The accuracy of thermal analysis measurements is critical to analyze material properties correctly,making the improvement of measurement precision and proper uncertainty analysis of test results absolutely essential.A...The accuracy of thermal analysis measurements is critical to analyze material properties correctly,making the improvement of measurement precision and proper uncertainty analysis of test results absolutely essential.As a primary thermal analysis instrument,the simultaneous thermal analyzer(STA)has unique advantages,which combines the functionalities of thermogravimetric(TG)analyzersand differential scanning calorimeters(DSC).However,the absence of standard quality control procedures has resulted in poor measurement reproducibility,low accuracy,and inadequate traceability of analytical results.This study utilized a multi-point temperature calibration method based on national certified reference materials to reduce instrument temperature indication errors.On this basis,we innovatively established a comprehensive quality control system encompassing laboratory environmental control,standard method selection,instrument performance verification,reference material traceability,and uncertainty analysis,thereby achieving standardized operational procedures for thermal analysis measurement.Taking the"determination of initial melting temperature of unknown substances"as a representative case study,a component resolution model for thermal analysis test uncertainty was developed.Through systematic analysis of both the reference material-introduced component and measurement repeatability component,complete traceability of test results was achieved.This approach ensures data validity and enhances the accuracy of test results.This provides crucial technical support and practical reference for the standardization of thermal analysis measurement procedure and assessment of result reliability.展开更多
Air-sea water vapor and CO_(2) flux observation experiments were carried out at the Yantai National Satellite Ocean Calibration Platform and the jetty at Monolithic Beach,Juehua Island,using a 100 Hz gas analyzer.The ...Air-sea water vapor and CO_(2) flux observation experiments were carried out at the Yantai National Satellite Ocean Calibration Platform and the jetty at Monolithic Beach,Juehua Island,using a 100 Hz gas analyzer.The observations were corrected by employing wild point rejection,linear detrending,delay correction,coordinate rotation,time matching,and Webb,Pearman,and Leuning(WPL)correction.The results of spectral analysis and a turbulence development adequacy data quality check showed that the overall observation data quality was good.The air-sea water vapor and CO_(2) flux results showed that the observation duration affected both the air-sea flux intensity and direction at different observation frequencies.At shorter observation durations,the air-sea flux values measured at 100 Hz were smaller than the 20 Hz measurements and had opposite directions.In addition,the WPL correction reduced the overall air-sea flux and partially minimized the effect of observation frequency on the air-sea flux intensity.These results showed that high-frequency observations showed more turbulence variations than low-frequency observations.This conclusion could promote an understanding of small-scale turbulence variations.展开更多
The level of urinary albumin is a critical indicator for the early diagnosis and management of chronic kidney disease(CKD).However,existing methods for detecting albumin are not conducive to point-of-care testing due ...The level of urinary albumin is a critical indicator for the early diagnosis and management of chronic kidney disease(CKD).However,existing methods for detecting albumin are not conducive to point-of-care testing due to the complexity of reagent addition and incubation processes.This study presents a smartphone-integrated handheld automated biochemical analyzer(sHABA)designed for point-of-care testing of urinary albumin.The sHABA features a pre-loaded,disposable reagent cassette with reagents for the albumin assay arranged in the order of their addition within a hose.The smartphone-integrated analyzer can drive the reagents following a