AIM: To validate and compare the cost of microdose ^14C urea breath test (UBT) with histology and rapid urease test for the diagnosis of H Py/ori. METHODS: Ninety-four consecutive patients with dyspeptic symptoms ...AIM: To validate and compare the cost of microdose ^14C urea breath test (UBT) with histology and rapid urease test for the diagnosis of H Py/ori. METHODS: Ninety-four consecutive patients with dyspeptic symptoms undergoing gastroscopy were enrolled. Gastric biopsies were taken for histology and rapid urease test. UBT was performed after gastroscopy by microdose ^14 urea capsules. Sensitivity, specificity and accuracy of UBT were calculated and compared with histology and rapid urease test. Cost comparison of these tests was also performed. RESULTS: H pylori was diagnosed by histology and rapid urease test in 66 (70%) and 61 (65%) patients, while ^14C UBT detected infection in 63 (67%). Accuracy of UBT was 93% in comparison with histology while its positive and negative predictive values were 97% and 84%, respectively. Comparison of ^14C UBT with rapid urease test gives an accuracy of 96%, with positive and negative predictive values of 95% and 97%, respectively. These results were highly reproducible with a Kappa test (P value 〈 0.001). Cost of histology or rapid urease test with gastroscopy was 110 USD or 95 USD respectively while the cost of UBT was 15 USD.CONCLUSION: Microdose ^14C UBT was comparable to histology and rapid urease test. ^14C UBT is an economical, self sufficient and suitable test to diagnose active Hpylori infection in less developed countries.展开更多
Screening tests for blood donations are based upon sensitivity, cost-effectiveness and their suitability for high-throughput testing. Enzyme immunoassay (EIAs) for hepatitis C virus (HCV) antibodies were the initial s...Screening tests for blood donations are based upon sensitivity, cost-effectiveness and their suitability for high-throughput testing. Enzyme immunoassay (EIAs) for hepatitis C virus (HCV) antibodies were the initial screening tests introduced. The ”first generation“ antibody EIAs detected seroconversion after unduly long infectious window period. Improved HCV antibody assays still had an infectious window period around 66 d. HCV core antigen EIAs shortened the window period considerably, but high costs did not lead to widespread acceptance. A fourth-generation HCV antigen and antibody assay (combination EIA) is more convenient as two infectious markers of HCV are detected in the same assay. Molecular testing for HCV-RNA utilizing nucleic acid amplification technology (NAT) is the most sensitive assay and shortens the window period to only 4 d. Implementation of NAT in many developed countries around the world has resulted in dramatic reductions in transfusion transmissible HCV and relative risk is now < 1 per million donations. However, HCV serology still continues to be retained as some donations are serology positive but NAT negative. In resource constrained countries HCV screening is highly variable, depending upon infrastructure, trained manpower and financial resource. Rapid tests which do not require instrumentation and are simple to perform are used in many small and remotely located blood centres. The sensitivity as compared to EIAs is less and wherever feasible HCV antibody EIAs are most frequently used screening assays. Efforts have been made to implement combined antigen-antibody assays and even NAT in some of these countries.展开更多
程序似然不变量是程序中隐含的属性,可以应用于程序验证、软件测试技术、逆向工程等领域。针对自动化测试工具C++Test产生的测试用例集,利用程序不变量分析工具Daikon判断这些测试用例是否改变了当前的不变量;并将两种工具结合生产一种...程序似然不变量是程序中隐含的属性,可以应用于程序验证、软件测试技术、逆向工程等领域。针对自动化测试工具C++Test产生的测试用例集,利用程序不变量分析工具Daikon判断这些测试用例是否改变了当前的不变量;并将两种工具结合生产一种自动化测试用例集约简工具CDRT(C++Test And Daikon Reduction Testing),从而达到约简测试用例集的效果,再通过变异测试工具INSURE++对简化后的测试用例集进行评估。实验结果表明,CDRT工具能有效地约简测试用例集。展开更多
