Usually, the action of sea ice on offshore engineering structures is one of the controlling loads in cold waters engineering structure design. The reasonable selection of environmental condition and the physical mecha...Usually, the action of sea ice on offshore engineering structures is one of the controlling loads in cold waters engineering structure design. The reasonable selection of environmental condition and the physical mechanical properties of ice in the region are directly related to the structure design, operation and safety. In this paper, the sea ice force acting on the structure, the physical mechanical properties of ice and the selection of parameters in calculation are discussed. Some suggestions are proposed as to the calculation of various kinds of ice loads acting on the structure.展开更多
When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for li...When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for living human retina, which consists of a time domain OCT system and a 37-elements adaptive optics (AO) system, has been developed. The AO closed loop rate is 20 flames per second, and the OCT has a 6.7-μm axial resolution. In this paper, this system is introduced and the high resolution imaging results for retina are presented.展开更多
文摘Usually, the action of sea ice on offshore engineering structures is one of the controlling loads in cold waters engineering structure design. The reasonable selection of environmental condition and the physical mechanical properties of ice in the region are directly related to the structure design, operation and safety. In this paper, the sea ice force acting on the structure, the physical mechanical properties of ice and the selection of parameters in calculation are discussed. Some suggestions are proposed as to the calculation of various kinds of ice loads acting on the structure.
基金the Innovation Foundation of Chinese Academy of Sciences
文摘When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for living human retina, which consists of a time domain OCT system and a 37-elements adaptive optics (AO) system, has been developed. The AO closed loop rate is 20 flames per second, and the OCT has a 6.7-μm axial resolution. In this paper, this system is introduced and the high resolution imaging results for retina are presented.