preset program,to enable automatic sequential addition.The sHABA has a detection limit for albumin of 5.9 mg/L and a linear detection range from 7 to 450 mg/L.The consistency of albumin level detection in 931 urine samples using sHABA with clinical tests indicates good sensitivity(95.78%)and specificity(90.16%).This research advances the field by providing an automated detection method for albumin in a portable device,allowing even untrained individuals to monitor CKD in real time at the patient's bedside.In the context of promoting tiered diagnosis and treatment,the sHABA has the potential to become an essential tool for the early diagnosis and comprehensive management of CKD and other chronic conditions.展开更多
Biomechanical study of the visual system by ocular response analyzer investigates the inter-structural biological relationships,mechanics,and function of the visual system.This review aimed to investigate the changes ...Biomechanical study of the visual system by ocular response analyzer investigates the inter-structural biological relationships,mechanics,and function of the visual system.This review aimed to investigate the changes in corneal biomechanical parameters with age and sex.The articles published in PubMed between 2000 and 2021 were investigated and critiqued,and valid scientific evidence was collected,reviewed and concluded according to the inclusion and exclusion criteria.Most studies showed that corneal biomechanical changes occur infrequently in children up to the age of 20y,and with increasing age and wider age range,there was a significant decrease in corneal biomechanical indices,especially corneal hysteresis.In children and adults,most studies have shown that these biomechanical indicators,especially corneal resistance factor,were higher in females.Although hormonal changes may contribute to this finding,the role of axial length and other biometric indicators should not be ignored.The axial length,the intraocular pressure,and the corneal thickness are other factors associated with biomechanical parameters that should be taken into account in clinical diagnosis and management especially for patients undergoing refractive surgery as well as keratoconus patients.展开更多
In this study, nine high-lysine maize kernels and two kernels of common maize hybrid were used as experiment materials, and quantitative determination of lysine contents in high-lysine maize kernels and common maize k...In this study, nine high-lysine maize kernels and two kernels of common maize hybrid were used as experiment materials, and quantitative determination of lysine contents in high-lysine maize kernels and common maize kernels was carried out using Hitachi L-8900 Automatic Amino-acid Analyzer, to know the effect of the Analyzer in distinguishing the lysine contents between common maize kernels and high-lysine maize kernels. The results showed that the lysine contents of high-lysine maize kernels were among 0.34%-0.42%, while of common maize kernels were a- mong 0.24%-0.25%, and the difference was significant. Compared with other tradi- tional methods, this method is rapid, simple, sensitive, highly reproductive and needs fewer maize kernels, thus it is applicable in maize breeding.展开更多
Lock-in amplifiers are used to detect and measure very small alternating current(AC)signals down to the range of nVs.Accurate measurements can be made even when the small signals are buried by noise thousands of times...Lock-in amplifiers are used to detect and measure very small alternating current(AC)signals down to the range of nVs.Accurate measurements can be made even when the small signals are buried by noise thousands of times larger.With the digital signal processing(DSP)technology involved in modern instrumentation,a lock-in amplifier is more versatile in sensing and recovering small signals.Combining the virtual instrumentation technology,we reorganize the functional blocks of a programmable lock-in amplifier and build it as a virtual spectrum analyzer,virtual impedance meter,virtual network analyzer,virtual semiconductor parameter analyzer,signal generator,etc.A 4 layer model is used to implement these virtual instruments.The same virtual instrument can also be implemented on a general purpose FPGA developing board.展开更多
