Surface Modification on Biodegradable Magnesium Alloys as Orthopedic Implant Materials to Improve the Bio-adaptability:A Review 被引量:25
1
作者 Peng Wan Lili Tan Ke Yang 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2016年第9期827-834,共8页
Magnesium (Mg) and its alloys as a novel kind of biodegradable material have attracted much funda- mental research and valuable exploration to develop its clinical application, Mg alloys degrade too fast at the earl... Magnesium (Mg) and its alloys as a novel kind of biodegradable material have attracted much funda- mental research and valuable exploration to develop its clinical application, Mg alloys degrade too fast at the early stage after implantation, thus commonly leading to some problems such as osteolysis, early fast mechanical loss, hydric bubble aggregation, gap formation between the implants and the tissue. Surface modification is one of the effective methods to control the degradation property of Mg alloys to adapt to the need of organism. Some coatings with bioactive elements have been developed, especially for the micro-arc oxidation coating, which has high adhesion strength and can be added with Ca, P, and Sr elements. Chemical deposition coating including bio-mimetic deposition coating, electro-deposition coating and chemical conversion coating can provide good anticorrosion property as well as better bioactivity with higher Ca and P content in the coating. From the biodegradation study, it can be seen that surface coating protected the Mg alloys at the early stage providing the Mg alloy substrate with lower degra-dation rate. The biocompatibility study showed that the surface modification could provide the cell and tissue stable and weak alkaline surface micro-environment adapting to the cell adhesion and tissue growth. The surface modification also decreased the mechanical loss at the early stage adapting to the load- bearing requirement at this stage. From the interface strength between Mg alloys implants and the surrounding tissue study, it can be seen that the surface modification improved the bio-adhesion of Mg alloys with the surrounding tissue, which is believed to be contributed to the tissue adaptability of the surface modification. Therefore, the surface modification adapts the biodegradable magnesium alloys to the need of hiodegradation, biocompatibility and mechanical loss property. For the different clinical application, different surface modification methods can be provided to adapt to the clinical requirements for the Mg alloy implants. 展开更多
关键词 bio-adaptability Coating Biodegradable Magnesium alloys Orthopedic implants
原文传递
Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel:A Review 被引量:14
2
作者 Jun Ma 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2016年第9期815-826,共12页
Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of... Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of biodegradable Mg alloy stents in the past decades. These exciting findings led us to propose the importance of the concept "bio-adaption" between the Mg alloy stent and the local tissue microenvironment after implantation. The healing responses of stented blood vessel can be generally described in three overlapping phases: inflammation, granulation and remodeling. The ideal bio-adaption of the Mg alloy stent, once implanted into the blood vessel, needs to be a reasonable function of the time and the space/dimension. First, a very slow degeneration of mechanical support is expected in the initial four months in order to provide sufficient mechanical support to the injured vessels. Although it is still arguable whether full mechanical support in stented lesions is mandatory during the first four months after implantation, it would certainly be a safety design parameter and a benchmark for regulatory evaluations based on the fact that there is insufficient human in vivo data available, especially the vessel wall mechanical properties during the healing/remodeling phase. Second, once the Mg alloy stent being degraded, the void space will be filled by the regenerated blood vessel tissues. The degradation of the Mg alloy stent should be 100% completed with no residues, and the degradation products (e.g., ions and hydrogen) will be helpful for the tissue reconstruction of the blood vessel. Toward this target, some future research perspectives are also discussed. 展开更多
关键词 Mg stent bio-adaptation Vessel Wound healing
原文传递
Formation and Bioactivity of SrTiO_3 Nanotubes on Titanium by Modified Anodization and Hydrothermal Treatment
3
作者 Yanni Zhang Yong Han Lan Zhang 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2016年第9期930-936,共7页
