Spine-related disorders are caused by several factors including (1) spinal nerve/visceral nerve stimulation by perivertebral aseptic inflammation, (2) spinal nerve/visceral nerve compression by injured periverterb...Spine-related disorders are caused by several factors including (1) spinal nerve/visceral nerve stimulation by perivertebral aseptic inflammation, (2) spinal nerve/visceral nerve compression by injured periverterbal soft tissue, dislocated perivertebral small joint, and proliferative/degenerative tissue and, (3) secondary damage to the spinal cord, peripheral nerve, vessels and autonomic nerve, which further stimulate nerve root sheath and surround- ing pain-carrying nerve fibers. In many cases, the source of pain cannot be detected by standard image modalities. Particularly in anatomically complex regions like the spine, SPECT/CT can be helpful for some aspects by intro- ducing a metabolical dimension to the classical way of morphology-based diagnostic. The aim of the present review was to give an overview of the adoption of SPECT/CT in a clinical spine-focused setting.展开更多
To explore the value of helical CT volume rendering technique (VRT) in post-operative evaluation of screw fixation of axis fractures.Methods There were 21 cases of screw fixation of axis fractures between February 200...To explore the value of helical CT volume rendering technique (VRT) in post-operative evaluation of screw fixation of axis fractures.Methods There were 21 cases of screw fixation of axis fractures between February 2002 and May 2004 in the study including six cases with fractures on axis body,five on odontoid process and 10 on axis body and odontoid process.All cases received X-ray plain film,helical CT scanning,multi-planar reformatting(MPR) and VRT.Results Screw fixation through axis body and massa lateralis atlantis was performed in 10 cases and that through axis body and odontoid process in 11.VRT could clearly display full aperture of screw orbit,location of screw and angle of fixation and hence was superior to X-ray plain film and MPR.Multi-angle VRT displayed asymmetrical space of odontoid process and massa lateralis atlantis in four cases and medial deviation of 2~5 mm of half screw in screw fixation through axis body and massa lateralis atlantis in six.Conclusion VRT can eliminate false shadow of fixation screw,clearly display full aperture of screw orbit and hence supply improtant imaging evidence for post-operative evaluation of screw fixation of axis fractures.7 refs,1 fig,1 tab.展开更多
Objective To evaluate the value of renal parenchymal volume and thickness by non-contrast spiral CT in evaluating the differential glomerular filtration rate ( GFR) for chronic obstructed kidneys,and to compare the co...Objective To evaluate the value of renal parenchymal volume and thickness by non-contrast spiral CT in evaluating the differential glomerular filtration rate ( GFR) for chronic obstructed kidneys,and to compare the correlations between two morphologic indices of renal parenchyma and GFR for chronic obstructed kidneys.展开更多
文摘Spine-related disorders are caused by several factors including (1) spinal nerve/visceral nerve stimulation by perivertebral aseptic inflammation, (2) spinal nerve/visceral nerve compression by injured periverterbal soft tissue, dislocated perivertebral small joint, and proliferative/degenerative tissue and, (3) secondary damage to the spinal cord, peripheral nerve, vessels and autonomic nerve, which further stimulate nerve root sheath and surround- ing pain-carrying nerve fibers. In many cases, the source of pain cannot be detected by standard image modalities. Particularly in anatomically complex regions like the spine, SPECT/CT can be helpful for some aspects by intro- ducing a metabolical dimension to the classical way of morphology-based diagnostic. The aim of the present review was to give an overview of the adoption of SPECT/CT in a clinical spine-focused setting.
文摘To explore the value of helical CT volume rendering technique (VRT) in post-operative evaluation of screw fixation of axis fractures.Methods There were 21 cases of screw fixation of axis fractures between February 2002 and May 2004 in the study including six cases with fractures on axis body,five on odontoid process and 10 on axis body and odontoid process.All cases received X-ray plain film,helical CT scanning,multi-planar reformatting(MPR) and VRT.Results Screw fixation through axis body and massa lateralis atlantis was performed in 10 cases and that through axis body and odontoid process in 11.VRT could clearly display full aperture of screw orbit,location of screw and angle of fixation and hence was superior to X-ray plain film and MPR.Multi-angle VRT displayed asymmetrical space of odontoid process and massa lateralis atlantis in four cases and medial deviation of 2~5 mm of half screw in screw fixation through axis body and massa lateralis atlantis in six.Conclusion VRT can eliminate false shadow of fixation screw,clearly display full aperture of screw orbit and hence supply improtant imaging evidence for post-operative evaluation of screw fixation of axis fractures.7 refs,1 fig,1 tab.
文摘Objective To evaluate the value of renal parenchymal volume and thickness by non-contrast spiral CT in evaluating the differential glomerular filtration rate ( GFR) for chronic obstructed kidneys,and to compare the correlations between two morphologic indices of renal parenchyma and GFR for chronic obstructed kidneys.