辽宁某公司原凝析油蒸馏装置加工能力10万t/a,2013年将其加工能力改造至22万t/a。装置在改造设计过程中,为降低能耗,对换热网络采用Aspen Energy Analyzer软件进行优化设计,换热网络优化改造后各换热单元冷端温差均大于夹点温差20℃,热...辽宁某公司原凝析油蒸馏装置加工能力10万t/a,2013年将其加工能力改造至22万t/a。装置在改造设计过程中,为降低能耗,对换热网络采用Aspen Energy Analyzer软件进行优化设计,换热网络优化改造后各换热单元冷端温差均大于夹点温差20℃,热负荷均大于4.186 8×105k J/h;投资费有所降低,虽然改造后加热负荷和冷却负荷均有所增加,但换热网络符合能量松弛的原则,总体上,凝析油蒸馏装置的换热网络得到了优化,满足了换热网络投资费用和操作费用最小的要求。展开更多
The increasing morbidity of internal diseases poses serious threats to human health and quality of life.Exhaled breath analysis is a noninvasive and convenient diagnostic method to improve the cure rate of patients. I...The increasing morbidity of internal diseases poses serious threats to human health and quality of life.Exhaled breath analysis is a noninvasive and convenient diagnostic method to improve the cure rate of patients. In this study, a self-powered breath analyzer based on polyaniline/polyvinylidene fluoride(PANI/PVDF) piezogas-sensing arrays has been developed for potential detection of several internal diseases. The device works by converting exhaled breath energy into piezoelectric gassensing signals without any external power sources. The five sensing units in the device have different sensitivities to various gas markers with concentrations ranging from 0 to 600 ppm. The working principle can be attributed to the coupling of the in-pipe gas-flow-induced piezoelectric effect of PVDF and gas-sensing properties of PANI electrodes. In addition, the device demonstrates its use as an ethanol analyzer to roughly mimic fatty liver diagnosis.This new approach can be applied to fabricating new exhaled breath analyzers and promoting the development of self-powered systems.展开更多
The main objective of the Mars Ion and Neutral Particle Analyzer(MINPA)aboard the Chinese Mars Exploration Mission(Tianwen-1)is to study the solar wind-Mars interaction by measuring the ions and energetic neutral atom...The main objective of the Mars Ion and Neutral Particle Analyzer(MINPA)aboard the Chinese Mars Exploration Mission(Tianwen-1)is to study the solar wind-Mars interaction by measuring the ions and energetic neutral atoms(ENAs)near Mars.The MINPA integrates ion and ENA measurements into one sensor head,sharing the same electronics box.The MINPA utilizes a standard toroidal top-hat electrostatic analyzer(ESA)followed by a time of flight(TOF)unit to provide measurement of ions with energies from 2.8 eV to 25.9 keV and ENAs from 50 eV to 3 keV with a base time resolution of 4 seconds.Highly polished silicon single crystal substrates with an Al2O3 film coating are used to ionize the ENAs into positive ions.These ions can then be analyzed by the ESA and TOF,to determine the energy and masses of the ENAs.The MINPA provides a 360°×90°field of view(FOV)with 22.5°×5.4°angular resolution for ion measurement,and a 360°×9.7°FOV with 22.5°×9.7°angular resolution for ENA measurement.The TOF unit combines a-15 kV acceleration high voltage with ultra-thin carbon foils to resolve H+,He2+,He+,O+,O2+and CO2+for ion measurement and to resolve H and O(≥16 amu group)for ENA measurement.Here we present the design principle and describe our ground calibration of the MINPA.展开更多
火炬气的排放系统设计是一个非常复杂的过程,涉及到各泄放点的背压与管路马赫数的计算。介绍了Aspen Flare System Analyzer模拟软件的特点及应用方法,该软件遵循API的规范要求,通过计算火炬管网中各管段始末点的压力、温度、流速等参数...火炬气的排放系统设计是一个非常复杂的过程,涉及到各泄放点的背压与管路马赫数的计算。介绍了Aspen Flare System Analyzer模拟软件的特点及应用方法,该软件遵循API的规范要求,通过计算火炬管网中各管段始末点的压力、温度、流速等参数,可有效发现设计中的不合理管径并进行修改。以中东某油田地面工程项目为例,阐述了在工程实际中如何通过该软件进行火炬管网核算。高压火炬管网的核算结果显示,部分安全阀尾管背压和马赫数过大,经软件修改后的尺寸在实际运行中可满足火炬气的排放要求,保证了系统安全。表明了该软件在安全阀的选型和火炬管网的设计工作中的应用价值。展开更多
