This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper cons...This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.展开更多
β-Ga_(2)O_(3) MOS inverter should play a crucial role in β-Ga_(2)O_(3) electronic circuits. Enhancement-mode(E-mode) MOSFET was fabricated based on β-Ga_(2)O_(3) film grown by atomic layer deposition technology, an...β-Ga_(2)O_(3) MOS inverter should play a crucial role in β-Ga_(2)O_(3) electronic circuits. Enhancement-mode(E-mode) MOSFET was fabricated based on β-Ga_(2)O_(3) film grown by atomic layer deposition technology, and the β-Ga_(2)O_(3) inverter was further monolithically integrated on this basis. The β-Ga_(2)O_(3) n MOSFET exhibits excellent electrical characteristics with an on/off current ratio reaching 10^(5). The logic inverter shows outstanding voltage inversion characteristics under low-frequency from 1 to 400 Hz operation. As the frequency continues to increase to 10 K, the reverse characteristic becomes worse due to parasitic capacitance induced by processes, and the difference between the highest and lowest values of VOUT has an exponential decay relationship with the frequency. This paper provides the practice for the development of β-Ga_(2)O_(3)-based circuits.展开更多
Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressi...Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressing these shortcomings,thiswork presents a robust 15-level PackedUCell(PUC)inverter topology designed for renewable energy and grid-connected applications.The proposed systemintegrates a sensor less proportional-resonant(PR)controller with an advanced carrier-based pulse width modulation scheme.This approach efficiently balances capacitor voltage,minimizes steady-state error,and strongly suppresses both zero and third-order harmonics resulting in reduced total harmonic distortion and enhanced voltage regulation.Additionally,a novel switching algorithm simplifies the design and implementation,further lowering voltage stress across switches.Extensive simulation results validate the performance under various resistive and resistive-inductive load conditions,demonstrating compliance with IEEE-519 THD standards and robust operation under dynamic changes.The proposed sensorless PR-controlled 15-PUC inverter thus offers a compelling,cost-effective solution for efficient power conversion in next-generation renewable energy systems.展开更多
Complementary inverter is the basic unit for logic circuits,but the inverters based on full oxide thin-film transistors(TFTs)are still very limited.The next challenge is to realize complementary inverters using homoge...Complementary inverter is the basic unit for logic circuits,but the inverters based on full oxide thin-film transistors(TFTs)are still very limited.The next challenge is to realize complementary inverters using homogeneous oxide semiconduc-tors.Herein,we propose the design of complementary inverter based on full ZnO TFTs.Li-N dual-doped ZnO(ZnO:(Li,N))acts as the p-type channel and Al-doped ZnO(ZnO:Al)serves as the n-type channel for fabrication of TFTs,and then the complemen-tary inverter is produced with p-and n-type ZnO TFTs.The homogeneous ZnO-based complementary inverter has typical volt-age transfer characteristics with the voltage gain of 13.34 at the supply voltage of 40 V.This work may open the door for the development of oxide complementary inverters for logic circuits.展开更多
With the development of high-frequency and highvoltagetraction machines(TM)incorporating hairpin windings(HW)and SiC inverters for electric vehicles(EV),both theinterturn voltage stress and temperature within HW are r...With the development of high-frequency and highvoltagetraction machines(TM)incorporating hairpin windings(HW)and SiC inverters for electric vehicles(EV),both theinterturn voltage stress and temperature within HW are rising,increasing the risk of partial discharge(PD),and presentingsignificant challenges to insulation safety.Therefore,this paperaddresses this issue and proposes potential solutions.Firstly,thepaper examines an 8-pole,48-slot,6-layer HW TM to highlightthe unique characteristics of this winding structure,and explainsthe uneven distribution of interturn voltage stress andtemperature.Subsequently,a high-frequency equivalent circuitmodel of the HW TM prototype is developed.The error ofsimulation and experiment is only 5.7%,which proves theaccuracy of the model.Then,an improved HW scheme isproposed to lower the maximum voltage stress by 29.3%.Furthermore,the temperature distribution of HW TM isanalyzed to facilitate a detailed examination of the impact oftemperature on insulation PD.Finally,the partial dischargeinception voltage(PDIV)of interturn insulation,consideringtemperature effects,is calculated and verified throughexperiment.The paper proposes a reliability-oriented designmethod and process for HW TM.It demonstrates that thereliability-oriented design can achieve PD-free performance inthe design stage of HW.展开更多
