期刊文献+
共找到4,747篇文章
< 1 2 238 >
每页显示 20 50 100
Deep-Learning-Coupled Numerical Optimization Method for Designing Geometric Structure and Insertion-Withdrawal Force of Press-Fit Connector
1
作者 Mingzhi Wang Bingyu Hou Weidong Wang 《Acta Mechanica Solida Sinica》 2025年第1期78-90,共13页
The press-fit connector is a typical plug-and-play solderless connection,and it is widely used in signal transmission in fields such as communication and automotive devices.This paper focuses on inverse designing and ... The press-fit connector is a typical plug-and-play solderless connection,and it is widely used in signal transmission in fields such as communication and automotive devices.This paper focuses on inverse designing and optimization of geometric structure,as well as insertion-withdrawal forces of press-fit connector using artificial neural network(ANN)-assisted optimization method.The ANN model is established to approximate the relationship between geometric parameters and insertion-withdrawal forces,of which hyper-parameters of neural network are optimized to improve model performance.Two numerical methods are proposed for inverse designing structural parameters(Model-I)and multi-objective optimization of insertion-withdrawal forces(Model-II)of press-fit connector.In Model-I,a method for inverse designing structure parameters is established,of which an ANN model is coupled with single-objective optimization algorithm.The objective function is established,the inverse problem is solved,and effectiveness is verified.In Model-II,a multi-objective optimization method is proposed,of which an ANN model is coupled with genetic algorithm.The Pareto solution sets of insertion-withdrawal forces are obtained,and results are analyzed.The established ANN-coupled numerical optimization methods are beneficial for improving the design efficiency,and enhancing the connection reliability of the press-fit connector. 展开更多
关键词 Press-fit connector Compliant pin Insertion-withdrawal force Optimization design Neural network model
原文传递
基于ArcIMS Java Connector与Ajax技术构建林业WebGIS
2
作者 冯仲科 祝晓轶 +2 位作者 李亚东 聂敏莉 隋宏大 《北京林业大学学报》 CAS CSCD 北大核心 2008年第S1期11-14,共4页
该文为了解决在林业WebGIS开发中大数据量的服务器端实时验证和提高用户体验,通过将Ajax技术与ArcIMS Java Connector相结合的方法,实现了林业WebGIS的大数据的服务器实时验证、记录的无刷新分页显示、无刷新的地图操作、可拖拽UI界面... 该文为了解决在林业WebGIS开发中大数据量的服务器端实时验证和提高用户体验,通过将Ajax技术与ArcIMS Java Connector相结合的方法,实现了林业WebGIS的大数据的服务器实时验证、记录的无刷新分页显示、无刷新的地图操作、可拖拽UI界面等传统方式所无法实现的功能。在林业WebGIS上实现了将两种技术成功集成的例子。 展开更多
关键词 ARCIMS JAVA connector AJAX WEBGIS
在线阅读 下载PDF
Accelerated Degradation Reliability Modeling and Test Data Statistical Analysis of Aerospace Electrical Connector 被引量:21
3
作者 CHEN Wenhua LIU Juan +2 位作者 GAO Liang PAN Jun ZHOU Shengjun 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第6期957-962,共6页
As few or no failures occur during accelerated life test,it is difficult to assess reliability for long-life products with traditional life tests.Reliability assessment using degradation data of product performance ov... As few or no failures occur during accelerated life test,it is difficult to assess reliability for long-life products with traditional life tests.Reliability assessment using degradation data of product performance over time becomes a significant approach.Aerospace electrical connector is researched in this paper.Through the analysis of failure mechanism,the performance degradation law is obtained and the statistical model for degradation failure is set up; according to the research on statistical analysis methods for degradation data,accelerated life test theory and method for aerospace electrical connector based on performance degradation is proposed by improving time series analysis method,and the storage reliability is assessed for Y11X series of aerospace electrical connector with degradation data from accelerated degradation test.The result obtained is basically consistent with that obtained from accelerated life test based on failure data,and the two estimates of product's characteristic life only have a difference of 8.7%,but the test time shortens about a half.As a result,a systemic approach is proposed for reliability assessment of highly reliable and long-life aerospace product. 展开更多
关键词 electrical connector performance degradation RELIABILITY accelerated degradation test
在线阅读 下载PDF
应用ArcIMS Java connector制作动态专题图 被引量:7
4
作者 马金锋 潘瑜春 +1 位作者 郭占军 王纪华 《计算机应用研究》 CSCD 北大核心 2008年第5期1485-1488,共4页
提出一种Java connector方式制作动态专题图,并与ArcIMS制作动态专题图的另一种方式即定制开发ArcXML方式作了对比。前者直接编辑ArcXML文件,操作过程复杂、不易扩展,难以达到动态制作的目的;后者实现了ArcXML到Java对象的映射,支持面... 提出一种Java connector方式制作动态专题图,并与ArcIMS制作动态专题图的另一种方式即定制开发ArcXML方式作了对比。前者直接编辑ArcXML文件,操作过程复杂、不易扩展,难以达到动态制作的目的;后者实现了ArcXML到Java对象的映射,支持面向对象的方式开发,省去了处理繁琐的ArcXML过程。重点以实际应用中制作专题统计图、分类图为例,采用会话对象存储动态数据,结合Java connector的面向对象开发功能,从数据角度和显示角度实现制作动态专题图的目的。实践表明,采用Java connector方式灵活方便、切实可行。 展开更多
