BACKGROUND Hepatobiliary surgery is complex and requires a thorough understanding of the liver’s anatomy,biliary system,and vasculature.Traditional imaging methods such as computed tomography(CT)and magnetic resonanc...BACKGROUND Hepatobiliary surgery is complex and requires a thorough understanding of the liver’s anatomy,biliary system,and vasculature.Traditional imaging methods such as computed tomography(CT)and magnetic resonance imaging(MRI),although helpful,fail to provide three-dimensional(3D)relationships of these structures,which are critical for planning and executing complicated surgeries.AIM To explore the use of 3D imaging and virtual surgical planning(VSP)technologies to improve surgical accuracy,reduce complications,and enhance patient recovery in hepatobiliary surgeries.METHODS A comprehensive review of studies published between 2017 and 2024 was conducted through PubMed,Scopus,Google Scholar,and Web of Science.Studies selected focused on 3D imaging and VSP applications in hepatobiliary surgery,assessing surgical precision,complications,and patient outcomes.Thirty studies,including randomized controlled trials,cohort studies,and case reports,were included in the final analysis.RESULTS Various 3D imaging modalities,including multidetector CT,MRI,and 3D rotational angiography,provide high-resolution views of the liver’s vascular and biliary anatomy.VSP allows surgeons to simulate complex surgeries,improving preoperative planning and reducing complications like bleeding and bile leaks.Several studies have demonstrated improved surgical precision,reduced complications,and faster recovery times when 3D imaging and VSP were used in complex surgeries.CONCLUSION 3D imaging and VSP technologies significantly enhance the accuracy and outcomes of hepatobiliary surgeries by providing individualized preoperative planning.While promising,further research,particularly randomized controlled trials,is needed to standardize protocols and evaluate long-term efficacy.展开更多
Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention t...Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.展开更多
The anatomic relationship of oral and maxillofacial region is very com-plex,due to the large number of sinuses,cavities and spaces,and also closely related to the brain.The diagnosis of oral and maxillofacial lesions ...The anatomic relationship of oral and maxillofacial region is very com-plex,due to the large number of sinuses,cavities and spaces,and also closely related to the brain.The diagnosis of oral and maxillofacial lesions usually depends on the imaging examination.The conventional imaging methods are common CT and X-ray plain films.In recent years,with the rapid development of medical science and technology,more intuitive and vivid three-dimensional images have been applied in the diagnosis and treatment of oral and maxillofacial diseases.Therefore,CT three-dimensional imaging technology has been widely used in clinical practice.This paper reviews this topic.展开更多
A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method wit...A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method with scattering angle correction(CSS-BP-SC) can quickly perform the back-projection process of the Compton cone and can be used to precompute the list-mode maximum likelihood expectation maximization(LM-MLEM). A dedicated parallel architecture was designed for the graphics processing unit acceleration of the back-projection and iteration stage of the CSS-BP-SC-based LM-MLEM. The imaging results of the two-point source Monte Carlo(MC) simulation demonstrate that by analyzing the full width at half maximum along the three coordinate axes, the CSS-BP-SC-based LM-MLEM can obtain imaging results comparable to those of the traditional reconstruction algorithm, that is, the simple back-projection-based LM-MLEM. The imaging results of the mouse phantom MC simulation and experiment demonstrate that the reconstruction results obtained by the proposed method sufficiently coincide with the set radioactivity distribution, and the speed increased by more than 664 times compared to the traditional reconstruction algorithm in the mouse phantom experiment. The proposed method will further advance the imaging applications of Compton cameras.展开更多
Existing three-dimensional(3D) imaging technologies have issues such as requiring active illumination, multiple exposures, or coding modulation. We propose a passive single 3D imaging method based on an ordinary imagi...Existing three-dimensional(3D) imaging technologies have issues such as requiring active illumination, multiple exposures, or coding modulation. We propose a passive single 3D imaging method based on an ordinary imaging system.Using the point spread function of the imaging system to realize the non-coding measurement on the target, the full-focus images and depth information of the 3D target can be extracted from a single two-dimensional(2D) image through the compressed sensing algorithm. Simulation and experiments show that this approach can complete passive 3D imaging based on an ordinary imaging system without any coding operations. This method can achieve millimeter-level vertical resolution under single exposure conditions and has the potential for real-time dynamic 3D imaging. It improves the efficiency of 3D information detection, reduces the complexity of the imaging system, and may be of considerable value to the field of computer vision and other related applications.展开更多
The most common methods for three-dimensional reconstruction of peripheral nerve fascicles include histological and radiology techniques. Histological techniques have many drawbacks including an enormous manual worklo...The most common methods for three-dimensional reconstruction of peripheral nerve fascicles include histological and radiology techniques. Histological techniques have many drawbacks including an enormous manual workload and poor image registration. Micro-magnetic resonance imaging(Micro-MRI), an emerging radiology technique, has been used to report results in the brain, liver and tumor tissues. However, micro-MRI usage for obtaining intraneural structures has not been reported. The aim of this study was to present a new imaging method for three-dimensional reconstruction of peripheral nerve fascicles by ~1T micro-MRI. Freshly harvested sciatic nerve samples from an amputated limb were divided into four groups. Two different scanning conditions(Mannerist Solution/GD-DTPA contrast agent, distilled water) were selected, and both T1 and T2 phases programmed for each scanning condition. Three clinical surgeons evaluated the quality of the images via a standardized scale. Moreover, to analyze deformation of the two-dimensional image, the nerve diameter and total area of the micro-MRI images were compared after hematoxylin-eosin staining. The results show that rapid micro-MRI imaging method can be used for three-dimensional reconstruction of the fascicle structure. Nerve sample immersed in contrast agent(Mannerist Solution/GD-DTPA) and scanned in the T1 phase was the best. Moreover, the nerve sample was scanned freshly and can be recycled for other procedures. MRI images show better stability and smaller deformation compared with histological images. In conclusion, micro-MRI provides a feasible and rapid method for three-dimensional reconstruction of peripheral nerve fascicles, which can clearly show the internal structure of the peripheral nerve.展开更多