Readout electronics is developed for a prototype time-of-flight(TOF) ion composition spectrometer for in situ measurement of the mass/charge distributions of major ion species from 200 to 100 ke V/e in space plasma.By...Readout electronics is developed for a prototype time-of-flight(TOF) ion composition spectrometer for in situ measurement of the mass/charge distributions of major ion species from 200 to 100 ke V/e in space plasma.By utilizing a constant fraction discriminator(CFD) and time-to-digital converter(TDC), challenging dynamic range measurements were performed with high time resolution and event rates. CFD was employed to discriminate the TOF signals from the micro-channel plate and channel electron multipliers. TDC based on the combination of counter and OR-gate delay chain was designed in a highreliability flash field programmable gate array. Owing to the non-uniformity of the delay chain, a correction algorithm based on integral nonlinearity compensation was implemented to reduce the time uncertainty. The test results showed that the electronics achieved a low timingerror of < 200 ps in the input range from 35 to 500 m V for the CFD, and a time resolution of ~550 ps with time uncertainty < 180 ps after correction and a time range of6.4 ls for the TDC. The TOF spectrum from an electron beam experiment of the impacting N_2 gas further indicated the good performance of this readout electronic.展开更多
The rice starch viscosity characteristics, which can be indicated by Rapid Visco Analyzer profile (RVA profile), have been proved useful for the evaluation of cooking and eating quality in rice breeding program. To ...The rice starch viscosity characteristics, which can be indicated by Rapid Visco Analyzer profile (RVA profile), have been proved useful for the evaluation of cooking and eating quality in rice breeding program. To study the inheritance of the RVA profile, an F2 population of Wuyujing 3/Aichi 106 was used. The results indicated that the peak viscosity (PKV) was a typical quantitative character, and the hot paste viscosity (HPV), cool paste viscosity (CPV), setback viscosity (SBV), breakdown viscosity (BDV), and consistence viscosity (CSV) might be controlled by one major gene and several minor genes To elucidate the genetic basis of the paste viscosity characteristics, a recombinant inbred line (RIL) population derived from Nikken 2/Milyang 23 and its genetic linkage map were used to map the QTLs controlling RVA profiles in 2005 and 2006. A total of 34 QTLs distributed on chromosomes 1,2, 3, 4, 6, 7 and 8 were detected, including 19 and 15 QTLs in 2005 and 2006 respectively. Eight QTLs were both detected in the two years, qHPV6, qCPV6, qCSV6, qSBV6, and qBDV6 were located on chromosome 6, while qHPV2, qCSV2, and qCPV2were on chromosome 2.展开更多
AIM: To explore the relationship between different parameters of Ocular Response Analyzer(ORA) and Corvis ST(CST) in a sample of healthy Iranian school-aged children and the relationship between parameters of the...AIM: To explore the relationship between different parameters of Ocular Response Analyzer(ORA) and Corvis ST(CST) in a sample of healthy Iranian school-aged children and the relationship between parameters of these 2 instruments against intraocular pressure(IOP), measured by the Goldmann applanation tonometer(GAT-IOP), age and gender, and find possible correlation between ORA and CST with GAT.METHODS: This cross-sectional study included 90 healthy children. A general interview and complete eye examination were performed. Following successful GATIOP measurement, ORA and CST were conducted. The CST parameters were A 1/2 length(A1 L, A2 L), A 1/2 velocity(A1 V, A2 V), highest concavity deformation amplitude(HCDA), radius of curvature(Ro C), peak distance(PD), central corneal thickness(CCT) and IOP. The ORA parameters were corneal hysteresis(CH), corneal resistance factor(CRF), Goldmann-correlated IOP(IOP-G) and corneal compensated IOP(IOP-CC). Extracted data was analyzed using the Statistical Package for Social Science software.RESULTS: Totally 39 males with age of 9.08±1.60(6-12)y and 51 females with age of 8.96±1.55(6-13)y were included. Many CST parameters were significantly correlated with CH, CRF, IOP-G and IOP-CC. Some CST parameters had a significant correlation with GAT-IOP, including IOP-CST in both eyes and HCDA, A2 L, PD, and RoC in the left eye, but none with age, except A2 L in the right eye. The CRF measurement showed a significant correlation with GAT-IOP in both eyes and CH in the right eye, yet, none with age. Among all CST and ORA parameters, CCT-CST in both eyes and A1 L in right eye had a significant correlation with gender, although this was a negligible negative correlation. Comparison of mean IOP values by different devices showed a significantly highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Also, IOP-G versus IOP-CST significantly had the lowest IOP overestimation among others. Overall, either low positive correlation or negligible correlation was found between IOP measurements by 3 instruments.CONCLUSION: The study finds the highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Overall, either low positive correlation or negligible correlation is found between IOP measurements by the 3 instruments.展开更多
