期刊文献+
共找到15,329篇文章
< 1 2 250 >
每页显示 20 50 100
In vitro biodegradability and biocompatibility of porous Mg-Zn scaffolds coated with nano hydroxyapatite via pulse electrodeposition 被引量:2
1
作者 Z.S.SEYEDRAOUFI Sh.MIRDAMADI 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2015年第12期4018-4027,共10页
The biodegradability and biocompatibility of porous Mg-2Zn(mass fraction, %) scaffolds coated with nano hydroxyapatite(HAP) were investigated. The nano HAP coating on Mg-2Zn scaffolds was prepared by the pulse ele... The biodegradability and biocompatibility of porous Mg-2Zn(mass fraction, %) scaffolds coated with nano hydroxyapatite(HAP) were investigated. The nano HAP coating on Mg-2Zn scaffolds was prepared by the pulse electrodeposition method. The as-deposited scaffolds were then post-treated with alkaline solution to improve the biodegradation behavior and biocompatibility for implant applications. The microstructure and composition of scaffold and nano HAP coating, as well as their degradation and cytotoxicity behavior in simulated body fluid(SBF) were investigated. The post-treated coating is composed of needle-like HAP with the diameter less than 100 nm developed almost perpendicularly to the substrate, which exhibits a similar composition to natural bone. It is found that the products of immersion in SBF are identified to be HAP,(Ca,Mg)3(PO4)2 and Mg(OH)2. The bioactivity, biocompatibility and cell viabilities for the as-coated and post-treated scaffold extracts are higher than those for the uncoated scaffold. MG63 cells are found to adhere and proliferate on the surface of the as-coated and post-treated scaffolds, making it a promising choice for medical application. The results show that the pulse electrodeposition of nano HAP coating and alkaline treatment is a useful approach to improve the biodegradability and bioactivity of porous Mg-Zn scaffolds. 展开更多
关键词 porous Mg-Zn scaffold hydroxyapatite coating pulse electrodeposition biodegradability biocompatibility
在线阅读 下载PDF
Next-generation craniomaxillofacial implants for reconstructive surgery: balancing biomechanics,biocompatibility,and bioactivity
2
作者 Bozhi Hou Yuehua Li Raymond Chung Wen Wong 《International Journal of Oral Science》 2026年第1期1-17,共17页
Next-generation craniomaxillofacial implants(CMFIs) are redefining personalized bone reconstruction by balancing and optimizing biomechanics,biocompatibility,and bioactivity—the "3Bs".This review highlights... Next-generation craniomaxillofacial implants(CMFIs) are redefining personalized bone reconstruction by balancing and optimizing biomechanics,biocompatibility,and bioactivity—the "3Bs".This review highlights recent progress in implant design,material development,additive manufacturing,and preclinical evaluation.Emerging biomaterials,including bioresorbable polymers,magnesium alloys,and composites with bioactive ceramics,enable patient-specific solutions with improved safety and functionality.Triply periodic minimal surface(TPMS) architectures exemplify how structural design can enhance both mechanical performance and biological integration.Additive manufacturing technologies further allow the fabrication of geometrically complex,customized impla nts that meet individual anatomical and pathological needs.In parallel,multiscale evaluation techniques—from mechanical testing to in vitro and in vivo models—provide comprehensive insights into implant performance and safety.Looking ahead,the field is poised to benefit from several transformative trends:the development of smart and multifunctional biomaterials;Al-driven design frameworks that leverage patient-specific data and computational modeling;predictive additive manufacturing with real-time quality control;and advanced biological testing platforms for preclinical evaluation.Together,these advances form the foundation of a data-informed,translational pipeline from bench to bedside.Realizing the full potential of nextgene ration CMFIs will require close interdisciplina ry collaboration across mate rials science,computational engineering,and clinical medicine. 展开更多
关键词 bioresorbable polymersmagnesium alloysand biocompatibility next generation craniomaxillofacial implants craniomaxillofacial implants cmfis periodic mini balancing optimizing BIOMECHANICS bioactive ceramicsenable
暂未订购
Effects of metal ion implantation(Fe,Ti,Zn and Zr)on mechanical properties,corrosion resistance and biocompatibility of WE43 Mg alloy 被引量:1
3
作者 Lianhui Li Zhiqiang Zhang +4 位作者 Dechuang Zhang Fugang Qi Yilong Dai Wenwen Wei Xiaoping Ouyang 《Journal of Magnesium and Alloys》 2025年第1期296-310,共15页