Objective: to investigate the nursing effect of continuous improvement of intestinal preparation (CQI) in three-dimensional intestinal CT imaging. Methods: a total of 60 patients who underwent intestinal three-dimensi...Objective: to investigate the nursing effect of continuous improvement of intestinal preparation (CQI) in three-dimensional intestinal CT imaging. Methods: a total of 60 patients who underwent intestinal three-dimensional CT examination in our hospital from January 2019 to January 2021 were selected and divided into two groups according to random number table method, with 30 patients in each group. The control group was given routine nursing intervention, and the observation group was given intestinal preparation continuous improvement intervention. The success rate of examination, awareness rate before examination, satisfaction rate of image quality and complications were compared between the two groups. Results: the success rate and awareness rate before examination in the observation group were higher than those in the control group, and the difference was statistically significant (P < 0.05). The satisfaction rate of image quality in the observation group was higher than that in the control group, and the incidence of complications in the observation group was lower than that in the control group, with statistical significance (P < 0.05). Conclusion: intestinal preparation CQI intervention can improve the success rate of intestinal three-dimensional CT examination, improve the knowledge of patients, enhance the quality of CT imaging, and reduce the incidence of complications.展开更多
In order to obtain a better sandstone three-dimensional (3D) reconstruction result which is more similar to the original sample, an algorithm based on stationarity for a two-dimensional (2D) training image is prop...In order to obtain a better sandstone three-dimensional (3D) reconstruction result which is more similar to the original sample, an algorithm based on stationarity for a two-dimensional (2D) training image is proposed. The second-order statistics based on texture features are analyzed to evaluate the scale stationarity of the training image. The multiple-point statistics of the training image are applied to obtain the multiple-point statistics stationarity estimation by the multi-point density function. The results show that the reconstructed 3D structures are closer to reality when the training image has better scale stationarity and multiple-point statistics stationarity by the indications of local percolation probability and two-point probability. Moreover, training images with higher multiple-point statistics stationarity and lower scale stationarity are likely to obtain closer results to the real 3D structure, and vice versa. Thus, stationarity analysis of the training image has far-reaching significance in choosing a better 2D thin section image for the 3D reconstruction of porous media. Especially, high-order statistics perform better than low-order statistics.展开更多
Background:Successful liver resection in oncologic surgery depends on safety,precision,and efficacy,all of which require a thorough understanding of liver anatomy.Contrast-enhanced computed tomography(CT)-generated th...Background:Successful liver resection in oncologic surgery depends on safety,precision,and efficacy,all of which require a thorough understanding of liver anatomy.Contrast-enhanced computed tomography(CT)-generated three-dimensional(3D)models have been proposed as a valuable tool to enhance this understanding.However,a systematic comparison of different display modalities across professional groups has not yet been performed.Methods:In this prospective,monocentric randomized trial,we compared high-resolution twodimensional(2D)CT images of liver malignancies with their corresponding standardized,non-colored 3D virtual and printed models in facilitating anatomical and spatial understanding as well as surgical decision-making.A total of 91 participants,including 40 surgeons,10 radiologists,and 41 students,evaluated six clinical cases(three centrally and three peripherally located liver malignancies).Each participant assessed one central and one peripheral case per display modality,presented in a random order.Results:Compared to 2D CT images,both 3D virtual and printed models significantly improved the identification of tumor location(P<0.001),enhanced the comprehension of spatial relationships with adjacent liver and portal veins(P<0.001 and P=0.019,respectively),and facilitated clinical decisionmaking(P<0.001).No significant difference was observed between virtual and printed models in terms of effectiveness.Within the different groups,surgeons and students,but not radiologists,more accurately identified tumor location and spatial relationships with adjacent liver and portal veins using 3D models.Subjectively,most surgeons and students preferred 3D printed models over virtual models and 2D CT images.Conclusions:This study demonstrated that standardized,non-colored 3D virtual and printed models equally help preoperative anatomical understanding and decision-making,particularly for surgeons and students.By isolating the influence of display modality,our findings clarify prior inconsistent results and support the integration of cost-effective 3D visualization by applying virtual models into surgical planning and education.Preference for printed models despite comparable efficacy highlights the importance of user-centered implementation strategies.展开更多
Spectral computed tomography(CT)imaging as an advanced and non-invasive technique is of importance in the diagnosis of disease.Therefore,it is significant to develop safe and high-performance contrast agents for spect...Spectral computed tomography(CT)imaging as an advanced and non-invasive technique is of importance in the diagnosis of disease.Therefore,it is significant to develop safe and high-performance contrast agents for spectral CT imaging.Herein,we synthesized a small-molecule erbium chelate(ErDOTA dimeglumine),with the advantages of favorable colloidal and structure stability,good biocompatibility and biosafety,and sensitive spectral CT imaging ability in vitro and in vivo.Erbium chelate exhibits strong X-ray attenuation capability and the energy-dependent attenuation in the range of 40-160 keV due to the high K-edge value of Er(57.5 keV).Especially,the slope of the Hounsfield unit(HU)curve for erbium chelate is 1.5 times that of iohexol at 50 keV,and 5.6 times that of iohexol at130 keV.We then applied erbium chelate in the in vivo spectral CT imaging of healthy mice and DSSinduced colitis mice.It is found that erbium chelate is rapidly metabolized from the intestinal tract in healthy mice within 12 h due to favorable biocompatibility,while it is enriched and displays brighter signals in the inflammatory site of colon in colitis mice.Specifically,the CT value in the large intestines of colitis mice 12 h after erbium chelate administration is 53.0,which is much higher than that of healthy mice(8.3),showing great potential for sensitive and accurate diagnosis of inflammatory bowel disease.Moreover,compared with the clinically used contrast agent iohexol,erbium chelate shows better spectral CT imaging performance in both healthy and colitis mice at low to high energy settings.Superior CT imaging is also observed in CT26 tumor-bearing mice after administration with erbium chelate in comparison to iohexol.In summary,the small-molecule erbium chelate is expected to be a safe and highperfo rmance co ntrast agent for spectral CT imaging to promote the diagnosis of gastrointestinal diseases.展开更多