To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which rel...To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which relies on manual experience to set parameters(e.g.,noise tolerance,penalty parameter,number of decompositions),this paper achieves adaptive optimization of parameters through MPA algorithmto avoid the problemof feature information loss caused by manual parameter tuning,and adopts the improved VMD algorithm for feature extraction of DC-side voltage data signals of PV-grid-connected inverters;and then,adopts the PSO algorithm for theThen,the PSO algorithm is used to optimize the optimal batch size,the number of nodes in the hidden layer and the learning rate of the BiLSTM network,which significantly improves the model’s ability to capture the long-term dependent features of the PV inverter’s timing signals,to construct the PV grid-connected inverter prediction model of PSO-BiLSTM,and predict the capacitance value of the PVgrid-connected inverter.Finally,diagnostic experiments are carried out based on the expected capacitance value and the capacitance failure criterion.The results showthat compared with the traditional VMD algorithm,the MPA-optimised VMD improves the signal-to-noise ratio(SNR)of the signal decomposition from 28.5 to 33.2 dB(16.5%improvement).After combining with the PSO-BiLSTM model,the mean absolute percentage error(MAPE)of the fault diagnosis is reduced to 1.31%,and the coefficient of determination(R2)is up to 0.99.It is concluded that the present method has excellent diagnostic performance of PV grid-connected inverter data signals and effectively improves the accuracy of PV grid-connected inverter diagnosis.展开更多
Uneven power distribution,transient voltage,and frequency deviations are observed in the photovoltaic storage hybrid inverter during the switching between grid-connected and island modes.In response to these issues,th...Uneven power distribution,transient voltage,and frequency deviations are observed in the photovoltaic storage hybrid inverter during the switching between grid-connected and island modes.In response to these issues,this paper proposes a grid-connected/island switching control strategy for photovoltaic storage hybrid inverters based on the modified chimpanzee optimization algorithm.The proposed strategy incorporates coupling compensation and power differentiation elements based on the traditional droop control.Then,it combines the angular frequency and voltage amplitude adjustments provided by the phase-locked loop-free pre-synchronization control strategy.Precise pre-synchronization is achieved by regulating the virtual current to zero and aligning the photovoltaic storage hybrid inverter with the grid voltage.Additionally,two novel operators,learning and emotional behaviors are introduced to enhance the optimization precision of the chimpanzee algorithm.These operators ensure high-precision and high-reliability optimization of the droop control parameters for photovoltaic storage hybrid inverters.A Simulink model was constructed for simulation analysis,which validated the optimized control strategy’s ability to evenly distribute power under load transients.This strategy effectively mitigated transient voltage and current surges during mode transitions.Consequently,seamless and efficient switching between gridconnected and island modes was achieved for the photovoltaic storage hybrid inverter.The enhanced energy utilization efficiency,in turn,offers robust technical support for grid stability.展开更多
The emergence of SARS-CoV-2 variants and drug-resistant mutants emphasizes the urgent need to develop novel antiviral agents.In the present study,we examined the therapeutic effect of the Chinese medicinal herb,Scutel...The emergence of SARS-CoV-2 variants and drug-resistant mutants emphasizes the urgent need to develop novel antiviral agents.In the present study,we examined the therapeutic effect of the Chinese medicinal herb,Scutellaria barbata D.Don(SBD),against SARS-CoV-2 infection both in vitro and in vivo.Using a viral replicon particle(VRP)-based mouse model of SARS-CoV-2 infection,our study revealed that SBD extracts can reduce viral load in mouse lungs and alleviate the viral induced pneumonia.In vitro antiviral determination further validated the direct acting antiviral efficacy of SBD extracts against SARS-CoV-2 replication.Mechanistic studies demonstrated that SBD can act against SARS-CoV2 replication by targeting both 3-chymotrypsin-like and papain-like cysteine proteases,via a combination of multiple active constituents.Moreover,SBD can modulate the host inflammation response in a bi-directional manner,which also contribute to the mitigation of viral induced acute lung injury.In summary,our study provides SBD as a promising therapeutic agent to combat SARS-CoV-2 infections that merit further development.展开更多