关键词 ARCIMS Java连接器 ARCXML 专题图
在线阅读 下载PDF
Metal Sealing Performance of Subsea X-tree Wellhead Connector Sealer 被引量:12
5
作者 ZHAO Honglin CHEN Rui +5 位作者 LUO Xiaolan DUAN Menglan LU Yinghui FU Guowei TIAN Hongping YE Daohui 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第3期649-656,共8页
The metal sealing performance of subsea X-tree wellhead connectors is crucial for the safety and reliability of subsea X-trees. In order to establish the theoretical relation between metal sealing ring's contact stre... The metal sealing performance of subsea X-tree wellhead connectors is crucial for the safety and reliability of subsea X-trees. In order to establish the theoretical relation between metal sealing ring's contact stress and its structural parameters and working pressure, a mechanical analysis method for double-cone sealing of high pressure vessels is applied in analyzing the metal sealing ring under the condition of preload and operation. As a result, the formula of the unit sealing load for the metal sealing ring under operation with residual preload is shown in this paper, which ensures that the metal sealing ring has an excellent sealing effect and can prevent the metal sealing ring from yielding. Besides, while analyzing the sealing process of the metal sealing ring, the change rule of contact stress and working pressure is concluded here, putting forward that the structural parameters of the metal sealing ring are the major factors affecting the change rule. Finally, the analytical solution through theoretical analysis is compared with the simulation result through finite element analysis in a force feedback experiment, and both are consistent with each other, which fully verifies for the design and calculation theory on metal sealing ring's contact stress and its structural parameters and working pressure deduced in this paper. The proposed research will be treated as an applicable theory guiding the design of metal seal for subsea X-tree wellhead connectors. 展开更多
关键词 sealing ring metal sealing mechanical analysis subsea X-tree wellhead connector subsea X-tree
在线阅读 下载PDF
Dynamic Responses of Mobile Offshore Base Connectors 被引量:10
6
作者 余澜 李润培 舒志 《China Ocean Engineering》 SCIE EI 2003年第4期469-479,共11页
A Mobile Offshore Base (MOB) is a multi-purpose logistics base, which can be stationed in coastal or international waters. In the conceptual design of the MOB, attention should he paid to the dynamic responses of the ... A Mobile Offshore Base (MOB) is a multi-purpose logistics base, which can be stationed in coastal or international waters. In the conceptual design of the MOB, attention should he paid to the dynamic responses of the inter-module connectors because tremendous loads occur in the connectors. In this paper, a study on dynamic responses of the MOB connectors is carried out by use of the Rigid Module Flexible Connector (RMFC) model which assumes that the module stiffness is significantly larger than that of the connector. In the analysis, the connector is modeled as a linear spring, which restricts relative translations but allows for relative rotations of modules. The 3-D source distribution method is adopted to determine the hydrodynamic forces of the modules, and the hydrodynamic interaction between modules is taken into account. The module motions and connector loads for 12 connector stiffness cases in regular and irregular waves are calculated with the multi-rigid-body motion equations. And the calculated results are compared with those from relative references. It is shown that the results obtained by different methods are in good agreement. 展开更多
关键词 mobile offshore base dynamic responses INTERACTION connector loads
在线阅读 下载PDF
Sealing Performance and Optimization of a Subsea Pipeline Mechanical Connector 被引量:4
7
作者 Li-Quan Wang Zong-Liang Wei +2 位作者 Shao-Ming Yao Yu Guan Shao-Kai Li 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第1期142-155,共14页