BACKGROUND Photon-counting detector(PCD)CT represents a transformative advancement in radiological imaging,offering superior spatial resolution,enhanced contrast-tonoise ratio,and reduced radiation dose compared with ...BACKGROUND Photon-counting detector(PCD)CT represents a transformative advancement in radiological imaging,offering superior spatial resolution,enhanced contrast-tonoise ratio,and reduced radiation dose compared with the conventional energyintegrating detector CT.AIM To evaluate PCD CT in oncologic imaging,focusing on its role in tumor detection,staging,and treatment response assessment.METHODS We performed a systematic PubMed search from January 1,2017 to December 31,2024,using the keywords“photon-counting CT”,“cancer”,and“tumor”to identify studies on its use in oncologic imaging.We included experimental studies on humans or human phantoms and excluded reviews,commentaries,editorials,non-English,animal,and non-experimental studies.Study selection followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.Out of 175 initial studies,39 met the inclusion criteria after screening and full-text review.Data extraction focused on study type,country of origin,and oncologic applications of photon-counting CT.No formal risk of bias assessment was performed,and the review was not registered in PROSPERO as it did not include a meta-analysis.RESULTS Key findings highlighted the advantages of PCD CT in imaging renal masses,adrenal adenomas,ovarian cancer,breast cancer,prostate cancer,pancreatic tumors,hepatocellular carcinoma,metastases,multiple myeloma,and lung cancer.Additionally,PCD CT has demonstrated improved lesion characterization and enhanced diagnostic accuracy in oncology.Despite its promising capabilities challenges related to data processing,storage,and accessibility remain.CONCLUSION As PCD CT technology evolves,its integration into routine oncologic imaging has the potential to significantly enhance cancer diagnosis and patient management.展开更多
This study aims to explore the clinical and CT imaging features of brucellosis spondylitis(BS)and to strengthen the clinical cognition to reduce misdiagnosis and mistreatment.In this study,clinical and CT imaging data...This study aims to explore the clinical and CT imaging features of brucellosis spondylitis(BS)and to strengthen the clinical cognition to reduce misdiagnosis and mistreatment.In this study,clinical and CT imaging data of 106 patients with BS diagnosed in the Second Hospital of Hohhot and the Third Hospital of Baotou were collected from March 2023 to September 2024 and retrospectively analyzed by clinical manifestations,CT imaging,and disease regression.In 106 patients,58.5%had fever,98.1%had malaise,96.2%had excessive sweating,81.1%had lumbosacral pain,79.3%had limitation of limb movement,76.4%had constipation,and 6.6%had urinary retention.For imaging manifestations,the involvement of lumbar,thoracic and cervical vertebrae were 80.2%,16.9%and 1.9%,respectively.Lesions<1.0 cm,1.0–2.0 cm,2.0–3.0 cm,and>3.0 cm were found in 49.4%,29.6%,19.4%,and 1.6%,respectively.In 106 patients,CT showed round,irregular or worm-like areas of bone destruction,with coexisting osteophytes in 61.5%and no signs of dead bone or pedicle destruction.Interdiscal destruction,spinal canal abscess,ligament injury,and signs of lumbar major muscle compression were rare,accounting for 11.7%,6.6%,4.7%,and 3.8%,respectively.Regarding regression,106 patients with BS treated with antimicrobial therapy or antimicrobial+surgery had a good prognosis.In conclusion,BS has its own characteristics in clinical and imaging aspects and it is easy to distinguish from other common causes of spondylitis bone damage.展开更多
Artificial intelligence(AI)is rapidly transforming radiology and computed tomography(CT)imaging by enabling automated image analysis,improved diagnostic accuracy,and clinical decision-support.We performed a systematic...Artificial intelligence(AI)is rapidly transforming radiology and computed tomography(CT)imaging by enabling automated image analysis,improved diagnostic accuracy,and clinical decision-support.We performed a systematic review of peerreviewed studies published between January 1,2010 and March 31,2025 to quantify reported gains in diagnostic performance and workflow efficiency,to evaluate clinical decision-support benefits and risks,and to identify integration priorities.We searched PubMed,IEEE Xplore,Scopus,ScienceDirect,and Google Scholar and screened 128 records;26 studies met the inclusion criteria.Extracted data included study design,AI architecture,sample size,and quantitative performance metrics;study quality was assessed using Newcastle-Ottawa Scales(NOS),Cochrane RoB 2,or AMSTAR 2 as appropriate.Across included studies,AI applications in CT showed consistent improvements in sensitivity,specificity,and time-to-diagnosis in specific tasks(notably lung-nodule detection and intracranial hemorrhage triage),with reported detection-rate increases up to~20%and reduced turnaround times in several real-world implementations.Barriers include dataset bias,limited external validation,interpretability(“black-box”)concerns,workflow integration challenges,and evolving regulatory issues.Economic analyses suggest potentially favorable return on investment(ROI)in high-volume settings but are sensitive to licensing and infrastructure costs.To realize AI's benefits in CT imaging,rigorous multi-center validation,transparent reporting,humancentered workflow design,and post-deployment surveillance are essential.展开更多
Photodynamic therapy(PDT),as a non-invasive treatment,is expected to be widely used in clinical cancer treatment.In this paper,a near-infrared(NIR)light responsive Lu_(2)O_(3):Yb/Er/Li-Ce6@MIL-101/GOx-PDA(LCMGP)nanodi...Photodynamic therapy(PDT),as a non-invasive treatment,is expected to be widely used in clinical cancer treatment.In this paper,a near-infrared(NIR)light responsive Lu_(2)O_(3):Yb/Er/Li-Ce6@MIL-101/GOx-PDA(LCMGP)nanodiagnostic platform was prepared for CT/PA imaging-guided multimodality synergistic therapy.Under 808 nm laser irradiation,Lu_(2)O_(3):Yb/Er/Li-Ce6(LC)NPs in the nano-diagnostic platform are activated and sensitized by NIR light,resulting in the generation of more single-linear oxygen(^(1)O_(2))for efficient PDT.Glucose oxidase(GOx)and MIL-101(Fe)nanozymes can utilize their excellent enzyme cascade catalytic properties and peroxidase-like catalytic properties to undergo glycolysis reactions and catalyze the decomposition of endogenous hydrogen peroxide(H_(2)O_(2)),producing a large amount of hydroxyl radicals(·OH),achieving efficient chemodynamic therapy(CDT).The functionalized modification of polydopamine(PDA)endows the LCMGP nanoparticles with higher photothermal conversion efficiency,which can prompt high local temperature at the tumor site under the irradiation of NIR light to achieve efficient photothermal therapy(PTT).In addition,hyperthermia accelerates the catalytic efficiency of the nanozymatic cascade of LCMGP nanoparticles to enhance ROS production while increasing cellular uptake,resulting in PTT-induced PDT/CDT synergistic effect(96%).Based on the excellent photothermal conversion effect of PDA and the high X-ray atte nuation effect of Lu/Fe,the LCMGP nanotherapeutic system demonstrates good CT/PA imaging function,providing new insights and ideas for imaging-mediated multimodal synergistic therapy.展开更多