With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered wide...With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered widespread attention.To address the challenges of fault feature extraction,this article proposes an end-to-end diagnostic approach based on a wavelet kernel convolutional neural network (WKCNN),capable of extracting multi-scale features from current signals to significantly enhance diagnostic accuracy.This method directly uses raw three-phase current signals as input,applying wavelet kernel convolution to automatically capture frequency-domain fault features,combined with a Softmax classifier optimized by the Adam algorithm to achieve fault diagnosis for NPC threelevel inverters.Experimental results under various operating conditions demonstrate that this approach maintains robust diagnostic accuracy across multiple fault scenarios,with comparative analysis further confirming its advantages in diagnostic efficiency and performance over traditional machine learning and other deep learning methods.展开更多
Three-phase grid-connected inverters(GCIs)are essential components in distributed generation systems,where the accuracy of current measurement circuits is fundamental for reliable closed-loop operation.Nevertheless,th...Three-phase grid-connected inverters(GCIs)are essential components in distributed generation systems,where the accuracy of current measurement circuits is fundamental for reliable closed-loop operation.Nevertheless,the presence of a DC offset in the measured current can disrupt the regulation of grid currents and significantly degrade system performance.In this work,a fault-tolerant control approach is introduced to counteract the impact of such offset faults through a dedicated current compensation mechanism.The proposed solution is built around two main stages:(i)detecting and isolating DC offset faults that may appear in one or multiple phases of the measured grid currents,and(ii)estimating the fault magnitude and reconstructing the corrected current signal.The offset magnitude is obtained analytically by examining the grid current projected onto the synchronous d-axis at the grid angular frequency,eliminating the need for any additional sensing hardware.Simulation and experimental investigations conducted under several fault scenarios confirm the robustness of the proposed strategy and highlight significant improvements in detection speed and diagnostic accuracy.展开更多
The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interl...The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices.展开更多
Interconnection planning involving bi-directional converters(BdCs)is crucial for enhancing the reliability and robustness of hybrid alternating current(AC)/direct current(DC)microgrid clusters with high penetrations o...Interconnection planning involving bi-directional converters(BdCs)is crucial for enhancing the reliability and robustness of hybrid alternating current(AC)/direct current(DC)microgrid clusters with high penetrations of renewable energy resources(RESs).However,challenges such as the non-convex nature of BdC efficiency and renewable energy uncertainty complicate the planning process.To address these issues,this paper proposes a tri-level BdC-based planning framework that incorporates dynamic BdC efficiency and a data-correlated uncertainty set(DcUS)derived from historical data patterns.The proposed framework employs a least-squares approximation to linearize BdC efficiency and constructs the DcUS to balance computational efficiency and solution robustness.Additionally,a fully parallel column and constraint generation algorithm is developed to solve the model efficiently.Numerical simulations on a practical hybrid AC/DC microgrid system demonstrate that the proposed method reduces interconnection costs by up to 21.8%compared to conventional uncertainty sets while ensuring robust operation under all considered scenarios.These results highlight the computational efficiency,robustness,and practicality of the proposed approach,making it a promising solution for modern power systems.展开更多
The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to e...The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to external conditions such as PV panel shading,PV component damage,can lead to PV output power imbalance,triggering the system over-modulation phenomenon,which in turn leads to grid-connected current waveform distortion.To this end,an improved power balance control strategy is proposed in this paper.Firstly,according to the different modulation ratios of each H-bridge module,a suitable harmonic injection method is used to keep the peak value of the modulating waveform always at 1;then an inverse triangular trapezoidal waveform is injected to optimize the modulating waveform,which further improves the output voltage waveform,reduces the THD value of the grid-connected currents,and maintains the stability of power inside the CHB system.Purpose.Simulation verifies the effectiveness and feasibility of this power balance control strategy.展开更多