To improve the corrosion resistance of biodegradable Mg alloys,WE43 alloys were implanted with Fe,Ti,Zn and Zr ions at the same implantation dose.The surface morphology,valence state of elements,nano-hardness(NH),elas... To improve the corrosion resistance of biodegradable Mg alloys,WE43 alloys were implanted with Fe,Ti,Zn and Zr ions at the same implantation dose.The surface morphology,valence state of elements,nano-hardness(NH),elastic modulus(EM),degradation rate and in vitro cell experiments of the modified WE43 alloys were systematically studied.A modified layer composed of Mg,MgO,the implanted elements and their oxides was formed on the modified alloys.Since high-speed metal ions caused severe surface lattice damage,the surface hardness of the substrate considerable increased.Electrochemical tests demonstrated a substantial enhancement in the corrosion resistance of the modified alloys via the implantation of Ti and Zr ions,resulting in a reduction of the corrosion current density to 88.1±9.9 and 15.6±11.4μA cm^(−2),respectively,compared with the implantation of Fe and Zn ions.Biocompatibility tests showed that the implantation of Fe,Ti,Zn and Zr ions enhanced the anticoagulant and hemolytic resistance of the WE43 alloy.All surface-modified samples showed negligible cytotoxicity(0-1)at 12.5%extract concentration.Moreover,the alloys implanted with Fe,Ti and Zn ions significantly promoted proliferation of human umbilical vein endothelial cells(HUVEC)compared with the unmodified alloy.The results demonstrate that Ti ion implantation is the best choice for WE43 alloy modification to achieve outstanding corrosion resistance and biocompatibility. 展开更多
关键词 Biomaterial Ion implantation Surface mechanical properties Corrosion rate biocompatibility
在线阅读 下载PDF
Biodegradation and biocompatibility of calcium phosphate-coated magnesium in eye environment,in vitro and in vivo
4
作者 Yi Chen Yi Lin +8 位作者 Wangdu Luo Huanhuan Gao Yaobo Hu Liying Qiao Jia She Lin Xie Xiangji Li Yong Wang Fusheng Pan 《Journal of Magnesium and Alloys》 2025年第7期3081-3095,共15页
The possible application of magnesium(Mg)in glaucoma surgical treatment has been investigated in our previous work.In this paper,the degradation behavior and biocompatibility of Mg coated with hydroxyapatite(HA)and di... The possible application of magnesium(Mg)in glaucoma surgical treatment has been investigated in our previous work.In this paper,the degradation behavior and biocompatibility of Mg coated with hydroxyapatite(HA)and dicalcium phosphate dihydrate(DCPD)in eye environment were evaluated,and uncoated Mg was used for comparison.It was found that uniform corrosion occurred macroscopically to the coated Mg samples in sodium lactate ringer’s injection(SLRI)as well as in the rabbit eyes.In micro-scale,the corrosion was characterized by local cracking and pitting primarily.Mg and calcium(Ca)were incorporated into the surface corrosion products and a multi-layer structure was formed.Compared to other samples,HA-coated Mg slowed down dramatically the alkalinity of the solution and the ion release of the sample,and exhibited the lowest corrosion rate in SLRI,which was about 0.22 mm/a.In terms of biocompatibility,fibroblasts demonstrated high viability in the HA-coated and DCPD-coated Mg groups(p<0.05)in vitro.In vivo,HA-coated Mg was found to show lower inflammatory response and fibrosis than the other groups did,as indicated by hematoxylin-eosin and immunofluorescence staining.During the degrading process of HA-coated Mg in the rabbits’eyes,no inflammation was found in the anterior chamber,lens,and vitreous body.HA-coated Mg was fully biodegraded fifteen weeks post-operation,and the scleral drainage channel(SDC)was formed without obvious scarring.It is concluded that HA-coated Mg implantation is a promising adjunctive procedure to improve the success rate of trabeculectomy.Statement of significance:Magnesium(Mg)has shown to be a potential biomaterial for ophthalmic implants in our previous work.However,inflammatory response resulted from the low corrosion resistance of Mg is a major concern.It is shown here that Mg coated with different calcium phosphates can improve these properties in varying degrees and keep the scleral drainage channel unobstructed and unscarred.Based on our in vitro and in vivo studies,HA-coated Mg exhibited a better degradation behavior and excellent biocompatibility.The scleral drainage channel still exists and aqueous humor flows out smoothly after the full degradation of the implant.It is concluded that HA-coated Mg is a promising biomaterial to increase the therapeutic efficiency of trabeculectomy for glaucoma. 展开更多
关键词 MAGNESIUM Calcium phosphate coating BIODEGRADATION biocompatibility GLAUCOMA
暂未订购
Impact of scandium on the microstructure,mechanical properties,corrosion behaviors and in-vitro biocompatibility of a Zn-0.1Li alloy
5
作者 He Huang Gencheng Gong +9 位作者 Hui Yu Zhipei Tong Qinggong Jia Liudang Fang Shaokang Guan Jing-Jun Nie DaFu Chen Jing Bai Dong Bian Yufeng Zheng 《Journal of Materials Science & Technology》 2025年第26期235-251,共17页