Perianal abscess is a common disease in anorectal surgery. If the diagnosis is not clear and the cure is thoroughly cleared, the recurrence and spread of anal fistula will cause life-long pain. Objective: To investiga...Perianal abscess is a common disease in anorectal surgery. If the diagnosis is not clear and the cure is thoroughly cleared, the recurrence and spread of anal fistula will cause life-long pain. Objective: To investigate the application of 3.0T MRI 3D CUBE T2WI lipid suppression sequence in the diagnosis of perianal abscess. Methods: Thirty-six patients with perianal abscess confirmed by operation were examined with 2D T2WI and 3D CUBE T2WI lipid suppression sequences before operation. Two imaging techniques were evaluated to show the types of perianal abscess, the number of abscesses, the number of internal orifices of abscess, and the number of fistula branches with anal fistula in abscess. Results: Among 36 cases of perianal abscess, there were 5 cases of anal subcutaneous abscess, 12 cases of ischiorectal space abscess (8 cases complicated with anal fistula), 6 cases of posterior anal space abscess, 5 cases of anal sphincter abscess (3 cases complicated with anal fistula), 2 cases of high intermuscular abscess, 2 cases of rectal submucosal abscess, 3 cases of complex abscess (3 cases complicated with anal fistula), 1 case of misdiagnosis, 2D T2WI lipid suppression sequence and 3D CUBE T2WI suppression. The accuracy of lipid sequence abscess typing was 80.6% (29/36) and 88.9% (32/36), respectively, with no significant difference (P > 0.05). Thirty-six patients were surgically diagnosed as having 32 internal orifices, 68.8% (22/32) and 93.8% (30/32) of 2D T2WI and 3D CUBE T2WI lipid-suppressing sequences, respectively, with significant difference (P Conclusion: 3D CUBE T2WI lipid suppression sequence is superior to 2D T2WI lipid suppression sequence in the classification of perianal abscess, the number of internal orifices of abscess and the number of fistula branches of abscess complicated with anal fistula. It can also determine the number of internal orifices of abscess complicated with anal fistula, the number of fistula branches, the shape of primary and branch fistula and the relationship among pelvic floor muscle tissues. It can provide more accurate images for preoperative and intraoperative clinical surgery.展开更多
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT...The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF.展开更多
Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween Septem...Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween September 2010 and April 2014, a prospective study was conducted in a single referral center using 3D-SU1S performed after 2D-US in 10 cases of sirenomelia. Diagnostic accuracy and detailed findings were compared with postnatal three-dimensional helical computed tomography (3D-HCT), radiological findings and autopsy. Pregnancy was terminated in all 10 sirenomelia cases, including 9 singletons and I conjoined twin pregnancy, for a total of 5 males and 5 females. These cases of sirenomelia were deter- mined by autopsy and/or chromosomal examination. Initial 2D-US showed that there were 10 cases of oligohydranmios, bilateral renal agenesis, bladder agenesis, single umbilical artery, fusion of the lower limbs and spinal abnormalities; 8 cases of dipus or monopus; 2 cases of apus; and 8 cases of cardiac abnormalities. Subsequent 3D-SUIS showed that there were 9 cases of scoliosis, l0 cases of sacrococ- cygeal vertebra dysplasia, 3 cases of hemivertebra, 1 case of vertebral fusion, 3 cases of spina bifida, and 5 cases of rib abnormalities. 3D-SUIS identified significantly more skeletal abnormalities than did 2D-US, and its accuracy was 79.5% (70/88) compared with 3D-HCT and radiography. 3D-SUIS seems to be a useful complementary method to 2D-US and may improve the accuracy of identifying prenatal skeletal abnormalities related to sirenomelia.展开更多
BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and H...BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and HFS caused by NVC. The judgement of NVC is a critical step in the preoperative evaluation of MVD, which is related to the effect of MVD treatment. Magnetic resonance imaging(MRI) technology has been used to detect NVC prior to MVD for several years. Among many MRI sequences, three-dimensional time-of-flight magnetic resonance angiography(3D TOF MRA) is the most widely used. However, 3D TOF MRA has some shortcomings in detecting NVC. Therefore, 3D TOF MRA combined with high resolution T2-weighted imaging(HR T2WI) is considered to be a more effective method to detect NVC.AIM To determine the value of 3D TOF MRA combined with HR T2WI in the judgment of NVC, and thus to assess its value in the preoperative evaluation of MVD.METHODS Related studies published from inception to September 2022 based on PubMed, Embase, Web of Science, and the Cochrane Library were retrieved. Studies that investigated 3D TOF MRA combined with HR T2WI to judge NVC in patients with TN or HFS were included according to the inclusion criteria. Studies without complete data or not relevant to the research topics were excluded. The Quality Assessment of Diagnostic Accuracy Studies checklist was used to assess the quality of included studies. The publication bias of the included literature was examined by Deeks’ test. An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize data. Data analysis was performed using the MIDAS module of statistical software Stata 16.0. Two independent investigators extracted patient and study characteristics, and discrepancies were resolved by consensus. Individual and pooled sensitivities and specificities were calculated. The I_(2) statistic and Q test were used to test heterogeneity. The study was registered on the website of PROSERO(registration No. CRD42022357158).RESULTS Our search identified 595 articles, of which 12(including 855 patients) fulfilled the inclusion criteria. Bivariate analysis showed that the pooled sensitivity and specificity of 3D TOF MRA combined with HR T2WI for detecting NVC were 0.96 [95% confidence interval(CI): 0.92-0.98] and 0.92(95%CI: 0.74-0.98), respectively. The pooled positive likelihood ratio was 12.4(95%CI: 3.2-47.8), pooled negative likelihood ratio was 0.04(95%CI: 0.02-0.09), and pooled diagnostic odds ratio was 283(95%CI: 50-1620). The area under the receiver operating characteristic curve was 0.98(95%CI: 0.97-0.99). The studies showed no substantial heterogeneity(I2 = 0, Q = 0.001 P = 0.50).CONCLUSION Our results suggest that 3D TOF MRA combined with HR T2WI has excellent sensitivity and specificity for judging NVC in patients with TN or HFS. This method can be used as an effective tool for preoperative evaluation of MVD.展开更多
A method and procedure is presented to reconstruct three-dimensional(3D) positions of scattering centers from multiple synthetic aperture radar(SAR) images. Firstly, two-dimensional(2D) attribute scattering centers of...A method and procedure is presented to reconstruct three-dimensional(3D) positions of scattering centers from multiple synthetic aperture radar(SAR) images. Firstly, two-dimensional(2D) attribute scattering centers of targets are extracted from 2D SAR images. Secondly, similarity measure is developed based on 2D attributed scatter centers' location, type, and radargrammetry principle between multiple SAR images. By this similarity, we can associate 2D scatter centers and then obtain candidate 3D scattering centers. Thirdly, these candidate scattering centers are clustered in 3D space to reconstruct final 3D positions. Compared with presented methods, the proposed method has a capability of describing distributed scattering center, reduces false and missing 3D scattering centers, and has fewer restrictionson modeling data. Finally, results of experiments have demonstrated the effectiveness of the proposed method.展开更多
Three-dimensional(3D)reconstruction of human organs has gained attention in recent years due to advances in the Internet and graphics processing units.In the coming years,most patient care will shift toward this new p...Three-dimensional(3D)reconstruction of human organs has gained attention in recent years due to advances in the Internet and graphics processing units.In the coming years,most patient care will shift toward this new paradigm.However,development of fast and accurate 3D models from medical images or a set of medical scans remains a daunting task due to the number of pre-processing steps involved,most of which are dependent on human expertise.In this review,a survey of pre-processing steps was conducted,and reconstruction techniques for several organs in medical diagnosis were studied.Various methods and principles related to 3D reconstruction were highlighted.The usefulness of 3D reconstruction of organs in medical diagnosis was also highlighted.展开更多