Molecular tailoring of self-assembled hole-transporting monolayers(SAMs)has been proven as an efficient approach for improving the device performance of inverted perovskite solar cells.Herein,a novel SAM with extended...Molecular tailoring of self-assembled hole-transporting monolayers(SAMs)has been proven as an efficient approach for improving the device performance of inverted perovskite solar cells.Herein,a novel SAM with extended conjugation is designed and synthesized,named NaPh-4PACz.Compared to Ph-4PACz,NaPh-4PACz exhibits a larger adsorption energy with the ITO substrate,enabling the formation of a more uniform and dense film,thereby preventing direct contact between the perovskite and ITO.Additionally,NaPh-4PACz also has a stronger interaction with the perovskite,which can reduce buried interface defects and suppress non-radiative recombination.Consequently,NaPh-4PACz-based devices achieved a power conversion efficiency of 25.48%due to their interfacial“adhesive”ability.Importantly,the stability of the NaPh-4PACz-based devices was significantly improved.展开更多
Objective: To investigate the role of collagen IV and PAS positive substancesecreted by tumor cells in vasculogenic mimicry (VM) and the effects of VM on tumor cells expressingVEGF. Methods: 158 cases of bi-direction ...Objective: To investigate the role of collagen IV and PAS positive substancesecreted by tumor cells in vasculogenic mimicry (VM) and the effects of VM on tumor cells expressingVEGF. Methods: 158 cases of bi-direction differential malignant tumor specimens withparaffin-embedded were enrolled into our study and made tissue microarray which were dual-stainedwith CD31-PAS and stained with collagen IV. The difference of the areas and distribution withpattern surrounded by between CD31 and PAS positive respectively were identified via grid-counting,as well as the difference of VEGF expression with VE absent and present. Results: The basementmembrane of VM was both PAS and collagen IV positive. VEGF expression in the bi-directiondifferential malignant tumor was higher VM-absent than VM-present and the difference wasstatistically significance in malignant melanoma and alveolar rhabdomyosarcoma (P 【 0.05).Conclusion: PAS positive substance and collagen IV compose the wall of VE and VE could provide theoxygen and nutrition for tumor growth and progression.展开更多
A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI imple...A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters.展开更多
The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inve...The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inverter is comprised of a combined Buck/Boost DC/DC converter and a bridge circuit. The front stage converter is controlled to output variable DC voltage and the bridge circuit is used to convert the DC voltage to AC output. The energy feedback technology and one circle control scheme are used t...展开更多
The pulse width modulation (PWM) scheme is used in the staircase waveform inverters. The control strategy and system characteristics are analyzed. While the single pulse width modulation is used, the 12 stairs wavefo...The pulse width modulation (PWM) scheme is used in the staircase waveform inverters. The control strategy and system characteristics are analyzed. While the single pulse width modulation is used, the 12 stairs waveform inverter can achieve the output voltage regulated in a wide range of input voltage as well as the perfect output waveform. A 1 500 V input 80 kVA inverter has been deve loped. Experiments of the 80kVA inverter resulted in that the scheme is a perfect method for the development of high power converters with high efficiency.展开更多
DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the pa...DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the parallel inverter system without output isolation transformers, the difference of DC components of the output voltage can cause large DC loop-current among modular inverters. Aiming at this problem, this paper studies several DC loop-current detecting and restraining methods. By digital adjustment with high precision on the DC components of reference sine wave, the DC components of inverter′s output voltage can be adjusted to restrain DC loop-current. Experimental results prove that the DC loop-current detecting and restraining methods have a good performance.展开更多
基金Supported by the Fundamental Research Funds for the Central Universities(2024ZYGXZR047)the National Natural Science Foundation of China(62373156)the Guangdong Basic and Applied Basic Research Foundation(2024A1515011736)。
文摘This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.
