-80]to 20 CFU/m^(3)(IQR:10-20).At the end of the procedure each day,covering the valve also decreased bacterial load in the endoscopy room from 35 CFU/m^(3)(IQR:33-85)to 10 CFU/m^(3)(IQR:5-10).The predominant bacteria identified were Gram-positive cocci.CONCLUSION Applying enzymolysis gauze to cover the biopsy hole check valve significantly reduces bacterial aerosol contamination in endoscopy rooms during colonoscopy.展开更多
The dynamics differential equations are constructed, and the initial conditions are also given. Simulation shows the following conclusions: The water pressure in cylinder has great instantaneous pulsation and phase s...The dynamics differential equations are constructed, and the initial conditions are also given. Simulation shows the following conclusions: The water pressure in cylinder has great instantaneous pulsation and phase step when outlet valve or inlet valve opens, but is more gently in other time; The volume efficiency is influenced by the output pressure slightly, and decreases as the working rotational speed increases; When the inherent frequency of the valves is integer multiple of the working frequency, the volume efficiency of system will decrease evidently.展开更多
There are two kinds of piezoelectric pumps:check valve pumps and valve-less pumps.Whether to use a check valve or not depends upon the application occasion.To achieve large backpressure for higher flow rates,the pump ...There are two kinds of piezoelectric pumps:check valve pumps and valve-less pumps.Whether to use a check valve or not depends upon the application occasion.To achieve large backpressure for higher flow rates,the pump with check valve is desirable.However,adding check valves implies more complex structure and higher probability of valve blocking,etc.In order to solve the problem,effective driving and transport mechanics with compact construction and reliable service are being sought.In this paper,using the second-order longitudinal vibration mode of a bar-shaped piezoelectric vibrator for driving fluid,a piezoelectric pump is successfully made.The proposed piezoelectric pump consists of coaxial cylindrical shells and a bar-shaped piezoelectric vibrator,which has a disk part and a cone part.The lead zirconium titanate ceramic rings fixed in the vibrator are polarized along the thickness direction.When the second-order longitudinal vibration of the vibrator along its axis is excited,the disk part of the vibrator changes periodically the volume of the chamber and the cone part acts as a pin valve,driving the fluid from the inlet port to the outlet port.Finite elements analysis on the proposed pump model is carried out to verify its operation principle and design by the commercial FEM software ANSYS.Components of the piezoelectric pump were manufactured,assembled,and tested for flow rate and backpressure to validate the concepts of the proposed pump and confirm the simulation results of modal and harmonic analyses.The test results show that the performance of the proposed piezoelectric pump is about 910 mL/min in flow rate with a highest pressure level of 1.5 kPa under 400 V peak-to-peak voltage and 51.7 kHz operating frequency.It is confirmed that this bar-shaped piezoelectric transducer can be effectively applied in fluid transferring mechanism of pump through this research.展开更多
Butterfly check valves are widely used in water supply pipeline systems. Proper design of new valves requires accurate determination of the water impulse force and moment on the disk for transient flow conditions. The...Butterfly check valves are widely used in water supply pipeline systems. Proper design of new valves requires accurate determination of the water impulse force and moment on the disk for transient flow conditions. The impulse moments were measured using pressure measurement and strain gauge measurements. Correlation was developed relating the impulse moment to the velocity and angle that were used to design a new type of valves.展开更多
The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in othe...The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in other cities and countries.Wall electric fans can be installed in ventilation grills in kitchens,bathrooms,and toilets of apartments in multi-story residential buildings.Typically,these fans turn on with the light in the bathroom or toilet,so the problem is periodic.Forced airflow from a fan in one apartment disrupts the natural outflow of air in the ventilation system of a residential building designed and built according to building codes and regulations and can cause an unpleasant smell in neighboring apartments.In many cases,it is difficult to determine which apartments have fans and force the neighbors to remove them.Locally,on the scale of one apartment,the problem is solved by installing an air check valve in the ventilation grill,which will block the nuisance airflow from the ventilation system into the bathroom.Globally,the problem is solved by modification and subsequent compliance with building codes and regulations,the implementation of which is controlled by local authorities.展开更多