Objective To determine the interaction between 2450-MHz microwaves (MW) radiation and mitomycin C (MMC). Methods The synergistic genotoxic effects of low-intensity 2450-MHz microwave and MMC on human lymphocytes were ...Objective To determine the interaction between 2450-MHz microwaves (MW) radiation and mitomycin C (MMC). Methods The synergistic genotoxic effects of low-intensity 2450-MHz microwave and MMC on human lymphocytes were studied using single cell gel electrophoresis (SCGE) assay (comet assay) and cytokinesis-blocked micronucleus (CBMN) test in vitro. The whole blood cells from a male donor and a female donor were either only exposed to 2450-MHz microwaves (5.0 mW/cm2) for 2 h or only exposed to MMC (0.0125 μ/mL, 0.025 μg/mL, 0.05μg/mL and 0.1 μg/mL) for 24 h; and the samples were exposed to MMC for 24 h after exposure to MW for 2 h. Results In the comet assay, the comet lengths ( 29.1 μm and 25.9 μm) of MW were not significantly longer than those (26.3 μrn and 24.1 μm) of controls (P>0.05). The comet lengths (57.4 μm, 68.9 μm, 91.4 μm, 150.6μm and 50.6 μm, 71.7μm, 100.1 μm, 145.1 μm) of 4 MMC groups were significantly longer than those of controls (P<0.01). The comet lengths (59.1 μm, 92.3 μm, 124.5 μm, 182.7 μm and 57.4 μm, 85.5 μm, 137.5 μm, 178.3 μm) of 4 MW plus MMC groups were significantly longer than those of controls too (P<0.01). The comet lengths of MW plus MMC groups were significantly longer than those of the corresponding MMC doses (P<0.05 or P<0.01) when the doses of MMC were ≥50.025 μg/mL. In the CBMN, the micronucleated cell (MNC) rates of MW were 5% and 6%, which showed no difference compared with those (4‰ and 4‰) of controls (P>0.05). The MNC rates of 4 MMC groups were 8‰, 9‰, 14‰, 23‰ and 8‰, 8‰, 16‰, 30‰ respectively. When the doses of MMC were 3≥0.05 μg/mL, MNC rates of MMC were higher than those of controls (P<0.05). MNC rates of 4 MW plus MMC groups were 12‰, 13‰, 20‰, 32‰ and 8‰, 9‰, 23‰, 40‰. When the doses of MMC were 5≥0.05 μg/mL, MNC rates of MW plus MMC groups were much higher than those of controls (P<0.01). MNC rates of 4 MW plus MMC groups were not significantly higher than those of the corresponding MMC doses. Conclusion The low-intensity 2450-MHz microwave radiation can not induce DNA and chromosome damage, but can increase DNA damage effect induced by MMC in comet assay.展开更多
Light hydrocarbon (methane, ethane, propane, butane and CO2) test and C isotopic analysis of CO are conducted for over 100 lower-layer atmospheric samples from the East China Sea slope and the Okinawa Trough. The resu...Light hydrocarbon (methane, ethane, propane, butane and CO2) test and C isotopic analysis of CO are conducted for over 100 lower-layer atmospheric samples from the East China Sea slope and the Okinawa Trough. The results show that the lower-layer atmosphere mainly consists of CO2 and then of CH4, and the CO2 concentrations are calculated to have a high average value of 0.87 omega/10(-2) about three times that of the regional background (0-3 omega/10(-2)). The result also shows that the average value of C isotope - 20.8 x 10(-3) is given to the CO2, inferring that it is inorganic gas. Thus, for the future 's work in the Okinawa Trough, special attention should be paid to CO2 hydrate, which is very possibly an important hydrate type.展开更多
基金University Research Council Grant, No. 041F431YC
文摘AIM: To validate and compare the cost of microdose ^14C urea breath test (UBT) with histology and rapid urease test for the diagnosis of H Py/ori. METHODS: Ninety-four consecutive patients with dyspeptic symptoms undergoing gastroscopy were enrolled. Gastric biopsies were taken for histology and rapid urease test. UBT was performed after gastroscopy by microdose ^14 urea capsules. Sensitivity, specificity and accuracy of UBT were calculated and compared with histology and rapid urease test. Cost comparison of these tests was also performed. RESULTS: H pylori was diagnosed by histology and rapid urease test in 66 (70%) and 61 (65%) patients, while ^14C UBT detected infection in 63 (67%). Accuracy of UBT was 93% in comparison with histology while its positive and negative predictive values were 97% and 84%, respectively. Comparison of ^14C UBT with rapid urease test gives an accuracy of 96%, with positive and negative predictive values of 95% and 97%, respectively. These results were highly reproducible with a Kappa test (P value 〈 0.001). Cost of histology or rapid urease test with gastroscopy was 110 USD or 95 USD respectively while the cost of UBT was 15 USD.CONCLUSION: Microdose ^14C UBT was comparable to histology and rapid urease test. ^14C UBT is an economical, self sufficient and suitable test to diagnose active Hpylori infection in less developed countries.