The poor mechanical properties of pure zinc(Zn)restrain its applications in orthopedics,which requires high loading capacity.Alloying with lithium(Li)element can enhance strength,however,the work-hardening rate is imp... The poor mechanical properties of pure zinc(Zn)restrain its applications in orthopedics,which requires high loading capacity.Alloying with lithium(Li)element can enhance strength,however,the work-hardening rate is impaired with increased Li content.Here,introducing scandium(Sc)into a low Li-containing Zn-0.1Li alloy could effectively refine its microstructure,reducing the average grain size from 10 to 4μm.The refinement in microstructure led to a significant improvement in tensile strength,im-proving from 257 MPa of Zn-0.1Li to 341 MPa of Zn-0.1Li-0.1Sc,meanwhile,the work-hardening rate remained positive during the whole plastic deformation stage.The addition of Sc-impaired elongation is due to numerous microcracks formed at the Zn/ScZn_(12)interfaces,as well as in the large-sized ScZn_(12)particles.Corrosion tests revealed an accelerated corrosion rate due to the galvanic effect between the Zn matrix and ScZn_(12)phase.Even so,the Zn-0.1Li-1.0Sc alloy still exhibited superior biocompatibility with rat/mouse mesenchymal stem cells and close osteogenesis capacity to the original Zn-0.1Li alloy.These findings demonstrated that the addition of Sc in low Li-containing alloys could improve mechanical strength without sacrificing the work-hardening rate and biocompatibility. 展开更多
关键词 Biodegradable zinc Strengthening mechanism Localized corrosion biocompatibility ScZn_(12)phase
原文传递
Comprehensive evaluation of corrosion resistance and biocompatibility of ultrafine-grained TiMoNb alloy for dental implants
6
作者 Zongyuan Li Dingshan Liang +5 位作者 Chuanxin Zhong Tian Wan Weiwei Zhu Jiasi Luo Jianfeng Yan Fuzeng Ren 《Journal of Materials Science & Technology》 2025年第18期247-259,共13页
To address the limited wear resistance observed in traditional titanium alloys,we have developed an ultrafine-grained equiatomic TiMoNb compositionally complex alloy(CCA)with exceptional wear resistance.However,there ... To address the limited wear resistance observed in traditional titanium alloys,we have developed an ultrafine-grained equiatomic TiMoNb compositionally complex alloy(CCA)with exceptional wear resistance.However,there is a significant lack of in vitro and in vivo evaluation of the TiMoNb CCA for biomedical applications.In this study,we comprehensively evaluate the corrosion behavior,tribo-corrosion performance,biocompatibility,and osseointegration of the TiMoNb alloy.Our findings indicate that the alloy exhibits strong corrosion resistance and stable tribo-corrosion behavior,attributed to the presence of Ti-rich nanoscale precipitates that impede tribo-corrosion-induced shear deformation,along with a protective nanoscale oxide layer.Furthermore,in vitro and in vivo evaluations demonstrate the excellent biocompatibility of the TiMoNb alloy and reveal its ability to promote the regeneration of defective femurs and its favorable bone osseointegration capability.Overall,our study underscores the potential of the TiMoNb alloy as a promising material for dental implants and provides valuable insights into the tribo-corrosion mechanisms of ultrafine-grained alloys. 展开更多
关键词 TiMoNb Tribo-corrosion biocompatibility OSTEOINTEGRATION
原文传递
The role of microstructure on the degradation behavior and biocompatibility of Mg-Ca-Zn-Y-Mn alloy
7
作者 Diana C.Martinez Anna Dobkowska +9 位作者 Alessia Paradiso Daria Drozdenko Andrea Farkas Kristián Máthis Péter Jenei Péter Nagy Jeno Gubicza Shin-ichi Inoue Yoshihito Kawamura Wojciech Swieszkowski 《Journal of Magnesium and Alloys》 2025年第9期4278-4298,共21页
In this study,the effect of annealing on the microstructure and following corrosion and biological properties of Mg-1.0Ca-0.5Zn-0.1Y-0.03Mn(at.%)alloy prepared by rapid solidified powder metallurgy was investigated.Th... In this study,the effect of annealing on the microstructure and following corrosion and biological properties of Mg-1.0Ca-0.5Zn-0.1Y-0.03Mn(at.%)alloy prepared by rapid solidified powder metallurgy was investigated.The annealing at 300℃ for 2 h did not change the grain size significantly;however,a slight growth of Mg_(2)Ca precipitates was observed.When the annealing temperature increased up to 400℃ for 2 h,full recrystallization of the alloy occurred;the grains and precipitates grew noticeably.Those changes were responsible for decreasing the corrosion and the tribocorrosion resistance of the alloy.Due to lowered resistance to the corrosion medium,the cell viability was also reduced.Although MG63 cells on the annealed specimens developed filopodia,cell-to-cell communication was not observed. 展开更多
关键词 Magnesium alloys CORROSION In vitro tests biocompatibility
在线阅读 下载PDF
Effect of low Zn content on corrosion resistance and biocompatibility of biodegradable Mg-Zn-Y-Zr alloys
8
作者 Xinyi Zhou Jun Cheng +4 位作者 Jun Xu Yipei Mao Yang Dong Yixuan He Meifeng He 《International Journal of Minerals,Metallurgy and Materials》 2025年第10期2534-2546,共13页