基金supported by Natural Science Basic Research Program of Shaanxi Province of China (No. 2023-JC-YB-574)National Natural Science Foundation of China (No. 62304178)。
文摘β-Ga_(2)O_(3) MOS inverter should play a crucial role in β-Ga_(2)O_(3) electronic circuits. Enhancement-mode(E-mode) MOSFET was fabricated based on β-Ga_(2)O_(3) film grown by atomic layer deposition technology, and the β-Ga_(2)O_(3) inverter was further monolithically integrated on this basis. The β-Ga_(2)O_(3) n MOSFET exhibits excellent electrical characteristics with an on/off current ratio reaching 10^(5). The logic inverter shows outstanding voltage inversion characteristics under low-frequency from 1 to 400 Hz operation. As the frequency continues to increase to 10 K, the reverse characteristic becomes worse due to parasitic capacitance induced by processes, and the difference between the highest and lowest values of VOUT has an exponential decay relationship with the frequency. This paper provides the practice for the development of β-Ga_(2)O_(3)-based circuits.
文摘Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressing these shortcomings,thiswork presents a robust 15-level PackedUCell(PUC)inverter topology designed for renewable energy and grid-connected applications.The proposed systemintegrates a sensor less proportional-resonant(PR)controller with an advanced carrier-based pulse width modulation scheme.This approach efficiently balances capacitor voltage,minimizes steady-state error,and strongly suppresses both zero and third-order harmonics resulting in reduced total harmonic distortion and enhanced voltage regulation.Additionally,a novel switching algorithm simplifies the design and implementation,further lowering voltage stress across switches.Extensive simulation results validate the performance under various resistive and resistive-inductive load conditions,demonstrating compliance with IEEE-519 THD standards and robust operation under dynamic changes.The proposed sensorless PR-controlled 15-PUC inverter thus offers a compelling,cost-effective solution for efficient power conversion in next-generation renewable energy systems.
基金supported by Zhejiang Provincial Natural Science Foundation of China(No.LZ24E020001).
文摘Complementary inverter is the basic unit for logic circuits,but the inverters based on full oxide thin-film transistors(TFTs)are still very limited.The next challenge is to realize complementary inverters using homogeneous oxide semiconduc-tors.Herein,we propose the design of complementary inverter based on full ZnO TFTs.Li-N dual-doped ZnO(ZnO:(Li,N))acts as the p-type channel and Al-doped ZnO(ZnO:Al)serves as the n-type channel for fabrication of TFTs,and then the complemen-tary inverter is produced with p-and n-type ZnO TFTs.The homogeneous ZnO-based complementary inverter has typical volt-age transfer characteristics with the voltage gain of 13.34 at the supply voltage of 40 V.This work may open the door for the development of oxide complementary inverters for logic circuits.
基金supported by the Project of National Natural Science Foundation of China under Grant 52407060 and 52422704supported by Liaoning Province science and technology plan doctoral project under Grant 2023-BSBA-255.
文摘With the development of high-frequency and highvoltagetraction machines(TM)incorporating hairpin windings(HW)and SiC inverters for electric vehicles(EV),both theinterturn voltage stress and temperature within HW are rising,increasing the risk of partial discharge(PD),and presentingsignificant challenges to insulation safety.Therefore,this paperaddresses this issue and proposes potential solutions.Firstly,thepaper examines an 8-pole,48-slot,6-layer HW TM to highlightthe unique characteristics of this winding structure,and explainsthe uneven distribution of interturn voltage stress andtemperature.Subsequently,a high-frequency equivalent circuitmodel of the HW TM prototype is developed.The error ofsimulation and experiment is only 5.7%,which proves theaccuracy of the model.Then,an improved HW scheme isproposed to lower the maximum voltage stress by 29.3%.Furthermore,the temperature distribution of HW TM isanalyzed to facilitate a detailed examination of the impact oftemperature on insulation PD.Finally,the partial dischargeinception voltage(PDIV)of interturn insulation,consideringtemperature effects,is calculated and verified throughexperiment.The paper proposes a reliability-oriented designmethod and process for HW TM.It demonstrates that thereliability-oriented design can achieve PD-free performance inthe design stage of HW.