文摘The accuracy of thermal analysis measurements is critical to analyze material properties correctly,making the improvement of measurement precision and proper uncertainty analysis of test results absolutely essential.As a primary thermal analysis instrument,the simultaneous thermal analyzer(STA)has unique advantages,which combines the functionalities of thermogravimetric(TG)analyzersand differential scanning calorimeters(DSC).However,the absence of standard quality control procedures has resulted in poor measurement reproducibility,low accuracy,and inadequate traceability of analytical results.This study utilized a multi-point temperature calibration method based on national certified reference materials to reduce instrument temperature indication errors.On this basis,we innovatively established a comprehensive quality control system encompassing laboratory environmental control,standard method selection,instrument performance verification,reference material traceability,and uncertainty analysis,thereby achieving standardized operational procedures for thermal analysis measurement.Taking the"determination of initial melting temperature of unknown substances"as a representative case study,a component resolution model for thermal analysis test uncertainty was developed.Through systematic analysis of both the reference material-introduced component and measurement repeatability component,complete traceability of test results was achieved.This approach ensures data validity and enhances the accuracy of test results.This provides crucial technical support and practical reference for the standardization of thermal analysis measurement procedure and assessment of result reliability.
基金The National Key Research and Development Program of China under contract Nos 2022YFC3104203 and 2018YFC0213103the Science Foundation of Donghai Laboratory under contract No.DH-2022KF01019+1 种基金the National Natural Science Foundation under contract No.419061522023 Shanghai Education Science Research Project under contract No.C2023120.
文摘Air-sea water vapor and CO_(2) flux observation experiments were carried out at the Yantai National Satellite Ocean Calibration Platform and the jetty at Monolithic Beach,Juehua Island,using a 100 Hz gas analyzer.The observations were corrected by employing wild point rejection,linear detrending,delay correction,coordinate rotation,time matching,and Webb,Pearman,and Leuning(WPL)correction.The results of spectral analysis and a turbulence development adequacy data quality check showed that the overall observation data quality was good.The air-sea water vapor and CO_(2) flux results showed that the observation duration affected both the air-sea flux intensity and direction at different observation frequencies.At shorter observation durations,the air-sea flux values measured at 100 Hz were smaller than the 20 Hz measurements and had opposite directions.In addition,the WPL correction reduced the overall air-sea flux and partially minimized the effect of observation frequency on the air-sea flux intensity.These results showed that high-frequency observations showed more turbulence variations than low-frequency observations.This conclusion could promote an understanding of small-scale turbulence variations.
基金funding by the China Postdoctoral Science Foundation(Grant No.:2021M701628)the National Natural Science Foundation of China(Grant No.:82202625)+3 种基金Science and Technology Projects in Guangzhou,China(Grant No.:SL2022A04J02086)President Foundation of Nanfang Hospital,Southern Medical University,China(Grant Nos.:2021B012,and 2021C050)National Science Fund for Distinguished Young Scholars,China(Grant No.:82025024)Key project of the National Natural Science Foundation of China(Grant No.:82230080).