Although the degradability and biosafety of magnesium alloys make them advantageous for biological applications,medical implants made of magnesium alloys often fail prematurely due to corrosion.Therefore,improving the... Although the degradability and biosafety of magnesium alloys make them advantageous for biological applications,medical implants made of magnesium alloys often fail prematurely due to corrosion.Therefore,improving the corrosion resistance of magnesium alloys has become an urgent problem in the alloy design process.In this study,we designed and prepared Mg-xZn-0.5Y-0.5Zr(x=1,2,and 3,wt%)alloys in a hot extruded state and analyzed their surface structure through scanning electron microscopy,energy dispersion spectrometry,and X-ray diffraction.It was found that increasing the Zn content refined the recrystallized grains in the alloy.Particularly in Mg-3Zn-0.5Y-0.5Zr,the I phase became finer,forming both granular and nanoscale needle-like particles.Surface characterization after the immersion experiment showed that the corrosion product layer was mainly composed of Mg(OH)_(2),Zn(OH)_(2),CaCO_(3),and hy-droxyapatite.The degradation rate of ZW305K was the lowest,measured as 4.1 and 6.0 mm·a^(-1) with the hydrogen precipitation method and weight loss method respectively.Electrochemical experiments further explained the corrosion circuit model of the alloy in solution and confirmed the earlier results.The maximum polarization resistance of ZW305K was 874.5Ω·cm^(2),and the lowest corrosion current density was 0.104 mA·cm^(-2).As a biomedical alloy,it must exhibit good biocompatibility,so the alloy was also tested through cytotoxicity,cell adhesion,and staining experiments.The cell viability of each group after 48 h was greater than 80%,showing that the addition of zinc enhances the alloy’s biocompatibility.In summary,the prepared alloys have the potential to be used as biodegradable implant materials. 展开更多
关键词 Mg-Zn-Y-Zr alloys corrosion resistance MICROSTRUCTURE hot extrusion biocompatibility
在线阅读 下载PDF
Degradation and biocompatibility of Mg-Dy-Zn alloys containing the LPSO and γʹ phases under physiological conditions
9
作者 Genzhi Jiang Yuanding Huang +6 位作者 Heike Helmholz Nico Scharnagl Ci Song Zijian Yu Yue Zhang Regine Willumeit-Römer Norbert Hort 《Journal of Magnesium and Alloys》 2025年第12期5897-5910,共14页
Previous work indicated that long-period stacking ordered(LPSO) phase and/or γ’ in rare earth containing Mg biomaterials had contradictory mechanisms responsible for their degradation in less complex or standard sal... Previous work indicated that long-period stacking ordered(LPSO) phase and/or γ’ in rare earth containing Mg biomaterials had contradictory mechanisms responsible for their degradation in less complex or standard salt media, such as 0.9 % NaCl solution. They needed to be further investigated in a more realistic simulated body fluid(SBF). The present work investigated the influence of the amount and types of intermetallics on the degradation behavior of as-cast Mg-xDy-Zn(x = 5, 10, 15 wt.%) alloys using immersion test in Dulbecco's modified Eagle's medium(DMEM) + Glutamax together with 10 % Fetal bovine serum(FBS) under cell culture conditions. It was revealed that the existence of intermetallics exhibited different effects on the degradation behavior of alloys. At the early stage of immersion, Mg-10Dy-1.5Zn alloy suffered the most serious degradation among these three alloys, owing to its more severe micro galvanic corrosion. With the immersion proceeding, the degradation rate of Mg-5Dy-1.5Zn alloy consistently increased because of the scattered distribution of few intermetallics. In contrast, the continuous network structure of intermetallics and a compact degradation layer provided protection from further degradation for Mg-10Dy-1.5Zn and Mg-15Dy-1.5Zn alloys. In the as-cast Mg-5Dy-1.5Zn alloy, only small amount of intermetallics composed of W, γ’ and18R LPSO phases acted as galvanic cathodes, accelerating its degradation. With Dy content increasing to 10 and 15 wt.%, large amounts of intermetallics including 18R LPSO and dense γ’ phases were formed, which on the other hand can serve as a continuous network barrier to retard degradation propagation. Finally, the good adhesion and proliferation of the Human umbilical cord perivascular(HUCPV) on the surface of the Mg-10Dy-1.5Zn and Mg-15Dy-1.5Zn alloy indicated their good biocompatibility. 展开更多
关键词 Magnesium-dysprosium-zinc alloys Network structure Volume fraction Degradation and biocompatibility In vitro
在线阅读 下载PDF
A significant improvement in corrosion resistance and biocompatibility in ZrNbTiCrCu high-entropy films induced by the precipitation of Cu
10
作者 Xiaofei Ma Ping Ren +9 位作者 Shangzhou Zhang Xiaochun He Yang Li Xuelei Yin Huanyu Li Shizeng Dang Daliang Yu Jianxun Qiu Xin Zhou Bing Zhou 《Journal of Materials Science & Technology》 2025年第16期213-224,共12页