文摘Screening tests for blood donations are based upon sensitivity, cost-effectiveness and their suitability for high-throughput testing. Enzyme immunoassay (EIAs) for hepatitis C virus (HCV) antibodies were the initial screening tests introduced. The ”first generation“ antibody EIAs detected seroconversion after unduly long infectious window period. Improved HCV antibody assays still had an infectious window period around 66 d. HCV core antigen EIAs shortened the window period considerably, but high costs did not lead to widespread acceptance. A fourth-generation HCV antigen and antibody assay (combination EIA) is more convenient as two infectious markers of HCV are detected in the same assay. Molecular testing for HCV-RNA utilizing nucleic acid amplification technology (NAT) is the most sensitive assay and shortens the window period to only 4 d. Implementation of NAT in many developed countries around the world has resulted in dramatic reductions in transfusion transmissible HCV and relative risk is now < 1 per million donations. However, HCV serology still continues to be retained as some donations are serology positive but NAT negative. In resource constrained countries HCV screening is highly variable, depending upon infrastructure, trained manpower and financial resource. Rapid tests which do not require instrumentation and are simple to perform are used in many small and remotely located blood centres. The sensitivity as compared to EIAs is less and wherever feasible HCV antibody EIAs are most frequently used screening assays. Efforts have been made to implement combined antigen-antibody assays and even NAT in some of these countries.
文摘程序似然不变量是程序中隐含的属性,可以应用于程序验证、软件测试技术、逆向工程等领域。针对自动化测试工具C++Test产生的测试用例集,利用程序不变量分析工具Daikon判断这些测试用例是否改变了当前的不变量;并将两种工具结合生产一种自动化测试用例集约简工具CDRT(C++Test And Daikon Reduction Testing),从而达到约简测试用例集的效果,再通过变异测试工具INSURE++对简化后的测试用例集进行评估。实验结果表明,CDRT工具能有效地约简测试用例集。
基金This work was supported by the Natural Science Foundation of Zhejiang Province (No.300434), 2001-2003, and International Cooperation Foundation of Science-Technique Bureau of Zhejiang Province (No. 012104), 2001-2002.
文摘Objective To determine the interaction between 2450-MHz microwaves (MW) radiation and mitomycin C (MMC). Methods The synergistic genotoxic effects of low-intensity 2450-MHz microwave and MMC on human lymphocytes were studied using single cell gel electrophoresis (SCGE) assay (comet assay) and cytokinesis-blocked micronucleus (CBMN) test in vitro. The whole blood cells from a male donor and a female donor were either only exposed to 2450-MHz microwaves (5.0 mW/cm2) for 2 h or only exposed to MMC (0.0125 μ/mL, 0.025 μg/mL, 0.05μg/mL and 0.1 μg/mL) for 24 h; and the samples were exposed to MMC for 24 h after exposure to MW for 2 h. Results In the comet assay, the comet lengths ( 29.1 μm and 25.9 μm) of MW were not significantly longer than those (26.3 μrn and 24.1 μm) of controls (P>0.05). The comet lengths (57.4 μm, 68.9 μm, 91.4 μm, 150.6μm and 50.6 μm, 71.7μm, 100.1 μm, 145.1 μm) of 4 MMC groups were significantly longer than those of controls (P<0.01). The comet lengths (59.1 μm, 92.3 μm, 124.5 μm, 182.7 μm and 57.4 μm, 85.5 μm, 137.5 μm, 178.3 μm) of 4 MW plus MMC groups were significantly longer than those of controls too (P<0.01). The comet lengths of MW plus MMC groups were significantly longer than those of the corresponding MMC doses (P<0.05 or P<0.01) when the doses of MMC were ≥50.025 μg/mL. In the CBMN, the micronucleated cell (MNC) rates of MW were 5% and 6%, which showed no difference compared with those (4‰ and 4‰) of controls (P>0.05). The MNC rates of 4 MMC groups were 8‰, 9‰, 14‰, 23‰ and 8‰, 8‰, 16‰, 30‰ respectively. When the doses of MMC were 3≥0.05 μg/mL, MNC rates of MMC were higher than those of controls (P<0.05). MNC rates of 4 MW plus MMC groups were 12‰, 13‰, 20‰, 32‰ and 8‰, 9‰, 23‰, 40‰. When the doses of MMC were 5≥0.05 μg/mL, MNC rates of MW plus MMC groups were much higher than those of controls (P<0.01). MNC rates of 4 MW plus MMC groups were not significantly higher than those of the corresponding MMC doses. Conclusion The low-intensity 2450-MHz microwave radiation can not induce DNA and chromosome damage, but can increase DNA damage effect induced by MMC in comet assay.
文摘Light hydrocarbon (methane, ethane, propane, butane and CO2) test and C isotopic analysis of CO are conducted for over 100 lower-layer atmospheric samples from the East China Sea slope and the Okinawa Trough. The results show that the lower-layer atmosphere mainly consists of CO2 and then of CH4, and the CO2 concentrations are calculated to have a high average value of 0.87 omega/10(-2) about three times that of the regional background (0-3 omega/10(-2)). The result also shows that the average value of C isotope - 20.8 x 10(-3) is given to the CO2, inferring that it is inorganic gas. Thus, for the future 's work in the Okinawa Trough, special attention should be paid to CO2 hydrate, which is very possibly an important hydrate type.