文摘The level of urinary albumin is a critical indicator for the early diagnosis and management of chronic kidney disease(CKD).However,existing methods for detecting albumin are not conducive to point-of-care testing due to the complexity of reagent addition and incubation processes.This study presents a smartphone-integrated handheld automated biochemical analyzer(sHABA)designed for point-of-care testing of urinary albumin.The sHABA features a pre-loaded,disposable reagent cassette with reagents for the albumin assay arranged in the order of their addition within a hose.The smartphone-integrated analyzer can drive the reagents following a preset program,to enable automatic sequential addition.The sHABA has a detection limit for albumin of 5.9 mg/L and a linear detection range from 7 to 450 mg/L.The consistency of albumin level detection in 931 urine samples using sHABA with clinical tests indicates good sensitivity(95.78%)and specificity(90.16%).This research advances the field by providing an automated detection method for albumin in a portable device,allowing even untrained individuals to monitor CKD in real time at the patient's bedside.In the context of promoting tiered diagnosis and treatment,the sHABA has the potential to become an essential tool for the early diagnosis and comprehensive management of CKD and other chronic conditions.
基金Supported by Noor Ophthalmology Research Center.
文摘Biomechanical study of the visual system by ocular response analyzer investigates the inter-structural biological relationships,mechanics,and function of the visual system.This review aimed to investigate the changes in corneal biomechanical parameters with age and sex.The articles published in PubMed between 2000 and 2021 were investigated and critiqued,and valid scientific evidence was collected,reviewed and concluded according to the inclusion and exclusion criteria.Most studies showed that corneal biomechanical changes occur infrequently in children up to the age of 20y,and with increasing age and wider age range,there was a significant decrease in corneal biomechanical indices,especially corneal hysteresis.In children and adults,most studies have shown that these biomechanical indicators,especially corneal resistance factor,were higher in females.Although hormonal changes may contribute to this finding,the role of axial length and other biometric indicators should not be ignored.The axial length,the intraocular pressure,and the corneal thickness are other factors associated with biomechanical parameters that should be taken into account in clinical diagnosis and management especially for patients undergoing refractive surgery as well as keratoconus patients.
基金Supported by Henan Major Scientific and Technological Project(121100110300)Outstanding Youth Project of Henan Academy of Agricultural Sciences(2013YQ006)~~
文摘In this study, nine high-lysine maize kernels and two kernels of common maize hybrid were used as experiment materials, and quantitative determination of lysine contents in high-lysine maize kernels and common maize kernels was carried out using Hitachi L-8900 Automatic Amino-acid Analyzer, to know the effect of the Analyzer in distinguishing the lysine contents between common maize kernels and high-lysine maize kernels. The results showed that the lysine contents of high-lysine maize kernels were among 0.34%-0.42%, while of common maize kernels were a- mong 0.24%-0.25%, and the difference was significant. Compared with other tradi- tional methods, this method is rapid, simple, sensitive, highly reproductive and needs fewer maize kernels, thus it is applicable in maize breeding.
文摘Lock-in amplifiers are used to detect and measure very small alternating current(AC)signals down to the range of nVs.Accurate measurements can be made even when the small signals are buried by noise thousands of times larger.With the digital signal processing(DSP)technology involved in modern instrumentation,a lock-in amplifier is more versatile in sensing and recovering small signals.Combining the virtual instrumentation technology,we reorganize the functional blocks of a programmable lock-in amplifier and build it as a virtual spectrum analyzer,virtual impedance meter,virtual network analyzer,virtual semiconductor parameter analyzer,signal generator,etc.A 4 layer model is used to implement these virtual instruments.The same virtual instrument can also be implemented on a general purpose FPGA developing board.