文摘BACKGROUND Hepatobiliary surgery is complex and requires a thorough understanding of the liver’s anatomy,biliary system,and vasculature.Traditional imaging methods such as computed tomography(CT)and magnetic resonance imaging(MRI),although helpful,fail to provide three-dimensional(3D)relationships of these structures,which are critical for planning and executing complicated surgeries.AIM To explore the use of 3D imaging and virtual surgical planning(VSP)technologies to improve surgical accuracy,reduce complications,and enhance patient recovery in hepatobiliary surgeries.METHODS A comprehensive review of studies published between 2017 and 2024 was conducted through PubMed,Scopus,Google Scholar,and Web of Science.Studies selected focused on 3D imaging and VSP applications in hepatobiliary surgery,assessing surgical precision,complications,and patient outcomes.Thirty studies,including randomized controlled trials,cohort studies,and case reports,were included in the final analysis.RESULTS Various 3D imaging modalities,including multidetector CT,MRI,and 3D rotational angiography,provide high-resolution views of the liver’s vascular and biliary anatomy.VSP allows surgeons to simulate complex surgeries,improving preoperative planning and reducing complications like bleeding and bile leaks.Several studies have demonstrated improved surgical precision,reduced complications,and faster recovery times when 3D imaging and VSP were used in complex surgeries.CONCLUSION 3D imaging and VSP technologies significantly enhance the accuracy and outcomes of hepatobiliary surgeries by providing individualized preoperative planning.While promising,further research,particularly randomized controlled trials,is needed to standardize protocols and evaluate long-term efficacy.
文摘Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.
文摘The anatomic relationship of oral and maxillofacial region is very com-plex,due to the large number of sinuses,cavities and spaces,and also closely related to the brain.The diagnosis of oral and maxillofacial lesions usually depends on the imaging examination.The conventional imaging methods are common CT and X-ray plain films.In recent years,with the rapid development of medical science and technology,more intuitive and vivid three-dimensional images have been applied in the diagnosis and treatment of oral and maxillofacial diseases.Therefore,CT three-dimensional imaging technology has been widely used in clinical practice.This paper reviews this topic.
基金supported by the National Natural Science Foundation of China (No. 12220101005)Natural Science Foundation of Jiangsu Province (No. BK20220132)+2 种基金Primary Research and Development Plan of Jiangsu Province (No. BE2019002-3)Fundamental Research Funds for Central Universities (No. NG2022004)the Foundation of the Graduate Innovation Center in NUAA (No. xcxjh20210613)。
文摘A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method with scattering angle correction(CSS-BP-SC) can quickly perform the back-projection process of the Compton cone and can be used to precompute the list-mode maximum likelihood expectation maximization(LM-MLEM). A dedicated parallel architecture was designed for the graphics processing unit acceleration of the back-projection and iteration stage of the CSS-BP-SC-based LM-MLEM. The imaging results of the two-point source Monte Carlo(MC) simulation demonstrate that by analyzing the full width at half maximum along the three coordinate axes, the CSS-BP-SC-based LM-MLEM can obtain imaging results comparable to those of the traditional reconstruction algorithm, that is, the simple back-projection-based LM-MLEM. The imaging results of the mouse phantom MC simulation and experiment demonstrate that the reconstruction results obtained by the proposed method sufficiently coincide with the set radioactivity distribution, and the speed increased by more than 664 times compared to the traditional reconstruction algorithm in the mouse phantom experiment. The proposed method will further advance the imaging applications of Compton cameras.
基金Project supported by the National Key Research and Development Program of China (Grant No. 2018YFB0504302)Beijing Institute of Technology Research Fund Program for Young Scholars (Grant No. 202122012)。
文摘Existing three-dimensional(3D) imaging technologies have issues such as requiring active illumination, multiple exposures, or coding modulation. We propose a passive single 3D imaging method based on an ordinary imaging system.Using the point spread function of the imaging system to realize the non-coding measurement on the target, the full-focus images and depth information of the 3D target can be extracted from a single two-dimensional(2D) image through the compressed sensing algorithm. Simulation and experiments show that this approach can complete passive 3D imaging based on an ordinary imaging system without any coding operations. This method can achieve millimeter-level vertical resolution under single exposure conditions and has the potential for real-time dynamic 3D imaging. It improves the efficiency of 3D information detection, reduces the complexity of the imaging system, and may be of considerable value to the field of computer vision and other related applications.
基金supported by grants from the National Key Research and Development Plan of China,No.31670986(to QTZ)the Science and Technology Project of Guangdong Province of China,No.2014B020227001,2017A050501017(to QTZ)the Science and Technology Project of Guangzhou of China,No.201807010082(to QTZ),201704030041(to JQ)
文摘The most common methods for three-dimensional reconstruction of peripheral nerve fascicles include histological and radiology techniques. Histological techniques have many drawbacks including an enormous manual workload and poor image registration. Micro-magnetic resonance imaging(Micro-MRI), an emerging radiology technique, has been used to report results in the brain, liver and tumor tissues. However, micro-MRI usage for obtaining intraneural structures has not been reported. The aim of this study was to present a new imaging method for three-dimensional reconstruction of peripheral nerve fascicles by ~1T micro-MRI. Freshly harvested sciatic nerve samples from an amputated limb were divided into four groups. Two different scanning conditions(Mannerist Solution/GD-DTPA contrast agent, distilled water) were selected, and both T1 and T2 phases programmed for each scanning condition. Three clinical surgeons evaluated the quality of the images via a standardized scale. Moreover, to analyze deformation of the two-dimensional image, the nerve diameter and total area of the micro-MRI images were compared after hematoxylin-eosin staining. The results show that rapid micro-MRI imaging method can be used for three-dimensional reconstruction of the fascicle structure. Nerve sample immersed in contrast agent(Mannerist Solution/GD-DTPA) and scanned in the T1 phase was the best. Moreover, the nerve sample was scanned freshly and can be recycled for other procedures. MRI images show better stability and smaller deformation compared with histological images. In conclusion, micro-MRI provides a feasible and rapid method for three-dimensional reconstruction of peripheral nerve fascicles, which can clearly show the internal structure of the peripheral nerve.