SrTiO3 nanotube films with good adhesion strengths to Ti substrates were fabricated by using a hybrid approach with a modified anodization and a hydrothermal treatment (HT). The effect of Sr^2+ concentration in HT ... SrTiO3 nanotube films with good adhesion strengths to Ti substrates were fabricated by using a hybrid approach with a modified anodization and a hydrothermal treatment (HT). The effect of Sr^2+ concentration in HT solutions on the morphologies and phase components of the nanotubes were investigated, the SrTiO3 nanotubes formation mechanism was explored, and the adhesion strengths, hydrophilicity and apatite-forming ability of the SrTiO3 nanotubes were also evaluated. The results demonstrated that with increasing the incorporation of Sr^2+ into the nanotubes, no obvious changes of the lengths and outer diameters of the nanotubes were observed, but the wall thickness and the crystallinity of SrTiO3 in the nanotubes increased. The accumulation of Sr at the inner tube wall indicated that the reaction of Sr^2+ with TiO2 mainly occurred in the vicinity of internal surfaces of the closely arranged nanotubes. The formation of the SrTiO3 nanotubes could be attributed to an in situ dissolution-recrystallization process. The SrTiO3 nanotubes exhibited good hydrophilicity and bioactivity, and the induced apatite preferred to nucleate on the nanotubes with higher crystallinity and Sr content, indicating a good hio-adaptability of the SrTiO3 nanotubes for orthopedic application. 展开更多
关键词 SrTiO3 nanotubes Modified anodization Hydrothermal treatment bio-adaptability
原文传递
Zn and Ag Co-doped Anti-microbial TiO_2 Coatings on Ti by Micro-arc Oxidation 被引量:10
4
作者 Lan Zhang Qin Gao Yong Han 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2016年第9期919-924,共6页
Micro-porous TiO2 coatings co-doped with Zn^2+ and Ag nanoparticles were fabricated on Ti by microarc oxidation (MAO) for 0.5, 1.5, 2 and 4 min, respectively. The evolutions of morphology and phase component of the... Micro-porous TiO2 coatings co-doped with Zn^2+ and Ag nanoparticles were fabricated on Ti by microarc oxidation (MAO) for 0.5, 1.5, 2 and 4 min, respectively. The evolutions of morphology and phase component of the coating as a function of processing time were investigated. The microstructure of the 2 min treated coating was further observed by transmission electron microscopy to explore the coating formation mechanism. The amounts of Ag and Zn released from the 2 min treated coating were measured and the antibacterial properties of the coatings against Staphylococcus aureus (S. aureus) were also investigated. The obtained results showed that with prolonged MAO time, the contents of Ag and Zn on the coating surfaces increased. All the coatings were micro-porous with pore diameters of 1 -4μm; however, some pores were blocked by deposits on the 4 min treated coating. The 2 rain treated coating was composed of amorphous TiO2, anatase, futile, ZnO, Zn2TiO4 and homogenously distributed Ag nanoparticles. After immersion, Zn^2+, Ag^+, Ti^2+ and Ca^2+ were released from the coating and with the immersion time prolonged, the accumulated concentrations of these ions increased. After immersion for 36 weeks, the accumulated Zn2. and Ag^+ concentrations were 6.88 and 0.684 ppm, respectively, which are higher than the minimal inhibitory concentration but much lower than the cytotoxic concentration. Compared with polished Ti control, the coatings co-doped with Zn^2+ and Ag nanoparticles significantly inhibited the ad- hesions of S. uureus and reduced the amounts of planktonic bacteria in culture medium, indicating that the Zn and Ag co-doped TiO2 could be a bio-adaptable coating for long-lasting anti-microbial performance. 展开更多
关键词 Zn Ag nanoparticle Co-doped TiO2 Micro-arc oxidation bio-adaptable
原文传递
Opposite Regulation of Chondrogenesis and Angiogenesis in Cartilage Repair ECM Materials under Hypoxia 被引量:1
5
作者 Shaoming Chen Manman Gao +9 位作者 Zhiyu Zhou Jiabi Liang Ming Gong Xuejun Dai Tangzhao Liang Jiacheng Ye Gang Wu Lijin Zou Yingjun Wang Xuenong Zou 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2016年第9期978-985,共8页
Although cartilage tissue engineering has been developed for decades, it is still unclear whether angio- genesis was the accompaniment of chondrogenesis in cartilage regeneration. This study aimed to explore the proce... Although cartilage tissue engineering has been developed for decades, it is still unclear whether angio- genesis was the accompaniment of chondrogenesis in cartilage regeneration. This study aimed to explore the process of anti-angiogenesis during cartilage regenerative progress in cartilage repair extracellular matrix (ECM) materials under Hypoxia. C3H10T1/2 cell line, seeded as pellet or in ECM materials, was added with chondrogenic medium or DMEM medium for 21 days under hypoxia or normoxia environment. Genes and miRNAs related with chondrogenesis and angiogenesis were detected by RT-qPCR technique on Days 7, 14, and 21. Dual-luciferase report system was used to explore the regulating roles of miRNAs on angiogenesis. Results showed that the chondrogenic medium promotes chondrogenesis both in pellet and ECM materials culture. HIF1α was up-regulated under hypoxia compared with normoxia (P 〈 0.05). Meanwhile, hypoxia enhanced chondrogenesis, miR-140-Sp exhibited higher expression while miR-146b exhibited lower expression. The chondrogenic phenotype was more stabilized in the ECM materials in chondrogenic medium than DMEM medium, with lower VEGFα expression even under hypoxia. Dual-luciferase report assays demonstrated that miR-140-5p directly targets VEGFct by binding its 3'- UTR. Taken together, chondrogenic cytokines, ECM materials and hypoxia synergistically promoted chondrogenesis and inhibited angiogenesis, miR-140-5p olaved an imnortant role in this process. 展开更多