Utilizing nanotechnology and composites to create a protective film on titanium alloy is an effective means of achieving the desired high performance.Self-assembly of nanocomposite structures offers a promising route ... Utilizing nanotechnology and composites to create a protective film on titanium alloy is an effective means of achieving the desired high performance.Self-assembly of nanocomposite structures offers a promising route to forming high entropy alloy films(HEAFs),but controlled preparation remains challeng-ing.This work used magnetron sputtering through adjusting preparation parameters to prepare ZrNbTi-CrCu HEAFs,achieving a significant improvement in corrosion resistance and biocompatibility induced by the precipitation of Cu.According to the electrochemical corrosion test,without obvious corrosion pits on the surface of S2 after corrosion,a passivation film composed of bimetallic oxide CuCrO2 formed on the film surface,indicating that ZrNbTiCrCu HEAFs have remarkable corrosion resistance performance.In the cytocompatibility experiment,the cell viability of HEAFs reached over 95%due to the precipitation of Cu,suggesting their excellent biocompatibility.In addition,ZrNbTiCrCu HEAFs exhibit outstanding an-tibacterial ability,especially when the sputtering current is 0.6 A,and the in vitro antibacterial rate of the sample against Escherichia coli is close to 99%. 展开更多
关键词 High entropy alloy film Magnetron sputtering Phase precipitation Corrosion resistance biocompatibility
原文传递
Springback Behavior and Biocompatibility inβ-Type Ti-Mo-O Alloys
11
作者 Cheng Ren Xiaohua Min +1 位作者 Sujie Zhang Weiqiang Wang 《Acta Metallurgica Sinica(English Letters)》 2025年第2期313-326,共14页
Ti-Mo-O alloys were used to analyze the effect of Mo and O contents on the mechanical compatibility and biocompatibility.The bending modulus,bending yield strength and springback ratio of the alloys were evaluated by ... Ti-Mo-O alloys were used to analyze the effect of Mo and O contents on the mechanical compatibility and biocompatibility.The bending modulus,bending yield strength and springback ratio of the alloys were evaluated by using three-point bending tests and bending load-unloading tests.The biocompatibility was investigated by the adhesion,proliferation and the alkaline phosphatase(ALP)activity of mouse osteoblast-like cells(MC3T3-E1).The results showed that the bending modulus and bending yield strength first were increased and then decreased with the increase in Mo content,while the springback ratio exhibited an opposite trend to the bending modulus.With the increase in O content,the bending modulus remained almost constant,while the bending yield strength was increased.The springback ratio exhibited a similar trend to the bending yield strength.The in vitro biological experiments showed that the Ti-Mo-O alloys had excellent biocompatibility due to the formed stable oxide films on their surface.With the increase in O and Mo contents,the TiO_(2)-MoO_(2)oxide film became denser.Combining with mechanical compatibility and biocompatibility,the Ti-15Mo-0.2O and Ti-15Mo-0.3O alloys were more suitable for the biomedical application of spinal fixation device. 展开更多
关键词 β-type titanium alloys Bending modulus Bending yield strength SPRINGBACK biocompatibility
原文传递
Biobased Polyesters Derived from 2-Methoxyhydroquinone:Impact of Cyclic and Alkyl Chain Segments on Their Thermomechanical Properties,Biodegradability,and Ecotoxicity
12
作者 Hao-Ming Xu Zheng-Zai Cheng +2 位作者 Zi-Ting Zhou Lesly Dasilva Wandji Djouonkep Mario Gauthier 《Chinese Journal of Polymer Science》 2025年第8期1320-1332,共13页
To enhance the properties of bio-based polyesters,enabling them to more closely mimic the characteristics of terephthalate-based materials,a series of aliphatic-aromatic copolyesters(P_(1)–P_(4))were synthesized via ... To enhance the properties of bio-based polyesters,enabling them to more closely mimic the characteristics of terephthalate-based materials,a series of aliphatic-aromatic copolyesters(P_(1)–P_(4))were synthesized via melt polycondensation.Diester monomers M and N were synthesized via the Williamson reaction,using lignin-derived 2-methoxyhydroquinone,methyl 4-chloromethylbenzoate,and methyl chloroacetate as starting materials.Hydroquinone bis(2-hydroxyethyl)ether(HQEE)and 1,4-cyclohexanedimethanol(CHDM)were employed as cyclic segments,while 1,4-butanediol(BDO)and 1,6-hexanediol(HDO)served as alkyl segments within the copolymer structures.The novel copolyesters exhibited molecular weights(Mw)in the range of 5.25×10^(4)–5.87×10^(4) g/mol,with polydispersity indices spanning from 2.50–2.66.Evaluation of the structural and thermomechanical properties indicated that the inclusion of alkyl segments induced a reduction in both crystallinity and molecular weight,while significantly improving the flexibility,whereas cyclic segments enhanced the processability of the copolyesters.Copolyesters P_(1) and P_(2),due to the presence of rigid segments(HQEE and CHDM),displayed relatively high glass transition temperatures(Tg>80℃)and melting