This paper introduces the stress and deformation of anti floating anchor rod and explained the damage. Through field testing and numerical analysis, the article were studied the displacement and internal force of a ba...This paper introduces the stress and deformation of anti floating anchor rod and explained the damage. Through field testing and numerical analysis, the article were studied the displacement and internal force of a basement tensile anti float anchor, results showed that: the axial force of bolt tension transfer is top-down transfer, axial force decreases, the stress concentrate on the end. When a force is applied to a certain load, end firstly generate damage, but with the deepening of the axial force, it is greatly reduced, which indicates that the anchor force is an effective length, rather than the longer the anchor pullout force is bigger; anchor group effect is a problem that can not be ignored, because the engineering community for its attention degree is not enough, so that the design of anti floating anchor the lack of a reliable basis, the test results can provide a reference for the future design of anti floating anchor. Prestressed anchors in the tension lock, prestressed loss are regularly.展开更多
某工程所属地区遭遇一次强对流天气和强降雨,短时间内城区积水严重,部分区域形成冰雹堆积。24 h 降水量已超 50 mm,根据降水强度已达到暴雨等级。突降暴雨造成局部区域含水量过高,大量地表水渗入使水位不断抬升,形成部分区域地下水位过...某工程所属地区遭遇一次强对流天气和强降雨,短时间内城区积水严重,部分区域形成冰雹堆积。24 h 降水量已超 50 mm,根据降水强度已达到暴雨等级。突降暴雨造成局部区域含水量过高,大量地表水渗入使水位不断抬升,形成部分区域地下水位过高,超出抗浮设计水位。地下车库底板出现不同程度的裂缝、渗水,经现场实际全面检测鉴定,分析该地下车库底板开裂渗水成因,以期为类似问题提供参考。展开更多
文摘This paper introduces the stress and deformation of anti floating anchor rod and explained the damage. Through field testing and numerical analysis, the article were studied the displacement and internal force of a basement tensile anti float anchor, results showed that: the axial force of bolt tension transfer is top-down transfer, axial force decreases, the stress concentrate on the end. When a force is applied to a certain load, end firstly generate damage, but with the deepening of the axial force, it is greatly reduced, which indicates that the anchor force is an effective length, rather than the longer the anchor pullout force is bigger; anchor group effect is a problem that can not be ignored, because the engineering community for its attention degree is not enough, so that the design of anti floating anchor the lack of a reliable basis, the test results can provide a reference for the future design of anti floating anchor. Prestressed anchors in the tension lock, prestressed loss are regularly.
文摘某工程所属地区遭遇一次强对流天气和强降雨,短时间内城区积水严重,部分区域形成冰雹堆积。24 h 降水量已超 50 mm,根据降水强度已达到暴雨等级。突降暴雨造成局部区域含水量过高,大量地表水渗入使水位不断抬升,形成部分区域地下水位过高,超出抗浮设计水位。地下车库底板出现不同程度的裂缝、渗水,经现场实际全面检测鉴定,分析该地下车库底板开裂渗水成因,以期为类似问题提供参考。