文摘辽宁某公司原凝析油蒸馏装置加工能力10万t/a,2013年将其加工能力改造至22万t/a。装置在改造设计过程中,为降低能耗,对换热网络采用Aspen Energy Analyzer软件进行优化设计,换热网络优化改造后各换热单元冷端温差均大于夹点温差20℃,热负荷均大于4.186 8×105k J/h;投资费有所降低,虽然改造后加热负荷和冷却负荷均有所增加,但换热网络符合能量松弛的原则,总体上,凝析油蒸馏装置的换热网络得到了优化,满足了换热网络投资费用和操作费用最小的要求。
基金supported by the National Natural Science Foundation of China (11674048)the Fundamental Research Funds for the Central Universities (N170505001 and N160502002)Program for Shenyang Youth Science and Technology Innovation Talents (RC170269)
文摘The increasing morbidity of internal diseases poses serious threats to human health and quality of life.Exhaled breath analysis is a noninvasive and convenient diagnostic method to improve the cure rate of patients. In this study, a self-powered breath analyzer based on polyaniline/polyvinylidene fluoride(PANI/PVDF) piezogas-sensing arrays has been developed for potential detection of several internal diseases. The device works by converting exhaled breath energy into piezoelectric gassensing signals without any external power sources. The five sensing units in the device have different sensitivities to various gas markers with concentrations ranging from 0 to 600 ppm. The working principle can be attributed to the coupling of the in-pipe gas-flow-induced piezoelectric effect of PVDF and gas-sensing properties of PANI electrodes. In addition, the device demonstrates its use as an ethanol analyzer to roughly mimic fatty liver diagnosis.This new approach can be applied to fabricating new exhaled breath analyzers and promoting the development of self-powered systems.
基金funded by the Chinese National Space Administration.
文摘The main objective of the Mars Ion and Neutral Particle Analyzer(MINPA)aboard the Chinese Mars Exploration Mission(Tianwen-1)is to study the solar wind-Mars interaction by measuring the ions and energetic neutral atoms(ENAs)near Mars.The MINPA integrates ion and ENA measurements into one sensor head,sharing the same electronics box.The MINPA utilizes a standard toroidal top-hat electrostatic analyzer(ESA)followed by a time of flight(TOF)unit to provide measurement of ions with energies from 2.8 eV to 25.9 keV and ENAs from 50 eV to 3 keV with a base time resolution of 4 seconds.Highly polished silicon single crystal substrates with an Al2O3 film coating are used to ionize the ENAs into positive ions.These ions can then be analyzed by the ESA and TOF,to determine the energy and masses of the ENAs.The MINPA provides a 360°×90°field of view(FOV)with 22.5°×5.4°angular resolution for ion measurement,and a 360°×9.7°FOV with 22.5°×9.7°angular resolution for ENA measurement.The TOF unit combines a-15 kV acceleration high voltage with ultra-thin carbon foils to resolve H+,He2+,He+,O+,O2+and CO2+for ion measurement and to resolve H and O(≥16 amu group)for ENA measurement.Here we present the design principle and describe our ground calibration of the MINPA.
文摘火炬气的排放系统设计是一个非常复杂的过程,涉及到各泄放点的背压与管路马赫数的计算。介绍了Aspen Flare System Analyzer模拟软件的特点及应用方法,该软件遵循API的规范要求,通过计算火炬管网中各管段始末点的压力、温度、流速等参数,可有效发现设计中的不合理管径并进行修改。以中东某油田地面工程项目为例,阐述了在工程实际中如何通过该软件进行火炬管网核算。高压火炬管网的核算结果显示,部分安全阀尾管背压和马赫数过大,经软件修改后的尺寸在实际运行中可满足火炬气的排放要求,保证了系统安全。表明了该软件在安全阀的选型和火炬管网的设计工作中的应用价值。
基金supported by the National Key Scientific Instrument and Equipment Development Projects of the National Natural Science Foundation of China(No.41327802)China Mars Project
文摘Readout electronics is developed for a prototype time-of-flight(TOF) ion composition spectrometer for in situ measurement of the mass/charge distributions of major ion species from 200 to 100 ke V/e in space plasma.By utilizing a constant fraction discriminator(CFD) and time-to-digital converter(TDC), challenging dynamic range measurements were performed with high time resolution and event rates. CFD was employed to discriminate the TOF signals from the micro-channel plate and channel electron multipliers. TDC based on the combination of counter and OR-gate delay chain was designed in a highreliability flash field programmable gate array. Owing to the non-uniformity of the delay chain, a correction algorithm based on integral nonlinearity compensation was implemented to reduce the time uncertainty. The test results showed that the electronics achieved a low timingerror of < 200 ps in the input range from 35 to 500 m V for the CFD, and a time resolution of ~550 ps with time uncertainty < 180 ps after correction and a time range of6.4 ls for the TDC. The TOF spectrum from an electron beam experiment of the impacting N_2 gas further indicated the good performance of this readout electronic.