temperatures(Tm>170℃).Notably,P_(2),incorporating CHDM,exhibited superior elongation properties(272%),attributed to the enhanced chain mobility resulting from its trans-conformation,while P_(1) was found to be likely brittle owing to excessive chain stiffness.Biodegradability assessment using earthworms as bioindicators revealed that the copolyesters demonstrated moderate degradation profiles,with P_(2) exhibiting a degradation rate of 4.82%,followed by P_(4) at 4.07%,P_(3) at 3.65%,and P_(1) at 3.17%.The higher degradation rate of P_(2) was attributed to its relatively larger d-spacing and lower toxicity,which facilitated enzymatic hydrolytic attack by microorganisms.These findings highlight the significance of optimizing the structural chain segments within aliphatic-aromatic copolyesters.By doing so,it is possible to significantly enhance their properties and performance,offering viable bio-based alternatives to petroleum-based polyesters such as polyethylene terephthalate(PET). 展开更多
关键词 2-Methoxyhydroquinone Aliphatic-aromatic polyesters Cyclic and alkyl chain segments biodegradability
原文传递
Effects of chitosan coating on biocompatibility of Mg-6%Zn-10%Ca_3(PO_4)_2 implant 被引量:3
13
作者 赵俊 陈良建 +5 位作者 余琨 陈畅 戴翌龙 乔雪岩 颜阳 余志明 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2015年第3期824-831,共8页
A Mg?6%Zn?10%Ca3(PO4)2 composite with a chitosan coating was prepared to study its in vivo biodegradation properties. The chitosan dissolved in a 0.2% acetic acid solution was applied on the surface of Mg?6%Zn?10%Ca3(... A Mg?6%Zn?10%Ca3(PO4)2 composite with a chitosan coating was prepared to study its in vivo biodegradation properties. The chitosan dissolved in a 0.2% acetic acid solution was applied on the surface of Mg?6%Zn?10%Ca3(PO4)2 composite specimens and solidified at 60 °C for 30 min to form the coating. The cytotoxicity evaluation of chitosan coated specimens is at level 0, which indicates that such coating is safe for cellular applications. The in vivotests of chitosan coated composite show that the concentration of metal ions from the composite measured in the venous blood of Zelanian rabbits is less than that from the uncoated composite specimens. The chitosan coating impedes the in vivo degradation of the composite after surgery. The in vivo testing also indicates that the chitosan coated composite is harmless to important visceral organs, including the heart, kidneys and liver of the rabbits. The new bone formation surrounding the chitosan coated composite implant shows that the composite improves the concrescence of the bone tissues. And the chitosan coating is an effective corrosion resistant layer that reduces the hydrogen release of the implant composite, thereby decreasing the subcutaneous gas bubbles formed. 展开更多
关键词 biocompatibility magnesium composite CHITOSAN CYTOTOXICITY
在线阅读 下载PDF
In vitro corrosion and biocompatibility of phosphating modified WE43 magnesium alloy 被引量:5
14
作者 叶成红 奚廷斐 +2 位作者 郑玉峰 王淑琴 李扬德 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2013年第4期996-1001,共6页
Phospahting coated WE43 magnesium alloy was prepared by an immersion method. The microstructure, corrosion resistance and biocompatibility of the coated alloy were investigated. Scanning electron microscopy (SEM) an... Phospahting coated WE43 magnesium alloy was prepared by an immersion method. The microstructure, corrosion resistance and biocompatibility of the coated alloy were investigated. Scanning electron microscopy (SEM) and X-ray diffraction (XRD) were used to examine the microstructure and the composition of the coated alloy. The corrosion resistance was studied by means of potentiodynamic polarization method and the biocompatibility of the surface modified WE43 alloy was evaluated by (3-(4,5)-Dimethylthiazol-2, yl)-2,5-diphenyltetrazolium bromide (MTT) and hemolysis test. The results show that the phosphating coating can enhance the corrosion resistance of WE43 alloy and can be a good candidate to increase the biocompatibility of WE43 alloy. 展开更多
关键词 magnesium alloy phosphating coating corrosion resistance biocompatibility
在线阅读 下载PDF
Construction of TiO2/silane nanofilm on AZ31 magnesium alloy for controlled degradability and enhanced biocompatibility 被引量:11
15
作者 Lei Huang Kun Su +2 位作者 Yu-Feng Zheng Kelvin Wai-Kwok Yeung Xiang-Mei Liu 《Rare Metals》 SCIE EI CAS CSCD 2019年第6期588-600,共13页