文摘Objective: to investigate the nursing effect of continuous improvement of intestinal preparation (CQI) in three-dimensional intestinal CT imaging. Methods: a total of 60 patients who underwent intestinal three-dimensional CT examination in our hospital from January 2019 to January 2021 were selected and divided into two groups according to random number table method, with 30 patients in each group. The control group was given routine nursing intervention, and the observation group was given intestinal preparation continuous improvement intervention. The success rate of examination, awareness rate before examination, satisfaction rate of image quality and complications were compared between the two groups. Results: the success rate and awareness rate before examination in the observation group were higher than those in the control group, and the difference was statistically significant (P < 0.05). The satisfaction rate of image quality in the observation group was higher than that in the control group, and the incidence of complications in the observation group was lower than that in the control group, with statistical significance (P < 0.05). Conclusion: intestinal preparation CQI intervention can improve the success rate of intestinal three-dimensional CT examination, improve the knowledge of patients, enhance the quality of CT imaging, and reduce the incidence of complications.
基金The National Natural Science Foundation of China(No.60972130)
文摘In order to obtain a better sandstone three-dimensional (3D) reconstruction result which is more similar to the original sample, an algorithm based on stationarity for a two-dimensional (2D) training image is proposed. The second-order statistics based on texture features are analyzed to evaluate the scale stationarity of the training image. The multiple-point statistics of the training image are applied to obtain the multiple-point statistics stationarity estimation by the multi-point density function. The results show that the reconstructed 3D structures are closer to reality when the training image has better scale stationarity and multiple-point statistics stationarity by the indications of local percolation probability and two-point probability. Moreover, training images with higher multiple-point statistics stationarity and lower scale stationarity are likely to obtain closer results to the real 3D structure, and vice versa. Thus, stationarity analysis of the training image has far-reaching significance in choosing a better 2D thin section image for the 3D reconstruction of porous media. Especially, high-order statistics perform better than low-order statistics.
文摘Background:Successful liver resection in oncologic surgery depends on safety,precision,and efficacy,all of which require a thorough understanding of liver anatomy.Contrast-enhanced computed tomography(CT)-generated three-dimensional(3D)models have been proposed as a valuable tool to enhance this understanding.However,a systematic comparison of different display modalities across professional groups has not yet been performed.Methods:In this prospective,monocentric randomized trial,we compared high-resolution twodimensional(2D)CT images of liver malignancies with their corresponding standardized,non-colored 3D virtual and printed models in facilitating anatomical and spatial understanding as well as surgical decision-making.A total of 91 participants,including 40 surgeons,10 radiologists,and 41 students,evaluated six clinical cases(three centrally and three peripherally located liver malignancies).Each participant assessed one central and one peripheral case per display modality,presented in a random order.Results:Compared to 2D CT images,both 3D virtual and printed models significantly improved the identification of tumor location(P<0.001),enhanced the comprehension of spatial relationships with adjacent liver and portal veins(P<0.001 and P=0.019,respectively),and facilitated clinical decisionmaking(P<0.001).No significant difference was observed between virtual and printed models in terms of effectiveness.Within the different groups,surgeons and students,but not radiologists,more accurately identified tumor location and spatial relationships with adjacent liver and portal veins using 3D models.Subjectively,most surgeons and students preferred 3D printed models over virtual models and 2D CT images.Conclusions:This study demonstrated that standardized,non-colored 3D virtual and printed models equally help preoperative anatomical understanding and decision-making,particularly for surgeons and students.By isolating the influence of display modality,our findings clarify prior inconsistent results and support the integration of cost-effective 3D visualization by applying virtual models into surgical planning and education.Preference for printed models despite comparable efficacy highlights the importance of user-centered implementation strategies.
基金Project supported by the National Natural Science Foundation of China(82304311,81903460)the Sichuan Province Science and Technology Program(2022YFS0616)。
文摘Spectral computed tomography(CT)imaging as an advanced and non-invasive technique is of importance in the diagnosis of disease.Therefore,it is significant to develop safe and high-performance contrast agents for spectral CT imaging.Herein,we synthesized a small-molecule erbium chelate(ErDOTA dimeglumine),with the advantages of favorable colloidal and structure stability,good biocompatibility and biosafety,and sensitive spectral CT imaging ability in vitro and in vivo.Erbium chelate exhibits strong X-ray attenuation capability and the energy-dependent attenuation in the range of 40-160 keV due to the high K-edge value of Er(57.5 keV).Especially,the slope of the Hounsfield unit(HU)curve for erbium chelate is 1.5 times that of iohexol at 50 keV,and 5.6 times that of iohexol at130 keV.We then applied erbium chelate in the in vivo spectral CT imaging of healthy mice and DSSinduced colitis mice.It is found that erbium chelate is rapidly metabolized from the intestinal tract in healthy mice within 12 h due to favorable biocompatibility,while it is enriched and displays brighter signals in the inflammatory site of colon in colitis mice.Specifically,the CT value in the large intestines of colitis mice 12 h after erbium chelate administration is 53.0,which is much higher than that of healthy mice(8.3),showing great potential for sensitive and accurate diagnosis of inflammatory bowel disease.Moreover,compared with the clinically used contrast agent iohexol,erbium chelate shows better spectral CT imaging performance in both healthy and colitis mice at low to high energy settings.Superior CT imaging is also observed in CT26 tumor-bearing mice after administration with erbium chelate in comparison to iohexol.In summary,the small-molecule erbium chelate is expected to be a safe and highperfo rmance co ntrast agent for spectral CT imaging to promote the diagnosis of gastrointestinal diseases.
文摘BACKGROUND Photon-counting detector(PCD)CT represents a transformative advancement in radiological imaging,offering superior spatial resolution,enhanced contrast-tonoise ratio,and reduced radiation dose compared with the conventional energyintegrating detector CT.AIM To evaluate PCD CT in oncologic imaging,focusing on its role in tumor detection,staging,and treatment response assessment.METHODS We performed a systematic PubMed search from January 1,2017 to December 31,2024,using the keywords“photon-counting CT”,“cancer”,and“tumor”to identify studies on its use in oncologic imaging.We included experimental studies on humans or human phantoms and excluded reviews,commentaries,editorials,non-English,animal,and non-experimental studies.Study selection followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.Out of 175 initial studies,39 met the inclusion criteria after screening and full-text review.Data extraction focused on study type,country of origin,and oncologic applications of photon-counting CT.No formal risk of bias assessment was performed,and the review was not registered in PROSPERO as it did not include a meta-analysis.RESULTS Key findings highlighted the advantages of PCD CT in imaging renal masses,adrenal adenomas,ovarian cancer,breast cancer,prostate cancer,pancreatic tumors,hepatocellular carcinoma,metastases,multiple myeloma,and lung cancer.Additionally,PCD CT has demonstrated improved lesion characterization and enhanced diagnostic accuracy in oncology.Despite its promising capabilities challenges related to data processing,storage,and accessibility remain.CONCLUSION As PCD CT technology evolves,its integration into routine oncologic imaging has the potential to significantly enhance cancer diagnosis and patient management.