基金supported by Science and Technology Projects of Jiangsu Province(No.BE2022003)Science and Technology Projects of Jiangsu Province(No.BE2022003-5).
文摘To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which relies on manual experience to set parameters(e.g.,noise tolerance,penalty parameter,number of decompositions),this paper achieves adaptive optimization of parameters through MPA algorithmto avoid the problemof feature information loss caused by manual parameter tuning,and adopts the improved VMD algorithm for feature extraction of DC-side voltage data signals of PV-grid-connected inverters;and then,adopts the PSO algorithm for theThen,the PSO algorithm is used to optimize the optimal batch size,the number of nodes in the hidden layer and the learning rate of the BiLSTM network,which significantly improves the model’s ability to capture the long-term dependent features of the PV inverter’s timing signals,to construct the PV grid-connected inverter prediction model of PSO-BiLSTM,and predict the capacitance value of the PVgrid-connected inverter.Finally,diagnostic experiments are carried out based on the expected capacitance value and the capacitance failure criterion.The results showthat compared with the traditional VMD algorithm,the MPA-optimised VMD improves the signal-to-noise ratio(SNR)of the signal decomposition from 28.5 to 33.2 dB(16.5%improvement).After combining with the PSO-BiLSTM model,the mean absolute percentage error(MAPE)of the fault diagnosis is reduced to 1.31%,and the coefficient of determination(R2)is up to 0.99.It is concluded that the present method has excellent diagnostic performance of PV grid-connected inverter data signals and effectively improves the accuracy of PV grid-connected inverter diagnosis.
基金received funding from the Postgraduate Research&Practice Innovation Program of Jiangsu Province(SJCX23_1633)2023 University Student Innovation and Entrepreneurship Training Program(202311463009Z)+1 种基金Changzhou Science and Technology Support Project(CE20235045)Open Project of Jiangsu Key Laboratory of Power Transmission&Distribution Equipment Technology(2021JSSPD12).
文摘Uneven power distribution,transient voltage,and frequency deviations are observed in the photovoltaic storage hybrid inverter during the switching between grid-connected and island modes.In response to these issues,this paper proposes a grid-connected/island switching control strategy for photovoltaic storage hybrid inverters based on the modified chimpanzee optimization algorithm.The proposed strategy incorporates coupling compensation and power differentiation elements based on the traditional droop control.Then,it combines the angular frequency and voltage amplitude adjustments provided by the phase-locked loop-free pre-synchronization control strategy.Precise pre-synchronization is achieved by regulating the virtual current to zero and aligning the photovoltaic storage hybrid inverter with the grid voltage.Additionally,two novel operators,learning and emotional behaviors are introduced to enhance the optimization precision of the chimpanzee algorithm.These operators ensure high-precision and high-reliability optimization of the droop control parameters for photovoltaic storage hybrid inverters.A Simulink model was constructed for simulation analysis,which validated the optimized control strategy’s ability to evenly distribute power under load transients.This strategy effectively mitigated transient voltage and current surges during mode transitions.Consequently,seamless and efficient switching between gridconnected and island modes was achieved for the photovoltaic storage hybrid inverter.The enhanced energy utilization efficiency,in turn,offers robust technical support for grid stability.
基金supported by the National Natural Science Foundation of China(82274204 and 82104134)the Natural Science Foundation of Shandong Province,China(ZR2024QH110)+1 种基金the Major Basic Program of Shandong Natural Science Foundation,China(ZR2021ZD17)the Project of Youth Innovation Team of Shandong Province(2022KJ254).
文摘The emergence of SARS-CoV-2 variants and drug-resistant mutants emphasizes the urgent need to develop novel antiviral agents.In the present study,we examined the therapeutic effect of the Chinese medicinal herb,Scutellaria barbata D.Don(SBD),against SARS-CoV-2 infection both in vitro and in vivo.Using a viral replicon particle(VRP)-based mouse model of SARS-CoV-2 infection,our study revealed that SBD extracts can reduce viral load in mouse lungs and alleviate the viral induced pneumonia.In vitro antiviral determination further validated the direct acting antiviral efficacy of SBD extracts against SARS-CoV-2 replication.Mechanistic studies demonstrated that SBD can act against SARS-CoV2 replication by targeting both 3-chymotrypsin-like and papain-like cysteine proteases,via a combination of multiple active constituents.Moreover,SBD can modulate the host inflammation response in a bi-directional manner,which also contribute to the mitigation of viral induced acute lung injury.In summary,our study provides SBD as a promising therapeutic agent to combat SARS-CoV-2 infections that merit further development.