A TiO2 nanofilm was prepared on the surface of AZ31 magnesium alloy with controllable thickness through atomic layer deposition(ALD) technique, which can adjust the corrosion behaviors of AZ31 Mg alloy.Compared with t... A TiO2 nanofilm was prepared on the surface of AZ31 magnesium alloy with controllable thickness through atomic layer deposition(ALD) technique, which can adjust the corrosion behaviors of AZ31 Mg alloy.Compared with the untreated Mg alloys, corrosion current densities(icorr)can decline by 58% in the 200-cycles TiO2-covered Mg alloy and further decline by up to 74% with the thickness of nanofilm up to 63 nm(400 cycles).The subsequent modification with a cross-linked conversion layer of 3-aminopropyltriethoxysilane(APTES) by a dipping method can produce a compact silane coating on TiO2 nanofilm, which can seal pinholes of TiO2 nanofilm and serve as a barrier to further adjust the corrosion behavior of the substrate.The icorrcan decline about two orders of magnitude in the TiO2/silane composite coating.Making the adjustable corrosion rate come true, which can be attributed to the precise control on the thickness of metal oxide nanofilm and additional protection from the compact silane coating.In vitro study discloses that the TiO2/silane hybrid coating shows higher expression of alkaline phosphatase(ALP)and can promote cellular adhesion and proliferation with better cytocompatibility than untreated Mg alloy. 展开更多
关键词 Magnesium alloy TiO2 biodegradability ATOMIC layer deposition Hybrid coating biocompatibility
原文传递
Study of the degradation behavior and the biocompatibility of Mg-0.8Ca alloy for orthopedic implant applications 被引量:11
16
作者 Aya Mohamed Ahmed MEl-Aziz Hans-Georg Breitinger 《Journal of Magnesium and Alloys》 SCIE EI CAS 2019年第2期249-257,共9页
Mg-Ca alloys have recently attracted great attention towards the research in the field of orthopedic biodegradable implants.This study presents an in vitro degradation assessment of Mg-0.8Ca(0.8 wt.%of Ca)alloy in Han... Mg-Ca alloys have recently attracted great attention towards the research in the field of orthopedic biodegradable implants.This study presents an in vitro degradation assessment of Mg-0.8Ca(0.8 wt.%of Ca)alloy in Hank’s balanced salt solution(HBSS).Immersion,hydrogen evolution and electrochemical behavior was studied as well as the cytotoxicity of the degradation products.Morphology and phase composition of the corrosion products were studied using SEM,EDX and XRD techniques.Degradation in HBSS resulted in the formation of the needle-shaped carbonated hydroxyapatite which was similar to the biological apatite in the human bone.Degradation kinetics showed that Mg-0.8Ca alloy had approximately 3-fold faster degradation rate than the pure Mg(1.08±0.38 mm/year for Mg-0.8Ca and 0.35±0.17 mm/year for pure Mg),as observed in two independent experiments.Both,pure Mg and Mg-0.8Ca alloy were biocompatible,generating no cytotoxic degradation products against human-derived HEK 293 cells.Thus,the Mg-0.8Ca alloy was found to be a promising biodegradable implant in terms of bioactivity and compatibility with human cell lines.Depending on the application of the implant and the estimated healing time of the bone,the desired degradation rate of an implant can be controlled by the Mg-Ca composition of such alloys. 展开更多
关键词 Mg-Ca alloys biodegradability Orthopedic implants biocompatibility TOXICITY HYDROXYAPATITE
在线阅读 下载PDF
Ozonation and Biodegradability of Lignin in Water 被引量:2
17
作者 李玉平 Gorenflo A Frimmel F H 《Journal of Beijing Institute of Technology》 EI CAS 2002年第3期290-294,共5页
To convert the non biodegradable sodium lignin sulfonate into biodegradable substances, the sodium lignin sulfonate in the water was ozonized and the pH value, dissolved organic carbon(DOC), ultraviolet absorbency at... To convert the non biodegradable sodium lignin sulfonate into biodegradable substances, the sodium lignin sulfonate in the water was ozonized and the pH value, dissolved organic carbon(DOC), ultraviolet absorbency at λ =254 nm(UVA) and the biodegradability of the ozonation effluent were measured. The non biodegradable sodium lignin sulfonate can be partly converted into biodegradable substances by ozonation (about 38 76%). In the ozonation process, there is little DOC decrease, but much UVA decrease and obvious pH drop. 展开更多
关键词 OZONATION biodegradability LIGNIN water treatment
在线阅读 下载PDF
In vivo degradability and biocompatibility of a rheo-formed Mg–Zn–Sr alloy for ureteral implantation 被引量:1
18
作者 Di Tie Renguo Guan +6 位作者 Huinan Liu Minfang Chen Sviatlana A.Ulasevich Ekaterina V.Skorb Patricia Holt-Torres Xiaopeng Lu Norbert Hort 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2022年第6期1631-1639,共9页
The introduction of biodegradable implant materials has significantly improved the postoperative subjective feelings of patients within the past few decades,among which magnesium alloy is widely considered a favorable... The introduction of biodegradable implant materials has significantly improved the postoperative subjective feelings of patients within the past few decades,among which magnesium alloy is widely considered a favorable choice as its appropriate biodegradability and evident antibacterial activity.Here,we reveal a semisolid rheo-formed Mg–Zn–Sr alloy ureteral implant that displayed suitable degradability and biocompatibility in a pig model.Refined non-dendritic microstructure was observed in the rheo-formed alloy,which led to ca.47%increase in ultimate tensile strength(from 195.0 MPa to 288.1 MPa)and more homogeneous degradation process compared with the untreated alloy.No post-interventional inflammation or pathological changes of the test animals were observed during the implantation period,and the corrosion rate(0.22±0.04 mm·y^(-1))perfectly fitted the clinical ureteral stent indwelling time.The urine bacteria numbers decreased from 88±13 CFU·mL^(-1)at 7 weeks post operation to 59±8 CFU·mL^(-1)at 14 weeks post operation,which confirmed the evident antibacterial activity of the alloy.Our study demonstrates that the Mg–Zn–Sr alloy is clinically safe for urinary system,enabling its efficacious use as ureteral implant materials. 展开更多