文摘This study aims to explore the clinical and CT imaging features of brucellosis spondylitis(BS)and to strengthen the clinical cognition to reduce misdiagnosis and mistreatment.In this study,clinical and CT imaging data of 106 patients with BS diagnosed in the Second Hospital of Hohhot and the Third Hospital of Baotou were collected from March 2023 to September 2024 and retrospectively analyzed by clinical manifestations,CT imaging,and disease regression.In 106 patients,58.5%had fever,98.1%had malaise,96.2%had excessive sweating,81.1%had lumbosacral pain,79.3%had limitation of limb movement,76.4%had constipation,and 6.6%had urinary retention.For imaging manifestations,the involvement of lumbar,thoracic and cervical vertebrae were 80.2%,16.9%and 1.9%,respectively.Lesions<1.0 cm,1.0–2.0 cm,2.0–3.0 cm,and>3.0 cm were found in 49.4%,29.6%,19.4%,and 1.6%,respectively.In 106 patients,CT showed round,irregular or worm-like areas of bone destruction,with coexisting osteophytes in 61.5%and no signs of dead bone or pedicle destruction.Interdiscal destruction,spinal canal abscess,ligament injury,and signs of lumbar major muscle compression were rare,accounting for 11.7%,6.6%,4.7%,and 3.8%,respectively.Regarding regression,106 patients with BS treated with antimicrobial therapy or antimicrobial+surgery had a good prognosis.In conclusion,BS has its own characteristics in clinical and imaging aspects and it is easy to distinguish from other common causes of spondylitis bone damage.
文摘Artificial intelligence(AI)is rapidly transforming radiology and computed tomography(CT)imaging by enabling automated image analysis,improved diagnostic accuracy,and clinical decision-support.We performed a systematic review of peerreviewed studies published between January 1,2010 and March 31,2025 to quantify reported gains in diagnostic performance and workflow efficiency,to evaluate clinical decision-support benefits and risks,and to identify integration priorities.We searched PubMed,IEEE Xplore,Scopus,ScienceDirect,and Google Scholar and screened 128 records;26 studies met the inclusion criteria.Extracted data included study design,AI architecture,sample size,and quantitative performance metrics;study quality was assessed using Newcastle-Ottawa Scales(NOS),Cochrane RoB 2,or AMSTAR 2 as appropriate.Across included studies,AI applications in CT showed consistent improvements in sensitivity,specificity,and time-to-diagnosis in specific tasks(notably lung-nodule detection and intracranial hemorrhage triage),with reported detection-rate increases up to~20%and reduced turnaround times in several real-world implementations.Barriers include dataset bias,limited external validation,interpretability(“black-box”)concerns,workflow integration challenges,and evolving regulatory issues.Economic analyses suggest potentially favorable return on investment(ROI)in high-volume settings but are sensitive to licensing and infrastructure costs.To realize AI's benefits in CT imaging,rigorous multi-center validation,transparent reporting,humancentered workflow design,and post-deployment surveillance are essential.
基金Project supported by the Natural Science Foundation of Shandong Province(ZR2020ME045,ZR2020ME046)the Taishan Scholar Project of Shandong Province(tsqn201812130)+2 种基金the National Natural Science Foundation of China(82272833)"New Universities 20"Foundation of Jinan(2021GXRC099,T202204)China Postdoctoral Science Foundation(2022M711438)。
文摘Photodynamic therapy(PDT),as a non-invasive treatment,is expected to be widely used in clinical cancer treatment.In this paper,a near-infrared(NIR)light responsive Lu_(2)O_(3):Yb/Er/Li-Ce6@MIL-101/GOx-PDA(LCMGP)nanodiagnostic platform was prepared for CT/PA imaging-guided multimodality synergistic therapy.Under 808 nm laser irradiation,Lu_(2)O_(3):Yb/Er/Li-Ce6(LC)NPs in the nano-diagnostic platform are activated and sensitized by NIR light,resulting in the generation of more single-linear oxygen(^(1)O_(2))for efficient PDT.Glucose oxidase(GOx)and MIL-101(Fe)nanozymes can utilize their excellent enzyme cascade catalytic properties and peroxidase-like catalytic properties to undergo glycolysis reactions and catalyze the decomposition of endogenous hydrogen peroxide(H_(2)O_(2)),producing a large amount of hydroxyl radicals(·OH),achieving efficient chemodynamic therapy(CDT).The functionalized modification of polydopamine(PDA)endows the LCMGP nanoparticles with higher photothermal conversion efficiency,which can prompt high local temperature at the tumor site under the irradiation of NIR light to achieve efficient photothermal therapy(PTT).In addition,hyperthermia accelerates the catalytic efficiency of the nanozymatic cascade of LCMGP nanoparticles to enhance ROS production while increasing cellular uptake,resulting in PTT-induced PDT/CDT synergistic effect(96%).Based on the excellent photothermal conversion effect of PDA and the high X-ray atte nuation effect of Lu/Fe,the LCMGP nanotherapeutic system demonstrates good CT/PA imaging function,providing new insights and ideas for imaging-mediated multimodal synergistic therapy.