Researchers seldom study the optimum design of a mechanical connector for subsea oil-gas pipeline based upon the sealing performance. An optimal design method of a novel subsea pipeline mechanical connector is present... Researchers seldom study the optimum design of a mechanical connector for subsea oil-gas pipeline based upon the sealing performance. An optimal design method of a novel subsea pipeline mechanical connector is presented. By analyzing the static metal sealing mechanism, the critical condition of the sealing performance is established for this connector and the formulation method of the contact pressure on the sealing surface is created. By the method the minimum mean contact pressure of the 8.625 inch connector is calculated as 361 MPa, which is the constraint condition in the optimum design of connector.The finite element model is created in ANSYS Parametric Design Language(APDL) and the structure is optimized by the zero-order method, with variance of contact pressure as the objective function, and mean contact pressures and plastic strains as constraint variables. The optimization shows that variances of contact pressure on two sealing surfaces decrease by 72.41% and 89.33%, respectively, and mean contact pressures increase by 31.18% and 52.84%, respectively. The comparison of the optimal connectors and non-optimal connectors in the water pressure experiments and bending experiments shows that the sealing ability of optimized connectors is much higher than the rated pressure of 4.5 MPa, and the optimal connectors don’t leak under the bending moment of 52.2 kN·m.This research provides the formulation to solve contact pressure on the sealing surface and a structure optimization method to design the connectors with various dimensions. 展开更多
关键词 Mechanical connector Sealing mechanism Sealing performance Critical condition Minimum mean contact pressure Variance
在线阅读 下载PDF
Finite element model analysis of thermal failure in connector 被引量:7
8
作者 WANG Xin XU Liang-jun 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期397-402,共6页
Thermal analysis and thermal diagnose are important for small power connector especially in electronic devices since their structure is usually compact. In this paper thermal behavior of small power connector was inve... Thermal analysis and thermal diagnose are important for small power connector especially in electronic devices since their structure is usually compact. In this paper thermal behavior of small power connector was investigated. It was found that the contact resistance increased due to the Joule beating, and that increased contact resistance produced more Joule heating; this mutual action causes the connector to lose efficiency. The thermal distribution in the connector was analyzed using finite element method (FEM). The failure mechanism is discussed. It provides basis for improving the structure. The conclusion was verified by experimental results. 展开更多
关键词 connector Stress relaxation Finite element method (FEM) Thermal failure
在线阅读 下载PDF
Technical research on optimization design of contacts of electrical connector 被引量:3
9
作者 LV Bin ZHOU Sheng-jun ZHAO Lan-yan 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期506-510,共5页
Pin and socket contacts are the key parts of electrical connector as aerospace electronic components. The contacts are also the direct carriers for signal transmitting of electronic equipments, passing the signal from... Pin and socket contacts are the key parts of electrical connector as aerospace electronic components. The contacts are also the direct carriers for signal transmitting of electronic equipments, passing the signal from the input end to the output end of electrical connector. The reliability of pin and socket contacts directly influences signal transmission. The goal of this study is to enhance the contact reliability of aerospace electrical connector. Computer simulation analysis was made on contacts performance data by utilizing the simulation system developed by PCL Language of MSC software. Furthermore, the results were experi- mentally validated so as to realize the objective of optimizing contacts design. 展开更多
关键词 Electrical connector CONTACTS SIMULATION Optimization design
在线阅读 下载PDF
Discrete Element with Flexible Connector for Dynamic Analysis of 3-D Beam Structures 被引量:2
10
作者 Cheng, BR Zheng, ZC Hou, ZC 《China Ocean Engineering》 SCIE EI 1997年第1期11-20,共10页
Combined multi-body dynamics with structural dynamics, a new discrete element with flexible connector, which is applicable for 3-D beam structures, is developed in this paper. Both the generalized elastic coefficient ... Combined multi-body dynamics with structural dynamics, a new discrete element with flexible connector, which is applicable for 3-D beam structures, is developed in this paper. Both the generalized elastic coefficient matrix of the flexible connector and the mass matrix of discrete element may be off-diagonal in a general case. The zero-length rigid element is introduced to simulate the node at which multiple elements are jointed together. It may also be effective when the axes of adjacent elements are not in the same line. The examples for eigenvalue calculation show that the model is successful. It can be extended to the geometric nonlinear response analysis. 展开更多