关键词 In vivo biodegradability biocompatibility Mg–Zn–Sr alloy Ureteral implant
在线阅读 下载PDF
Mechanical properties, biodegradability and cytocompatibility of biodegradable Mg-Zn-Zr-Nd/Y alloys 被引量:16
19
作者 Shi Jin Dan Zhang +4 位作者 Xiaopeng Lu Yang Zhang Lili Tan Ying Liu Qiang Wang 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2020年第12期190-201,共12页
Biodegradable magnesium alloys have been turned out to be a promising candidate for orthopedic applications.In this study,the mechanical properties,degradation behaviorand cytocompatibility of MgZn-Zr-Nd and Mg-Zn-Zr-... Biodegradable magnesium alloys have been turned out to be a promising candidate for orthopedic applications.In this study,the mechanical properties,degradation behaviorand cytocompatibility of MgZn-Zr-Nd and Mg-Zn-Zr-Y alloys were studied in comparison with pure Mg.Mechanical tests showed that the strength and ductility of Mg-Zn-Zr-Nd and Mg-Zn-Zr-Y alloys were excellent.The corrosion resistance analyzed by electrochemical test and immersion test in alpha modified eagle(α-MEM) medium with 10% fetal bovine serum(FBS) revealed the degradation of Mg-Zn-Zr-Nd and Mg-Zn-Zr-Y alloys were faster than pure Mg at an early stage but slowed down after long time immersion.The metal ion concentrations were consistent with the corrosion rate.Mg-Zn-Zr-Nd alloy shows better mechanical properties than pure Mg and better corrosion resistance than Mg-Zn-Zr-Y alloy.The direct and indirect in vitro tests with MC3 T3-E1 cells demonstrate that Mg-Zn-Zr-Nd shows the best cytocompatibility and osteogenesis.The results suggest that Mg-Zn-Zr-Nd alloy shows an ideal combination of mechanical,corrosive and biological properties.In summary,these results implying the Mg-Zn-Zr-Nd alloy has great potential to benefit the future development of orthopedic applications. 展开更多
关键词 Magnesium Mg-Zn-Zr-Nd alloy Mg-Zn-Zr-Y alloy Biodegradable implant biocompatibility
原文传递
Establishment of an untransfected human corneal epithelial cell line and its biocompatibility with denuded amniotic membrane 被引量:23
20
作者 Ting-Jun Fan Bin Xu +3 位作者 Jun Zhao Hong-Shou Yang Rui-Xin Wang and Xiu-Zhong Hu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第3期228-234,共7页
AIM: To establish an untransfected human corneal epithelial (HCEP) cell line and characterize its biocompatibility with denuded amniotic membrane (dAM). METHODS: The torn HCEP pieces were primarily cultured in DMEM/F1... AIM: To establish an untransfected human corneal epithelial (HCEP) cell line and characterize its biocompatibility with denuded amniotic membrane (dAM). METHODS: The torn HCEP pieces were primarily cultured in DMEM/F12 media (pH 7.2) supplemented with 20% fetal bovine serum and other necessary factors, yielding an HCEP cell line which was its growth performance, chromosome morphology, tumorigenicity and expression of marker proteins analyzed. In addition, the biocompatibility of HCEP cells with dAM was evaluated through histological and immunocytochemistry analyses and with light, electron and slit-lamp microscopies. RESULTS: HCEP cells proliferated to confluence in 3 weeks, which have been subcultured to passage 160. A continuous untransfected HCEP cell line, designated as utHCEPC01, was established with a population doubling time of 45.42 hours as was determined at passage 100. The cells retained HCEP cell properties as were approved by chromosomal morphology and the expression of keratin 3. They, with no tumorigenicity, formed a multilayer epithelium-like structure on dAMs through proliferation and differentiation during air-liquid interface culture, maintained expression of marker proteins including keratin 3 and integrin p 1 and attached tightly to dAMs. The reconstructed HCEP was highly transparent and morphologically and structurally similar to the original. CONCLUSION: An untransfected and non-tumorigenic HCEP cell line was established in this study. The cells maintained expression of marker proteins. The cell line was biocompatible with dAM. It holds the potential of being used for in vitro reconstruction of tissue-engineered HCEP, promising for the treatment of diseases caused by corneal epithelial disorders. 展开更多
关键词 human corneal epithelial cell cell line untransfected biocompatibility denuded amniotic membrane
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部