基金supported in part by Zhejiang Provincial“Pioneer”and“Leading Goose”R&D Program of China under Grant 2024C01014the National Natural Science Foundation of China under Grant52177055。
文摘With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered widespread attention.To address the challenges of fault feature extraction,this article proposes an end-to-end diagnostic approach based on a wavelet kernel convolutional neural network (WKCNN),capable of extracting multi-scale features from current signals to significantly enhance diagnostic accuracy.This method directly uses raw three-phase current signals as input,applying wavelet kernel convolution to automatically capture frequency-domain fault features,combined with a Softmax classifier optimized by the Adam algorithm to achieve fault diagnosis for NPC threelevel inverters.Experimental results under various operating conditions demonstrate that this approach maintains robust diagnostic accuracy across multiple fault scenarios,with comparative analysis further confirming its advantages in diagnostic efficiency and performance over traditional machine learning and other deep learning methods.
文摘Three-phase grid-connected inverters(GCIs)are essential components in distributed generation systems,where the accuracy of current measurement circuits is fundamental for reliable closed-loop operation.Nevertheless,the presence of a DC offset in the measured current can disrupt the regulation of grid currents and significantly degrade system performance.In this work,a fault-tolerant control approach is introduced to counteract the impact of such offset faults through a dedicated current compensation mechanism.The proposed solution is built around two main stages:(i)detecting and isolating DC offset faults that may appear in one or multiple phases of the measured grid currents,and(ii)estimating the fault magnitude and reconstructing the corrected current signal.The offset magnitude is obtained analytically by examining the grid current projected onto the synchronous d-axis at the grid angular frequency,eliminating the need for any additional sensing hardware.Simulation and experimental investigations conducted under several fault scenarios confirm the robustness of the proposed strategy and highlight significant improvements in detection speed and diagnostic accuracy.
基金supported by the National Natural Science Foundation of China(Grant No.51977046)Wuxi University Research Start-up Fund for Introduced Talent(2022r021).
文摘The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices.
基金supported by the National Natural Science Foundation of China(72271213)the Shenzhen Science and Technology Program(JCYJ20220530143800001 and RCYX20221008092927070)+1 种基金the Guangdong Basic and Applied Basic Research Foundation(2024A1515240024)the National Key Research and Development Program of China(2022YFB2403500).
文摘Interconnection planning involving bi-directional converters(BdCs)is crucial for enhancing the reliability and robustness of hybrid alternating current(AC)/direct current(DC)microgrid clusters with high penetrations of renewable energy resources(RESs).However,challenges such as the non-convex nature of BdC efficiency and renewable energy uncertainty complicate the planning process.To address these issues,this paper proposes a tri-level BdC-based planning framework that incorporates dynamic BdC efficiency and a data-correlated uncertainty set(DcUS)derived from historical data patterns.The proposed framework employs a least-squares approximation to linearize BdC efficiency and constructs the DcUS to balance computational efficiency and solution robustness.Additionally,a fully parallel column and constraint generation algorithm is developed to solve the model efficiently.Numerical simulations on a practical hybrid AC/DC microgrid system demonstrate that the proposed method reduces interconnection costs by up to 21.8%compared to conventional uncertainty sets while ensuring robust operation under all considered scenarios.These results highlight the computational efficiency,robustness,and practicality of the proposed approach,making it a promising solution for modern power systems.
基金supported by the National Natural Science Foundation of China,Regional Science Foundation Project,52367009,Study on Bow Net Dynamics Modeling and Coupling Smoothness of High speed AC Rigid Network in the Long Tunnel Section of Sichuan Tibet Railway.