关键词 discrete element flexible connector zero-length rigid element 3-D beam structures dynamic analysis
在线阅读 下载PDF
3D defect detection of connectors based on structured light 被引量:4
11
作者 JI Yue CHEN Yang +2 位作者 SONG Li-mei YANGYan-gang YANG Huai-dong 《Optoelectronics Letters》 EI 2021年第2期107-111,共5页
In order to realize the rapid detection of three-dimensional defects of connectors, this paper proposes a method for detecting connector defects based on structured light. This method combines structured light with bi... In order to realize the rapid detection of three-dimensional defects of connectors, this paper proposes a method for detecting connector defects based on structured light. This method combines structured light with binocular stereo vision to obtain three-dimensional data for the connector. Point cloud registration is used to identify defects and decision trees are used to classify defects. The accuracy of the 3D reconstruction results in this paper is 0.01 mm, the registration accuracy of the point cloud reaches the sub-millimeter level, and the final defect classification accuracy is 94%. The experimental results prove the effectiveness of the proposed three-dimensional connector defect detection method in connector defect detection and classification. 展开更多
关键词 DEFECT connector LIGHT
原文传递
Seismic behavior of large-scale FRP–recycled aggregate concrete–steel columns with shear connectors 被引量:2
12
作者 Zeng Lan Li Lijuan +1 位作者 Yang Xianqian Liu Feng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2019年第4期823-844,共22页
The application of fi ber-reinforced polymer (FRP) composites for the development of high-performance composite structural systems has received signifi cant recent research attention. A composite of FRP–recycled aggr... The application of fi ber-reinforced polymer (FRP) composites for the development of high-performance composite structural systems has received signifi cant recent research attention. A composite of FRP–recycled aggregate concrete (RAC)–steel column (FRSC), consisting of an outer FRP tube, an inner steel tube and annular RAC fi lled between two tubes, is proposed herein to facilitate green disposal of demolished concrete and to improve the ductility of concrete columns for earthquake resistance. To better understand the seismic behavior of FRSCs, quasi-static tests of large-scale basalt FRSCs with shear connectors were conducted. The infl uence of the recycled coarse aggregate (RCA) replacement percentage, shear connectors and axial loading method on the lateral load and deformation capacity, energy dissipation and cumulative damage were analyzed to evaluate the seismic behavior of FRSCs. The test results show that FRSCs have good seismic behavior, which was evidenced by high lateral loads, excellent ductility and energy dissipation capacity, indicating RAC is applicable in FRSCs. Shear connectors can signifi cantly postpone the steel buckling and increase the lateral loads of FRSCs, but weaken the deformation capacity and energy dissipation performance. 展开更多
关键词 recycled AGGREGATE concrete (RAC) fi ber-reinforced polymer (FRP) FRP–RAC–steel COLUMN (FRSC) shear connector seismic behavior
在线阅读 下载PDF
Evaluation of the Shear Strength of Perfobond Rib Connectors in Ultra High Performance Concrete 被引量:11
13
作者 Jae Yoon Kang Jong Sup Park +1 位作者 Woo Tai Jung Moon Seoung Keum 《Engineering(科研)》 2014年第13期989-999,共11页
Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is perf... Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action. The comparison with the predictions obtained by the previous models shows that the experimental results are close to the values given by the model proposed by Oguejiofor and Hosain [1]. 展开更多
关键词 Perfobond RIB connector Ultra High Performance Concrete Push-Out Test SHEAR Strength
暂未订购
Failure analysis of a kind of low power connector 被引量:2
14
作者 ZHOU Yi-lin ZENG Ning +1 位作者 XU Liang-jun JORGENS Stefan 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期384-392,共9页
A kind of low power connector used e.g. in household appliances was partly burned in routine experiment. The heat sources were four paralleled contacts constructed by springs (Sn/CuSn-alloy) in socket and a plug sheet... A kind of low power connector used e.g. in household appliances was partly burned in routine experiment. The heat sources were four paralleled contacts constructed by springs (Sn/CuSn-alloy) in socket and a plug sheet (Ni/Steel) while mating. The contact interfaces were detected by scanning electronic microscope (SEM) and X-ray energy dispersive spectros- copy (XEDS), obvious wear tracks and various contaminants, including element Si, Al, Na, K, S, Cl, O, etc., were found. The contamination