Alumina Solubility in Na_(3)A1F_(6)-K_(3)A1F_(6)-A1F_(3)Molten Salt System Prospective for Aluminum Electrolysis at Lower Temperature 被引量:1
1
作者 LI Jie YUAN Chang-fu +3 位作者 TIAN Zhong-liang WANG Jia-wei LAI Yan-qing LIU Ye-xiang 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第1期142-146,共5页
The alumina solubility in the title system within the composition range of KR{m(K3AlF6)/[m(K3AlF6)+m(Na3AlF6)]}10%―50%,a ternary Na_(3)A1F_(6)-K_(3)A1F_(6)-A1F_(3)molten system with 23%―29%(mass fraction)AlF3 was in... The alumina solubility in the title system within the composition range of KR{m(K3AlF6)/[m(K3AlF6)+m(Na3AlF6)]}10%―50%,a ternary Na_(3)A1F_(6)-K_(3)A1F_(6)-A1F_(3)molten system with 23%―29%(mass fraction)AlF3 was investigated by measuring the mass loss of a rotating sintered corundum disc.And the following empirical equation was derived when superheat degree was no more than 60°C:w(Al2O3)sat=A×(T/1000)B,where A=–1.85774+26.754234w(AlF3)–0.3683–0.00783KR2.363+0.010266KR2.3048+0.7902w(AlF3)0.00652,B=112.4625–53.2567w(AlF3)0.4236+5.1079w(AlF3)0.9241+0.01542w(AlF3)1.3540.Considering both higher alumina solubility and not too high superheat de gree are required,alumina solubility of different compositions at not the same temperature but the same superheat degree was studied,which will be more industrial helpful for selecting prospective compositions.The results show that the composition deserved to be further tested in lower temperature cells is 10%―30%KR and 23%―26%(mass fraction)AlF3. 展开更多
关键词 Alumina solubility Lower temperature electrolyte Na_(3)A1F_(6)-K_(3)A1F_(6)-A1F_(3)molten salt system aluminumelectrolysis