文摘The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to external conditions such as PV panel shading,PV component damage,can lead to PV output power imbalance,triggering the system over-modulation phenomenon,which in turn leads to grid-connected current waveform distortion.To this end,an improved power balance control strategy is proposed in this paper.Firstly,according to the different modulation ratios of each H-bridge module,a suitable harmonic injection method is used to keep the peak value of the modulating waveform always at 1;then an inverse triangular trapezoidal waveform is injected to optimize the modulating waveform,which further improves the output voltage waveform,reduces the THD value of the grid-connected currents,and maintains the stability of power inside the CHB system.Purpose.Simulation verifies the effectiveness and feasibility of this power balance control strategy.
基金supported by the National Natural Science Foundation of China(61904053,22279033)the National Key Research and Development Program of China(2023YFB4204502)+2 种基金the 111 Project(B16016)the Fundamental Research Funds for the Central Universities(2025MS043)the Special Foundation for Carbon Peak Carbon Neutralization Technology Innovation Program of Jiangsu Province(BE2022026).
文摘Molecular tailoring of self-assembled hole-transporting monolayers(SAMs)has been proven as an efficient approach for improving the device performance of inverted perovskite solar cells.Herein,a novel SAM with extended conjugation is designed and synthesized,named NaPh-4PACz.Compared to Ph-4PACz,NaPh-4PACz exhibits a larger adsorption energy with the ITO substrate,enabling the formation of a more uniform and dense film,thereby preventing direct contact between the perovskite and ITO.Additionally,NaPh-4PACz also has a stronger interaction with the perovskite,which can reduce buried interface defects and suppress non-radiative recombination.Consequently,NaPh-4PACz-based devices achieved a power conversion efficiency of 25.48%due to their interfacial“adhesive”ability.Importantly,the stability of the NaPh-4PACz-based devices was significantly improved.
基金This work was partially supported by a grant from the National Natural Science Foundation of China (No. 30370378)
文摘Objective: To investigate the role of collagen IV and PAS positive substancesecreted by tumor cells in vasculogenic mimicry (VM) and the effects of VM on tumor cells expressingVEGF. Methods: 158 cases of bi-direction differential malignant tumor specimens withparaffin-embedded were enrolled into our study and made tissue microarray which were dual-stainedwith CD31-PAS and stained with collagen IV. The difference of the areas and distribution withpattern surrounded by between CD31 and PAS positive respectively were identified via grid-counting,as well as the difference of VEGF expression with VE absent and present. Results: The basementmembrane of VM was both PAS and collagen IV positive. VEGF expression in the bi-directiondifferential malignant tumor was higher VM-absent than VM-present and the difference wasstatistically significance in malignant melanoma and alveolar rhabdomyosarcoma (P 【 0.05).Conclusion: PAS positive substance and collagen IV compose the wall of VE and VE could provide theoxygen and nutrition for tumor growth and progression.
文摘A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters.
文摘The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inverter is comprised of a combined Buck/Boost DC/DC converter and a bridge circuit. The front stage converter is controlled to output variable DC voltage and the bridge circuit is used to convert the DC voltage to AC output. The energy feedback technology and one circle control scheme are used t...
文摘The pulse width modulation (PWM) scheme is used in the staircase waveform inverters. The control strategy and system characteristics are analyzed. While the single pulse width modulation is used, the 12 stairs waveform inverter can achieve the output voltage regulated in a wide range of input voltage as well as the perfect output waveform. A 1 500 V input 80 kVA inverter has been deve loped. Experiments of the 80kVA inverter resulted in that the scheme is a perfect method for the development of high power converters with high efficiency.
文摘DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the parallel inverter system without output isolation transformers, the difference of DC components of the output voltage can cause large DC loop-current among modular inverters. Aiming at this problem, this paper studies several DC loop-current detecting and restraining methods. By digital adjustment with high precision on the DC components of reference sine wave, the DC components of inverter′s output voltage can be adjusted to restrain DC loop-current. Experimental results prove that the DC loop-current detecting and restraining methods have a good performance.