degrees on the four paralleled contacts were different, so that the ratio of average contact resistance on the four contacts was about 5:8:3:1. The maximum contact resistance on contacts of the plug sheet reached 28 ?. The main failure rea- sons were fretting and contamination between the contact interfaces. Fretting simulation showed that connection resistance of connectors was raised up, even to ohms level. When the current increased to 5 A, the socket housing was heated and decom- posed. By the thermal analysis, it was estimated that the connector would be burned under the lower current if the current was not evenly distributed on the four paralleled contacts caused by uneven contamination. Improvement methods for connector failure are also discussed. 展开更多
关键词 connector Thermal failure Fretting CONTAMINATION
在线阅读 下载PDF
Three dimensional finite element analysis of anatomic distal radius Nitinol memory connector treating distal radius fracture 被引量:4
15
作者 苏佳灿 张春才 +8 位作者 禹宝庆 许硕贵 王家林 纪方 张雪松 吴建国 王保华 薛召军 丁祖泉 《Journal of Medical Colleges of PLA(China)》 CAS 2003年第4期226-229,共4页
Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element ana... Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing. 展开更多
关键词 distal radius Nitinol memory connector distal radius fracture 3 dimensional finite element analysis memory biomechanics
暂未订购
Structure Design and Optimization of a New Type of Subsea Pipeline Connector 被引量:3
16
作者 Xiaoming Hu (1) Liquan Wang (2) Yong Liu (2) Rubo Ge (2) Lei Tan (2) Chuangye Fu (2) fu19880725@163.com Zongliang Wei (2) 《Journal of Marine Science and Application》 2012年第1期106-110,共5页
The basic configuration of a new type of subsea pipeline connector was proposed based on the press-fitting principle, and a parametric finite element model was created using APDL language in ANSYS. Combining the finit... The basic configuration of a new type of subsea pipeline connector was proposed based on the press-fitting principle, and a parametric finite element model was created using APDL language in ANSYS. Combining the finite element model and optimization technology, the dimension optimization aiming at obtaining the minimum loading force and the optimum sealing performance was designed by the zero order optimization method. Experiments of the optimized connector were carried out. The results indicate that the optimum structural design significantly improved the indicators of the minimum loading force and sealing performance of the connector. 展开更多
关键词 subsea pipeline connector finite element model zero order optimization method structure sizeoptimization
在线阅读 下载PDF
Time Domain Calculation of Connector Loads of a Very Large Floating Structure 被引量:3
17
作者 Jiayang Gu Jie Wu +2 位作者 Enrong Qi Yifeng Guan Yubo Yuan 《Journal of Marine Science and Application》 CSCD 2015年第2期183-188,共6页
Loads generated after an air crash, ship collision, and other accidents may destroy very large floating structures (VLFSs) and create additional connector loads. In this study, the combined effects of ship collision... Loads generated after an air crash, ship collision, and other accidents may destroy very large floating structures (VLFSs) and create additional connector loads. In this study, the combined effects of ship collision and wave loads are considered to establish motion differential equations for a multi-body VLFS. A time domain calculation method is proposed to calculate the connector load of the VLFS in waves. The Longuet-Higgins model is employed to simulate the stochastic wave load. Fluid force and hydrodynamic coefficient are obtained with DNV Sesam software. The motion differential equation is calculated by applying the time domain method when the frequency domain hydrodynamic coefficient is converted into the memory function of the motion differential equation of the time domain. As a result of the combined action of wave and impact loads, high-frequency oscillation is observed in the time history curve of the connector load. At wave directions of 0° and 75°, the regularities of the time history curves of the connector loads in different directions are similar and the connector loads of C1 and C2 in the X direction are the largest. The oscillation load is observed in the connector in the Y direction at a wave direction of 75° and not at 0° This paper presents a time domain calculation method of connector load to provide a certain reference function for the future development of Chinese VLFS 展开更多
关键词 very large floating structures (VLFSs) time domainmotion differential equation COLLISION connector impact load hydrodynamic coefficient oscillation load impact load
在线阅读 下载PDF
Optimal Stiffness for Flexible Connectors on A Mobile Offshore Base at Rough Sea States 被引量:1