基金supported by the National High- tech Research and Development Program of China (Grant No. 2006AA100101)the Super-rice Breeding and Demonstration Program of Chinese Ministry of Agriculture+1 种基金the Special Research Program on Key Technology of Agricultural Structure Adjustment (Grant No. 05-01-05B),ChinaJiangsu High Technology Program , China (Grant No. BG2004304)
文摘The rice starch viscosity characteristics, which can be indicated by Rapid Visco Analyzer profile (RVA profile), have been proved useful for the evaluation of cooking and eating quality in rice breeding program. To study the inheritance of the RVA profile, an F2 population of Wuyujing 3/Aichi 106 was used. The results indicated that the peak viscosity (PKV) was a typical quantitative character, and the hot paste viscosity (HPV), cool paste viscosity (CPV), setback viscosity (SBV), breakdown viscosity (BDV), and consistence viscosity (CSV) might be controlled by one major gene and several minor genes To elucidate the genetic basis of the paste viscosity characteristics, a recombinant inbred line (RIL) population derived from Nikken 2/Milyang 23 and its genetic linkage map were used to map the QTLs controlling RVA profiles in 2005 and 2006. A total of 34 QTLs distributed on chromosomes 1,2, 3, 4, 6, 7 and 8 were detected, including 19 and 15 QTLs in 2005 and 2006 respectively. Eight QTLs were both detected in the two years, qHPV6, qCPV6, qCSV6, qSBV6, and qBDV6 were located on chromosome 6, while qHPV2, qCSV2, and qCPV2were on chromosome 2.
基金Supported by deputy dean in research of School of Medicine according to study project and deputy vice chancellor of Shiraz University of Medical Sciences
文摘AIM: To explore the relationship between different parameters of Ocular Response Analyzer(ORA) and Corvis ST(CST) in a sample of healthy Iranian school-aged children and the relationship between parameters of these 2 instruments against intraocular pressure(IOP), measured by the Goldmann applanation tonometer(GAT-IOP), age and gender, and find possible correlation between ORA and CST with GAT.METHODS: This cross-sectional study included 90 healthy children. A general interview and complete eye examination were performed. Following successful GATIOP measurement, ORA and CST were conducted. The CST parameters were A 1/2 length(A1 L, A2 L), A 1/2 velocity(A1 V, A2 V), highest concavity deformation amplitude(HCDA), radius of curvature(Ro C), peak distance(PD), central corneal thickness(CCT) and IOP. The ORA parameters were corneal hysteresis(CH), corneal resistance factor(CRF), Goldmann-correlated IOP(IOP-G) and corneal compensated IOP(IOP-CC). Extracted data was analyzed using the Statistical Package for Social Science software.RESULTS: Totally 39 males with age of 9.08±1.60(6-12)y and 51 females with age of 8.96±1.55(6-13)y were included. Many CST parameters were significantly correlated with CH, CRF, IOP-G and IOP-CC. Some CST parameters had a significant correlation with GAT-IOP, including IOP-CST in both eyes and HCDA, A2 L, PD, and RoC in the left eye, but none with age, except A2 L in the right eye. The CRF measurement showed a significant correlation with GAT-IOP in both eyes and CH in the right eye, yet, none with age. Among all CST and ORA parameters, CCT-CST in both eyes and A1 L in right eye had a significant correlation with gender, although this was a negligible negative correlation. Comparison of mean IOP values by different devices showed a significantly highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Also, IOP-G versus IOP-CST significantly had the lowest IOP overestimation among others. Overall, either low positive correlation or negligible correlation was found between IOP measurements by 3 instruments.CONCLUSION: The study finds the highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Overall, either low positive correlation or negligible correlation is found between IOP measurements by the 3 instruments.