文摘Perianal abscess is a common disease in anorectal surgery. If the diagnosis is not clear and the cure is thoroughly cleared, the recurrence and spread of anal fistula will cause life-long pain. Objective: To investigate the application of 3.0T MRI 3D CUBE T2WI lipid suppression sequence in the diagnosis of perianal abscess. Methods: Thirty-six patients with perianal abscess confirmed by operation were examined with 2D T2WI and 3D CUBE T2WI lipid suppression sequences before operation. Two imaging techniques were evaluated to show the types of perianal abscess, the number of abscesses, the number of internal orifices of abscess, and the number of fistula branches with anal fistula in abscess. Results: Among 36 cases of perianal abscess, there were 5 cases of anal subcutaneous abscess, 12 cases of ischiorectal space abscess (8 cases complicated with anal fistula), 6 cases of posterior anal space abscess, 5 cases of anal sphincter abscess (3 cases complicated with anal fistula), 2 cases of high intermuscular abscess, 2 cases of rectal submucosal abscess, 3 cases of complex abscess (3 cases complicated with anal fistula), 1 case of misdiagnosis, 2D T2WI lipid suppression sequence and 3D CUBE T2WI suppression. The accuracy of lipid sequence abscess typing was 80.6% (29/36) and 88.9% (32/36), respectively, with no significant difference (P > 0.05). Thirty-six patients were surgically diagnosed as having 32 internal orifices, 68.8% (22/32) and 93.8% (30/32) of 2D T2WI and 3D CUBE T2WI lipid-suppressing sequences, respectively, with significant difference (P Conclusion: 3D CUBE T2WI lipid suppression sequence is superior to 2D T2WI lipid suppression sequence in the classification of perianal abscess, the number of internal orifices of abscess and the number of fistula branches of abscess complicated with anal fistula. It can also determine the number of internal orifices of abscess complicated with anal fistula, the number of fistula branches, the shape of primary and branch fistula and the relationship among pelvic floor muscle tissues. It can provide more accurate images for preoperative and intraoperative clinical surgery.
文摘The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF.
文摘Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween September 2010 and April 2014, a prospective study was conducted in a single referral center using 3D-SU1S performed after 2D-US in 10 cases of sirenomelia. Diagnostic accuracy and detailed findings were compared with postnatal three-dimensional helical computed tomography (3D-HCT), radiological findings and autopsy. Pregnancy was terminated in all 10 sirenomelia cases, including 9 singletons and I conjoined twin pregnancy, for a total of 5 males and 5 females. These cases of sirenomelia were deter- mined by autopsy and/or chromosomal examination. Initial 2D-US showed that there were 10 cases of oligohydranmios, bilateral renal agenesis, bladder agenesis, single umbilical artery, fusion of the lower limbs and spinal abnormalities; 8 cases of dipus or monopus; 2 cases of apus; and 8 cases of cardiac abnormalities. Subsequent 3D-SUIS showed that there were 9 cases of scoliosis, l0 cases of sacrococ- cygeal vertebra dysplasia, 3 cases of hemivertebra, 1 case of vertebral fusion, 3 cases of spina bifida, and 5 cases of rib abnormalities. 3D-SUIS identified significantly more skeletal abnormalities than did 2D-US, and its accuracy was 79.5% (70/88) compared with 3D-HCT and radiography. 3D-SUIS seems to be a useful complementary method to 2D-US and may improve the accuracy of identifying prenatal skeletal abnormalities related to sirenomelia.
基金Supported by the Key Research and Development Plan of Shaanxi Province,No.2021SF-298.
文摘BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and HFS caused by NVC. The judgement of NVC is a critical step in the preoperative evaluation of MVD, which is related to the effect of MVD treatment. Magnetic resonance imaging(MRI) technology has been used to detect NVC prior to MVD for several years. Among many MRI sequences, three-dimensional time-of-flight magnetic resonance angiography(3D TOF MRA) is the most widely used. However, 3D TOF MRA has some shortcomings in detecting NVC. Therefore, 3D TOF MRA combined with high resolution T2-weighted imaging(HR T2WI) is considered to be a more effective method to detect NVC.AIM To determine the value of 3D TOF MRA combined with HR T2WI in the judgment of NVC, and thus to assess its value in the preoperative evaluation of MVD.METHODS Related studies published from inception to September 2022 based on PubMed, Embase, Web of Science, and the Cochrane Library were retrieved. Studies that investigated 3D TOF MRA combined with HR T2WI to judge NVC in patients with TN or HFS were included according to the inclusion criteria. Studies without complete data or not relevant to the research topics were excluded. The Quality Assessment of Diagnostic Accuracy Studies checklist was used to assess the quality of included studies. The publication bias of the included literature was examined by Deeks’ test. An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize data. Data analysis was performed using the MIDAS module of statistical software Stata 16.0. Two independent investigators extracted patient and study characteristics, and discrepancies were resolved by consensus. Individual and pooled sensitivities and specificities were calculated. The I_(2) statistic and Q test were used to test heterogeneity. The study was registered on the website of PROSERO(registration No. CRD42022357158).RESULTS Our search identified 595 articles, of which 12(including 855 patients) fulfilled the inclusion criteria. Bivariate analysis showed that the pooled sensitivity and specificity of 3D TOF MRA combined with HR T2WI for detecting NVC were 0.96 [95% confidence interval(CI): 0.92-0.98] and 0.92(95%CI: 0.74-0.98), respectively. The pooled positive likelihood ratio was 12.4(95%CI: 3.2-47.8), pooled negative likelihood ratio was 0.04(95%CI: 0.02-0.09), and pooled diagnostic odds ratio was 283(95%CI: 50-1620). The area under the receiver operating characteristic curve was 0.98(95%CI: 0.97-0.99). The studies showed no substantial heterogeneity(I2 = 0, Q = 0.001 P = 0.50).CONCLUSION Our results suggest that 3D TOF MRA combined with HR T2WI has excellent sensitivity and specificity for judging NVC in patients with TN or HFS. This method can be used as an effective tool for preoperative evaluation of MVD.
文摘A method and procedure is presented to reconstruct three-dimensional(3D) positions of scattering centers from multiple synthetic aperture radar(SAR) images. Firstly, two-dimensional(2D) attribute scattering centers of targets are extracted from 2D SAR images. Secondly, similarity measure is developed based on 2D attributed scatter centers' location, type, and radargrammetry principle between multiple SAR images. By this similarity, we can associate 2D scatter centers and then obtain candidate 3D scattering centers. Thirdly, these candidate scattering centers are clustered in 3D space to reconstruct final 3D positions. Compared with presented methods, the proposed method has a capability of describing distributed scattering center, reduces false and missing 3D scattering centers, and has fewer restrictionson modeling data. Finally, results of experiments have demonstrated the effectiveness of the proposed method.
文摘Three-dimensional(3D)reconstruction of human organs has gained attention in recent years due to advances in the Internet and graphics processing units.In the coming years,most patient care will shift toward this new paradigm.However,development of fast and accurate 3D models from medical images or a set of medical scans remains a daunting task due to the number of pre-processing steps involved,most of which are dependent on human expertise.In this review,a survey of pre-processing steps was conducted,and reconstruction techniques for several organs in medical diagnosis were studied.Various methods and principles related to 3D reconstruction were highlighted.The usefulness of 3D reconstruction of organs in medical diagnosis was also highlighted.