An air-supplement plasma synthetic jet(PSJ)actuator increases the air supplemental volume in the recovery stage and improves the jet energy by attaching a check valve to the chamber of a conventional actuator.To explo...An air-supplement plasma synthetic jet(PSJ)actuator increases the air supplemental volume in the recovery stage and improves the jet energy by attaching a check valve to the chamber of a conventional actuator.To explore the flow control effect and mechanism of the air-supplement actuator,via particle image velocimetry experiments in a low-speed wind tunnel,the flow field and boundary layer characteristics of a two-dimensional airfoil surface under different actuation states were compared for different attack angles and jet orifices.The experimental results show that,compared with the conventional actuation state,the jet energy of the air-supplement PSJ is higher and the indirect mixing effect of the counter-vortex sequence produced by the jet-mainstream interaction is stronger.Furthermore,the boundary layer mixing effect is better,which can further suppress flow separation and improve the critical flow separation attack angle.Moreover,increasing the jet momentum coefficient can enhance the flow control effect.The findings of this study could provide guidance for the flow control application of air-supplement PSJs.展开更多
基金Supported by the Construction Fund of Key Medical Disciplines of Hangzhou,No.2025HZGF05the Key R and D Program of Zhejiang Province,No.2023C03054 and No.2024C03048+1 种基金the Key Discipline of Integrated Chinese and Western Medicine(Digestive Diseases)in Zhejiang Province,No.2024-XK-61the Zhejiang Province Medical and Health Science and Technology Plan Project,No.2021KY848.
文摘BACKGROUND Bacterial contamination during colonoscopy is a significant concern,yet few studies have evaluated bacterial aerosols.This study aimed to determine whether covering the biopsy hole check valve with enzymolysis gauze(refers to sterile gauze soaked in a multi-enzyme cleaning solution)reduces bacterial air pollution in endoscopy rooms.AIM To evaluate the efficacy of an enzymolysis gauze cover in reducing bacterial aerosols from the biopsy valve.METHODS This prospective,single-blind trial included 80 patients undergoing elective diagnostic colonoscopy.During the procedure,the biopsy hole check valve was either covered or left uncovered with enzymolysis gauze.Air samples(100 L)were collected at a distance of 30 cm from the biopsy hole check valve and approximately 140 cm above the floor using a percussive air sampling instrument.Gram-positive bacteria were cultured on standard 90 mm colimycin nalidixic agar blood plates.The primary outcome measures were bacterial load and species identification.RESULTS Covering the biopsy hole check valve with enzymolysis gauze reduced bacterial load near the check valve from 50 colony-forming unit(CFU)/m^(3)[interquartile range(IQR):30-80]to 20 CFU/m^(3)(IQR:10-20).At the end of the procedure each day,covering the valve also decreased bacterial load in the endoscopy room from 35 CFU/m^(3)(IQR:33-85)to 10 CFU/m^(3)(IQR:5-10).The predominant bacteria identified were Gram-positive cocci.CONCLUSION Applying enzymolysis gauze to cover the biopsy hole check valve significantly reduces bacterial aerosol contamination in endoscopy rooms during colonoscopy.
基金This project is supported by National Natural Science Foundation of China(No.10342003).
文摘The dynamics differential equations are constructed, and the initial conditions are also given. Simulation shows the following conclusions: The water pressure in cylinder has great instantaneous pulsation and phase step when outlet valve or inlet valve opens, but is more gently in other time; The volume efficiency is influenced by the output pressure slightly, and decreases as the working rotational speed increases; When the inherent frequency of the valves is integer multiple of the working frequency, the volume efficiency of system will decrease evidently.