18
作者 WU Lin-jian WANG Yuan-zhan +4 位作者 WANG Yu-chi CHEN Jia-yu LI Yi LI Qing-mei XIE Tao 《China Ocean Engineering》 SCIE EI CSCD 2018年第6期683-695,共13页
This paper investigates a simplified method to determine the optimal stiffness of flexible connectors on a mobile offshore base(MOB) during the preliminary design stage. A three-module numerical model of an MOB was us... This paper investigates a simplified method to determine the optimal stiffness of flexible connectors on a mobile offshore base(MOB) during the preliminary design stage. A three-module numerical model of an MOB was used as a case study. Numerous constraint forces and relative displacements for the connectors at rough sea states with different wave angles were utilized to determine the optimized stiffness of the flexible connectors. The range of optimal stiffnesses for the connectors was obtained based on the combination and intersection of the optimized stiffness results, and the implementation steps were elaborated in detail. The percentage reductions of the optimized and optimal stiffness of the flexible connector were determined to quantitatively evaluate the decreases of the constraint force and relative displacement of the connectors compared with those calculated by using the original range of the connector stiffnesses. The results indicate the accuracy and feasibility of this method for determining the optimal stiffness of the flexible connectors and demonstrate the rationality and practicability of the optimal stiffness results. The research ideas, calculation process, and solutions for the optimal stiffness of the flexible connectors of an MOB in this paper can provide valuable technical support for the design of the connectors in similar semisubmersible floating structures. 展开更多
关键词 mobile offshore base(MOB) flexible connectors the optimal stiffness rough sea states
在线阅读 下载PDF
The structure and luminescence properties of three complexes based on bifunctional imidazole-dicarboxylate connector 被引量:3
19
作者 Jin-An Zhao Shu-Fang Chen +3 位作者 Dan-Dan Zhao Yan Guo Kun Peng Ji-Yong Hu 《Chinese Chemical Letters》 SCIE CAS CSCD 2013年第6期483-486,共4页
To study the diverse coordination modes of the H_2btib,three new coordination architectures,namely, [Ag(Hbtib)CH_3CN]_n(1),)[Ag(Hbtib)]_n(2) and[Pb(btib)(CH_3OH)_2]_n(3)(where H_2btib=4-((2-butyl-5-... To study the diverse coordination modes of the H_2btib,three new coordination architectures,namely, [Ag(Hbtib)CH_3CN]_n(1),)[Ag(Hbtib)]_n(2) and[Pb(btib)(CH_3OH)_2]_n(3)(where H_2btib=4-((2-butyl-5-(2- carboxy-3-(thiophen-2-yl)prop-1-enyl)-1H-imidazol-1-yl)methyl)benzoic acid) have been synthesized and characterized by elemental analysis,IR spectrum and single-crystal X-ray diffraction.Complex 1 exhibits 1D single chain structure,while 2 shows 1D double metal chain motif,and 3 features a 2D layer topology.Also,1,2 and 3 display strong emission band in the solid state at room temperature. 展开更多
关键词 Imidazole-dicarboxylate connector Crystal structure Photoluminescence property
原文传递
Experimental investigation and analytically modeling of hysteretic behavior of rigid bus-flexible connectors of 220 kV electrical substations 被引量:1
20
作者 Tang Tingxuan He Jun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第3期841-852,共12页
This paper describes the quasi-static testing and analytical modelling of the hysteretic behavior of aluminum alloy rigid bus-flexible connectors of 220 kV electrical substations.The main objective of the study is to ... This paper describes the quasi-static testing and analytical modelling of the hysteretic behavior of aluminum alloy rigid bus-flexible connectors of 220 kV electrical substations.The main objective of the study is to experimentally investigate the hysteretic behavior of six different types of rigid bus-flexible connectors 220 kV electrical substations when subjected to cyclic loading.Another objective is to theoretically study the flexibility and effectiveness of a previously proposed analytical model in fitting the experimental hysteresis loops of the tested rigid bus-flexible connectors.The experimental investigation indicates that the tested rigid bus-flexible connectors exhibit highly asymmetric hysteresis behavior along with tension stiffening effect.The theoretical study demonstrates that the generalized Bouc-Wen model has high flexibility and is effective in fitting the experimental hysteresis resisting force-displacement curves of the six tested rigid bus-flexible connectors. 展开更多
关键词 rigid bus-flexible connectors 220 kV electrical substations hysteretic behavior experimental curves analytical model
在线阅读 下载PDF
上一页 1 2 238 下一页 到第
使用帮助 返回顶部