基金supported by National Basic Research Program (973 Program, Grant No. 2011CB707602)National Natural Science Foundation of China (Grant No. 10874090, Grant No. 91023020)National Natural Science Foundation of China Guangdong Joint Fund (Grant No. U0934004)
文摘There are two kinds of piezoelectric pumps:check valve pumps and valve-less pumps.Whether to use a check valve or not depends upon the application occasion.To achieve large backpressure for higher flow rates,the pump with check valve is desirable.However,adding check valves implies more complex structure and higher probability of valve blocking,etc.In order to solve the problem,effective driving and transport mechanics with compact construction and reliable service are being sought.In this paper,using the second-order longitudinal vibration mode of a bar-shaped piezoelectric vibrator for driving fluid,a piezoelectric pump is successfully made.The proposed piezoelectric pump consists of coaxial cylindrical shells and a bar-shaped piezoelectric vibrator,which has a disk part and a cone part.The lead zirconium titanate ceramic rings fixed in the vibrator are polarized along the thickness direction.When the second-order longitudinal vibration of the vibrator along its axis is excited,the disk part of the vibrator changes periodically the volume of the chamber and the cone part acts as a pin valve,driving the fluid from the inlet port to the outlet port.Finite elements analysis on the proposed pump model is carried out to verify its operation principle and design by the commercial FEM software ANSYS.Components of the piezoelectric pump were manufactured,assembled,and tested for flow rate and backpressure to validate the concepts of the proposed pump and confirm the simulation results of modal and harmonic analyses.The test results show that the performance of the proposed piezoelectric pump is about 910 mL/min in flow rate with a highest pressure level of 1.5 kPa under 400 V peak-to-peak voltage and 51.7 kHz operating frequency.It is confirmed that this bar-shaped piezoelectric transducer can be effectively applied in fluid transferring mechanism of pump through this research.
文摘Butterfly check valves are widely used in water supply pipeline systems. Proper design of new valves requires accurate determination of the water impulse force and moment on the disk for transient flow conditions. The impulse moments were measured using pressure measurement and strain gauge measurements. Correlation was developed relating the impulse moment to the velocity and angle that were used to design a new type of valves.
基金support from the Government of the Russian Federation (Mega grant No.075-15-2021-612 of June 4,2021) for funding scientific research in Russia.
文摘The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in other cities and countries.Wall electric fans can be installed in ventilation grills in kitchens,bathrooms,and toilets of apartments in multi-story residential buildings.Typically,these fans turn on with the light in the bathroom or toilet,so the problem is periodic.Forced airflow from a fan in one apartment disrupts the natural outflow of air in the ventilation system of a residential building designed and built according to building codes and regulations and can cause an unpleasant smell in neighboring apartments.In many cases,it is difficult to determine which apartments have fans and force the neighbors to remove them.Locally,on the scale of one apartment,the problem is solved by installing an air check valve in the ventilation grill,which will block the nuisance airflow from the ventilation system into the bathroom.Globally,the problem is solved by modification and subsequent compliance with building codes and regulations,the implementation of which is controlled by local authorities.
基金Fundamental Research Funds for the Central Universities of China(Grant no.20720210050)Natural Science Foundation of China(Grant no.51707169)+1 种基金Open Fund of Rotor Aerodynamics Key Laboratory,China Aerodynamics Research and Development Center(Grant no.RAL202103-1)Xiamen University Training Program of Innovation and Entrepreneurship for Undergraduates(Grant no.202110384082).
文摘An air-supplement plasma synthetic jet(PSJ)actuator increases the air supplemental volume in the recovery stage and improves the jet energy by attaching a check valve to the chamber of a conventional actuator.To explore the flow control effect and mechanism of the air-supplement actuator,via particle image velocimetry experiments in a low-speed wind tunnel,the flow field and boundary layer characteristics of a two-dimensional airfoil surface under different actuation states were compared for different attack angles and jet orifices.The experimental results show that,compared with the conventional actuation state,the jet energy of the air-supplement PSJ is higher and the indirect mixing effect of the counter-vortex sequence produced by the jet-mainstream interaction is stronger.Furthermore,the boundary layer mixing effect is better,which can further suppress flow separation and improve the critical flow separation attack angle.Moreover,increasing the jet momentum coefficient can enhance the flow control effect.The findings of this study could provide guidance for the flow control application of air-supplement PSJs.